Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Technology Solutions Case Study: Overcoming Comfort Issues Due to Reduced Flow Room Air Mixing

Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. In this project, IBACOS studied when HVAC equipment is downsized and ducts are unaltered to determine conditions that could cause a supply air delivery problem and to evaluate the feasibility of modifying the duct systems using minimally invasive strategies to improve air distribution.

AIR DISTRIBUTION↗

Multiphase reacting flow modeling of singlet oxygen generators for chemical oxygen iodine lasers.

Singlet oxygen generators are multiphase flow chemical reactors used to generate energetic oxygen to be used as a fuel for chemical oxygen iodine lasers. In this paper, a theoretical model of the generator is presented along with its solutions over ranges of parameter space and oxygen maximizing optimizations. The singlet oxygen generator (SOG) is a low-pressure, multiphase flow chemical reactor that is used to produce molecular oxygen in an electronically excited state, i.e. singlet delta oxygen. The primary product of the reactor, the energetic oxygen, is used in a stage immediately succeeding the SOG to dissociate and energize iodine. The gas mixture including the iodine is accelerated to a supersonic speed and lased. Thus the SOG is the fuel generator for the chemical oxygen iodine laser (COIL). The COIL has important application for both military purposes--it was developed by the US Air Force in the 1970s--and, as the infrared beam is readily absorbed by metals, industrial cutting and drilling. The SOG appears in various configurations, but the one in focus here is a crossflow droplet generator SOG. A gas consisting of molecular chlorine and a diluent, usually helium, is pumped through a roughly rectangular channel. An aqueous solution of hydrogen peroxide and potassium hydroxide is pumped through small holes into the channel and perpendicular to the direction of the gas flow. So doing causes the solution to become aerosolized. Dissociation of the potassium hydroxide draws a proton from the hydrogen peroxide generating an HO{sub 2} radical in the liquid. Chlorine diffuses into the liquid and reacts with the HO{sub 2} ion producing the singlet delta oxygen; some of the oxygen diffuses back into the gas phase. The focus of this work is to generate a predictive multiphase flow model of the SOG in order to optimize its design. The equations solved are the so-called Eulerian-Eulerian form of the multiphase flow Navier-Stokes equations wherein one set of the equations represents the gas phase and another equation set of size m represents the liquid phase. In this case, m is representative of the division of the liquid phase into distinct representations of the various droplet sizes distributed in the reactor. A stabilized Galerkin formulation is used to solve the equation set on a computer. The set of equations is large. There are five equations representing the gas phase: continuity, vector momentum, heat. There are 5m representing the liquid phase: number density, vector momentum, heat. Four mass transfer equations represent the gas phase constituents and there are m advection diffusion equations representing the HO{sub 2} ion concentration in the liquid phase. Thus we are taking advantage of and developing algorithms to harness the power of large parallel computing architectures to solve the steady-state form of these equations numerous times so as to explore the large parameter space of the equations via continuation methods and to maximize the generation of singlet delta oxygen via optimization methods. Presented here will be the set of equations that are solved and the methods we are using to solve them. Solutions of the equations will be presented along with solution paths representing varying aerosol loading-the ratio of liquid to gas mass flow rates-and simple optimizations centered around maximizing the oxygen production and minimizing the amount of entrained liquid in the gas exit stream. Gas-entrained liquid is important to minimize as it can destroy the lenses and mirrors present in the lasing cavity.

42 ENGINEERING↗

Coupled Thermo-Hydrological-Mechanical-Chemical Behavior of Anisotropic Granite for Geologic Disposal of High-Level Radioactive Waste: A Core-Scale Laboratory Investigation

The coupled thermo-hydrological-mechanical-chemical (THMC) behavior of rock within an Excavation Damaged Zone (EDZ) is critical for the safety and long-term performance of a geological repository for high-level radioactive wastes. While many laboratory experiments have been conducted to investigate EDZ rocks, the flow and deformation characteristics resulting from anisotropic rock textures and microcrack distribution under triaxial loading and elevated temperatures remain poorly understood. Particularly, cracks at various scales serve as fast paths for fluid flow and solute transport and present as focal points of mechanical weakness, which complicate the coupled THMC processes in anisotropic EDZ rocks and challenge modeling predictions. Here, in this study, a series of core-scale experiments was conducted on three granite samples under repository-relevant conditions. These rock samples were obtained from the Grimsel Underground Research Laboratory (URL), featured by anisotropic minerals (represented by bedding layers) and microcrack distributions and coarse cm-scale grain sizes. During the experiments, samples were subjected to an elevated temperature at 90 °C and different triaxial loading conditions either by radial (normal to bedding layers) or axial (parallel to bedding layers) compaction. Water was injected into the samples, and the rock permeability evolutions and effluent water chemistry were monitored closely. For intact samples, thermal expansion of minerals at 90 °C resulted in a large, 75% irreversible permeability reduction and rock strengthening under radial compaction, while thermal impact was limited to a 15% permeability reduction under axial compaction. In contrast, for a sample containing open cracks, the growth of fractures during the experiment resulted in an abrupt permeability increase and fast failure at 90 °C. The effluent water chemistry indicates much more considerable mineral dissolution from large shear sliding than that in rocks dominated by mechanical compaction. These results helped better understand the coupled THMC processes in anisotropic rocks containing cracks, evaluate the behaviors of EDZ rocks, and predict the long-term evolution of EDZ for the performance of the repositories.

Coupled THMC processes↗

A concurrent irradiation-mechanics multiscale coupling model

The vast majority of our current knowledge regarding the basic mechanisms controlling irradiation effect on mechanical properties is based almost entirely on the results of post-irradiation experiments or theoretical models. However, the concurrent effects of irradiation, mechanical stress, and thermal damage on the failure phenomena of materials and components remain largely unexplored due to its internal multiscale-multiphysics coupling nature. Here, we present here a concurrent irradiation-mechanics multiscale coupling model. The concurrent evolutions of nanoscale irradiation defect clusters, microscale dislocation configurations, and mechanical responses are well captured based on coupling cluster dynamics, discrete dislocation dynamics, and the finite element methods using an effective time marching scheme. Model predictions of defect densities and size are in general agreement with experimental observations. Irradiation hardening is shown to take place also in samples undergoing concurrent irradiation-mechanical loading, similar to samples tested post-irradiation. However, the occurrence of plastic flow localization and dislocation channel formation is not accompanied with apparent yield drop (softening) under concurrent irradiation-mechanical loading conditions, which is different from the post-irradiation case.

42 ENGINEERING↗

Characterizing the Subsurface Using Deformation from Pumping and Surface Loading Tests

Changes in pore pressure or applied load cause deformation that can be used to characterize the subsurface. A series of field tests were conducted by measuring the deformation and pressure response from a variety of stresses at our test site in South Carolina. The site is underlain by saprolite to a depth of 30 m, and the water table in the unconfined aquifer occurs at a depth of 9 m. The types of tests performed included constant-rate pumping tests and surface point loading tests using the weight of a person or vehicle. Vertical displacement of the saprolite in response to these stresses was measured at depths of 3, 6, 9 and 11 meters in both saturated and unsaturated conditions using an extensometer with a resolution of +/- 10 nm. Results from 2.5-hr-long constant-rate pumping tests indicate a repeatable, compressive vertical strain of roughly 0.1 microstrain in the vadose zone and 1-10 microstrain in the saturated zone. Drawdown was 5 m in the pumping well and 0.1 m in a nearby (r = 9m) observation well. Under saturated conditions, the strain rate gradually decreased throughout the test in a pattern that resembles the drawdown curve in the monitoring well. In contrast, the strain in the vadose zone increased quickly early in the test, but the strain rate diminished and was negligible after approximately 30 minutes of pumping. Interestingly, drawdown in the pumping well also increased quickly over 30 minutes and remained roughly constant after that. Additional tests were conducted by applying a load (weight of a person or vehicle) at the ground surface above the extensometer and allowing the signal to stabilize before removing the load. In the vadose zone, the soil compressed rapidly and then stabilized. In the saturated zone, sudden compression was followed by additional compression at a much slower rate. A similar response was observed upon removal of the load. This transient signal in the saturated zone is interpreted to be a poroelastic effect. When a load is applied, the solid skeleton compresses and pressurizes the pore fluid, causing flow. The strain rate is then a function of pressure diffusion. Simulation of the deformation from both pumping and loading tests using an unsaturated, poroelastic finite-element model indicates that strains are sensitive to the Young’s modulus and hydraulic conductivity as functions of saturation.

well tests, strain, surface loading, hydromechanic↗

Steady vibrations of wing of circular plan form

This paper treats the problem of determining the lift, moment, and induced drag of a thin wing of circular plan form in uniform incompressible flow on the basis of linearized theory. As contrasted to a similar paper by Kinner, in which the acceleration potential method was used, the present paper utilizes the concept of the velocity potential. Calculations of the lift and moment are presented for several deformed shapes. It is shown that considerable deviations exist between the strip theory analysis and the more exact theory. The lift, moment, and induced drag are also determined for a harmonically oscillatory circular plan form wing. As contrasted to a similar paper by Schade, in which the acceleration potential method was used, the present paper utilizes the concept of the velocity potential. Expressions for lift, moment, and induced drag are given and finally specialized to the case of a slowly oscillating circular wing.

FLUTTER - WINGS↗

Removing Cs within a continuous flow set-up by an ionic exchanger material transformable into a final waste form

Silica monoliths loaded with hexacyanoferrate (HCF) nanoparticles were designed and synthesized to selectively remove Cs + ions from an aqueous saline solution within a continuous flow set-up. The decontamination and hydrodynamic efficiency of this smart material was compared to other granularly supported HCF. Finally, a thermal treatment was applied to transform the HCF functionalized monolith into a final waste form matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hypersonic Engine Leading Edge Experiments in a High Heat Flux, Supersonic Flow Environment

A major concern in advancing the state-of-the-art technologies for hypersonic vehicles is the development of an aeropropulsion system capable of withstanding the sustained high thermal loads expected during hypersonic flight. Three aerothermal load related concerns are the boundary layer transition from laminar to turbulent flow, articulating panel seals in high temperature environments, and strut (or cowl) leading edges with shock-on-shock interactions. A multidisciplinary approach is required to address these technical concerns. A hydrogen/oxygen rocket engine heat source has been developed at the NASA Lewis Research Center as one element in a series of facilities at national laboratories designed to experimentally evaluate the heat transfer and structural response of the strut (or cowl) leading edge. A recent experimental program conducted in this facility is discussed and related to cooling technology capability. The specific objective of the experiment discussed is to evaluate the erosion and oxidation characteristics of a coating on a cowl leading edge (or strut leading edge) in a supersonic, high heat flux environment. Heat transfer analyses of a similar leading edge concept cooled with gaseous hydrogen is included to demonstrate the complexity of the problem resulting from plastic deformation of the structures. Macro-photographic data from a coated leading edge model show progressive degradation over several thermal cycles at aerothermal conditions representative of high Mach number flight.

Gladden, Herbert J.↗

A volatile fluid assisted thermo-pneumatic liquid metal energy harvester

A close-cycle self-driving thermal energy harvester using liquid metal as energy carrier fluid has been proposed. The driving force that pushes the liquid metal against flow resistance and gravity is provided by a resistively heated volatile fluid based on thermo-pneumatic principle. The tested harvester prototype demonstrated its capability to extract thermal energy between small temperature gradient, at a scale of 10 °C. During a 5-h operation, it further demonstrated robust liquid metal recirculating performance at a time-average volume flow rate of 14 ml/min with a 12.25 W heating load. The prototype also managed to self-adjust to variable working conditions which indicated the reliability of this method. Advantages of this method include simple-structural design, rigid-motion free operation, and low-temperature actuation. These advantages make it uniquely suited for solar energy and low-grade heat harvesting, high heat flux electronics cooling, as well as autonomous machines actuating.

42 ENGINEERING↗

Control of unsteady shock-induced turbulent boundary layer separation upstream of blunt fins

Fluctuating wall pressure measurements have been made on centerline upstream of blunt fins in a Mach 5 turbulent boundary layer. Standard time series analysis and conditional sampling algorithms have been used to examine the effects of leading edge sweepback, leading edge shape, and fin root modifications on the fluctuating pressures. Leading edge sweep considerably reduces the mean and rms pressure loading at the fin root, the extent of the region of unsteady separation shock motion, and the separation length. The frequency of pressure fluctuations in the intermittent region increases with leading edge sweepback, while the spectral content of pressure fluctuations in the separated region is virtually unchanged by leading edge sweep. A swept hemicylindrically blunted root fillet reduces the centerline upstream influence and intermittent region length by 50 percent, and reduces the mean and rms pressure loading at the fin root by about 75 percent and 95 percent respectively. Experiments using hemicylindrical, wedge shaped and flat leading edges show that while separated flow scales increase with increasing 'bluntness', intermittent region length and root loading decrease, and separation shock frequency increases.

Kleifges, K.↗

Toward an Improved Hypersonic Engine Seal

High temperature, dynamic seals are required in advanced engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures from 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA s Glenn Research Center (GRC) is developing advanced seals to overcome these shortfalls. Two seal designs and two types of seal preloading devices were evaluated in a series of compression tests at room temperature and 2000 F and flow tests at room temperature. Both seals lost resiliency with repeated load cycling at room temperature and 2000 F, but seals with braided cores were significantly more flexible than those with cores composed of uniaxial ceramic fibers. Flow rates for the seals with cores of uniaxial fibers were lower than those for the seals with braided cores. Canted coil springs and silicon nitride compression springs showed promise conceptually as potential seal preloading devices to help maintain seal resiliency.

Dunlap, Patrick H., Jr.↗

Analysis of Unsteady Tip and Endwall Heat Transfer in a Highly Loaded Transonic Turbine Stage

In a previous study, vane-rotor shock interactions and heat transfer on the rotor blade of a highly loaded transonic turbine stage were simulated. The geometry consists of a high pressure turbine vane and downstream rotor blade. This study focuses on the physics of flow and heat transfer in the rotor tip, casing and hub regions. The simulation was performed using the Unsteady Reynolds-Averaged Navier-Stokes (URANS) code MSU-TURBO. A low Reynolds number k-epsilon model was utilized to model turbulence. The rotor blade in question has a tip gap height of 2.1 percent of the blade height. The Reynolds number of the flow is approximately 3x10(exp 6) per meter. Unsteadiness was observed at the tip surface that results in intermittent "hot spots". It is demonstrated that unsteadiness in the tip gap is governed by inviscid effects due to high speed flow and is not strongly dependent on pressure ratio across the tip gap contrary to published observations that have primarily dealt with subsonic tip flows. The high relative Mach numbers in the tip gap lead to a choking of the leakage flow that translates to a relative attenuation of losses at higher loading. The efficacy of new tip geometry is discussed to minimize heat flux at the tip while maintaining choked conditions. In addition, an explanation is provided that shows the mechanism behind the rise in stagnation temperature on the casing to values above the absolute total temperature at the inlet. It is concluded that even in steady mode, work transfer to the near tip fluid occurs due to relative shearing by the casing. This is believed to be the first such explanation of the work transfer phenomenon in the open literature. The difference in pattern between steady and time-averaged heat flux at the hub is also explained.

Shyam, Vikram↗

Hydrodynamic Analysis and Optimization of Aquantis Marine Turbine: Cooperative Research and Development (Final Report)

The primary aim of this proposal is to improve the accurate prediction of hydrodynamic performance and dynamic load responses of the AQ10 floating axial-flow tidal turbine with a tri-cat mooring configuration. The validation of reduced-order modeling approaches with high-fidelity model will be implemented. Additionally, the frequency response domain, Response Amplitude Floating Wind (RAFT) toolbox plus an optimizer expanded for marine hydrokinetic turbines under the Submarine Hydrokinetic And Riverine Kilo-megawatt. Systems (SHARKS) program will be used for designing and exploring different key design parameters (platform dimension, mooring layout and its parameters) of next marine hydrokinetic (MHK) turbine generation.

16 TIDAL AND WAVE POWER↗

Design, fabrication and test of a trace contaminant control system

A trace contaminant control system was designed, fabricated, and evaluated to determine suitability of the system concept to future manned spacecraft. Two different models were considered. The load model initially required by the contract was based on the Space Station Prototype (SSP) general specifications SVSK HS4655, reflecting a change from a 9 man crew to a 6 man crew of the model developed in previous phases of this effort. Trade studies and a system preliminary design were accomplished based on this contaminant load, including computer analyses to define the optimum system configuration in terms of component arrangements, flow rates and component sizing. At the completion of the preliminary design effort a revised contaminant load model was developed for the SSP. Additional analyses were then conducted to define the impact of this new contaminant load model on the system configuration. A full scale foam-core mock-up with the appropriate SSP system interfaces was also fabricated.

Source record↗

Framework for Evaluating Grid Readiness for Integrating Electric Vehicles and Utility Scale Storage in India

Electric vehicles (EVs) and distributed solar are poised to grow substantially in India in the coming years following ambitious Government of India targets. The localized impact of these changes, both in terms of infrastructure investments and demand patterns, are not well understood, nor are tools for this type of analysis readily available. This paper describes the development of a framework that can analyze network readiness in terms of feeder impacts for distributed energy resources (DERs) including growing EV penetration, and the potential solutions introduced by utility-scale battery energy storage systems (BESSs). The building blocks of the feeder analysis require multiple data sets to be compiled into a usable network model. The work is driven by feeder head and distribution transformer (DT) loading data along with all the technical specifications and schematics of distribution feeders. These measured data sets are conditioned to remove any afflictions, and the cleaned load profiles are used to perform multi-year quasi-static time-series power flow analyses on detailed three-phase feeder models. EVs translated to grid-tied loads are represented with aggregated EV demand profile estimates based on possible charging scenarios in residential sector, and in workplace and/or public charging stations. Finally, BESSs are evaluated for their cost-effectiveness in the framework through an initial screening that includes the benefits of grid service applications to mitigate present and future overloading scenarios. The outcomes from this framework are expected to help utilities gauge the readiness of their distribution grid for integrating an increasing number of EVs as well as load growth during a projected multi-year time horizon, where BESSs can contribute in making the grid more reliable.

electric vehicles↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Solid state protective smart plug device

A wireless-controlled smart plug device and methods of use and operation, using a solid state switch to provide electrical power from an outlet to a load, and provide protection against overload, short circuit, ground, arc, or voltage surge faults. The switch includes a bidirectional semiconductor switch with two back-to-back connected transistors, such as silicon power MOSFETs, silicon insulated-gate bipolar transistors (IGBTs), silicon carbide (SiC) transistors, or gallium nitride (GaN) transistors, each configured to control the current flow from the electrical receptacle to the external electrical load.

Shen, Zheng↗

MRT 7365: Power flow physics and key physics phenomena

The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.

43 PARTICLE ACCELERATORS↗