Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multi material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Autonomous direct freeform fabrication strategy for multi-axis additive manufacturing

Multi-axis additive manufacturing (M-AM) enables precise material deposition along both planar and curved layers, eliminating the need for support structures through a continuous material deposition approach. In contrast to conventional 2-dimensional planar layers constrained to a fixed building orientation, the deposition on freeform layers demands the specification of guided curves to determine material deposition directions which are no longer to be fixed to a build direction. There are challenges that arise when fabricating components with multiple “build” directions, necessitating the decomposition of geometries and the specification of guided curves for the resulting volumes. Furthermore, multi-axis systems introduce heightened challenges due to an increased degree of freedom in motion. Consequently, the potential risks of collision between the deposited geometry and the motion platform become a notable concern. This research proposes a freeform layering algorithm to address the challenge of seamless transitions between planar and curved layers in the process planning of M-AM. The algorithm computes 3D “printable” layers by leveraging topological information derived from the geometry to be built and integrates collision-free manufacturability considerations into the computational process. These accumulated volumes serve as a “substrate” and support volumes for subsequent deposition, allowing later layers to be built without the need for additional support material. In conclusion, the proposed method successfully devises a freeform layering approach suitable for intricate models that demand substantial support, thus enabling the fabrication of diverse geometries in a manner previously unachievable.

36 MATERIALS SCIENCE↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Expression of interfacial Seebeck coefficient through grain boundary engineering with multi-layer graphene nanoplatelets

Energy filtering has been a long-sought strategy to enhance a thermoelectric material's figure of merit zT through improving its power factor. Here we show a composite of multi-layer graphene nanoplatelets (GNP) and n-type Mg 3 Sb 2 leads to the expression of an energy filtering like effect demonstrated by an increase in the material's Seebeck coefficient and maximum power factor, without impact on the material's carrier concentration. We analyse these findings from the perspective of a heterogeneous material consisting of grain and grain boundary phases, instead of a more traditional and common analysis that assumes a homogeneously transporting medium. An important implication of this treatment is that it leads to the development of an interfacial Seebeck coefficient term, which can explain the observed increase in the material's Seebeck coefficient. The contribution of this interfacial Seebeck coefficient to the overall Seebeck coefficient is determined by the relative temperature drop across the grain boundary region compared to that of the bulk material. In Te doped Mg 3 Sb 2 we show the introduction of GNP increases the interfacial thermal resistance of grain boundaries, enhancing the contribution of the interfacial Seebeck coefficient arising from grain boundaries to the overall Seebeck coefficient. Without significant detriment to the electrical conductivity this effect results in a net increase in maximum power factor. This increased interfacial thermal resistance also leads to the synergistic reduction of the total thermal conductivity. As a result, we enhance zT of the Mg 3 Sb 2 to a peak value of 1.7 near 750 K. Considering the two-dimensional nature of the grain boundary interface, this grain boundary engineering strategy could be applied to a few thermoelectric systems utilizing various two-dimensional nanomaterials.

42 ENGINEERING↗

Rapid Design and Manufacturing of High-Performance Materials for Turbine Blades

This research demonstrated the concept of carbide precipitation-strengthened refractory high entropy alloys (RHEA). The advantage of a precipitation strengthened alloy is all phases are in thermodynamic equilibrium promoting microstructural stability, and consequently retention of properties at elevated temperatures. Additionally, as with any precipitation strengthened – or age hardened - alloy, components can be heat-treated after manufacturing to manipulate the microstructure and optimize properties for performance. This is an advantage of the precipitation strengthened alloys over composites and ceramics materials, where the microstructure and properties are essentially fixed upon the initial materials manufacturing stage. High throughput (HT), multi-scale computer modeling was used to identifying novel RHEA compositions with desired characteristics needed for precipitation strengthening. Designs were validated by producing small ingots via are melting. The results showed that carbides precipitated and consequently, the strength of the alloys (measured in compression) increased after heat-treatment, which is the desired effect. The project also demonstrated the feasibility of producing articles from RHEA by additive manufacturing (AM). Electron beam melting (EBM) and laser direct energy deposition (L-DED) additive manufacturing methods, were explored with various processing parameters were interrogated for both methods. Sound (crack-free and dense) precipitation strengthened RHEA samples were produced via EDM AM, demonstrating the feasibility of the concept.

36 MATERIALS SCIENCE↗

III-V-N materials for super high-efficiency multijunction solar cells

We have been studying concentrator multi-junction solar cells under Japanese Innovative Photovoltaic R and D program since FY2008. InGaAsN is one of appropriate materials for 4-or 5-junction solar cell configuration because this material can be lattice-matched to GaAs and Ge substrates. However, present InGaAsN single-junction solar cells have been inefficient because of low minority-carrier lifetime due to N-related recombination centers and low carrier mobility due to alloy scattering and non-homogeneity of N. This paper presents our major results in the understanding of majority and minority carrier traps in GaAsN grown by chemical beam epitaxy and their relationships with the poor electrical properties of the materials.

36 MATERIALS SCIENCE↗

Hypervelocity Impact Characterization on Hubble Space Telescope Multi-Layer Insulation

Multi-layer insulation (MLI) is a common material used on rocket bodies and spacecraft to provide thermal regulation. This material is typically attached on the surface of the object in orbit and is thus exposed to the space environment and to micrometeoroid and orbital debris (MMOD) impacts. Occasionally, these exposed surfaces are returned and used by NASA’s Orbital Debris Program Office (ODPO) for analysis. When used to assess impacts on surfaces over time, materials like MLI provide an opportunity for in situ measurements to support the Orbital Debris Engineering Model (ORDEM) development and validation. During the 2009 Hubble Space Telescope (HST) Serving Mission, the MLI blankets covering the HST electronics bays 5, 8, and 10 were removed and subsequently analyzed by the ODPO in 2010. The bay 5 blanket was used in concert with ground-based hypervelocity impact tests on single layer MLI to validate the ORDEM 3.1 computer model of the OD environment, but further research was required to properly differentiate the impact features attributed to MM or OD. The ORDEM 3.1 validation effort identified several areas of further study to improve model validation and understanding of the space environment. Among these topics are the effects of underlying MLI layers on first layer impact feature characteristics, the effects of space weathering and associated damage to the surface on impact feature characteristics, and the transition from perforating to cratering regions. To better understand hypervelocity impact damage and long-term degradation of MLI surfaces, further hypervelocity impact testing was proposed and completed from 2020 to 2022. This paper discusses test conditions and parameters with resultant impact hole analyses of single layer versus multi-layered samples, space-exposed samples versus pristine, equivalent samples, and perforation versus cratering criteria in the difficult transition region. Damage equations, with associated uncertainties, are estimated from the test parameters and presented. The results of a feasibility study are described, in which the Scanning Electron Microscopy/Electron Dispersive X-ray was used to examine the MLI layers to differentiate MM and OD impacts. Finally, the extension of HST MLI outcomes and analysis methodology as it applies to future returned MLI samples is discussed.

Melissa A. Murray↗

Multi-fidelity microstructure-induced uncertainty quantification by advanced Monte Carlo methods

Quantifying uncertainty associated with the microstructure variation of a material can be a computationally daunting task, especially when dealing with advanced constitutive models and fine mesh resolutions in the crystal plasticity finite element method (CPFEM). Numerous studies have been conducted regarding the sensitivity of material properties and performance to the mesh resolution and choice of constitutive model. However, a unified approach that accounts for various fidelity parameters, such as mesh resolutions, integration time-steps and constitutive models simultaneously is currently lacking. Further, this paper proposes a novel uncertainty quantification (UQ) approach for computing the properties and performance of homogenized materials using CPFEM, that exploits a hierarchy of approximations with different levels of fidelity. In particular, we illustrate how multi-level sampling methods, such as multi-level Monte Carlo (MLMC) and multi-index Monte Carlo (MIMC), can be applied to assess the impact of variations in the microstructure of polycrystalline materials on the predictions of homogenized materials properties. We show that by adaptively exploiting the fidelity hierarchy, we can significantly reduce the number of microstructures required to reach a certain prescribed accuracy. Finally, we show how our approach can be extended to a multi-fidelity framework, where we allow the underlying constitutive model to be chosen from either a phenomenological plasticity model or a dislocation-density-based model.

36 MATERIALS SCIENCE↗

Hypervelocity Impact Characterization on Hubble Space Telescope Multi-Layer Insulation

Multi-layer insulation (MLI) is a common material used on rocket bodies and spacecraft to provide thermal regulation. This material is typically attached on the surface of the object in orbit and is thus exposed to the space environment and to micrometeoroid and orbital debris (MMOD) impacts. Occasionally, these exposed surfaces are returned and used by NASA’s Orbital Debris Program Office (ODPO) for analysis. When used to assess impacts on surfaces over time, materials like MLI provide an opportunity for in-situ measurements to support the Orbital Debris Engineering Model (ORDEM) development and validation. During the 2009 Hubble Space Telescope (HST) Serving Mission, the MLI blankets covering the HST electronics bays 5, 8, and 10 were removed and subsequently analyzed by the ODPO in 2010. The bay 5 blanket was used in concert with ground-based hypervelocity impact tests on single layer MLI to validate the ORDEM 3.1 computer model of the OD environment, but further research was required to properly differentiate the impact features attributed to MM or OD. The ORDEM 3.1 validation effort identified several areas of further study to improve model validation and understanding of the space environment. Among these topics are the effects of underlying MLI layers on first layer impact feature characteristics, the effects of space weathering and associated damage to the surface on impact feature characteristics, and the transition from perforating to cratering regions. To better understand hypervelocity impact damage and long-term degradation of MLI surfaces, further hypervelocity impact testing was proposed and completed from 2020 to 2022. This paper discusses test conditions and parameters with resultant impact hole analyses of single layer versus multi-layered samples, space-exposed samples versus pristine, equivalent samples, and perforation versus cratering criteria in the difficult transition region. Damage equations, with associated uncertainties, are estimated from the test parameters and presented. The results of a feasibility study are described, in which the scanning electron microscopy/electron dispersive x-ray was used to examine the MLI layers to differentiate MM and OD impacts. Finally, the extension of HST MLI outcomes and analysis methodology as it applies to future returned MLI samples is discussed.

Melissa A Murray↗

Snapshot of Active Flow Control Research at NASA Langley

NASA Langley is aggressively investigating the potential advantages of active flow control as opposed to more traditional aerodynamic techniques. Many of these techniques will be blended with advanced materials and structures to further enhance payoff. Therefore a multi-disciplinary approach to technology development is being attempted that includes researchers from the more historical disciplines of fluid mechanics. acoustics, material science, structural mechanics, and control theory. The overall goals of the topics presented are focused on advancing the state of knowledge and understanding of controllable fundamental mechanisms in fluids rather than on specific engineering problems. An organizational view of current research activities at NASA Langley in active flow control as supported by several programs such as the Morphing Project under Breakthrough Vehicle Technologies Program (BVT). the Ultra-Efficient Engine Technology Program (UEET), and the 21st Century Aircraft Technology Program (TCAT) is presented. On-center research as well as NASA Langley funded contracts and grants are discussed at a relatively high level. The products of this research, as part of the fundamental NASA R and D (research and development) program. will be demonstrated as either bench-top experiments, wind-tunnel investigations, or in flight tests. Later they will be transferred to more applied research programs within NASA, DOD (Department of Defense), and U.S. industry.

Washburn, A. E.↗

Study of Surface Character of Micrometer-Scale Dipole-Exchange Spin Waves in an Yttrium Iron Garnet Film

We demonstrate that micrometer scale spin waves can be excited in a thin film of the ferrimagnetic material Yttrium Iron Garnet (YIG) using patterned, multi-element, antennas. The magnitude of dynamic magnetic field generated by such antennas decays exponentially along the thickness direction and this leads to an enhanced coupling to modes having a surface-like character as opposed to a more sinusoidal bulk-like character. We have used this property to identify spin waves having a mixed bulk/surface character.

36 MATERIALS SCIENCE↗

Measurement of anode surface temperature in carbon nanomaterial production by arc discharge method

Highlights: • We measured the temperature of anode surface by two-color pyrometry combined with a high speed camera successfully. • Growth temperature of pyrolytic graphite, MWNTs, and nano-graphite particles were in ranges of 2400–2600 K, 2600–2700 K, and 2700–3500 K, respectively. • High temperature contributes to form thermodynamically unstable material. - Abstract: Nano-graphite particles, multi-wall carbon nanotube (MWNT), and pyrolytic graphite were prepared at different positions of the anode surface in an arc discharge. Graphite electrodes were employed for the arc discharge under helium environment at atmospheric pressure. Nano-sized carbon products were characterized by scanning electron microscopy and transmission electron microscopy. During the arc discharge, two-color pyrometry combined with a high-speed camera was conducted to measure the temperature distribution of the anode surface. The growth temperature of pyrolytic graphite, MWNT, and nano-graphite particles were in the ranges of 2400–2600 K, 2600–2700 K, and 2700–3500 K, respectively. The local temperature of anode surface is a critical parameter to determine the products with different morphologies. The formation mechanism of these carbon nanomaterials is suggested based on the local temperature of anode surface and their thermodynamic stability.

36 MATERIALS SCIENCE↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

A magnon band analysis of GdRu 2 Si 2 in the field-polarized state

Understanding the formation of skyrmions in centrosymmetric materials is a problem of fundamental and technological interest. GdRu 2 Si 2 is a candidate material that hosts a variety of multi-Q magnetic phases, including in zero-field. Here, inelastic neutron scattering is used to measure the spin excitations in the field-polarized phase of GdRu 2 Si 2 . Linear spin wave theory and a method of interaction invariant path analysis are used to derive a Hamiltonian accounting for the spectra. The Hamiltonian, dominated by bilinear (Ruderman-Kittel-Kasuya-Yosida) Heisenberg exchange, compares favorably to ab initio calculations. Dipolar interactions are a secondary energy scale to consider, with J D.D ~ 0.05 J RKKY . However, it is shown that in the field-polarized phase the dipolar interactions ‘self screen’ so that their effect is largely suppressed. No specific evidence for higher-order exchange is found. These aspects are discussed in the context of the lower field multi-Q states and the anisotropy of the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deep material network via a quilting strategy: visualization for explainability and recursive training for improved accuracy

Recent developments integrating micromechanics and neural networks offer promising paths for rapid predictions of the response of heterogeneous materials with similar accuracy as direct numerical simulations. The deep material network is one such approaches, featuring a multi-layer network and micromechanics building blocks trained on anisotropic linear elastic properties. Once trained, the network acts as a reduced-order model, which can extrapolate the material’s behavior to more general constitutive laws, including nonlinear behaviors, without the need to be retrained. However, current training methods initialize network parameters randomly, incurring inevitable training and calibration errors. Here, we introduce a way to visualize the network parameters as an analogous unit cell and use this visualization to “quilt” patches of shallower networks to initialize deeper networks for a recursive training strategy. The result is an improvement in the accuracy and calibration performance of the network and an intuitive visual representation of the network for better explainability.

97 MATHEMATICS AND COMPUTING↗

Hardware Autonomy for Space Infrastructure

NASA prioritizes autonomous systems development with the expectation that it will continue to drive significant improvements in human and science exploration capability. Crew operations benefit from a spectrum of machine assistance to complete replacement of dangerous or highly repetitive tasks. Many science operations have a teleoperation component, and similarly benefit from a range of autonomy implementations that make long distance applications feasible. As we consider longer duration deep space missions, we also consider higher levels of autonomy in order meet emergent safety, maintenance, and logistics needs. One of the challenges within this scope is installation and maintenance of infrastructure, such as large scale instrumentation and communications equipment, crew habitats, and operational facilities. We describe how a programmable meta-material architecture may shift the paradigm of how we design, build, and operate future space infrastructure and assets. A primary objective of this strategy is to free the design space from launch vehicle constraints and fundamentally shift how a mission is designed and conducted. This integrates advances in materials (mechanical meta-materials), manufacturing (cooperative mobile robotics), and autonomy (multi-agent planning algorithms). Engineering systems that utilize a modular and reconfiguration building block approach, such as digital communication and computation systems, currently lead in terms of size and complexity scalability. NASA is extending the benefits and flexibility of digital systems to hardware systems, to optimize materials life-cycle management and expand our space exploration mission capabilities to meet long duration and deep space infrastructure needs, in accordance with long term NASA goals of "in-space reliance" and "mass-less exploration."

In space assembly↗