Building the Fire Energetics and Emissions Research (FEER) Smoke Emissions Inventory Version 1.0

The Fire Energetics and Emissions Research (FEER) group's new coefficient of emission global gridded product at 1x1 resolution that directly relates fire readiative energy (FRE) to smoke aerosol release, FEERv1.0 Ce, made its public debut in August 2013. Since then, steps have been taken to generate corresponding maps and totals of total particulate matter (PM) emissions using different sources of FRE, and subsequently to simulate the resulting PM(sub 2.5) in the WRF-Chem 3.5 model using emission rates from FEERv1.0 as well as other standard biomass burning emission inventories. An flowchart of the FEER algorithm to calculate Ce is outlined here along with a display of the resulting emissions of total PM globally and also regionally. The modeling results from the WRF-Chem3.5 simulations are also shown.

particulate matter↗

Update on Advection-Diffusion Purge Flow Model

Gaseous purge is commonly used in sensitive spacecraft optical or electronic instruments to prevent infiltration of contaminants and/or water vapor. Typically, purge is sized using simplistic zero-dimensional models that do not take into account instrument geometry, surface effects, and the dependence of diffusive flux on the concentration gradient. For this reason, an axisymmetric computational fluid dynamics (CFD) simulation was recently developed to model contaminant infiltration and removal by purge. The solver uses a combined Navier-Stokes and Advection-Diffusion approach. In this talk, we report on updates in the model, namely inclusion of a particulate transport model.

purging↗

Global Premature Mortality Due to Anthropogenic Outdoor Air Pollution and the Contribution of Past Climate Change

Increased concentrations of ozone and fine particulate matter (PM2.5) since preindustrial times reflect increased emissions, but also contributions of past climate change. Here we use modeled concentrations from an ensemble of chemistry–climate models to estimate the global burden of anthropogenic outdoor air pollution on present-day premature human mortality, and the component of that burden attributable to past climate change. Using simulated concentrations for 2000 and 1850 and concentration–response functions (CRFs), we estimate that, at present, 470 000 (95% confidence interval, 140 000 to 900 000) premature respiratory deaths are associated globally and annually with anthropogenic ozone, and 2.1 (1.3 to 3.0) million deaths with anthropogenic PM2.5-related cardiopulmonary diseases (93%) and lung cancer (7%). These estimates are smaller than ones from previous studies because we use modeled 1850 air pollution rather than a counterfactual low concentration, and because of different emissions. Uncertainty in CRFs contributes more to overall uncertainty than the spread of model results. Mortality attributed to the effects of past climate change on air quality is considerably smaller than the global burden: 1500 (−20 000 to 27 000) deaths yr (exp -1) due to ozone and 2200 (−350 000 to 140 000) due to PM2.5. The small multi-model means are coincidental, as there are larger ranges of results for individual models, reflected in the large uncertainties, with some models suggesting that past climate change has reduced air pollution mortality.

human health↗

Satellite-Based View of the Aerosol Spatial and Temporal Variability in the Cordoba Region (Argentina) Using over Ten Years of High-Resolution Data

Space-based observations offer a unique opportunity to investigate the atmosphere and its changes over decadal time scales, particularly in regions lacking in situ and/or ground based observations. In this study, we investigate temporal and spatial variability of atmospheric particulate matter (aerosol) over the urban area of Córdoba (central Argentina) using over ten years (2003–2015) of high-resolution (1 km) satellite-based retrievals of aerosol optical depth (AOD). This fine resolution is achieved exploiting the capabilities of a recently developed inversion algorithm (Multiangle implementation of atmospheric correction, MAIAC) applied to the MODIS sensor datasets of the NASA-Terra and -Aqua platforms. Results of this investigation show a clear seasonality of AOD over the investigated area. This is found to be shaped by an intricate superposition of aerosol sources, acting over different spatial scales and affecting the region with different yearly cycles. During late winter and spring (August-October), local as well as near- and long-range transported biomass burning (BB) aerosols enhance the Córdoba aerosol load, and AOD levels reach their maximum values (>0.35 at 0.47 µm). The fine AOD spatial resolution allowed to disclose that, in this period, AOD maxima are found in the rural/agricultural area around the city, reaching up to the city boundaries pinpointing that fires of local and near-range origin play a major role in the AOD enhancement. A reverse spatial AOD gradient is found from December to March, the urban area showing AODs 40–80% higher than in the city surroundings. In fact, during summer, the columnar aerosol load over the Córdoba region is dominated by local (urban and industrial) sources, likely coupled to secondary processes driven by enhanced radiation and mixing effects within a deeper planetary boundary layer (PBL). With the support of modelled AOD data from the Modern-Era Retrospective Analysis for Research and Application (MERRA), we further investigated into the chemical nature of AOD. The results suggest that mineral dust is also an important aerosol component in Córdoba, with maximum impact from November to February. The use of a long-term dataset finally allowed a preliminary assessment of AOD trends over the Córdoba region. For those months in which local sources and secondary processes were found to dominate the AOD (December to March), we found a positive AOD trend in the Córdoba outskirts, mainly in the areas with maximum urbanization/population growth over the investigated decade. Conversely, a negative AOD trend (up to −0.1 per decade) is observed all over the rural area of Córdoba during the BB season, this being attributed to a decrease of fires both at the local and the continental scale.

aerosols↗

Lunar Dust Simulant Particle Adhesion on Copolyimide Alkyl Ethers

Mitigation of lunar dust contamination is one of the greatest challenges to be overcome to realize a sustained lunar presence. Likely solutions will integrate active mitigation strategies, requiring the input of external energy, and passive materials, exhibiting an intrinsic resistance to lunar dust adhesion. In this work, a series of copolyimide alkyl ethers containing per fluorinated side-chains were generated to evaluate the influence surface modification agents have on surface chemical, topographical, and mechanical properties. An expanded testing protocol to characterize the adhesion interaction between lunar dust simulant and the copolyimide substrate was carried out. The interfacial adhesion strength was in-situ measured by a custom-built particulate adhesion instrument, utilizing a sonic wand. Surface mechanical properties were characterized by nanoindentation, utilizing the continuous stiffness measurement approach. A nominal presence of surface modifying agents, 1 wt%, resulted in a six-fold reduction in adhesion strength of the interface. A strong inverse correlation between the adhesion strength and Young’s modulus of the substrate was identified. The reduction was attributed to a synergistic interaction between the surface energy, surface roughness, and modulus of the copolyimide alkyl ethers film.

Lunar Dust, Particulate Adhesion, Surface Migratio↗

The Relationship Between MAIAC Smoke Plume Heights and Surface PM

Biomass burning is a source of fine particulate matter (PM2.5) air pollution, which adversely impacts human health. However, quantifying the health effects from biomass burning PM2.5 is difficult. Monitoring networks generally lack the spatial density needed to capture the heterogeneity of biomass burning smoke. Satellite aerosol optical depth (AOD) can be used to fill spatial gaps but does not distinguish surface‐level aerosols. Plume height (PH) observations may provide constraints on the vertical distribution of smoke and its impact on surface concentrations. We assessed PH characteristics from Multi‐Angle Implementation of Atmospheric Correction (MAIAC) and evaluated its correlation with colocated PM2.5 and AOD measurements. PH is generally highest over the western United States. The ratio PM2.5:AOD generally decreases with increasing PH:PBLH (planetary boundary layer height), showing that PH has the potential to refine surface PM2.5 estimates for collections of smoke events.

satellite retrieved smoke plume heights↗

Impacts of Improved Process Representation of Particle Dry Deposition on PM Pollution in a Global Chemistry-Climate Model: Differences Across Regions, Seasons, and PM Sizes

Dry deposition (DD) is a primary removal pathway of particulate matter (PM). The aerosol DD schemes in most global models do not reflect current mechanistic understanding gleaned from observations. The NASA GISS global chemistry-climate model has a new and more dynamic DD scheme that largely captures observed changes in deposition velocities with particle size. We quantify the response of simulated PM to changes in the DD scheme for the Northeast US, Central Europe, North China Plain, and Punjab. Relative to the widely used old scheme, the new scheme shows higher annual PM2.5 for all regions (up to +14%) except C. Europe where there are very small decreases. For PM1, annual increases occur over all regions (up to +20%). For PM10, there are decreases in C. Europe (-8%) and very small decreases in the NE US yet increases (up to +12%) in Punjab and N. China Plain. While there are always increases across seasons for Punjab and N. China Plain, there are both seasonal increases and decreases for the NE US and C. Europe. Given incomplete understanding of observed variations in deposition velocities for a given particle size, we perform sensitivity simulations that perturb the magnitude of the deposition velocities simulated by the new scheme. The annual PM response to increasing DD is similar in magnitude to decreasing DD, implying linearity in the PM sensitivity to DD. The relative annual response to perturbing the DD magnitude is weaker over Punjab and sometimes N. China Plain than the NE US and C. Europe. Higher PM over Punjab and N. China Plain implies a stronger sensitivity to DD when aerosol abundances are low. More mechanistic representation of aerosol DD can sometimes improve or worsen existing model PM biases, which suggests that PM biases due to other processes can be confounded or compounded by biases in DD. Further improvements to DD parameterizations require not only more observational constraints on aerosol deposition velocities but also an advanced understanding of the processes controlling observed variability.

Environmental pollution↗

Assessment of the Impact of Discontinuity in Satellite Instruments and Retrievals on Global PM2.5

Exposure to fine particulate matter (PM2.5) is the leading environmental risk factor for mortality globally. Satellite-derived estimates of surface PM2.5 developed from a combination of satellites, simulations, and ground monitor data are relied upon for health impact studies. The ability to develop satellite-derived PM2.5 estimates requires the continued availability of aerosol optical depth (AOD) sources. This work examines the impact of the addition or loss of satellite AOD data sources on global PM2.5 estimation and the impact of continuing the longterm record with AOD from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi-National Polar orbiting Partnership (S-NPP) satellite after the loss of the MODIS (MODerate resolution Imaging Spectroradiometer) and MISR (Multi-angle Imaging Spectroradiometer) instruments on board the Terra and Aqua satellites. We find that the addition of VIIRS S-NPP AOD products to geophysical PM2.5 estimates from satellites and simulations causes regional differences that correspond to differences in the VIIRS and MODIS Deep Blue AOD algorithms and sampling. Changes in long-term trends and timeseries due to the addition or loss of AOD data sources are generally within their uncertainties. Statistical fusion with ground monitor data partially corrects for changes due to sampling differences when introducing the VIIRS AOD products, but uncertainty remains over desert regions where ground monitor coverage is sparse. This work provides promise for the sustained development of global satellite-derived PM2.5 estimates, despite discontinuities in instruments and retrieval methods.

Remote sensing↗

A Network of Field-Calibrated Low-Cost Sensor Measurements of PM2.5 in Lomé, Togo, Over One to Two Years

Air pollution is a leading cause of global premature mortality and is especially prevalent in many low- and middle-income countries (LMICs). In sub-Saharan Africa, preliminary monitoring networks, satellite retrievals of air-quality-relevant species, and air quality models show ambient fine particulate matter (PM 2.5 ) concentrations that far exceed the World Health Organization guidelines, yet many areas remain largely unmonitored and understudied. Deploying a network of five low-cost PurpleAir PM 2.5 monitors over 2 years (2019–2021), we present the first multiyear ambient air pollution monitoring data results from Lomé, Togo, a major West African coastal city with a population of about 1.4 million people. The full-study time period network-wide mean measured daily PM 2.5 concentration is 23.5 μ g m –3 m –3 . The strong regional influence of the dry and dusty Harmattan wind increases the local average PM 2.5 concentration by up to 58% during December through February, but the diurnal and weekly trends in PM 2.5 are largely controlled by local influences. At all sites, more than 87% of measured days exceeded the new WHO Daily PM 2.5 guidelines; these first measurements highlight the need for air quality improvement in a rapidly growing urban metropolis.

air pollution↗

Composition and Climate Impacts of Increasing Launches to Low Earth Orbit

We present simulations of an Earth system model in which launch vehicles inject gaseous and particulate combustion products into the stratosphere. We considered two plausible scenarios representative for the year 2050, one with 1000 launches per year and another with 10 times more, all of which assuming heavy lift (80 tons to low Earth orbit; LEO) launches using methane as a proxy for liquefied natural gas (LNG) fuel. An industry-standard plume flowfield model was used to predict emission of gaseous species including carbon monoxide, nitrogen oxides, and water vapor. Black carbon was introduced assuming vacuum emission equal 25% of equivalent kerosene engine. The gas emissions showed marginal or insignificant changes in atmospheric composition, while the black carbon emission was found to be the most influential component. Feedbacks involve tropopause and stratospheric warming, followed by a moistening of the stratosphere via tropospheric water vapor intrusions, together with a reduction in global albedo. The fact that LNG-fueled rockets could be a concern from aerosol emissions in our simulations, despite burning more efficiently than conventional fuels, underscores the need to better understand actual black carbon emissions from rocket engines in order to accurately predict the global impacts of launch vehicles on future climate.

Earth system model↗

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Humidity↗

Evaluation of CMIP6 Model Simulations of PM 2.5 and its Components Over China

Earth system models (ESMs) participating in the latest Coupled Model Intercomparison Project Phase 6 (CMIP6) simulate various components of fine particulate matter (PM 2.5 ) as major climate forcers. Yet the model performance for PM 2.5 components remains little evaluated due in part to a lack of observational data. Here, we evaluate near-surface concentrations of PM 2.5 and its five main components over China as simulated by 14 CMIP6 models, including organic carbon (OC; available in 14 models), black carbon (BC; 14 models), sulfate (14 models), nitrate (4 models), and ammonium (5 models). For this purpose, we collect observational data between 2000 and 2014 from a satellite-based dataset for total PM2.5 and from 2469 measurement records in the literature for PM 2.5 components. Seven models output total PM 2.5 concentrations, and they all underestimate the observed total PM 2.5 over eastern China, with GFDL-ESM4 (−1.5 %) and MPI-ESM-1-2-HAM (−1.1 %) exhibiting the smallest biases averaged over the whole country. The other seven models, for which we recalculate total PM 2.5 from the available component output, underestimate the total PM 2.5 concentrations partly because of the missing model representations of nitrate and ammonium. Concentrations of the five individual components are underestimated in almost all models, except that sulfate is overestimated in MPI-ESM-1-2-HAM by 12.6 % and in MRI-ESM2-0 by 24.5 %. The underestimation is the largest for OC (by −71.2 % to −37.8 % across the 14 models) and the smallest for BC (−47.9 % to −12.1 %). The multi-model mean (MMM) reproduces the observed spatial pattern for OC (R = 0.51), sulfate (R = 0.57), nitrate (R = 0.70) and ammonium (R = 0.74) fairly well, yet the agreement is poorer for BC (R = 0.39). The varying performances of ESMs on total PM 2.5 and its components have important implications for the modeled magnitude and spatial pattern of aerosol radiative forcing.

CMIP6↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Challenges of Air Monitoring at a Soil Remediation Project in a Suburban Setting - 20448

Air monitoring during soil excavation at a chemically and radiologically impacted site in a suburban setting presents unique challenges. Site activities were conducted in a manner that minimized the release of airborne particulates of concern, principally radionuclides of concern (ROC). Dust and air monitoring were performed to ensure the public was not being exposed to the soil contaminants. The project team collected representative air and dust data while being mindful to not impose on the lives of residents in the area. Due to the close proximity to the public, there was a high level of oversight from the client and regulatory agencies. The challenges involved with air sampling at this soil remediation site located in a suburban setting included the number of contaminants, the ranges of risks and hazards presented by the contaminants and the method of remediation, the concerns of the regulators and the public, and the perception of risk from the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗