Radiation Dose Impact of an Overpack Storage Configuration for Plutonium Disposition
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Hanford Site in Washington State manages legacy high-level radioactive waste streams that display major chemistry and engineering challenges, including the high salt levels and pH values that correspond to conditions under which many classical concepts describing chemical reactivity cannot be applied. One particular challenge that needs to be tackled at Hanford is that Pu concentrations, [Pu], in the soluble phases of the tank wastes are higher than expected based on the solubility of crystalline PuO2, which is widely accepted to be caused by the formation of PuO2 colloid, consisting of nano- to submicron-sized particles (PuO2 NPs). Fundamental research underpinning the behavior of PuO2 NPs under conditions not only relevant to the Hanford tank waste but at high ionic strength in general is needed to reliably predict the chemical reactivity of PuO2 NPs and develop engineering solutions to safely and efficiently process high-level radioactive waste into forms suitable for long-term storage. In this work, we study the behavior of PuO2 NPs (particle size ~100 nm) under high ionic strength conditions by reacting it with highly concentrated (up to 5 M) salt solutions. We explore different electrolyte compositions to elucidate the impact of different anions (NO3-, Cl-, ClO4-, SO42-, C2O42-, CO32-) on the stability of PuO2 NP in the acidic and alkaline pH regime. PuO2 NP aggregation and precipitation as function electrolyte concentration is tracked by a combination of liquid scintillation counting, dynamic light scattering for determination of particle size distributions, and zeta potentials as a proxy for particle charge. At acidic pH, electrolytes containing non-coordinating anions, such as NaNO3, NaCl, and NaClO4 mostly stabilize PuO2 NPs over a large electrolyte concentration range, showing only subtle differences in their reactivity. Other electrolyte anions show a more pronounced effect on the PuO2 NP stability: SO42-, binds directly to the particles’ surface, reverses the particle charge, and precipitates the PuO2 NPs efficiently even at intermediate sulfate concentrations (>0.1 M). In contrast, C2O42- is found to lead to high [Pu] in solution, in the milli-molar range, even at mildly acidic pH (~4). Thermodynamic modeling of the dissolved Pu concentrations using PHREEQC is unable to predict the observed [Pu] in the acidic pH regime, supporting the influence of colloids in maintaining elevated [Pu]. It is noteworthy that the current thermodynamic databases do not include constants for colloidal Pu phases and cannot accurately predict many of the high ionic strength solutions relevant to this work. The mechanisms and models responsible for these observations will need further investigation in the future. At high pH values (~12), PuO2 NPs exhibits classical sol-gel chemistry, meaning that upon destabilization of the colloidal sol, for example by addition of concentrated NaOH, highly porous and viscid PuO2 coagulates are formed that consist of a three-dimensional network likely held together by physical interactions. The PuO2 NP coagulate shows no significant reversibility of the aggregation when contacted with concentrated brines; however, PuO2 NPs can be efficiently resuspended in solution by addition of diluted electrolytes, alkaline solutions containing high amounts of carbonate, or simple addition of water. Especially carbonate is shown to stabilize PuO2 NPs in solution at high pH, characterized by stable colloidal suspensions that are resistant against sedimentation during centrifugation. Thermodynamic modeling of the carbonate system was able to predict an increasing dissolved Pu concentration with increasing carbonate concentration. However, the model was profoundly sensitive to the fixed redox potential and does not include any thermodynamic constants for colloidal Pu species.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Inelastic x-ray scattering measurements of the phonon density of states (DOS) were performed on polycrystalline samples of pure {alpha}-Pu and {delta}-Pu{sub 0.98}Ga{sub 0.02} at room temperature. The heat capacity of {alpha}-Pu is well reproduced by contributions calculated from the measured phonon DOS plus conventional thermal expansion and electronic contributions, showing that {alpha}-Pu is a 'well-behaved' metal in this regard. A comparison of the phonon DOS of the two phases at room temperature surprised us in that the vibrational entropy difference between them is only a quarter of the total entropy difference expected from known thermodynamic measurements. The missing entropy is too large to be accounted for by conventional electronic entropy and evidence from the literature rules out a contribution from spin fluctuations. Possible alternative sources for the missing entropy are discussed.
Abstract Not Provided
Resonant ultrasound spectroscopy was used to measure the elastic properties of pure polycrystalline {sup 239}Pu in the {gamma} phase. Shear and longitudinal elastic moduli were measured simultaneously and the bulk modulus was computed from them. A smooth, linear, and large decrease of all elastic moduli with increasing temperature was observed. They calculated the Poisson ratio and found that it increases from 0.242 at 519 K to 0.252 at 571 K. These measurements on extremely well characterized pure Pu are in agreement with other reported results where overlap occurs.
This project was funded to Dr. Mary Neu (LANL) and to Dr. Patricia Holden (UCSB) during the period 10/01/04-09/30/07 with the overall objective of, as stated in the proposal, to investigate how key reactions, which are known to affect major redox-active transition metals such as Fe and Mn, can affect Pu speciation and environmental mobility. The goals included investigating a) bacterial accumulation and immobilization of Pu species by Pseudomonas putida biofilm formation, and b) bacterial mineralization and immobilization via direct enzymatic and indirect biogeochemical reduction of Pu species by Geobacter metallireducens. Through a combination of aqueous chemical, radioanalytical, spectroscopic and microscopic analyses, Pu speciation and solution/solid phase distributions were to be characterized. The combination of biotransformation and biogeochemical research was aimed at filling significant gaps in the scientific basis for monitored natural attenuation and in situ stabilization of widespread and problematic Pu contamination, as well as providing immediately useful data to modeling and risk assessment efforts.
The Savannah River National Laboratory (SRNL) 3013 destructive examination program performs surveillances on 3013 containers originating from multiple sites across the DOE complex. The bases for the packaging, storage, and surveillance activities are derived from the Department of Energy's 3013 Standard (DOE-STD-3013-2004). During destructive examination, headspace gas samples are obtained from the 3013 inner container and the annulus between the outer and inner containers. To characterize gas species, the samples are analyzed by gas chromatography (GC), direct-inlet mass spectrometry (DIMS), and Fourier-transform infrared spectroscopy (FTIR). The GC results, as well as other parameters, are utilized as input into the gas evaluation software tool (GEST) program for computation of pre-puncture gas compositions and pressures. Over 30 containers from the Hanford Site and the Rocky Flats Environmental Technology Site (RFETS) have been examined in the first three years of the surveillance program. Several containers were shown to have appreciable hydrogen content (some greater than 30 mol %), yet little or no oxygen was detected in any of the containers, including those exhibiting high hydrogen concentrations. Characteristics including moisture content, surface area, and material composition, along with the headspace gas composition, are utilized in an attempt to explain the chemical behavior of the packaged materials.
The destructive examination (DE) of 3013 containers after storage is part of the Surveillance and Monitoring Program based on the Department of Energy's standard for long-term storage of Pu (DOE-STD-3013). The stored, Pu-bearing materials may contain alkali halide contamination that varies from trace amounts of salt to about 50 weight percent, with smaller fractions of other compounds and oxides. These materials were characterized prior to packaging, and surveillance characterizations are conducted to determine the behavior of the materials during long term storage. The surveillance characterization results are generally in agreement with the pre-surveillance data. The predominant phases identified by X-ray diffraction are in agreement with the expected phase assemblages of the as-received materials. The measured densities are in reasonable agreement with the expected densities of materials containing the fraction of salts and actinide oxide specified by the pre-surveillance data. The radiochemical results are generally in good agreement with the pre-surveillance data for mixtures containing 'weapons grade' Pu (nominally 94% {sup 239}Pu and 6% {sup 240}Pu); however, the ICP-MS results from the present investigation generally produce lower concentrations of Pu than the pre-surveillance analyses. For mixtures containing 'fuel grade' Pu (nominally 81-93% {sup 239}Pu and 7-19% {sup 240}Pu), the ICP-MS results from the present investigation appear to be in better agreement with the pre-surveillance data than the radiochemistry results.
Abstract Not Provided
A review of transuranic radionuclide contamination in sediments and groundwater at the DOE’s Hanford Site was conducted. The review focused primarily on plutonium-239/240 and americium-241; however, other transuranic nuclides were discussed as well, including neptunium-237, plutonium-238, and plutonium-241. The scope of the review included liquid process wastes intentionally disposed to constructed waste disposal facilities such as trenches and cribs, burial grounds, and unplanned releases to the ground surface. The review did not include liquid wastes disposed to tanks or solid wastes disposed to burial grounds. It is estimated that over 11,800 Ci of plutonium-239, 28,700 Ci of americium-241, and 55 Ci of neptunium-237 have been disposed as liquid waste to the near surface environment at the Hanford Site. Despite the very large quantities of transuranic contaminants disposed to the vadose zone at Hanford, only minuscule amounts have entered the groundwater. Currently, no wells onsite exceed the DOE derived concentration guide for plutonium-239/240 (30 pCi/L) or any other transuranic contaminant in filtered samples. The DOE derived concentration guide was exceeded by a small fraction in unfiltered samples from one well (299-E28-23) in recent years (35.4 and 40.4 pCi/L in FY 2006). The primary reason that disposal of these large quantities of transuranic radionuclides directly to the vadose zone at the Hanford Site has not resulted in widespread groundwater contamination is that under the typical oxidizing and neutral to slightly alkaline pH conditions of the Hanford vadose zone, transuranic radionuclides (plutonium and americium in particular) have a very low solubility and high affinity for surface adsorption to mineral surfaces common within the Hanford vadose zone. Other important factors are the fact that the vadose zone is typically very thick (hundreds of feet) and the net infiltration rate is very low due to the desert climate. In some cases where transuranic radionuclides have been co-disposed with acidic liquid waste, transport through the vadose zone for considerable distances has occurred. For example, at the 216-Z-9 Crib, plutonium-239 and americium-241 have moved to depths in excess of 36 m (118 ft) bgs. Acidic conditions increase the solubility of these contaminants and reduce adsorption to mineral surfaces. Subsequent neutralization of the acidity by naturally occurring calcite in the vadose zone (particularly in the Cold Creek unit) appears to have effectively stopped further migration. The vast majority of transuranic contaminants disposed to the vadose zone on the Hanford Site (10,200 Ci [86%] of plutonium-239; 27,900 Ci [97%] of americium-241; and 41.8 Ci [78%] of neptunium-237) were disposed in sites within the PFP Closure Zone. This closure zone is located within the 200 West Area (see Figures 1.1 and 3.1). Other closure zones with notably high quantities of transuranic contaminant disposal include the T Farm Zone with 408 Ci (3.5%) plutonium-239, the PUREX Zone with 330 Ci (2.8%) plutonium-239, 200-W Ponds Zone with 324 Ci (2.8%) plutonium-239, B Farm Zone with 183 Ci (1.6%) plutonium-239, and the REDOX Zone with 164 Ci (1.4%) plutonium 239. Characterization studies for most of the sites reviewed in the document are generally limited. The most prevalent characterization methods used were geophysical logging methods. Characterization of a number of sites included laboratory analysis of borehole sediment samples specifically for radionuclides and other contaminants, and geologic and hydrologic properties. In some instances, more detailed research level studies were conducted. Results of these studies were summarized in the document.
The F-Area Tank Farm (FTF) Performance Assessment (PA) utilizes waste speciation in the waste release model used in the FTF fate and transport modeling. The waste release modeling associated with the residual plutonium in Tank 18 has been identified as a primary contributor to the Tank 18 dose uncertainty. In order to reduce the uncertainty related to plutonium in Tank 18, a better understanding of the plutonium speciation in the Tank 18 waste (including the oxidation state and stoichiometry) is desired. Savannah River National Laboratory (SRNL) utilized Scanning Electron Microscopy (SEM) and X-ray Diffraction (XRD) to analyze Tank 18 samples to provide information on the speciation of plutonium in the waste material. XRD analysis of the Tank 18 samples did not identify any plutonium mineral phases in the samples. These indicates the crystalline mineral phases of plutonium are below the detection limits of the XRD method or that the plutonium phase(s) lack long range order and are present as amorphous or microcrystalline solids. SEM analysis of the Tank 18 samples did locate particles containing plutonium. The plutonium was found as small particles, usually <1 μm but ranging up to several micrometers in diameter, associated with particles of an iron matrix and at low concentration in other elemental matrices. This suggests the plutonium has an affinity for the iron matrix. Qualitatively, the particles of plutonium found in the SEM analysis do not appear to account for all of the plutonium in the sample based on concentrations determined from the chemical analysis of the Tank 18 samples. This suggests that plutonium is also distributed throughout the solids in low concentrations.
The measurement of uranium and plutonium holdup in plants during process activity and for decommissioning is important for nuclear safeguards and material control. The amount of plutonium and uranium holdup in glove-boxes, pipes, ducts, and other containers has been measured for several decades using both neutron and gamma-ray techniques. For the larger containers such as hot cells and glove-boxes that contain processing equipment, the gamma-ray techniques are limited by self-shielding in the sample as well as gamma absorption in the equipment and associated shielding. The neutron emission is more penetrating and has been used extensively to measure the holdup for the large facilities such as the MOX processing and fabrication facilities in Japan and Europe. In some case the totals neutron emission rates are used to determine the holdup mass and in other cases the coincidence rates are used such as at the PFPF MOX fabrication plant in Japan. The neutron emission from plutonium and MOX has 3 primary source terms: 1) Spontaneous fission (SF) from the plutonium isotopes, 2) The (α,n) reactions from the plutonium alpha particle emission reacting with the oxygen and other impurities, and 3) Neutron multiplication (M) in the plutonium and uranium as a result of neutrons created by the first two sources. The spontaneous fission yield per gram is independent of thickness, whereas, the above sources 2) and 3) are very dependent on the thickness of the deposit. As the effective thickness of the deposit becomes thin relative to the alpha particle range, the (α,n) reactions and neutrons from multiplication (M) approach zero. In any glove-box, there will always be two primary modes of holdup accumulation, namely direct powder contact and non-contact by air dispersal. These regimes correspond to surfaces in the glove-box that have come into direct contact with the process MOX powder versus surface areas that have not had direct contact with the powder. The air dispersal of PuO{sub 2} particles has been studied for several decades by health physicists, because the primary health hazard of plutonium is breathing the airborne particles. The air dispersal mechanism results from the smaller particles in the top layer of powder that are lifted into the air by the electrostatic charge buildup from the alpha decay process, and the air convection carries the particles to new more distant locations. If there is open plutonium powder in a glove-box, the surfaces at more distant locations will become contaminated over time. The range of an alpha particle in a solid or powder is a function of the particle energy, the material density, and the atomic number A of the material. The average energy of a plutonium alpha particle is ∼5.2 MeV and the range in air is ∼37 mm. The range in other materials can be estimated via the Bragg-Kleenman equation. For plutonium, A is 94, and the typical density for a single particle is ∼11.5 g/cm{sup 3}, but for a powder, the density would be less because of the air packing fraction. The significance of the small diameter is that the range of the alpha particle is ∼50 μm for powder density 2.5 and significantly less for a single particle with density 11.5, so the thin deposit of separate small particles will have a greatly reduced (α,n) yield. The average alpha transit length to the surface in the isolated MOX particle would be < 2.5 μm; whereas, the range of the alpha particle is much longer. Thus, most of the alpha particles would escape from the MOX particle and be absorbed by the walls and air. The air dispersal particles will have access to a large surface area that includes the walls, whereas, the powder contact surface area will be orders of magnitude smaller. Thus, the vast majority of the glove-box surface area does not produce the full (α,n) reaction neutron yield, even from the O{sub 2} in the PuO{sub 2} as well as any impurity contamination such as H{sub 2}O. To obtain a more quantitative estimate of the neutron (α,n) yields as a function of holdup deposit thickness, we have used MCNPX calculations to estimate the absorption of alpha particles in PuO{sub 2} holdup deposits. The powder thickness was varied from 0.1 μm to 5000 μm and the alpha particle escape probability was calculated. As would be expected, as the thickness approaches zero, the escape probability approaches 1.0, and as the thickness gets much greater than the alpha particle range (∼50 μm), the escape probability becomes small. Typically, the neutron holdup calibration measurement are performed using sealed containers of thick MOX that has all 3 sources of neutrons [SF, (α,n), and M], and no significant impurities. Thus, the calibration counting rates need to include corrections for M and (α,n) yields that are different for the holdup compared with the calibration samples. If totals neutron counting is used for the holdup measurements, the variability of the (α,n) term needs to be considered.
Between 1944 and 1989, the Hanford Site produced 60 percent (54.5 metric tons) of the United States weapons plutonium and produced an additional 12.9 metric tons of fuels-grade plutonium. High activity wastes, including plutonium lost from the separations processes used to isolate the plutonium, were discharged to underground storage tanks during these operations. Plutonium in the Hanford tank farms is estimated to be {approx}700 kg but may be up to {approx}1000 kg. Despite these apparent large quantities, the average plutonium concentration in the {approx}200 million liter tank waste volume is only about 0.003 grams per liter ({approx}0.0002 wt%). The plutonium is largely associated with low solubility metal hydroxide/oxide sludges where its low concentration and intimate mixture with neutron-absorbing elements (e.g., iron) are credited in nuclear criticality safety. However, concerns have been expressed that plutonium, in the form of plutonium hydrous oxide, PuO{sub 2} {center_dot} xH{sub 2}O, could undergo sufficient crystal growth through Ostwald ripening in the alkaline tank waste to potentially be separable from neutron absorbing constituents by settling or sedimentation. It was found that plutonium that entered the alkaline tank waste by precipitation through neutralization from acid solution is initially present as 2- to 3-nm (0.002- to 0.003-{mu}m) scale PuO{sub 2} {center_dot} xH{sub 2}O crystallite particles and grows from that point at exceedingly slow rates, posing no risk to physical segregation. These conclusions are reached by both general considerations of Ostwald ripening and specific observations of the behaviors of PuO{sub 2} and PuO{sub 2} {center_dot} xH{sub 2}O upon aging in alkaline solution.
This memo describes the fabrication of a polymer ligand extractant based on Eichrom's LN-1 resin. This work has been in support of the Fast Alpha Spectrometry Tool (FαST) project. The first part of LANL's role in this project is to evaluate new extractants for use in polymer ligand extractants (PLEs). The first new extractant evaluated is Di(2-ethyl hexyl) phosphoric acid (HDEHP), which is an effective metal extractant. It has very efficient chelating properties for a wide variety of metal ions. HDEHP is an amphiphillic molecule with two long hydrocarbon chains and a polar end with a phosphoryl oxygen (P=O) and an acidic -OH group as shown in Figure 1. HDEHP has shown effectiveness in extracting lanthanides, selective actinides, and other trivalent elements. Several authors have reported that lanthanides and elements with +3 oxidation state have similar extraction behavior in nitric acid. The distribution ratio for lanthanides rapidly decreases at lower nitric concentration then start to increase at higher concentration as shown in. The trivalent americium, curium, and yttrium exhibit similar trend as trivalent lanthanides. This extraction trend can be also observed from hydrogen chloride solution. This work describes the use of this ligand in a PLE to extract plutonium from solution. Polymer ligand films were prepared by dissolving HDEHP ligands and polystyrene beads in THF. The solution was directly deposited onto a 40 mm diameter stainless steel substrate using an automated pipette. HDEHP based PLEs with direct stippling method are shown in Figure 2. The solution was air dried at room temperature overnight to ensure complete evaporation of THF. The plutonium tracer solution was prepared in 0.01, 0.1, 1, and 8M nitric solutions to study the effect of nitric concentration in plutonium extraction. 0.1667 Bq 239 Pu tracer solution was directly stippled on each PLE and was allowed to equilibrate for 3 hours before removing the solution. The plutonium activity of each sample was measured by direct alpha counting to quantify the plutonium recovery by HDEHP PLE. The alpha spectra from alpha spectroscopy are shown in Figure 3. 1:5, 1:10, and 1:20 PLEs had sharp peak with low tailing. 1:2 had an extremely long tail, which is a possible indication that a large amount of ligands caused the film to not form a smooth surface. Also, it can be noted that 1:2 ratio PLE surface was not as rigid as the other ratio PLEs and it was prone to scratching during sample handing. The resolution of alpha spectra was quantified by measuring Full Width at Half of the Maximum (FWHM) using Bortels equation. The tailing component of the peak was also measured along with FWHM. The peak resolutions and tailing measurements for 0.1M nitric solution samples are given in Table 1. The best resolution was achieved with 1:5 PLE and worst was given by 1:2 PLE. The plutonium recovery by HDEHP PLE was dependent on both nitric concentration and ligand to polymer ratio. 1:2 PLE consistently had the highest recovery followed by 1:5 as shown in Figure 4. It should be noted that 1:2 ratio PLEs consistently had long tailing and the ROI of the spectrum had to be increased to encompass total counts from the tracer. 1:10 and 1:20 PLEs had close to zero percent recovery in all nitric concentration except for 0.01M. The highest plutonium recovery was observed for 0.1M nitric acid. 1:5 PLE gave the best combination of alpha spectroscopy resolution and plutonium recovery. Radiography image of samples were generated to study the plutonium distribution on the PLE surface. Samples were placed on an imaging plate (Fujifilm BAS-TR 2025) for 24 hours and the plate was scanned using GE Typhoon FLA 7000 system. The radiography image in Figure 5 shows uneven distribution with hot spots along the edge and in the center of the samples. These hot spots may be the result of highly localized concentration of ligands or surface defects that were observed in SEM. This unevenness in distribution may cause inaccurate activity measurement by alpha spectroscopy due to a bias in the energy calibration. PLEs based on HDEHP have been evaluated. The concentration of ligand in polystyrene is critical in the performance of the PLE; both for extraction efficiency as well as for alpha spectrometry results. The optimal PLE using this ligand has a concentration of 1:5 ligand to polystyrene. Under laboratory conditions, this configuration can produce similar results to those obtained for DIPEX based PLEs from previous studies. The concentration is very important to the results obtained for this ligand. This PLE is a good candidate for use in later field studies. Our next report will detail the evaluation of PLEs utilizing crown ether ligands.