Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Subframe Burst Gating for Raman Spectroscopy in Combustion

We describe an architecture for spontaneous Raman scattering utilizing a frame-transfer CCD sensor operating in a subframe burst-gating mode to realize time-resolved combustion diagnostics. The technique permits all-electronic optical gating with microsecond shutter speeds 5 J.Ls) without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally polarized excitation lasers, the technique measures single-shot vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Kojima, Jun↗

Cryogenic Amplifier Based Receivers at Submillimeter Wavelengths

The operating frequency of InP high electron mobility transistor (HEMT) based amplifiers has moved well in the submillimeter-wave frequencies over the last couple of years. Working amplifiers with usable gain in waveguide packages has been reported beyond 700 GHz. When cooled cryogenically, they have shown substantial improvement in their noise temperature. This has opened up the real possibility of cryogenic amplifier based heterodyne receivers at submillimeter wavelengths for ground-based, air-borne, and space-based instruments for astrophysics, planetary, and Earth science applications. This paper provides an overview of the science applications at submillimeter wavelengths that will benefit from this technology. It also describes the current state of the InP HEMT based cryogenic amplifier receivers at submillimeter wavelengths.

cryogenically cooled superconductorinsulator- supe↗

Simplified feedback control system for scanning tunneling microscopy

A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).

Martín-Vega, Francisco (ORCID:0000000333177833)↗

Electron cyclotron emission quasi-optical transmission system on the HL-3 tokamak

A new quasi-optical (QO) Electron Cyclotron Emission (ECE) transmission system has been established on the HL-3 tokamak, which includes a focusing QO mirror combination and a long-distance transmission line. This system was developed to meet the requirements for poloidal spatial resolution and the high signal-to-noise ratio needed for magnetohydrodynamic (MHD) instability studies using ECE on the HL-3. The QO mirror combination was installed inside the vacuum chamber for focusing. Laboratory test results, theoretical calculations, and synthetic ECE simulation results indicate that the Gaussian beam can meet the spatial resolution requirements for the accurate measurement of the MHD instability on the q = 1/2/3 surfaces, corresponding to the poloidal mode numbers m = 3/6/9. This includes good diagnostic poloidal spatial resolution for the important 2/1 and 3/2 modes. At the front end of the transmission line, a high-efficiency mode converter was designed to transition the TE 10 mode to the HE 11 mode for input into the transmission line, with an insertion loss of less than 1.5 dB. A 30 m long-distance corrugated oversized waveguide was constructed, with transmission losses ranging from 6 to 10 dB in the 60–120 GHz range. Polarization adjustment results show that the polarization offset and geometric spatial polarization angle change consistently, which can provide a reference for polarization adjustment in other complex structured transmission lines. As a result, the newly established ECE QO transmission system will provide strong support for future physics research involving ECE on the HL-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution sounding rocket observations of large-amplitude Alfven waves

Shear Alfven waves with amplitudes greater than 100 mV/m were observed on two recent sounding rocket flights. The largest waveforms are best described as a series of step functions, rather than as broadband noise or as single frequency waves. Complete two-dimensional E and B measurements at 4-ms time resolution were made, showing a downward propagation direction and implying insignificant reflection from the ionosphere at frequencies greater than 1 Hz. Intense, field-aligned, low-energy electron fluxes accompany the waves. Acceleration of these electrons by the Alfven waves is shown to be feasible. The waves in at least one case have a sufficently large ponderomotive potential to generate the observed density fluctuations of order one.

Boehm, M. H.↗

Quantum correlation between the junction-voltage fluctuation and the photon-number fluctuation in a semiconductor laser

The photon-number fluctuation of the external field from a semiconductor laser - which was reduced to below the standard quantum limit - is shown to be correlated with the measured junction-voltage noise. The spectral density of the sum of the photon-number fluctuation and junction-voltage fluctuation falls below the squeezed photon-number fluctuation. This confirms the theoretical predictions that this correlation, which originates in the dipole interaction between the internal field and electron-hole pairs, extends into the quantum regime.

Richardson, W. H.↗

Goals for the application of high-resolution X-ray spectroscopy to the diagnosis of stellar coronal plasmas

Examples are provided of how high-resolution X-ray spectra may be used to determine the temperature and emission measure distributions, electron densities, steady and transient flow velocities, and location of active regions in stellar coronas. For each type of measurement, the minimum spectral resolution required to resolve the most useful spectral features is estimated. In general, high sensitivity is required to obtain sufficient signal-to-noise to exploit the high spectral resolution. Although difficult, each measurement should be achievable with the instrumentation proposed for AXAF.

Linsky, Jeffrey L.↗

Controlling Force and Depth in Friction Stir Welding

Feedback control of the penetration force applied to a pin tool in friction stir welding has been found to be a robust and reliable means for controlling the depth of penetration of the tool. This discovery has made it possible to simplify depth control and to weld with greater repeatability, even on workpieces with long weld joints. Prior to this discovery, depths of penetration in friction stir welding were controlled by hard-tooled roller assemblies or by depth actuators controlled by feedback from such external sensors as linear variable-differential transformers or laser-based devices. These means of control are limited: A hard-tooled roller assembly confines a pin tool to a preset depth that cannot be changed easily during the welding process. A measurement by an external sensor is only an indirect indicative of the depth of penetration, and computations to correlate such a measurement with a depth of penetration are vulnerable to error. The present force-feedback approach exploits the proportionality between the depth and the force of penetration Unlike a depth measurement taken by an external sensor, a force measurement can be direct because it can be taken by a sensor coupled directly to the pin tool. The reading can be processed through a modern electronic servo control system to control an actuator to keep the applied penetration force at the desired level. In comparison with the older depth-control methods described above, this method offers greater sensitivity to plasticizing of the workpiece metal and is less sensitive to process noise, resulting in a more consistent process. In an experiment, a tapered panel was friction stir welded while controlling the force of penetration according to this method. The figure is a plot of measurements taken during the experiment, showing that force was controlled with a variation of 200 lb (890 N), resulting in control of the depth of penetration with a variation of 0.004 in. (0.1 mm).

Adams, Glynn↗

Interference-free optical detection for Raman spectroscopy

An architecture for spontaneous Raman scattering (SRS) that utilizes a frame-transfer charge-coupled device (CCD) sensor operating in a subframe burst gating mode to realize time-resolved combustion diagnostics is disclosed. The technique permits all-electronic optical gating with microsecond shutter speeds (<5 .mu.s), without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally-polarized excitation lasers, the technique measures time-resolved vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Nguyen, Quang-Viet↗

Advances in ultrafast gas-phase x-ray scattering

Recent developments of x-ray free electron lasers and pulsed electron sources have enabled ultrafast scattering to become an increasingly powerful tool for exploring molecular dynamics. Here, this article describes our recent experimental and methodological advances in ultrafast gas-phase x-ray scattering experiments at the LCLS. A re-designed short-pathlength windowless diffractometer is coupled with careful optimization of sample density and independent normalization of x-ray intensity fluctuations to provide gas-phase scattering patterns with exceptionally high signal-to-noise ratios. These advances, coupled with careful geometry optimization and data treatment, provide both ground- and excited-state signals in excellent agreement with high level ab initio total scattering patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Filling data analysis gaps in time-resolved crystallography by machine learning

There is a growing understanding of the structural dynamics of biological molecules fueled by x-ray crystallography experiments. Time-resolved serial femtosecond crystallography (TR-SFX) with x-ray Free Electron Lasers allows the measurement of ultrafast structural changes in proteins. Nevertheless, this technique comes with some limitations. One major challenge is the quality of data from TR-SFX measurements, which often faces issues like data sparsity, partial recording of Bragg reflections, timing errors, and pixel noise. To overcome these difficulties, conventionally, large volumes of data are collected and grouped into a few temporal bins. The data in each bin are then averaged and paired with the mean of their corresponding jittered timestamps. This procedure provides one structure per bin, resulting in a limited number of averaged structures for the entire time interval spanned by the experiment. Therefore, the information on ultrafast structural dynamics at high temporal resolution is lost. This has initiated research for advanced methods of analyzing experimental TR-SFX data beyond the standard binning and averaging method. To address this problem, we use a machine learning algorithm called Nonlinear Laplacian Spectral Analysis (NLSA), which has emerged as a promising technique for studying the dynamics of complex systems. In this work, we demonstrate the power of this algorithm using synthetic x-ray diffraction snapshots from a protein with significant data incompleteness, timing uncertainties, and noise. Our study confirms that NLSA is a suitable approach that effectively mitigates the effects of these artifacts in TR-SFX data and recovers accurate structural dynamics information hidden in such data.

Trujillo, Justin (ORCID:0000000285505360)↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

New Techniques for High-Contrast Imaging with ADI: The ACORNS-ADI SEEDS Data Reduction Pipeline

We describe Algorithms for Calibration, Optimized Registration, and Nulling the Star in Angular Differential Imaging (ACORNS-ADI), a new, parallelized software package to reduce high-contrast imaging data, and its application to data from the Strategic Exploration of Exoplanets and Disks (SEEDS) survey. We implement seyeral new algorithms, includbg a method to centroid saturated images, a trimmed mean for combining an image sequence that reduces noise by up to approx 20%, and a robust and computationally fast method to compute the sensitivitv of a high-contrast obsen-ation everywhere on the field-of-view without introducing artificial sources. We also include a description of image processing steps to remove electronic artifacts specific to Hawaii2-RG detectors like the one used for SEEDS, and a detailed analysis of the Locally Optimized Combination of Images (LOCI) algorithm commonly used to reduce high-contrast imaging data. ACORNS-ADI is efficient and open-source, and includes several optional features which may improve performance on data from other instruments. ACORNS-ADI is freely available for download at www.github.com/t-brandt/acorns_-adi under a BSD license

Brandt, Timothy D.↗

Microelectronic DNA assay for the detection of BRCA1 gene mutations

Mutations in BRCA1 are characterized by predisposition to breast cancer, ovarian cancer and prostate cancer as well as colon cancer. Prognosis for this cancer survival depends upon the stage at which cancer is diagnosed. Reliable and rapid mutation detection is crucial for the early diagnosis and treatment. We developed an electronic assay for the detection of a representative single nucleotide polymorphism (SNP), deletion and insertion in BRCA1 gene by the microelectronics microarray instrumentation. The assay is rapid, and it takes 30 minutes for the immobilization of target DNA samples, hybridization, washing and readout. The assay is multiplexing since it is carried out at the same temperature and buffer conditions for each step. The assay is also highly specific, as the signal-to-noise ratio is much larger than recommended value (72.86 to 321.05 vs. 5) for homozygotes genotyping, and signal ratio close to the perfect value 1 for heterozygotes genotyping (1.04).

Validation Studies↗

First Demonstration of Resonant Pitch-Angle Scattering of Relativistic Electrons by Externally Launched Helicon Waves

Helicon waves (a.k.a whistler waves) satisfying the normal wave-particle cyclotron resonance are observed to limit the growth and maximum energy of relativistic electrons (REs) in low-density Ohmic DIII-D tokamak plasmas. Following the application of helicon waves, pitch-angle scattering of high-energy REs causes an increase in both synchrotron and electron-cyclotron emissions. The hard x-ray emission, a proxy for the RE population, ceases to grow. Energy-resolved hard x-ray measurements also show a striking decrease in the number of high-energy REs (above the resonance at approximately 8MeV) to below the noise floor and an increase in low-energy (∼ 4 MeV) REs. This occurs despite the toroidal electric field remaining high enough to drive exponential RE growth in the absence of helicon waves. Furthermore, these results open new directions for limiting the maximum energy of RE populations in laboratory and fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrochemical studies in aluminum chloride melts

A melt purification system was developed which produces a final melt far superior electrochemically than those previously reported. A residual current of less than 2 microamps/sq mn at a sweep rate of 0.5 V/sec was used as the criteria for a pure melt. The use of a second purified bulk melt and a heated pipette permitted the rapid exchange of working electrode compartments while retaining the same reference electrode system. The major portion of the work was carried out in the 1:1 AlCl3:NaCl melt at 175 and 200 C. Several measurements were made in the 2:1 melt and a few on the silver systems in intermediate compositions. Programs for PDP-8I and PDP-12 digital computers and the required electronic circuitry systems were developed to carry out various electrochemical measurements in the melt. A pair of 50 yard transmission lines were used to connect the computer to the experiment. Ensemble averaging and digital, least squares smoothing are used within the programs to improve the signal-to-noise ratio by at least an order of magnitude. Some of the computerized electrochemcial techniques used to examine the different systems were pulse polarography, double pulse polarography, staircase voltammetry, kinetic double potential step chronoamperometry and double potential step chronocoulometry.

Osteryoung, R. A.↗