Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Aerodynamic characteristics of a vane flow angularity sensor system capable of measuring flight path accelerations for the Mach number range from 0.40 to 2.54

The aerodynamic characteristics of the angle of attack vane and the angle of sideslip vane are summarized. The test conditions ranged in free stream Mach number from 0.40 to 2.54, in angle of attack from -2 deg to 22 deg, in angle of sideslip from -2 deg to 12 deg, and in Reynolds number from 590,000 per meter to 1.8 million per meter. The results of the wind tunnel investigation are compared with results obtained with similar vane configurations. Comparisons with a NACA vane configuration are also made. In addition, wind tunnel-derived upwash for the test installation is compared with analytical predictions.

Sakamoto, G. M.↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EGS Collab Testbed 1: Second Set Tracer Test Results

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. The first multi-well experimental site was established at the 4850 level in the Homestake Mine in Lead, South Dakota, where hydraulic fractures were created at an injection well drilled sub-horizontal from the drift. This file contains the second set of tracer data (also include the data uploaded previously, https://gdr.openei.org/submissions/1128) for the EGS Collab testbed. The tracer tests were conducted during October 2018 - November 2019. Injected tracers include DNA, C-dots (fluorescein nano particles), fluorescein, rhodamine-b, sodium chloride, lithium bromide and cesium iodine. The tracers have been detected in three flowing wells located about 7.5 to 9 meters away from the injection interval. The tracer breakthrough curves from these locations have been adjusted to account for the residence time in the injection and production tubing. The details about the tracer test can be found in Background and Methods of Tracer Tests (Mattson et al. (2019,a,b)) (also included in this package). References Mattson, E.D., Neupane, G., Plummer, M.A., Hawkins, A., Zhang, Y. and the EGS Collab Team 2019a. Preliminary Collab fracture characterization results from flow and tracer testing efforts. In Proceedings 44th Workshop on Geothermal Reservoir Engineering, edited, Stanford University, Stanford, California. Mattson, E.D., Neupane, G., Hawkins, A., Burghardt, J., Ingraham, M., Plummer, M., and the EGS Collab Team, 2019b. Fracture tracer injection response to pressure perturbations at an injection well. GRC Transactions, Vol. 43, 2019. Neupane, Ghanashyam, Earl Mattson, Adam Hawkins, Mitchell Plummer, and Yuran Zhang. EGS Collab Testbed 1: Tracer data sets. No. 1128. DOE Geothermal Data Repository; Idaho National Laboratory, 2019.

15 GEOTHERMAL ENERGY↗

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

Surface and Downhole Prospecting Tools for Planetary Exploration: Tests of Neutron and Gamma Ray Probes - Research Paper

The ability to locate and characterize icy deposits and other hydrogenous materials on the Moon and Mars will help us understand the distribution of water and, therefore, possible habitats at Mars, and may help us locate primitive prebiotic compounds at the Moon’s poles. We have developed a rover-borne neutron probe that localizes a near-surface icy deposit and provides information about its burial depth and abundance. We have also developed a borehole neutron probe to determine the stratigraphy of hydrogenous subsurface layers while operating within a drill string segment. In our field tests, we have used a neutron source to “illuminate” surrounding materials and gauge the instruments’ efficacy, and we can simulate accurately the observed instrument responses using a Monte Carlo nuclear transport code (MCNPX). An active neutron source would not be needed for lunar or martian near-surface exploration: cosmic-ray interactions provide sufficient neutron flux to depths of several meters and yield better depth and abundance sensitivity than an active source. However, for deep drilling (>10 m depth), a source is required. We also present initial tests of a borehole gamma ray lithodensity tool and demonstrate its utility in determining soil or rock densities and composition.

58 GEOSCIENCES↗

Performance of LI-1542 reusable surface insulation system in a hypersonic stream

The thermal and structural performance LI-1542 reusable surface insulation (RSI) tiles was investigated. The test panel was designed to represent part of the surface structure on a space shuttle orbiter fuselage along a 1250 K isotherm. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1820 K, Reynolds numbers of 2 millon and 5 million per meter, and dynamic pressures of 26 and 65 kPa. The RSI tiles demonstrated good thermal protection and structural integrity. High temperatures were caused by misalinement in tile height, offset the tile longitudinal alinement, and leakage around thermal seals when differential pressure existed across the panel. The damage tolerance of LI-1542 RSI appeared high. The tile coating crazed early in the test program, but this did not effect the tile integrity. Erosion of the tile edges occurred at forward-facing steps and at the ends of longitudinal gaps because of particle impacts and flow shear.

Hunt, L. R.↗

SU-G-IeP3-01: Better Kerma-Area-Product (KAP) Estimation Using the System Parameters in Radiography and Fluoroscopy

Purpose: Accurate values for Kerma-Area-Product (KAP) are needed for patient dosimetry and quality control for exams utilizing radiographic and/or fluoroscopic imaging. The KAP measured using a typical direct KAP meter built with parallel-plate transmission ionization chamber is not precise and depends on the energy spectrum of diagnostic x-rays. This study compared the accuracy and reproducibility of KAP derived from system parameters with values measured with a direct KAP meter. Methods: IEC tolerance for displayed KAP is specified up to ± 35% above 2.5 Gy-cm{sup 2} and manufacturer’s specifications are typically ± 25%. KAP values from the direct KAP meter drifts with time leading to replacement or re-calibration. More precise and consistent KAP is achievable utilizing a database of known radiation output for various system parameters. The integrated KAP meter was removed from a radiography system. A total of 48 measurements of air kerma were acquired at x-ray tube potential from 40 to 150 kVp with 10 kVp increment using ion chamber type external dosimeter at free-in-air geometry for four different types of filter combinations following the manufacturer’s service procedure. These data were used to create updated correction factors that determine air kerma computationally for given system parameters. Results of calculated KAP were evaluated against results using a calibrated ion chamber based dosimeter and a computed radiography imaging plate to measure x-ray field size. Results: The accuracy of calculated KAP from the system parameters was better within 4% deviation in all diagnostic x-ray tube potentials tested from 50 to 140 kVp. In contrast, deviations of up to 25% were measured from KAP displayed from the direct KAP meter. Conclusion: The “calculated KAP” approach provides the nominal advantage of improved accuracy and precision of displayed KAP as well as reduced cost of calibrating or replacing integrated KAP meters.

60 APPLIED LIFE SCIENCES↗

Developing Separate Effects Transient Test Experiments Using an Out-of-Pile Flowing Water Loop

In 2017 the Transient Reactor Test Facility was restarted after being placed in a standby state since 1994. This Test Reactor’s restart has since enabled the progressive development of new nuclear technologies within the U.S. that were previously required to outsource to other countries. While the reactor’s restart was a large feat worthy of recognition, the experimental use of its characteristics has required the further development of in-pile experimental infrastructure sufficient to support programmatic needs. This hardware have taken the form of capsule designs (compact and elongated) as well as loop concepts representing the phenomena of interest for a subset of separate effects tests desire for each respective testing campaign. The Transient Testing Program has a large-integrated effort that aligns with the U.S. Department of Energy’s current needs. This study compliments those programmatic elements by developing, fabricating and demonstrating a full-scale flowing water loop in an out-of-pile environment. The goal of this effort is to develop a pragmatic understanding of the engineering capabilities and limitations associated with geometric form-factors, metering technology, and controls logic under representative thermal hydraulic conditions that would be experienced within the TREAT reactor during an in-pile reactivity initiated accident test. The outcomes of this study result in an evaluation of the conceptual design of a comprehensive flowing water loop including objective figures of merit (FoMs) for comparing unique instrumentation and the basis for their selection during operations. These efforts directly contribute to and are required for the further advancement of transient testing capabilities within the U.S.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spatially Dependent Seismic Wavefield Scattering from an Underground Chemical Explosion: Analysis of the Source Physics Experiment Dry Alluvium Geology Large- N Array

Explosion sources have been observed to generate significant shear‐wave energy despite their isotropic nature. To investigate this phenomenon, we conduct an analysis of the seismic data collected as part of the Source Physics Experiment (SPE): Dry Alluvium Geology (DAG) and investigate the generation of shear‐wave energy via scattering. The data were produced by three underground chemical explosions and consist of three‐component seismograms, which were recorded by the DAG Large‐N array. Synthetic tests suggest that for the DAG experiments, small‐scale stochastic heterogeneities, defined as features with correlation lengths of 10–100s of meters, are more effective than large‐scale geologic structure (scales >1–10 km) at reproducing the scattering of explosion generated wavefields observed at DAG. We analyze the seismic data for spatially variable ratios between transversely and radially polarized seismic energy, and then estimate the mean free path of P and S waves. All analyses are conducted within a frequency band of 5–50 Hz. The ratio of transversely to radially polarized energy is the highest in the east and west portion of the Large‐N array. In addition, the magnitude of the estimated S‐wave mean free path is shorter in the eastern portion of the Large‐N array. This variation indicates that the eastern area of the DAG array is where more scattering is occurring, suggesting azimuthal dependence of P‐to‐P and P‐to‐S scattering. Furthermore, this azimuthal dependence of P‐to‐S scattering can have implications for explosion discrimination based on spectral ratios of seismic wave types, because the general assumption is that explosions do not generate shear‐wave energy. Synthetic tests modeling only larger‐scale geologic structure had lower transversely polarized energy (only four stations showing a transversely to radially polarized energy ratio greater than 1) and fewer stations (<10) displaying shorter (<300 m) mean free paths than what was observed in the DAG data results.

Darrh, Andréa Nicole↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration Tunnel for High Speed

For the nvestigation of measuring instruments at higher speeds up to a Mach number 0.7 a tunnel with closed test section was built in 1942 which was as simple and cheap as possble. The blower was a radial blower with straight sheet vanes of 800-millimeter diameter the tips of which were bent backward a little. The blower sucks the air through a honeycomb of diameter 1.2 neter with wide meshes. The air is then accelerated in a short cone with smooth transition to the test section. The cylindrical test section of 200-milimeter diameter has two windows (which are displaced 180 deg from each other. The instruments may be introduced and observed through and observed through these windows. . The cross section is then enlarged by a straight diffuser 3.5 meters long and reaches the ninefold cross section. The air flows back into the room through a disk diffuser of 2-meter diameter. The maximum speed in the jet is 250 m/s for a drive power of 35 kT., if there are no installations in the jet. The velocity is determined by pressure holed along the test section.

Pretsch, J.↗

Blade Motion and Bouncing Tests of KD-1 Autogiro

There are forwarded herewith the results of blade motion and bouncing tests on the Kellett KD-1 three-bladed autogiro. Motion picture records and two-component accelerometer records were taken in flight during glides at air speeds from 30 miles per hour to 100 miles per hour indicator readings. Calibration curves of correct indicated air speed and rotor speed as functions of air speed meter reading were established with a trailing pitot-static head and a rotoscope, at 2,000 ft. altitude and an air density of 0.00231 slug/ cu. ft., all tests being made at approximately that density.

Wheatley, John B.↗

Infrared Submillimeter and Radio Astronomy Research and Analysis Program

This program entitled "Infrared Submillimeter and Radio Astronomy Research and Analysis Program" with NASA-Ames Research Center (ARC) was proposed by the Smithsonian Astrophysical Observatory (SAO) to cover three years. Due to funding constraints only the first year installment of $18,436 was funded, but this funding was spread out over two years to try to maximize the benefit to the program. During the tenure of this contact, the investigators at the SAO, Drs. Wesley A. Traub and Nathaniel P. Carleton, worked with the investigators at ARC, Drs. Jesse Bregman and Fred Wittebom, on the following three main areas: 1. Rapid scanning SAO and ARC collaborated on purchasing and constructing a Rapid Scan Platform for the delay arm of the Infrared-Optical Telescope Array (IOTA) interferometer on Mt. Hopkins, Arizona. The Rapid Scan Platform was tested and improved by the addition of stiffening plates which eliminated a very small but noticeable bending of the metal platform at the micro-meter level. 2. Star tracking Bregman and Wittebom conducted a study of the IOTA CCD-based star tracker system, by constructing a device to simulate star motion having a specified frequency and amplitude of motion, and by examining the response of the tracker to this simulated star input. 3. Fringe tracking. ARC, and in particular Dr. Robert Mah, developed a fringe-packet tracking algorithm, based on data that Bregman and Witteborn obtained on IOTA. The algorithm was tested in the laboratory at ARC, and found to work well for both strong and weak fringes.

Traub, Wesley A.↗

Biomarkers Detection With the Autonomous and Remotely Operated SOLID-LDChip Instrument in A Mars Drilling Simulating Campaign

One of the main goals in Mars exploration is to determine whether life has ever existed on the red planet. To achieve this goal, it is important to verify the performance, robustness, and maturity of instrumentation devoted to life detection, for example through field-testing in Mars analog environments.The Atacama Desert is considered one of the best terrestrial analogs of the surface of Mars due to abrupt temperature shifts, dryness, high UV radiation, and extremely low biomass. This, together with the lack of vegetation and the geochemistry of the regolith, make it an ideal scenario for testing instrumentation, performance, and concepts of operations. The Atacama Rover Astrobiology Drilling Studies (ARADS) is a NASA PSTAR project conceived for maturing and testing life-detection instrumentation in the Atacama Desert(1). The project is based on the K-REX2 rover equipped with a robotic 1-meter arm that delivers samples toon board instruments. This includes SOLID3.1 (Signs of Life Detector), designed as a life-detection instrument for finding complex organic molecules by means of the LDCHip (Life Detector Chip), an antibody microarray sensor(2). The instrument can extract organic compounds from soil, rocks, and sediments into a liquid solvent in the extraction cell (EC), allowing the search for hundreds of microbial molecular biomarkers at once (3). The robustness and reliability of SOLID were tested in the 2019 ARADS Mars drilling simulating campaign and confirmed with other analytical methods.

M Moreno-Paz↗

DEMONSTRATION OF THE NEXT-GENERATION TCAP HYDROGEN ISOTOPE SEPARATION PROCESS

The first generation of TCAP hydrogen isotope separation process has been in service for tritium separation at the Savannah River Site since 1994. To prepare for replacement, a next-generation TCAP process has been developed. This new process simplifies the column design and reduces the equipment requirements of the thermal cycling system. An experimental twelve-meter column was fabricated and installed in the laboratory to demonstrate its performance. This new design and its initial test results were presented at the 8th International Conference on Tritium Science and Technology and published in the proceedings. We have since completed the startup and demonstration the separation of protium and deuterium in the experimental unit. The unit has been operated for more than 200 cycles. A feed of 25% deuterium in protium was separated into two streams each better than 99.7% purity.

07 ISOTOPE AND RADIATION SOURCES↗

Distributed Sapphire Fiber Bragg Gratings Based Thermal Profiling of Submerged Entry Nozzles

This research focuses on the application of sapphire fiber Bragg gratings (FBGs) for instrumentation in submerged entry nozzles (SEN) within the steelmaking industry. The SEN is pivotal for transferring molten steel from a tundish to a mold, while preventing the infiltration of oxygen and nitrogen from the surrounding environment. Maintaining optimal flow conditions in the mold is crucial for ensuring casting process stability and maintaining high quality steel. Sapphire FBG sensors have been instrumented in SENs to enable distributed thermal mapping for monitoring the health of the SEN. The optical sensor comprises three cascaded sapphire FBGs inscribed using femtosecond laser technology into a one-meter-long sapphire crystalline fiber. The sensor underwent characterization in a laboratory setting up to 1600°C and was tested for long-term stability over 40 hours under extreme environmental conditions. The coupling between silica and sapphire fibers was investigated and implemented during sensor packaging. Here, the sensor successfully captured the pre-heat sequence of the SEN in real-world steelmaking operations. Compared to conventional thermocouples, sapphire FBG sensors demonstrated exceptional efficiency and precision. They offer potential benefits such as increased productivity, reduced energy consumption, and minimized carbon footprint in the steel industry.

Sapphire Fiber Bragg Grating↗

Techniques For Injection Of Pre-Charaterized Dust Into The Scrape Off Layer Of Fusion Plasma

Introduction of micron-sized dust into the scrape-off layer (SOL) of a plasma has recently found many applications aimed primarily at determining dust behavior in future fusion reactors. The dust particles are typically composed of materials intrinsic to a fusion reactor. On DIII-D and TEXTOR carbon dust has been introduced into the SOL using a probe inserted from below into the divertor region. On NSTX, both Li and tungsten dust have been dropped from the top of the machine into the SOL throughout the duration of a discharge, by utilizing a vibrating piezoelectric based particle dropper. The original particle dropper was developed to inject passivated Li powder {approx} 40 {mu}m in diameter into the SOL to enhance plasma performance. A simplified version of the dropper was developed to introduce trace amounts of tungsten powder for only a few discharges, thus not requiring a large powder reservoir. The particles emit visible light from plasma interactions and can be tracked by either spectroscopic means or by fast frame rate visible cameras. This data can then be compared with dust transport codes such as DUSTT to make predictions of dust behavior in next-step devices such as ITER. For complete modeling results, it is desired to be able to inject pre-characterized dust particles in the SOL at various known poloidal locations, including near the vessel midplane. Purely mechanical methods of injecting particles are presently being studied using a modified piezoelectric-based powder dropper as a particle source and one of several piezo-based transducers to deflect the particles into the SOL. Vibrating piezo fans operating at 60 Hz with a deflection of {+-}2.5 cm can impart a significant horizontal boost in velocity. The highest injection velocities are expected from rotating paddle wheels capable of injecting particles at 10's of meters per second depending primarily on the rotation velocity and diameter of the wheel. Several injection concepts have been tested and will be discussed below.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a ballute decelerator towed behind a jet airplane

An F-104B airplane was modified to investigate the drag and stability characteristics of a ballute decelerator in the wake of an asymmetrical airplane. Decelerator deployments were initiated at a Mach number of 1.3 and an altitude of 15,240 meters (50,000 feet) and terminated when the airplane had decelerated to a Mach number of 0.5. The flight tests indicated that the decelerator had a short inflation time with relatively small opening forces. The drag levels attained with the subject decelerator were less than those obtained with other high-speed decelerators behind a symmetrical tow vehicle. The ballute demonstrated good stability characteristics behind the testbed airplane.

Pyle, J. S.↗