At least 1,279 records · Page 71

Distribution Grid Incentive Design with Unknown Agent Behavior

Motivation: During extreme events, traditional grid regulation methods (e.g., energy prices, net power injection limits) may be insufficient. While system operators typically lack control over end-user grid interactions, (e.g., energy demand), incentives can influence behavior - for example, a user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. Problem: Optimize for the best incentive subject to system stability constraints. However, user behavior is unknown to the SO - i.e., for a given incentive, the amount of curtailed load or control variables exposed is unknown.

feedback based control↗

Techno-Economic Assessments of Second-Life Batteries for Electric Vehicle Charging Stations

When electric vehicle (EV) batteries degrade below a certain capacity, they may no longer be suitable for automotive use but can be repurposed as second-life batteries (SLBs) for other applications, such as EV charging stations. When integrated with photovoltaic (PV) systems, SLB can store surplus solar energy, reducing reliance on the grid and lowering operational costs. This paper presents a novel techno-economic assessment framework for deploying SLBs in combination with PV in grid-connected EV charging stations. The proposed framework integrates the value proposition, charging station operation, optimal dispatch strategies, battery degradation modeling, input data requirements, and detailed procedures for generating key economic performance metrics. Insightful analyses are performed to assess the performance of SLBs in comparison to new batteries across various cost scenarios. The results indicate that SLBs become financially attractive when their cost is 40% or lower than new batteries.

energy storage↗

Some Issues in Uncertainty Quantification and Parameter Tuning: A Case Study of Convective Parameterization Scheme in the WRF Regional Climate Model

The current tuning process of parameters in global climate models is often performed subjectively, or treated as an optimization procedure to minimize the difference between model fields and observations. The later approach may be generating a set of tunable parameters that approximate the observed climate but via an unrealistic balance of physical processes and/or compensating errors over different regions in the globe. In this study, we run the Weather Research and Forecasting (WRF) regional model constrained by the reanalysis data over the Southern Great Plains (SGP) where abundant observational data from various resources are available for calibration of the input parameters and validation of the model results. Our goal is to quantify the uncertainty ranges and identify the optimal values of five key input parameters in a new Kain-Frisch (KF) convective parameterization scheme incorporated in the WRF model. A stochastic sampling algorithm, Multiple Very Fast Simulated Annealing (MVFSA), is employed to efficiently sample the input parameters in KF scheme based on the skill score so that the algorithm progressively moves toward regions of the parameter space that minimize model errors. The results based on the WRF simulations with 25-km grid spacing over the SGP show that the model bias for precipitation can be significantly reduced by using five optimal parameters identified by the MVFSA algorithm. The model performance is very sensitive to downdraft and entrainment related parameters and consumption time of Convective Available Potential Energy (CAPE). Simulated convective precipitation decreases as the ratio of downdraft to updraft flux increases. Larger CAPE consumption time results in less convective but more stratiform precipitation. The simulation using optimal parameters obtained by only constraining precipitation generates positive impact on the other output variables, such as temperature and wind. By using the optimal parameters obtained at 25 km simulation, both the magnitude and spatial pattern of simulated precipitation are improved at 12-km spatial resolution. The optimal parameters identified from the SGP region have also improved the simulation of precipitation when moving model domain to another region with a different climate regime (i.e. North America monsoon region). These results suggest the improvement of precipitation simulation by using the optimal parameters remains when the model domain or spatial resolution is changed.

54 ENVIRONMENTAL SCIENCES↗

A Full Multigrid Method for the Self-Adjoint Angular Flux Equation Based on Cellwise Block Jacobi Iteration

Previous work by Densmore et al. has demonstrated that multigrid methods for the self-adjoint angular flux (SAAF) equation with cellwise block Jacobi smoothing can be extremely effective at solving for the angular flux in one dimension. The extension of that work to two dimensions demonstrated that while the smoother works well, the use of a direct coarse-grid approximation can severely limit the rate of convergence for optically thin cells. In that paper, this convergence limit was evaded through the use of a partially Galerkin coarse-grid approximation. However, relying on a Galerkin coarse-grid approximation is not ideal as constructing the coarse-grid discretization in this approach is complicated. The motivation for this summary is to find a method that can work without the need for a Galerkin coarse-grid approximation. The Full Multigrid (FMG) method is well known as a method that can theoretically solve a problem to its discretization accuracy with optimal linear computational complexity, that is in just O(N) operations for N unknowns. Indeed, we develop an FMG method for the 2-D SAAF equation that yields discretization accuracy and does not require the use of a Galerkin coarse-grid approximation. Until recently, aside from proofs about the order of the error for FMG, little work had been done in quantifying when and how FMG can obtain discretization accuracy. However, recent work by Rodrigo et al. has introduced a Fourier analysis technique called worst-case right-hand side analysis used to calculate the FMG accuracy measure. The FMG accuracy measure is the upper bound on the constant of proportionality between the error of the FMG solution and the discretization error. In this summary, we develop and implement an FMG method for the 2-D Cartesian SAAF equations. We then perform worst-case right-hand side analysis and give numerical examples that demonstrate under what circumstances the method can solve the 2-D SAAF equations to discretization accuracy, for optically thin cells, without the need for a Galerkin coarse-grid approximation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DP-Based Optimization of BESS to Substitute RICE Reserves for Improved Economic Benefits

In regions with a significant proportion of renewable energy sources, reciprocating internal combustion engines (RICE or IC) are frequently employed as grid reserve solutions. This study suggests a scheduling technique for battery energy storage systems (BESS) that utilizes dynamic programming (DP) to replace IC units, adding versatility to the total reserve capacity and resulting in higher BESS earnings compared to traditional scheduling approaches. The capacity sweeping approach to optimize BESS’s revenue sometimes leads to operation which is counter intuitive to conventional battery sizing approaches.

25 ENERGY STORAGE↗

Applying Particle Swarm Optimization and Extended Kalman Filtering to Model Kaplan Generation Dynamics for Hydropower Systems

Variable renewable generation is increasing the need for hydropower plants to provide fast and flexible grid support, which places new demands on plant-level dynamic models used for monitoring, control, and operational decision-making. This need is especially important for hydroelectric systems, where turbine and generator dynamics are strongly coupled, nonlinear, and time-varying, making accurate real-time representation difficult. To address this problem, this paper develops a digital twin (DT) framework for a synchronous generator–Kaplan turbine system using an explicit separation of slow turbine dynamics and fast generator dynamics. The turbine subsystem is represented by a six-coefficient model, whose parameters are identified offline using particle swarm optimization, while the generator subsystem is updated online through an extended Kalman filter for real-time state and parameter estimation. These models are integrated within a closed-loop simulation that includes a proportional–integral–derivative–double-derivative governor and excitation system, allowing the DT to track plant behavior under realistic operating conditions. Unlike prior studies that treat turbine and generator modeling separately or rely mainly on simulated inputs, the proposed framework is validated using real operational data from a hydropower plant. Results show that the DT reproduces terminal voltage, active power, and reactive power with a normalized root mean square error of approximately 5%. This hybrid offline–online formulation constitutes the main contribution of the work, providing an adaptive and practically deployable DT for hydropower systems with direct relevance to control improvement, performance monitoring, and grid-support applications under high renewable penetration.

13 HYDRO ENERGY↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

A stable and accurate partitioned algorithm for conjugate heat transfer

We describe a new partitioned approach for solving conjugate heat transfer (CHT) problems where the governing temperature equations in different material domains are time-stepped in a implicit manner, but where the interface coupling is explicit. The new approach, called the CHAMP scheme (Conjugate Heat transfer Advanced Multi-domain Partitioned), is based on a discretization of the interface coupling conditions using a generalized Robin (mixed) condition. The weights in the Robin condition are determined from the optimization of a condition derived from a local stability analysis of the coupling scheme. The interface treatment combines ideas from optimized-Schwarz methods for domain-decomposition problems together with the interface jump conditions and additional compatibility jump conditions derived from the governing equations. For many problems (i.e. for a wide range of material properties, grid-spacings and time-steps) the CHAMP algorithm is stable and second-order accurate using no sub-time-step iterations (i.e. a single implicit solve of the temperature equation in each domain). In extreme cases (e.g. very fine grids with very large time-steps) it may be necessary to perform one or more sub-iterations. Each sub-iteration generally increases the range of stability substantially and thus one sub-iteration is likely sufficient for the vast majority of practical problems. The CHAMP algorithm is developed first for a model problem and analyzed using normal-mode the- ory. The theory provides a mechanism for choosing optimal parameters in the mixed interface condition. A comparison is made to the classical Dirichlet-Neumann (DN) method and, where applicable, to the optimized- Schwarz (OS) domain-decomposition method. For problems with different thermal conductivities and dif- fusivities, the CHAMP algorithm outperforms the DN scheme. For domain-decomposition problems with uniform conductivities and diffusivities, the CHAMP algorithm performs better than the typical OS scheme with one grid-cell overlap. Lastly, the CHAMP scheme is also developed for general curvilinear grids and CHT ex- amples are presented using composite overset grids that confirm the theory and demonstrate the effectiveness of the approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inertia estimation for power grids: A review of methods, challenges, and future prospects

The electric power grid is undergoing a significant transformation, shifting from traditional synchronous generators to inverter-based resources (IBRs) such as solar photovoltaics, wind turbines, and energy storage systems. This evolution leads to a reduction in system inertia, a critical attribute for maintaining frequency stability in response to disturbances. Consequently, the ability to monitor and estimate system inertia has become increasingly essential. This paper provides a comprehensive review of existing inertia estimation methodologies, analyzing them from multiple perspectives, including the types of data utilized, underlying estimation principles, operational modes, and system-wide applicability. A comparative summary table is included to distill commonalities and key characteristics across various studies. In addition, the paper examines practical implementations of inertia estimation across several major power systems worldwide, including the U.S. interconnections, the Nordic power system, and the U.K. grid. Key challenges are identified, particularly in estimating contributions from virtual inertia sources and load-induced inertia in increasingly converter-dominated networks. To address these emerging challenges, the paper proposes an integrated framework for real-time inertia estimation and monitoring. This framework encompasses critical components such as data acquisition, inertia estimation from both synchronous and non-synchronous sources, load-induced effects, optimization techniques, forecasting, and virtual inertia scheduling. Collectively, these elements enable dynamic, system-wide monitoring and adaptive control of grid inertia.

Inertia estimation↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs

The increasing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electric grids. Often, this pressure leads to electrical component failures, which might ignite wildfires. This work develops a novel model to balance the reliability of power network operations and the risk of wildfire ignition by opti- mizing the operational schedule of power transmission networks considering time-varying risk measures that include exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfire risk. The results demonstrate the ability of the model to significantly reduce wildfire risk without considerable load shedding.

power systems operations↗

Convex Relaxation of Grid-Connected Energy Storage System Models With Complementarity Constraints in DC OPF

Including complementarity constraints in energy storage system (ESS) models in optimization problems ensure an optimal solution will not produce a physically unrealizable control strategy where there is simultaneous charging and discharging. However, the current approaches to impose complementarity constraints require the use of non-convex optimization methods. Here, we propose a convex relaxation for a common ESS model that has terms for both charging and discharging based on a penalty reformulation for use in a model predictive control (MPC) based optimal power flow (DC OPF) problem. In this approach, the complementarity constraints are omitted and a penalty term is added to the optimization objective function. For the DC OPF problem, we provide analysis for the conditions under which the convex relaxation of the complementarity constraint ensures that a solution with simultaneous ESS charging and discharging operation is suboptimal. Simulation results demonstrating ESS behavior with and without the penalty reformulation are provided for an MPC-based DC OPF problem on multiple IEEE test systems.

25 ENERGY STORAGE↗

Economic Storage Size Optimization for Electric Vehicle Extreme-Fast Charging Stations

En-route charging infrastructure for electric vehicles is critical to support transportation needs. These charging stations are likely to have high loads and especially sharp peak loads given fast charging capabilities needed to meet transportation schedules. In order to reduce both strain on distribution grid infrastructure and charging station operational costs, many stations are likely to employ behind the meter storage. This paper demonstrates a behind the meter storage sizing optimization that employs an open-source agent-based vehicle behavior model (BEAM) to determine the best sizing across many scenarios. This optimization and analysis is novel in that it examines how storage size impacts not only charging station cost and peak load, but also vehicle queue times. The optimization is also applied across a wide analysis region with sufficient diversity and numbers to provide novel statistical analysis of optimal sizes.

Aka, Julius↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Performance Assessment of Pakistani Central Receiver Plant Case Study Using Aimpoint Strategy Optimization Tools

Pakistan has a high potential for both photovoltaic and Concentrated Solar Power (CSP) deployment to meet its energy requirements. Previous feasibility studies have shown that a variety of CSP technologies are both technically and economically viable in the Pakistani climate and can significantly mitigate the country's current lack of grid reliability. This work aims to enhance the performance of a previously designed Central Receiver System (CRS) plant for Pakistan using state-of-the-art aimpoint optimization methods. Results from our case study show that optimized aiming strategies have increased practicality due to their adherence to flux limitations on the receiver, and offer ~2.4% more thermal energy delivered to the receiver for the Pakistani case study compared to modern performance characterization software, translating to up to 149 additional hours of nameplate-capacity production to address the shortfall in an electricity-starved market.

central receiver system↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Optimal Sizing of a Solar-Plus-Storage System for Utility Bill Savings and Resiliency Benefits

Solar-plus-storage systems can achieve significant utility savings in behind-the-meter deployments in buildings, campuses, or industrial sites. Common applications include demand charge reduction, energy arbitrage, time-shifting of excess photovoltaic (PV) production, and selling ancillary services to the utility grid. These systems can also offer some energy resiliency during grid outages. It is often difficult to quantify the amount of resiliency that these systems can provide, however, and this benefit is often undervalued or omitted during the design process. We propose a method for estimating the resiliency that a solar-plus-storage system can provide at a given location. We then present an optimization model that can optimally size the system components to minimize the lifecycle cost of electricity to the site, including the costs incurred during grid outages. The results show that including the value of resiliency during the feasibility stage can result in larger systems and increased resiliency.

14 SOLAR ENERGY↗

Resilient off-grid microgrids: Capacity planning and N-1 security

Over the past century the electric power industry has evolved to support the delivery of power over long distances with highly interconnected transmission systems. Despite this evolution, some remote communities are not connected to these systems. These communities rely on small, disconnected distribution systems, i.e., microgrids to deliver power. However, as microgrids often are not held to the same reliability standards as transmission grids, remote communities can be at risk for extended blackouts. To address this issue, we develop an optimization model and an algorithm for capacity planning and operations of microgrids that include N-1 security and other practical modeling features like AC power flow physics, component efficiencies and thermal limits. Lastly, we demonstrate the computational effectiveness of our approach on two test systems; a modified version of the IEEE 13 node test feeder and a model of a distribution system in a remote community in Alaska.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Models and Simulation Environment for the Design and Optimization of Hybrid Energy Systems

The energy landscape in the U.S. is changing with proposed federal regulations limiting carbon dioxide emissions and with government credits for 'clean' energy technologies. This shift in the market conditions, especially in deregulated markets, has already resulted in the closing of coal power plants. Previously these coal plants served to balance variation in load. The resulting loss of electricity production is being made up in part with increased renewable generation. This set of governmental policy changes potentially presents expanded opportunities for both renewable energy and nuclear energy to become significant energy sources in the future. Potential synergies exist that can reduce greenhouse gas (GHG) emissions and provide affordable, sustainable energy. Combining multiple energy production, conversion, storage, and consumption facilities can leverage these potential synergies. This research focuses on integrating nuclear power plants within systems with increased renewable penetration, referred to as a nuclear renewable hybrid energy system (NRHES). Industrial-scale nuclear renewable hybrid energy systems have the potential to provide grid services such as dispatchable generation, storage, ancillary services, and power regulation. The problem of designing, analyzing, and optimizing the NHRES is being undertaken by a multi-laboratory team. The effort requires the collaboration of experts across engineering disciplines with methods and results to be shared by these experts. To facilitate collaborations a common system modeling and analysis language is adopted along with open-source libraries and interface standards that support data exchange among the models. Modelica was selected as the common language based on its prior use by team members at each of Idaho National Laboratory, Oak Ridge National Laboratory, and Argonne National Laboratory.