Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Pressure drop of two-phase plug flow in round mini-channels: Influence of surface wettability

In the present experimental study, the pressure drop of two-phase plug flows in round mini-channels was investigated for three different tube materials, i.e., glass, polyurethane and Teflon, respectively, with their inner diameters ranging from 1.62 to 2.16 mm. Air and water were used as the test fluids. In the wet-plug flow regime (wet wall condition at the gas portions), the pressure drop was reasonably predicted by the homogeneous flow model or by the correlations of Mishima and Hibiki [K. Mishima, T. Hibiki, Some characteristics of air-water two-phase flow in small diameter vertical tubes, Int. J. Multiphase Flow 22 (1996) 703-712] and Chisholm [D. Chisholm, A theoretical basis for the Lockhart-Martinelli correlation for two-phase flow, Int. J. Heat Mass Transfer 10 (1967) 1767-1778]. On the other hand, in the dry-plug flow regime (dry wall condition at the gas portions), the role of the moving contact lines turned out to be significant. To take into account the effect of the moving contact lines, a modified Lockhart-Martinelli type correlation was proposed, which fitted the measured pressure-drop data within the mean deviation of 6%. (author)

42 ENGINEERING↗

Investigation of similarity metrics for simulation based scaling analysis

Scaling analysis is a technique for characterizing degree of similarity between processes to occur in a real prototypic system and those to occur in its reduced scale (experimental) analog. In the context of nuclear reactor thermal-hydraulics and safety, scaling analysis is instrumental in assessing the applicability of data obtained from a scaled test facility for calibration of models and validation of simulation codes. Quantification of scale-related distortions is the key element in scaling analysis. In this work, we examine an approach for scaling analysis using computer simulation codes. Similarity analysis using information-theoretic approach is performed by comparing performance of experiment and application to variation of system conditions. Three different information theoretic measures namely mutual information, Kullback-Leibler divergence and overlap coefficient are selected for their potential use as metric for similarity analysis. We test the metrics by comparing them against physics-based scaling ratios, which are well known in fundamental thermal-hydraulic processes. In this exploratory analysis, a case of pressure drop of a steady-state flow through a channel is employed to test the proposed approach. It was found that in the absence of model uncertainties, mutual information serve as an effective measure of the scale effects present in the experiment. However, model uncertainty can significantly impact the quality of similarity analysis. Our analysis indicates that model uncertainties can have significant impact on the information theoretic metrics used for scaling analysis. Furthermore, if the model uncertainties exceeds beyond a critical value, the scale effect present in the experiment cannot be adequately evaluated. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation Testing of Hydrogen Generation Technology

This report describes the results of testing performed by ORNL for Photech Energies, Inc. The objective of the testing was to evaluate the efficacy of Photech's hydrogen generation reactor technology, which produces gaseous hydrogen through electrolysis. Photech provided several prototypes of their proprietary reactor for testing and the ancillary equipment, such as power supplies and electrolyte solutions, required for proper operation of the reactors. ORNL measured the production of hydrogen gas (volumetric flow of hydrogen at atmospheric pressure) as a function of input power and analyzed the composition of the output stream to determine the purity of the hydrogen content. ORNL attempted measurements on two basic versions of the prototype reactors-one version had a clear plastic outer cylinder, while another version had a stainless steel outer cylinder-but was only able to complete measurements on reactors in the plastic version. The problem observed in the stainless steel reactors was that in these reactors most of the hydrogen was produced near the anodes along with oxygen and the mixed gases made it impossible to determine the amount of hydrogen produced. In the plastic reactors the production of hydrogen gas increased monotonically with input power, and the flow rates increased faster at low input powers than they did at higher input powers. The maximum flow rate from the cathode port measured during the tests was 0.85 LPM at an input power of about 1100 W, an electrolyte concentration of 20%. The composition of the flow from the cathode port was primarily hydrogen and water vapor, with some oxygen and trace amounts of carbon dioxide. An operational mode that occurs briefly during certain operating conditions, and is characterized by flashes of light and violent bubbling near the cathode, might be attributable to the combustion of hydrogen and oxygen in the electrolyte solution.

08 HYDROGEN↗

Extreme-value statistics reveal rare failure-critical defects in additive manufacturing

Additive manufacturing enables the rapid, cost effective production of large populations of material test coupons such as tensile bars. By adopting streamlined test methods including ‘drop-in’ grips and non-contact extensometry, testing these large populations becomes more efficient. Unlike hardness tests, the tensile test provides a direct measure of yield strength, flow properties, and ductility, which can be directly incorporated into solid mechanics simulations. In the present work, over 1000 nominally identical tensile tests were used to explore the effect of process variability on the mechanical property distributions of a precipitation hardened stainless steel, 17-4PH, produced by a laser powder bed fusion process, also known as direct metal laser sintering. With this large dataset, rare defects are revealed that affect only ~2% of the population, stemming from a single build lot of material. Lastly, the rare defects caused a substantial loss in ductility and were associated with an interconnected network of porosity.

36 MATERIALS SCIENCE↗

Development of Technologies and Capabilities for Coal Energy Resources

This is the final report for the Aerojet Rocketdyne (AR) Advanced Gasification Systems Development (AGSD) project that was initiated on October 1, 2004. The project’s primary objective is to demonstrate technologies that improve the availability and efficiency of gasification-based power plants and to reduce plant capital and operational costs. The objective will be accomplished by (1) development and testing of cooled refractory liners, (2) feed system development and demonstration, (3) pilot plant definition and planning, (4) transport gasifier feed analysis, (5) coal-biomass mixture feed analysis, and (6) coal-biomass mixture pilot scale tests. Task 1, development and testing of cooled refractory liners, was conducted at CANMET Energy Technology Centre in Ottawa, Canada. The test objectives were to screen high conductivity CMC materials with alternate manufacturing methods and a variety of surface treatments for cooled metal tubes in a slagging gasifier environment. During the CMC testing, it was found that a constantly cooled CMC will survive in good conditions and that high porosity CMC resulted in high material erosion and corrosion. During cooled tube testing, it was found that hard metal spray coat and bare Haynes 188 performed the best. Task 2, feed system development and demonstration, was conducted at at the Energy and Environmental Research Center (EERC) at the University of North Dakota (UND). For tasks 2.1-2.6, the test objective was to demonstrate 400-tons/day coal feed system operation (to 1,000 psia gasifier pressures) in ultra-dense phase flow without plugging and to achieve multi-element injector flow-split non-uniformities below 2 %RSD. Testing was successfully completed with no feed system plugging of the feed system. The majority of the other Task 2 activities were associated with the Dry Solids Pump design (Task 2.8 and 2.11), development (Task 2.10), fabrication (Task 2.12), amd testing (Task 2.13-2.15). A variety of tests were performed that verified the capability of the Dry Solids Pump to consolidate various pulverized feedstocks to a state capable of sealing and sustaining downstream outlet pressures during mechanical operation of the pump as well as during periods when the pump was turned off. However, the final operating goals were not achieved. Task 3, pilot plant definition and planning, was to define requirements for an advanced commercial gasifier with a cooled liner and to establish a preferred commercial gasifier system configuration to serve as the reference point for an advanced gasifier pilot plant concept definition. A pilot plant concept was successfully defined that is scalable and traceable to the commercial gasifier configuration. The schedule and cost for design, installation, and long-duration test operation of a pilot plant were estimated at 33 months and $\$$25.6M. Taks 4, transport gasifier feed analysis, was to determine the effects of larger sized transport gasifier low rank coals within the AR dry solids pump. It was found for the two low-rank +100 mesh size transport gasifier coals that the cohesion of these larger materials was significantly less than the coals ground to minus 200 mesh. Also, the gas permeability of the MSL transport coal was found to be significantly higher than the permeability of the PRB transport coal. Task 5, coal-biomass mixture feed analysis, was to determine the effects of coal biomass blends within the AR ultra-dense phase feed system and dry solids pump, and to determine the cost of electricity increase of an integrated gasification combined cycle (IGCC) operating on coal/biomass blends with the AR dry solids pump and ultra-dense phase feed system. In summary, it was found that 75/25 wt% coal/corn stover blends produce reasonable economic results for IGCC operation with minimal dry solids pump modifications – especially if the coal is a low rank coal and the corn stover biomass is pelletized. The increase in electricity cost was found to be 1.1 cents/kWh. Task 6, coal-biomass mixture pilot scale tests, was to determine which coal/biomass blends could be tested in the current dry solids pump without major modifications. As reported in detail in the reports by Sprouse (2010) and Sprouse and Darby (2013), the coal/biomass blend having the least impact on pump configuration and operation is the 90/10 wt% Illinois #6 to corn stover ratio blend. The AGSD program was initiated on October 1, 2004. The interim final report was submitted on October 21, 2010 and covered Task 1, Task 2.1-2.9, and Task 3, performed during budget period 1. This final report covers Task 2.10-2.16, 4, 5, and 6, performed during budget period 2. The interim final report is attached as part of the appendix to this report.

Darby, Alan K.↗

Development and Validation of SAM Multi-dimensional Flow Model for Thermal Mixing and Stratification Modeling

Thermal mixing and stratification in large pools or enclosures are very important phenomena that are critical to nuclear reactor safety. Because of the wide ranges of time and length scales associated with such phenomena, accurate modeling and simulation of thermal mixing and stratification remain as the key unresolved, challenging problems for reactor transient analyses. In traditional system analysis codes, simplified zero-dimensional (0-D) models are widely used for their high numerical efficiency, but they generally suffer from very limited prediction accuracies or range of applicability. Like traditional system analysis codes, the current version of the SAM code has implemented such simplified 0-D and one-dimensional mixing models. On the other hand, high-resolution Computational Fluid Dynamics (CFD) tools are often used to model complex thermal mixing and stratification phenomena. They are, however, generally numerically expensive, and they require large amounts of computational resources. It is therefore desirable to implement advanced and efficient thermal mixing and stratification modeling capabilities embedded in a system analysis code. This approach will improve the accuracy of reactor safety analyses when thermal mixing and stratification are involved, and also avoid using the large computational resources needed for high-resolution CFD analysis. Currently, with the support of the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation program, an effort has been launched to develop and implement a multi-dimensional flow model in the system analysis code SAM, and demonstrate its applications to model thermal mixing and stratification phenomena in large enclosures. The main outcomes of this research and development activity are summarized in this report, which presents an attempt to include a built-in advanced multi-dimensional flow model in a system analysis code with the focus on overcoming the simulation challenges of thermal mixing and stratification phenomena. In this report, we start with the introduction of existing SAM code capabilities to simulate thermal mixing and stratification phenomena, which is followed by a short summary of the multi-dimensional model implemented in the SAM code, including both the physical model and the Finite Element Method code implementation. In this study, two options were implemented in the SAM code to model turbulent flows: a relatively simple built-in turbulence model and an interface to accept externally computed turbulent viscosities (e.g., from a high- resolution CFD simulation). Code validation studies on this newly added capability were then carried out to compare SAM simulation results with experimental data from the SUPERCAVNA facility, which was designed to study the complex flow recirculation and thermal stratification phenomena relevant to sodium fast reactor designs. In this study, one transient and two steady-state test cases were used for code validation. Different approaches have been used to model the complex turbulence flow fields in the SUPERCAVNA facility. A highly simplified zero-equation turbulence model was first used, but it was determined that it is too simple to capture the complex turbulence flow fields in these test cases. Subsequently, the code validation continued with the use of turbulent viscosity data from high-resolution STAR-CCM+ CFD simulations to improve the accuracy of the results. Using this approach, the SAM simulation results showed very good agreement with both the SUPERCAVNA experimental data and STAR-CCM+ simulation results. In this report, we demonstrate the development, implementation, and successful validation of a multi-dimensional flow model in the SAM code, which aims to improve the simulation accuracy for complex thermal mixing and stratification phenomena. Lessons have also been learned, including that in cases where the flow fields are not well predicted by the zero-equation model, the iinput of turbulent viscosities from an external source can enhance the overall predictive capabilities needed to accurately capture complex thermal-hydraulic phenomena. Therefore, future research will be needed to further improve the code’s capabilities, such as by developing a more efficient and robust approach to capture the turbulence effects in the SAM code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of the Flow in the Vicinity of an Additively Manufactured Turbine Leading-Edge Using X-Ray Particle Tracking Velocimetry

X-ray particle tracking velocimetry (PTV) is performed, for the first time, to measure the velocity field inside a leading-edge of a turbine blade made by laser-additive-manufacturing (LAM) process. The traditional showerhead holes were replaced by a porous matrix in the leading-edge. The flow through such a leading-edge piece cannot be faithfully recreated by traditional prototype testing methods due to the surface roughness and imperfections caused by LAM process. Hence, direct measurement is the only option. However, it is difficult to measure flow inside such pieces with traditional velocimetry measurements due to the existence of metallic walls. Moreover, small internal size and high flow speeds call for a measurement technique with high spatial and temporal resolutions. To address these issues, we performed time-resolved X-ray PTV using the Advanced Photon Source (APS) synchrotron facility at the Argonne National Laboratory (ANL). A hydraulic system was constructed to run water, mixed with seeding particles, through the leading-edge piece. A high-speed camera captured the images of the seeding particles, which were later processed to create particle tracks. The time-averaged velocity field showed distinct pairs of vortices located in front of the porous outlet inside the leading-edge piece. The inlet channel showed reversed flow due to partial obstruction by the porous inlet of the test piece. Such knowledge of the flow field inside a leading-edge of a turbine blade will help us to design better cooling paths leading to higher cooling efficiency and increased life-span of a turbine blade.

42 ENGINEERING↗

A statistical model to predict ignition probability

Ignition capability is a critical design constraint for aeronautical gas turbines. However the current trend toward overall lean burn is detrimental to the engine ignition and relight and the ignition system must be adapted to ensure a fast and reliable light-round in all circumstances. As ignition is a stochastic phenomenon, the optimization of an ignition system requires to build ignition probability maps, which is difficult and costly with either experiment or numerical simulation as both require many tests. Here, this work proposes a model to predict the ignition probability map, knowing only flow statistics in non-reacting conditions, i.e., with only one test. The originality of the model is to construct statistics of the flame kernel trajectory, which are then combined with local flow indicators to evaluate the ignition probability at the considered sparking location. Application to a swirled burner operated in premixed, non-premixed and spray combustion modes illustrates the model concepts and demonstrates its ability to recover the experimental ignition map with good accuracy.

42 ENGINEERING↗

High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems

This report summarizes the progress made during the April 01, 2010 – December 30, 2013 period under Cooperative Agreement DE-EE0002752 for the U.S. Department of Energy entitled “High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems.” The overall objective of this program is to advance the technology for well fluids lifting systems to meet the foreseeable pressure, temperature, and longevity needs of the Enhanced Geothermal Systems (EGS) industry for the coming ten years. In this program, lifting system requirements for EGS wells were established via consultation with industry experts and site visits. A number of artificial lift technologies were evaluated with regard to their applicability to EGS applications; it was determined that a system based on electric submersible pump (ESP) technology was best suited to EGS. Technical barriers were identified and a component-level technology development program was undertaken to address each barrier, with the most challenging being the development of a power-dense, small diameter motor that can operate reliably in a 300°C environment for up to three years. Some of the targeted individual component technologies include permanent magnet motor construction, high-temperature insulation, dielectrics, bearings, seals, thrust washers, and pump impellers/diffusers. Advances were also made in thermal management of electric motors. In addition to the overall system design for a full-scale EGS application, a subscale prototype was designed and fabricated. Like the full-scale design, the subscale prototype features a novel “flow-through-the-bore” permanent magnet electric motor that combines the use of high temperature materials with an internal cooling scheme that limits peak internal temperatures to <330°C. While the full-scale high-volume multi-stage pump is designed to lift up to 80 kg/s of process water, the subscale prototype is based on a production design that can pump 20 kg/s and has been modified for high-temperature operation. In parallel with the design and fabrication of the subscale prototype ESP system, a subscale test facility consisting of a high-temperature-high-pressure flow loop was designed, fabricated, and installed at GE Global Research in Niskayuna, NY. A test plan for the prototype system was also established. The original plan of testing the prototype hardware in the flow loop was delayed until a future date.

15 GEOTHERMAL ENERGY↗

Chemical Kinetics Underlying the Sooting Tendency and Auto-Ignition Characteristics of Linear, Branched, and Cyclic Ether Compounds

Biofuels present opportunities for improving the performance and reducing emissions from internal combustion engines by incorporating oxygenated functional groups to the fuels. Among various oxygenates, ethers have been recognized as promising candidates for an alternative to conventional diesel fuel owing to their higher reactivity and lower sooting tendency. The detailed guidelines for designing ethers, however, have not been fully discussed, even though their combustion characteristics are sensitive to the molecular structure. This study was devoted to exploring the structure-property relationships, particularly focusing on the cetane number and yield sooting index, using five linear, branched, and cyclic ethers: di-amyl-ether, 4-butoxy-heptane, 3,3-dimethyl-oxetane, 2-ethyl-4-methyl-1,3-dioxolane, and 2-isopropyl-4-methyl-1,3-dioxolane. First, we examined the chemical kinetics underlying the sooting tendency of the test fuels. The combustion product distribution was measured from flow reactor experiments at 750-1100 K, F=3, at atmospheric pressure. As a result, it was revealed that the sooting tendency is closely related to the size of hydrocarbon intermediates in the high-temperature regime (>1000 K); that is, larger hydrocarbons lead to more soot precursor formation. The underlying chemistry determining the size of the hydrocarbons from the tested fuels was analyzed using reaction pathway analysis and quantum mechanics calculations, which showed that the branched and cyclic ether structures form abundant C3-C4 compounds. Moreover, the auto-ignition characteristics of the test fuels were studied using the flow reactor at low-temperature (400-700 K) and F=1. We found a clear difference in the combustion-product distribution from high and low reactivity fuels, which was then correlated to the systematic analysis of the key reaction energy barriers with the varying molecular structure.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

Neutron Imaging of a Two-Phase Refrigerant Flow

Void fraction remains a crucial parameter in understanding and characterizing two-phase flow. It appears as a key variable in both heat transfer and pressure drop correlations of two-phase flows, from the macro to micro- channel scale. Void fraction estimation dictates the sizing of both evaporating and condensing phase change heat exchangers, for example. In order to measure void fraction some invasive approach is necessary. Typically, visualization is achieved either downstream of the test section or on top by machining to expose the channel. Both approaches can lead to inaccuracies. The former assumes the flow will not be affected moving from the heat exchanger surface to the transparent section. The latter distorts the heat flow path. Neutron Imaging can provide a non-invasive measurement because metals such as Aluminum are essentially transparent to neutrons. Hence, if a refrigerant is selected that provides suitable neutron attenuation; steady-state void fraction measurements in two-phase flow are attainable in-situ without disturbing the fluid flow or heat flow path. Neutron Imaging has been used in the past to qualitatively describe the flow in heat exchangers in terms of maldistributions without providing void fraction data. This work is distinguished from previous efforts because the heat exchanger has been designed and the refrigerant selected to avail of neutron imaging. This work describes the experimental flow loop that enables a boiling two-phase flow; the heat exchanger test section and downstream transparent section are described. The flow loop controls the degree of subcooling and the refrigerant flowrate. Heating cartridges embedded in the test section are employed to control the heat input. Neutron-imaged steady-state void fraction measurements are captured and compared to representative high-speed videography captured at the visualization section. This allows a qualitative comparison between neutron imaged and traditional techniques. The measurements are also compared to correlations in the literature. Preliminary void fraction images from a macro-channel flow are presented, consisting of 1 channel, 4mm wide, 4mm high and 83.32mm long. Flow regime identification is examined. The experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA.

Geoghegan, Patrick J↗

Accelerated Irradiation Testing and Post-Irradiation Characterization: U.S.-Based Capabilities for Advanced Nuclear Systems and Radioisotope Production

Irradiation experiments and post-irradiation examinations, together referred to as irradiation testing (IRT), are prerequisites for nuclear fuel and material qualification for the deployment of new and advanced reactors, as well as radioisotope production, thereby ensuring regulatory compliance. Qualified research and test reactors (RTRs) and testing facilities are essential to enable IRT to verify performance and safety under prototypical reactor conditions. In the past, qualification of new fuels or structural materials required about 20 years. Synergist strategies, advanced tools, and qualified methods are needed to greatly reduce this timeframe of IRT and radioisotope production. This study, termed accelerated-IRT, focuses on identifying gaps and leveraging U.S.-based RTRs and material testing capabilities, leveraging the preliminary evaluation and qualification of selected RTRs to provide a generic as well as specific-case solution paths forward, ensuring adherence to stringent regulatory standards. Furthermore, IRT and radioisotope production utilizing qualified RTRs necessarily includes modeling and simulation to support the design (i.e. neutronics, thermal, and structural aspects) and manufacturing of irradiation test specimens, vehicles, capsules, apparatuses, and flow loops. In addition, IRT can be improved by applying advanced manufacturing techniques and in-pile sensors and instrumentation, as discussed in this study.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Combined Transmission and Distribution Test System to Study High Penetration of Distributed Solar Generation

Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.

Samaan, Nader A.↗

Mechanical annealing in the flow of supercooled metallic liquid

Flow induced structural evolution in a supercooled metallic liquid Vit106a (Zr{sub 58.5}Cu{sub 15.6}Al{sub 10.3}Ni{sub 12.8}Nb{sub 2.8}, at. %) was investigated via uni-axial compression combined with differential scanning calorimeter (DSC). Compression tests at strain rates covering the transition from Newtonian flow to non-Newtonian flow and at the same strain rate 2 × 10{sup −1} s{sup −1} to different strains were performed at the end of glass transition (T{sub g-end} = 703 K). The relaxation enthalpies measured by DSC indicate that the samples underwent non-Newtonian flow contain more free volume than the thermally annealed sample (703 K, 4 min), while the samples underwent Newtonian flow contain less, namely, the free volume of supercooled metallic liquids increases in non-Newtonian flow, while decreases in Newtonian flow. The oscillated variation of the relaxation enthalpies of the samples deformed at the same strain rate 2 × 10{sup −1} s{sup −1} to different strains confirms that the decrease of free volume was caused by flow stress, i.e., “mechanical annealing.” Micro-hardness tests were also performed to show a similar structural evolution tendency. Based on the obtained results, the stress-temperature scaling in the glass transition of metallic glasses are supported experimentally, as stress plays a role similar to temperature in the creation and annihilation of free volume. In addition, a widening perspective angle on the glass transition of metallic glasses by exploring the 3-dimensional stress-temperature-enthalpy phase diagram is presented. The implications of the observed mechanical annealing effect on the amorphous structure and the work-hardening mechanism of metallic glasses are elucidated based on atomic level stress model.

36 MATERIALS SCIENCE↗

Convective heat transfer in a high aspect ratio minichannel heated on one side

Experimental results are presented for single-phase heat transfer in a narrow rectangular minichannel heated on one side. The aspect ratio and gap thickness of the test channel were 29:1 and 1.96 mm, respectively. Friction pressure drop and Nusselt numbers are reported for the transition and fully turbulent flow regimes, with Prandtl numbers ranging from 2.2 to 5.4. Turbulent friction pressure drop for the high aspect ratio channel is well-correlated by the Blasius solution when a modified Reynolds number, based upon a laminar equivalent diameter, is utilized. The critical Reynolds number for the channel falls between 3500 and 4000, with Nusselt numbers in the transition regime being reasonably predicted by Gnielinski's correlation. The dependence of the heat transfer coefficient on the Prandtl number is larger than that predicted by circular tube correlations, and is likely a result of the asymmetric heating. The problem of asymmetric heating condition is approached theoretically using a boundary layer analysis with a two-region wall layer model, similar to that originally proposed by Prandtl. The analysis clarifies the influence of asymmetric heating on the Nusselt number and correctly predicts the experimentally observed trend with Prandtl number. Furthermore, a semi-analytic correlation is derived from the analysis that accounts for the effect of aspect ratio and asymmetric heating, and is shown to predict the experimental results of this study with a mean absolute error (MAE) of less than 5% for 4000 < Re < 70,000.

42 ENGINEERING↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗