Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

High-Spatial and High-Mass Resolution Imaging of Surface Metabolites of Arabidopsis thaliana by Laser Desorption-Ionization Mass Spectrometry Using Colloidal Silver

High-spatial resolution and high-mass resolution techniques are developed and adopted for the mass spectrometric imaging of epicuticular lipids on the surface of Arabidopsis thaliana. Single cell level spatial resolution of {approx}12 {micro}m was achieved by reducing the laser beam size by using an optical fiber with 25 {micro}m core diameter in a vacuum matrix-assisted laser desorption ionization-linear ion trap (vMALDI-LTQ) mass spectrometer and improved matrix application using an oscillating capillary nebulizer. Fine chemical images of a whole flower were visualized in this high spatial resolution showing substructure of an anther and single pollen grains at the stigma and anthers. The LTQ-Orbitrap with a MALDI ion source was adopted to achieve MS imaging in high mass resolution. Specifically, isobaric silver ion adducts of C29 alkane (m/z 515.3741) and C28 aldehyde (m/z 515.3377), indistinguishable in low-resolution LTQ, can now be clearly distinguished and their chemical images could be separately constructed. In the application to roots, the high spatial resolution allowed molecular MS imaging of secondary roots and the high mass resolution allowed direct identification of lipid metabolites on root surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Surface-Enhanced Raman Imaging of Latent Fingerprints

Exposure to light or heat, or simply a dearth of fingerprint material, renders some latent fingerprints undetectable using conventional methods. We begin to address such elusive fingerprints using detection targeting photo- and thermally stable fingerprint constituents: surface-enhanced Raman spectroscopy (SERS). SERS can give descriptive vibrational spectra of amino acids, among other robust fingerprint constituents, and good sensitivity can be attained by improving metal-dielectric nanoparticle substrates. With SERS chemical imaging, vibrational bands intensities recreate a visual of fingerprint topography. The impact of nanoparticle synthesis route, dispersal methodology-deposition solvent, and laser wavelength are discussed, as are data from enhanced vibrational spectra of fingerprint components. SERS and Raman chemical images of fingerprints and realistic contaminants are shown. To our knowledge, this represents the first SERS imaging of fingerprints. In conclusion, this work progresses toward the ultimate goal of vibrationally detecting latent prints that would otherwise remain undetected using traditional development methods.

36 MATERIALS SCIENCE↗

Full color hybrid display for aircraft simulators

A full spectrum color monitor, connected to the camera and lens system of a television camera supported by a gantry frame over a terrain model simulating an aircraft landing zone, projects the monitor image onto a lens or screen visually accessible to a trainee in the simulator. A digital computer produces a pattern corresponding to the lights associated with the landing strip onto a monochromatic display, and an optical system projects the calligraphic image onto the same lens so that it is superposed on the video representation of the landing field. The optical system includes a four-color wheel which is rotated between the calligraphic display and the lens, and an apparatus for synchronizing the generation of a calligraphic pattern with the color segments on the color wheel. A servo feedback system responsive to the servo motors on the gantry frame produces an input to the computer so that the calligraphically generated signal corresponds in shape, size and location to the video signal.

Chase, W. D.↗

A Catalog of Coronal "EIT Wave" Transients

SOHO Extreme Ultraviolet Imaging Telescope (EIT) data have been visually searched for coronal "EIT wave" transients over the period beginning 24 March 1997 extending through 24 June 1998. The dates covered start at the beginning of regular high-cadence (more than 1 image every 20 minutes) observations, ending at the 4-month interruption of SOHO observations in mid-1998. 176 events are included in this catalog. The observations range from "candidate" events, which were either weak or had insufficient data coverage, to events which were well-defined and were clearly distinguishable in the data. Included in the catalog are times of the EIT images in which the events are observed, diagrams indicating the observed locations of the wavefronts and associated active regions, and the speeds of the wavefronts. The measured speeds of the wavefronts varied from less than 50 to over 700 km/sec with "typical" speeds of 200-400 Msec.

Thompson, B. J.↗

Integration of visual and motion cues for simulator requirements and ride quality investigation

Preliminary tests and evaluation are presented of pilot performance during landing (flight paths) using computer generated images (video tapes). Psychophysiological factors affecting pilot visual perception were measured. A turning flight maneuver (pitch and roll) was specifically studied using a training device, and the scaling laws involved were determined. Also presented are medical studies (abstracts) on human response to gravity variations without visual cues, acceleration stimuli effects on the semicircular canals, and neurons affecting eye movements, and vestibular tests.

Young, L. R.↗

2D microwave imaging reflectometer electronics

A 2D microwave imaging reflectometer system has been developed to visualize electron density fluctuations on the DIII-D tokamak. Simultaneously illuminated at four probe frequencies, large aperture optics image reflections from four density-dependent cutoff surfaces in the plasma over an extended region of the DIII-D plasma. Localized density fluctuations in the vicinity of the plasma cutoff surfaces modulate the plasma reflections, yielding a 2D image of electron density fluctuations. Details are presented of the receiver down conversion electronics that generate the in-phase (I) and quadrature (Q) reflectometer signals from which 2D density fluctuation data are obtained. Also presented are details on the control system and backplane used to manage the electronics as well as an introduction to the computer based control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-28: Development of a New Imaging Filter to Remove the Shadows From the Carbon Fiber Grid Table Top

Purpose: For the image guided radiation therapy (IGRT), the shadows caused by the construction of the treatment couch top adversely affect the visual evaluation. Therefore, we developed the new imaging filter in order to remove the shadows. The performance of the new filter was evaluated using the clinical images. Methods: The new filter was composed of the band-pass filter (BPF) weighted by the k factor and the low-pass filter (LPF). In the frequency region, the stop bandwidth were 8.3×10{sup 3} mm{sup −1} on u direction and 11.1×10{sup 3} mm{sup −1} on v direction for the BPF, and the pass bandwidth were 8.3×10{sup 3} mm{sup −1} on u direction and 11.1×10{sup 3} mm{sup −1} on v direction for the LPF. After adding the filter, the shadows from the carbon fiber grid table top (CFGTT, Varian) on the kV-image was removed. To check the filter effect, we compared the clinical images, which are thorax and thoracoabdominal region, with to without the filter. The subjective evaluation tests was performed by adapting a three-point scale (agree, neither agree nor disagree, disagree) about the 15 persons in the department of radiation oncology. Results: We succeeded in removing all shadows of CFGTT using the new filter. This filter is very useful shown by the results of the subjective evaluation having the 23/30 persons agreed to the filtered clinical images. Conclusion: We concluded that the proposed method was useful tool for the IGRT and the new filter leads to improvement of the accuracy of radiation therapy.

60 APPLIED LIFE SCIENCES↗

Optical Diagnostic Imaging of Multi-Rocket Plume-Induced Base Flow Environments

Non-intrusive optical diagnostic imaging was used for the first time to visualize multi-rocket plume-induced reacting base flows to simulate launch vehicle ascent from sea-level to 250,000 ft. In particular, planar laser induced florescence (PLIF) and infrared (IR) imaging were implemented for the first time to visualize and quantify base flow and rocket plume environments from sub-scale, short-duration propulsion models within a shock tunnel facility. This report discusses the successful imaging diagnostic methods for capturing base flow features and dynamics as a function of altitude. Important base flow and plume features were captured with PLIF and IR diagnostics to develop a conceptual base flow physics model. This imaging data specifically provides insight into the Space Launch System vehicle core-stage and Exploration Upper Stage base environments and further validates short-duration ground test techniques and computational modeling.

Mehta, Manish↗

Foundation Models for Zero-Shot Segmentation of Scientific Images without AI-Ready Data

Zero-shot and prompt-based models have excelled at visual reasoning tasks by leveraging large-scale natural image corpora, but they often fail on sparse and domain-specific scientific image data. We introduce Zenesis, a no-code interactive computer vision platform designed to reduce data readiness bottlenecks in scientific imaging workflows. Zenesis integrates lightweight multimodal adaptation for zero-shot inference on raw scientific data, human-in-the-loop refinement, and heuristic-based temporal enhancement. We validate our approach on Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) datasets of catalyst-loaded membranes. Zenesis outperforms baselines, achieving an average accuracy of 0.947, Intersection over Union (IoU) of 0.858, and Dice score of 0.923 on amorphous catalyst samples; and 0.987 accuracy, 0.857 IoU, and 0.923 Dice on crystalline samples. These results represent a significant performance gain over conventional methods such as Otsu thresholding and standalone models like the Segment Anything Model (SAM). Zenesis enables effective image segmentation in domains where annotated datasets are limited, offering a scalable solution for scientific discovery.

Mukherjee, Shubhabrata↗

Manual versus digital Landsat analysis for delineating river flooding

It has been found that flood boundary information derived from Landsat images, acquired at different flood stages, could be used to develop an empirical model for estimating the extent of flooding on the basis of in situ measurements of river discharge. An investigation was undertaken to determine whether improved results might have been obtained through digital image analysis or by including other Landsat spectral bands. The study area encompasses a highly flood-prone reach of the Black River in Lewis County, NY. It was found that visual analysis of aerial photographs and a Landsat band 7 image gave similar results. Visual and digital analysis of Landsat band 7 data gave similar results, and digital analysis of Landsat band 7 data gave results which were at least as good as digital analysis of combinations of spectral bands.

Philipson, W. R.↗

Concept of an upright wearable positron emission tomography imager in humans

Abstract Background Positron Emission Tomography ( PET ) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_ PET ) and conducted tests in phantoms and four human volunteers. Methods Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET / CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET / CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROI s. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

60 APPLIED LIFE SCIENCES↗

A CATALOG OF CORONAL 'EIT WAVE' TRANSIENTS

Solar and Heliospheric Observatory (SOHO) Extreme ultraviolet Imaging Telescope (EIT) data have been visually searched for coronal 'EIT wave' transients over the period beginning from 1997 March 24 and extending through 1998 June 24. The dates covered start at the beginning of regular high-cadence (more than 1 image every 20 minutes) observations, ending at the four-month interruption of SOHO observations in mid-1998. One hundred and seventy six events are included in this catalog. The observations range from 'candidate' events, which were either weak or had insufficient data coverage, to events which were well defined and were clearly distinguishable in the data. Included in the catalog are times of the EIT images in which the events are observed, diagrams indicating the observed locations of the wave fronts and associated active regions, and the speeds of the wave fronts. The measured speeds of the wave fronts varied from less than 50 to over 700 km s{sup -1} with 'typical' speeds of 200-400 km s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

An atmospheric outburst on Neptune from 1986 through 1989

Visual photometry and methane-band imaging indicate that Neptune underwent a period of atmospheric activity in the 1986-1989 period with an enhancement of 8900 A CH4-band brightness and an increased standard deviation of the mean yearly magnitudes at visual and near-IR wavelengths. These observations are presently interpreted as due to a localized upwelling source that could be similar to the 'great white spots' that have been periodically observed on Saturn.

Hammel, H. B.↗

A Catalog of Coronal "EIT Wave" Transients

Solar and Heliospheric Observatory (SOHO) Extreme ultraviolet Imaging Telescope (EIT) data have been visually searched for coronal "EIT wave" transients over the period beginning from 1997 March 24 and extending through 1998 June 24. The dates covered start at the beginning of regular high-cadence (more than one image every 20 minutes) observations, ending at the four-month interruption of SOHO observations in mid-1998. One hundred and seventy six events are included in this catalog. The observations range from "candidate" events, which were either weak or had insufficient data coverage, to events which were well defined and were clearly distinguishable in the data. Included in the catalog are times of the EIT images in which the events are observed, diagrams indicating the observed locations of the wave fronts and associated active regions, and the speeds of the wave fronts. The measured speeds of the wave fronts varied from less than 50 to over 700 km s(exp -1) with "typical" speeds of 200-400 km s(exp -1).

Thompson, B. J.↗

Atomic-scale imaging of frequency-dependent phonon anisotropy

Directly visualizing vibrational anisotropy in individual phonon modes is essential for understanding a wide range of intriguing optical, thermal and elastic phenomena in materials. Although conventional optical and diffraction techniques have been used to estimate vibrational anisotropies, they fall short in achieving the spatial and energy resolution necessary to provide detailed information. Here, we introduce a new form of momentum-selective electron energy-loss spectroscopy, which enables the element-resolved imaging of frequency- and symmetry-dependent vibrational anisotropies with atomic resolution. Vibrational anisotropies manifest in different norms of orthogonal atomic displacements, known as thermal ellipsoids. Using the centrosymmetric strontium titanate as a model system, we observed two distinct types of oxygen vibrations with contrasting anisotropies: oblate thermal ellipsoids below 60 meV and prolate ones above 60 meV. In non-centrosymmetric barium titanate, our approach can detect subtle distortions of the oxygen octahedra by observing the unexpected modulation of q-selective signals between apical and equatorial oxygen sites near 55 meV, which originates from reduced crystal symmetry and may also be linked to ferroelectric polarization. These observations are quantitatively supported by theoretical modelling, which demonstrates the reliability of our approach. The measured frequency-dependent vibrational anisotropies shed new light on the dielectric and thermal behaviours governed by acoustic and optical phonons. Furthermore, the ability to visualize phonon eigenvectors at specific crystallographic sites with unprecedented spatial and energy resolution opens new avenues for exploring dielectric, optical, thermal and superconducting properties.

Ferroelectrics and multiferroics↗

SU-E-J-229: Magnetic Resonance Imaging of Small Fiducial Markers for Proton Beam Therapy

Purpose: For proton beam therapy, small fiducial markers are preferred for patient alignment due to less interference with the proton beam. Visualizing small fiducial markers can be challenging in MRI. This study intends to investigate MRI imaging protocols for better visualization of small fiducial markers. Methods: Two carbon and two coil-shaped gold markers were placed into a gel phantom. Both carbon markers had a diameter of 1mm and a length of 3mm. Both gold markers had a length of 5mm. One gold marker had a diameter of 0.5mm and the other had a diameter of 0.75mm. T1 VIBE, T2 SPACE, TrueFISP and susceptibility weighted (SW) images were acquired. To improve marker contrast, high spatial resolution was used to reduce partial volume effect. Slice thickness was 1.5mm for all four sequences and in-plane resolution was 0.6mm for TrueFISP, 0.7mm for T1 VIBE, and 0.8mm for T2 SPACE and SW. For comparison purpose, a 3D T1 VIBE image set at 3mm slice thickness and 1.2mm in-plane resolution was also acquired. Results: All markers were visible in all high-resolution image sets. In each image set, marker-induced signal void was the smallest (in diameter) for carbon markers, followed by the 0.5mm gold marker and the largest for the 0.75mm gold marker. The SW images had the largest marker-induced signal void. However, those might be confused by susceptibility-gradient-induced signal voids. T1 VIBE had good visualization of markers with nicely defined edges. T2 SPACE had reasonable visualization of markers but edges were slightly blurred. TrueFISP had good visualization of markers only if they were not masked by banding artifacts. As a comparison, all markers were hardly visible in the standard resolution T1 VIBE images. Conclusion: 3D high-resolution T1 VIBE and SW have great potential in providing good visualization of small fiducial markers for proton beam therapy.

60 APPLIED LIFE SCIENCES↗

A Structural Basis for 129 Xe Hyper-CEST Signal in TEM-1 β-Lactamase

Genetically encoded (GE) contrast agents detectable by magnetic resonance imaging (MRI) enable non-invasive visualization of gene expression and cell proliferation at virtually unlimited penetration depths. Using hyperpolarized 129 Xe in combination with chemical exchange saturation transfer, an MR contrast approach known as hyper-CEST, enables ultrasensitive protein detection and biomolecular imaging. GE MRI contrast agents developed to date include nanoscale proteinaceous gas vesicles as well as the monomeric bacterial proteins TEM-1 β-lactamase (bla) and maltose binding protein (MBP). To improve understanding of hyper-CEST NMR with proteins, we performed structural and computational studies to further characterize the Xe-bla interaction. X-ray crystallography validated the location of a high-occupancy Xe binding site predicted by MD simulations, and mutagenesis experiments confirmed this Xe site as the origin of the observed CEST contrast. Structural studies and MD simulations with representative bla mutants offered additional insight regarding the relationship between local protein structure and CEST contrast.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗