Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Biotechnology Approaches to Life Detection

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. Several new and innovative biotechnology approaches are being explored. Firstly we have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to micron sized numbered spots on a small (2-3 cm) test plate where they become firmly attached after freeze drying. Using technology that has been developed for gene mining in DNA technology up to 10,000 tests per square inch can now be applied to a test plate. On Mars or the planet/moon of interest, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent and ultrasonication and then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. At the moment a small UV light source will illuminate the test plate, which is observed with a small CCD camera, although other detection systems will be applied. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. Furthermore with up to a thousand test plates available false positives and several variations of antibody can also be screened for. The entire instrument can be quite small and light, on the order of 10 cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. The stains in these spots may be directly activated, with no antibodies being necessary. The proposed system will look for three classes of biomarkers: those from extant life, such as DNA, those from extinct life such as hopanes, and those from organic compounds not necessarily associated with life such as PAHs, rocket exhaust contamination and other a/pre-biotic chemicals. Both monoclonal and polyclonal antibodies can be used. Monoclonal antibodies react with a very specific compound, but polyclonal antibodies may react to any of a whole family of compounds. Furthermore the technique of phage display to raise antibodies against classically non-antigenic molecules is also being considered. Additional information is contained in the original extended abstract.

Steele, Andrew↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Attosecond light science and its application for probing quantum materials

In this paper, we review the development and application of coherent short wavelength light sources implemented using the high harmonic generation (HHG) process. The physics underlying HHG brought quantum physics into the domain of attosecond time-scales for the first time. Here, the observation and manipulation of electron dynamics on such short time-scales—a capability not conceived—of just a few decades ago—is becoming both more-and-more sophisticated and useful as a route to achieve exquisite control over short wavelength light. New experimental techniques are enabling HHG light sources to provide new insights into fundamental quantum interactions in materials, making it possible for the first time to capture the fastest charge, spin, photon and phonon interactions and to achieve diffraction-limited imaging at short wavelengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of Recessed Downlight Technologies: Power and Illumination Assessment

Solid state lighting (SSL), specifically light-emitting diodes (LED), has been advancing at a rapid pace, and there are presently multiple products available that serve as direct replacements for traditional luminaires. In this demonstration, conventional recessed lights in a conference room were used to compare conventional incandescent A-lamps, incandescent reflector R-lamps, dimming compact fluorescent lamps (CFL), to an LED replacement product. The primary focus during the study was on light delivered to the task plane as provided by the power required by the lighting system. Vertical illuminance, dimming range, and color shift are also important indicators of lighting quality and are discussed in the report. The results clearly showed that LEDs, with dimming-capable drivers, are much more efficient than incandescent and CFLs. Further, LEDs provide much smoother and consistent dimming than dimmable CFLs. On the potential negative side, it is important that the dimming switch be identified as compatible with the LED driver. A wide variety of dimmer switches are capable of dimming LEDs down to 15% of full light output, while select others can be capable of dimming LEDs down to 5%. In addition, LEDs can be intensive light sources, which can result in uncomfortable glare in some applications and to some occupants. Higher ceiling (9-foot or greater) or non-specular reflectors can act to alleviate the potential for glare.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combining diagnostics, modeling, and control systems for automated alignment of the TES beamline

X-ray beamlines are essential components of all synchrotron light sources. Practical operations involve frequent variation in beamline component positions and orientation, particularly when photon beam parameters shift due to experimental needs, or due to variations in the incoming photon beam. The alignment process can be time consuming and takes away from valuable beam time for experimental data collection. We describe progress in the automation of certain alignment tasks on the tender-energy X-ray spectroscopy (TES) beamline at the National Synchrotron Light Source II (NSLS-II). The beamline is controlled using the BlueSky software in which high level experimental plans guide the beamline components during an experiment. Numerous software packages exist for beamline modeling, and they may be tied to the beamline control system using a package we are continuing to develop called Sirepo-Bluesky. The photon beam distribution may be measured with fluorescent screens, and a relation between beam and machine state can be found by varying the mirror and aperture settings over a multi-dimensional range. We describe the results of such parameter varying measurements and how we are combining Sirepo-Bluesky with machine learning methods and reduced models to automate mirror alignment on the TES beamline.

36 MATERIALS SCIENCE↗

Degradation in photovoltaic encapsulant transmittance: Results of the first PVQAT TG5 artificial weathering study

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation is frequently identified as a cause of decreased performance through the service life of photovoltaic modules. However, the present module safety and qualification standards apply short UV doses, only capable of examining design robustness and 'infant mortality' failures. Furthermore, essential information remains unknown that might be used to screen encapsulants through product lifetime. We conducted an interlaboratory study to provide the understanding that will be used toward developing a higher-fidelity, more-rigorous UV weathering test. Five representative known formulations of poly (ethylene-co-vinyl acetate) were studied, in addition to one thermoplastic polyurethane material. Replicate laminated silica/polymer/silica specimens were examined at seven institutions using a variety of indoor chambers (including xenon, UVA-340, and metal-halide light sources). Specimens were artificially weathered for 180 cumulative days at steady-state accelerated test conditions, predesignated relative to the default irradiance of 1.0 W m-2 nm-1 at 340 nm, chamber temperature of 60 degrees C, and chamber relative humidity of 30%. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength - each determined from the measured hemispherical transmittance - are examined to provide understanding and guidance for the UV light source (type lamp and filters), temperature, and humidity used in accelerated UV aging tests. The relative efficacy of xenon-arc and UVA-340 fluorescent sources and the typical range of activation energy for degradation is quantified from the experiments.

14 SOLAR ENERGY↗

Time-resolved Hyperspectral Fluorescence Spectroscopy using Frequency Modulated Excitation

An intensity-modulated excitation light source is used together with a micro channel plate intensified CCD (ICCD) detector gated at a slightly different frequency to generate a beat frequency from a fluorescent sample. The addition of a spectrograph produces a hyperspectral time-resolved data product where the resulting beat frequency is detected with a low frame rate camera. Measuring the beat frequency of the spectrum as a function of time allows separation of the excited fluorescence from ambient constant light sources. The excitation and detector repetition rates are varied over a range of discrete frequencies, and the phase shift of the beat wave maps out the emission decay rate(s).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stability of the fcc phase in shocked nickel up to 332 GPa

Despite making up 5-20 wt.% of Earth’s predominantly iron core, the melting properties of elemental nickel at core conditions remain poorly understood, due largely to a dearth of experimental data. We present here an in situ X-ray diffraction study performed on laser shock-compressed samples of bulk nickel, reaching pressures up to ~ 500 GPa. Hugoniot states of nickel were targeted using a flat-top laser drive, with in situ X-ray diffraction data collected using the Linac Coherent Light Source. Rietveld methods were used to determine the densities of the shocked states from the measured diffraction data, while peak pressures were determined using a combination of measured particle velocities, shock transit times, hydrodynamic simulations, and laser intensity calibrations. We observed solid compressed face-centered cubic (fcc) Ni up to at least 332 ± 30 GPa along the Hugoniot—significantly higher than expected from the majority of melt lines that have been proposed for nickel. We also bracket the partial melting onset to between 377 ± 38 GPa and 486 ± 35 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Light-Emitting Diodes (LED) for Primary Animal Habitat Lighting in Highly Controlled Environments

Significant alterations in Biological Clock responses have been reported following sidereal time changes (e.g., Jet-lag), and exposure to microgravity (e.g., daytime sleepiness). Additionally, light reduces circulating melatonin (spectral specificity greatest between 450-500 nm). It was hypothesized that LEDs can replace the current light sources used in zero gravity and terrestrial research laboratories because of their small size, low mass, low energy consumption and long functional life. This report evaluates the capacity of LEDs to entrain the circadian system of rats as judged by measurement of overt behavioral circadian rhythms (activity, feeding, drinking). These data were collected in highly controlled environments similar to the shuttle Animal Enclosure Modules. Two groups were compared: control - animals exposed to standard cool-white fluorescent lights, and test - animals exposed to LEDs with a spectral power distribution matching the fluorescent lights. Gross locomotor activity, feeding and drinking frequencies were continuously monitored and stored at 10 minute intervals. Animals were exposed to the following photoperiods: 28 days of 12L:12D, 19 days of 24L:0D and 16 days of 12L:12D. Light intensities tested varied between 0.1 to 100 lux. Rats received food and water ad libitum, and temperature and humidity were controlled throughout the study. The general health status of all rats was acceptable for each day of this study. No incidents of aggressive behavior were observed. Growth, locomotor activity, food and water consumption were comparable for all groups of animals, i.e, the circadian characteristics of the animals under these conditions were comparable. These results indicate that LED arrays are as effective in maintaining circadian rhythm stability as the commonly used cool-white fluorescent light sources. LEDs with their flexible spectrum, low energy requirements and minimal heat production have advantages for some chronopharmacology studies and for microgravity animal habitats.

Winget, C. M.↗

Pushing resolution in frequency and time: general discussion

One of the most important aspects of spectroscopy in general is resolution: the higher it is, the more information can be attained. At one end, spectral resolution provides geometric and electronic structural information and insights into weak interactions such as hydrogen bonds. At the other end, temporal resolution provides insight into geometric and electronic structural dynamics. The aim of this session is to provide a forum to discuss the state of the art in terms of resolution in general and how recent advances in light sources and ion mass spectroscopy can be used to study unexplored phenomena and interactions. Theoretical developments also have a key role in this area, particularly in relation to time-resolved measurements, since theoretical predictions are of key importance for providing molecular-insight into the observed experimental dynamics. The key discussion points will revolve around how experiment and theory can best combine to achieve the deepest insight, both in terms of structure and dynamics; and how new light sources may open new horizons.

Simons, Jack↗

Numerical and experimental study of atomic transport and Balmer line intensity in Linac4 negative ion source

Time structure of Balmer H{sub α} line intensity in Linac4 RF plasma has been analyzed by the combined simulation model of atomic transport and Collisional-Radiative models. As a preliminary result, time variation of the line intensity in the ignition phase of RF plasma is calculated and compared with the experimental results by photometry. For the comparison, spatial distribution of the local H{sub α} photon emission rate at each time is calculated from the numerical model. The contribution of the local photon emission rates to the observed line intensity via optical viewing port is also investigated by application of the mock-up of the optical viewing port and the known light source. It has been clarified from the analyses that the higher and the lower peaks of the H{sub α} line intensity observed during 1 RF cycle is mainly due to the different spatial distributions in the electron energy distribution function and the resultant local photon emission rate. These results support previous suggestion that the existence of the capacitive electric field in axial direction leads to the higher/lower peaks of the line intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bending Magnet Synchrotron Radiation Imaging with Large Orbital Collection Angles

Synchrotron radiation (SR) from bending magnets, wigglers, and undulators is now extensively produced for users at storage ring based light sources, with unique properties in terms of average brightness and stability. Here, we present a profound study of bending magnet SR intensity distribution in the image plane of a focusing optical system. Measurements of this intensity distribution at the MAX-IV low emittance storage ring are compared to theoretical predictions, and found to be in excellent agreement. This work shows upon the possibility of performing high resolution emittance diagnostics with visible or near-visible SR on upcoming low-emittance storage ring based light sources. As a byproduct of our study, we derive a closed analytical expression for the intensity distribution from a zero-emittance beam, in the limiting case of wide orbital collection angles. This expression finally allows us to demonstrate the meeting between classical electrodynamics applied to SR emission and focusing, and the Landau and Lifshitz prediction of radiation intensity distribution nearby a caustic.

36 MATERIALS SCIENCE↗

Sirepo : an open-source cloud-based software interface for X-ray source and optics simulations

Sirepo , a browser-based GUI for X-ray source and optics simulations, is presented. Such calculations can be performed using SRW ( Synchrotron Radiation Workshop ), which is a physical optics computer code, allowing simulation of entire experimental beamlines using the concept of a `virtual beamline' with accurate treatment of synchrotron radiation generation and propagation through the X-ray optical system. SRW is interfaced with Sirepo by means of a Python application programming interface. Sirepo supports most of the optical elements currently used at beamlines, including recent developments in SRW . In particular, support is provided for the simulation of state-of-the-art X-ray beamlines, exploiting the high coherence and brightness of modern light source facilities. New scientific visualization and reporting capabilities have been recently implemented within Sirepo , as well as automatic determination of electron beam and undulator parameters. Publicly available community databases can be dynamically queried for error-free access to material characteristics. These computational tools can be used for the development and commissioning of new X-ray beamlines and for testing feasibility and optimization of experiments. The same interface can guide simulation on a local computer, a remote server or a high-performance cluster. Sirepo is available online and also within the NSLS-II firewall, with a growing number of users at other light source facilities. Our open source code is available on GitHub.

99 GENERAL AND MISCELLANEOUS↗

Synthesis and Observation of Emergent Phenomena in Epitaxial Heusler Compound Heterostructures

The proposal was on the synthesis and observation of emergent phenomena in epitaxial Heusler compound heterostructures. The large range of properties and number of Heusler compounds opens up a wide number of potential compounds that will exhibit emergent phenomena. The similarity, large range of relatively inexpensive, large area, high crystal quality, III-V bulk substrates, lattice parameters and the ability to tune the lattice parameters through ternary or quaternary III-V compound semiconductor epitaxial growth, makes III-V semiconductors an ideal choice for substrates for epitaxial growth of Heusler compounds. A number of half Heusler compounds have been predicted to exhibit band inversion, making them topological and are therefore expected to exhibit spin-momentum locked topological surface states with linear dispersion. Others are predicted to be semimetals with Weyl points and others semiconducting and magnetic. During the course of this grant, emphasis has been on investigating Heusler compounds with emergent phenomena and demonstrating the ability to tune their properties through alloying and strain. We have grown toplogical semimetal (PtLuSb, PtMnBi), Weyl (Co 2 MnAl, Co 2 TiGe), half metal (PtMnSb, Co 2 MnSi, Co 2 MnAl x Si 1-x , Co2FeAl), and semiconducting (CoTiSb, NiTiSn) and tuned their properties through alloying and epitaxial strain. We also investigated the closely related materials of rare-earth monopnictide, some of which have also been predicted to be topological. During the attempts to grow the PtMnBi, it was discovered that Bi, another predicted topological material when ultrathin, could be grown epitaxially on InSb, results for which are also reported here. The main focus for this effort has been on using variable photon energy and spin-dependent angle resolved photoemission (ARPES) to determine bulk band structure and surface states of pristine epitaxial films grown on III-V semiconductor and MgO substrates and correlate results with theory and transport measurements. Theory has been critical to interpretation of experimental results and has been essential in guiding experiments. The research benefited from several strong collaborations between the PIs and the beamline scientists at the Advanced Light Source at Lawrence Berkeley Laboratory, the Stanford Linear Accelerator Center (SLAC) at Stanford and at the Max Lab at Lund University in Sweden. The strong experiment - theory collaboration between the PI’s groups, the Palmstrøm group at UCSB and the Janotti group at the University of Delaware, has been critical for interpreting the experimental ARPES and magnetotransport measurements results and making predictions to guide experiments. Weekly interactive Zoom meetings made this work well. A collaboration between the Palmstrøm group and Dr. Alexei Fedorov at the Advanced Light Source (ALS) resulted in significant modifications to his end chamber to accommodate the vacuum suitcase that was designed and constructed in the Palmstrøm group at UCSB. In collaboration with beamline scientists, Drs. Makoto Hashimoto and Donghui Lu at SLAC, Palmstrøm made modifications to the vacuum suitcase and developed special sample holders that allowed samples to be grown in the Palmstrøm MBE systems at UCSB and transported in the UHV vacuum suitcase to SLAC for ARPES measurements. The development of the vacuum suitcase was essential for this grant as it has allowed variable photon energies to be used to identify surface versus bulk states on samples that could not be capped and decapped using As- or Sb-capping layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Skyshine from an Accelerator Facility: Dependence on Distance and Angle

Neutron skyshine from Linac Coherent Light Source II 4 GeV electron beam operation at SLAC National Accelerator Laboratory can contribute to prompt radiation exposure to the public at distances far beyond the accelerator tunnel housing. One of the shielding design requirements at SLAC is that the annual dose to a member of the public is no more than 0.05 mSv y -1 . Our work uses Monte Carlo code FLUKA to simulate the generation of neutrons from 4 GeVelectron beam losses on a thick copper target inside a generalized geometry of the Linac Coherent Light Source II Beam Transport Hall accelerator tunnel section. The effective dose from neutron skyshine was characterized as a function of both distance from the tunnel wall (up to 1 km away) and angle relative to the beam direction (between 0° and 180°). Furthermore, this new methodology for evaluating neutron skyshine dose is applicable to high-energy GeV-range electron accelerator facilities both at SLAC and elsewhere.

43 PARTICLE ACCELERATORS↗

Photothermal heterodyne imaging of micron-sized objects

Micron-sized dye-doped polymer beads were imaged using transmitted/reflected light microscopy and photothermal heterodyne imaging (PHI) measurements. The transmitted/reflected light images show distinct ring patterns that are attributed to diffraction effects and/or internal reflections within the beads. In the PHI experiments pump laser induced heating changes the refractive index and size of the bead, which causes changes in the diffraction pattern and internal reflections. This creates an analogous ring pattern in the PHI images. The ring pattern disappears in both the reflected light and PHI experiments when an incoherent light source is used as a probe. When the beads are imaged in an organic medium heat transfer changes the refractive index of the environment, and gives rise to a ring pattern external to the beads in the PHI images. This causes the beads to appear larger than their physical dimensions in PHI experiments. This external signal does not appear when the beads are imaged in air because the refractive index changes in air are very small.

Bhandari, Janak (ORCID:0000000188423259)↗

Active Wide-Field Sky Simulator Design for the JPL Astrometry Testbed

Exoplanet detection through astrometry will provide mass measurements that are key to our understanding of exoplanet demographics. Astrometric surveys are also critical pre-cursor observations for identifying targets for future direct imaging missions, such as the HabEx and LUVOIR mission concepts. However, Earth-mass planets orbiting Sun-like stars within 10 pc only cause a 0.3 uas astrometric signal, which is about two orders of magnitude smaller than the current state-of-the-art. In order to advance the technologies needed for future astrometry instruments, a testbed capable of simulating and measuring equivalent Earth-like exoplanet astrometric signals was created. The testbed has a stable light source that simulates a field of stars and can introduce a sub-uas astrometric signal onto a central artificial target star. This is done by illuminating an array of pinholes lithographically printed onto a glass substrate and translating, with picometer resolution, a target-star pinhole located on a centrally cut flexure feature. To detect this motion, a diffractive pupil is used to calibrate the limiting optical distortions of an Offner relay. Presented in this paper are the requirements, design, and implementation of the wide-field astrometry testbed’s light source.

Bendek, Eduardo↗