Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference beacons

We present a new method to directly measure and correct the aberrations introduced when imaging through thick biological tissue. A Shack-Hartmann wavefront sensor is used to directly measure the wavefront error induced by a Drosophila embryo. The wavefront measurements are taken by seeding the embryo with fluorescent microspheres used as “artificial guide-stars.” The wavefront error is corrected in ten millisecond steps by applying the inverse to the wavefront error on a micro-electromechanical deformable mirror in the image path of the microscope. The results show that this new approach is capable of improving the Strehl ratio by 2 times on average and as high as 10 times when imaging through 100 µm of tissue. The results also show that the isoplanatic half-width is approximately 19 µm resulting in a corrected field of view 38 µm in diameter around the guide-star.

59 BASIC BIOLOGICAL SCIENCES↗

Active phase correction of high resolution silicon photonic arrayed waveguide gratings

Arrayed waveguide gratings provide flexible spectral filtering functionality for integrated photonic applications. Achieving narrow channel spacing requires long optical path lengths which can greatly increase the footprint of devices. High index contrast waveguides, such as those fabricated in silicon-on-insulator wafers, allow tight waveguide bends which can be used to create much more compact designs. Both the long optical path lengths and the high index contrast contribute to significant optical phase error as light propagates through the device. Thus, silicon photonic arrayed waveguide gratings require active or passive phase correction following fabrication. We present the design and fabrication of compact silicon photonic arrayed waveguide gratings with channel spacings of 50, 10 and 1 GHz. The largest device, with 11 channels of 1 GHz spacing, has a footprint of only 1.1 cm 2 . Using integrated thermo-optic phase shifters, the phase error is actively corrected. We present two methods of phase error correction and demonstrate state-of-the-art cross-talk performance for high index contrast arrayed waveguide gratings. As a demonstration of possible applications, we perform RF channelization with 1 GHz resolution. In addition, we generate unique spectral filters by applying non-zero phase offsets calculated by the Gerchberg Saxton algorithm.

36 MATERIALS SCIENCE↗

Nanometer flat blazed x-ray gratings using ion beam figure correction

With the development of nanometer accuracy stitching interferometry, ion beam figuring (IBF) of x-ray mirrors can now be achieved with unprecedented performance. However, the process of producing x-ray diffraction gratings on these surfaces may degrade the figure quality due to process errors introduced during the ruling of the grating grooves. To address this challenge, we have investigated the post-production correction of gratings using IBF, where stitching interferometry is used to provide in-process feedback. A concern with ion beam correction in this case is that ions will induce enough surface mobility of atoms to cause smoothing of the grating structure and degradation of diffraction efficiency. In this study we found however that it is possible to achieve a nanometer-level planarity of the global grating surface with IBF, while preserving the grating structure. The preservation was so good, that we could not detect a change in the diffraction efficiency after ion beam correction. This is of major importance in achieving ultra-high spectral resolution, and the preservation of brightness for coherent x-ray beams.

36 MATERIALS SCIENCE↗

Radiative Corrections to the PREX and QWEAK Experiments

The high precision parity violating electron scattering experiments PREX and QWEAK are sensitive to radiative corrections. In this paper we introduce the PREX experiment that measures the neutron radius of {sup 208}Pb and discuss coulomb distortion corrections. We then discuss dispersion corrections for QWEAK that aims to measure the weak charge of the proton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Regional-Scale 3D Ground-Motion Simulations of M w 7 Earthquakes on the Hayward Fault, Northern California Resolving Frequencies 0–10 Hz and Including Site-Response Corrections

Large earthquake ground-motion simulations in 3D Earth models provide constraints on site-specific shaking intensities but have suffered from limited frequency resolution and ignored site response in soft soils. In this work we report new regional-scale 3D simulations for moment magnitude 7.0 scenario earthquakes on the Hayward Fault, northern California with SW4. Simulations resolved significantly broader band frequencies (0–10 Hz) than previous studies and represent the highest resolution simulations for any such earthquake to date. Seismic waves were excited by a kinematic rupture following Graves and Pitarka (2016) and obeyed wave propagation in a 3D Earth model with topography from the U.S. Geological Survey (USGS) assuming a minimum shear wavespeed, VSmin, of 500 m/s. We corrected motions for linear and nonlinear site response for the shear wavespeed, VS, from the USGS 3D model, using a recently developed ground-motion model (GMM) for Fourier amplitude spectra . At soft soil locations subjected to strong shaking, the site-corrected intensities reflect the competing effects of linear amplification by low V S material, reduction of stiffness during nonlinear deformation, and damping of high frequencies. Sites with near-surface V S of 500 m/s or greater require no linear site correction but can experience amplitude reduction due to nonlinear response. Averaged over all sites, we obtained reasonable agreement with empirical ergodic median GMMs currently used for seismic hazard and design ground motions (epsilon less than 1), with marked improvement at soft sedimentary sites. At specific locations, the simulated shaking intensities show systematic differences from the GMMs that reveal path and site effects not captured in these ergodic models. Results suggest how next generation regional-scale earthquake simulations can provide higher spatial and frequency resolution while including effects of soft soils that are commonly ignored in scenario earthquake ground-motion simulations.

58 GEOSCIENCES↗

New Methods for Dispersion Measurement and Correction for 12GeV CEBAF

This paper discusses methods for dispersion measurement and correction for the Continuous Electron Beam Accelerator Facility (CEBAF) for the 12GeV era. New methods will be compared with methods used during the 6GeV era. New software tools which implement the new methods will be discussed, along with a method for automating dispersion measurement and correction. New dispersion measurement and correction methods and tools are being implemented to provide more deterministic results and to reduce machine setup time.

Turner, Dennis L.↗

Dynamic Aperture of JLEIC Electron Collider Ring with Errors and Correction

Design of the electron and ion rings of the Jefferson Lab Electron-Ion Collider (JLEIC) features the low-beta Interaction Regions (IR) with detector solenoid, non-linear chromaticity compensation blocks (CCB), and spin rotator optics with solenoids. The high beta functions in the IR final focus quadrupoles (FFQ) and in the CCB magnets result in strong effects of errors in these magnets. Performance of the spin rotators may also be sensitive to the errors. The first part of this study includes the design of orbit correction system for both rings and evaluation of dynamic aperture (DA) with misalignment and the correction. The second part is devoted to the DA study with the FFQ non-linear field errors. The orbit correction design, the dynamic aperture, and the impact on error specifications are presented.

Lin, F.↗

ANALYSIS OF SUITABLE METHODOLOGIES FOR COMPRESSOR MASS FLOW RATE CORRECTION TO OTHER SUPERHEAT LEVELS AND REFRIGERANTS

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Marchante Avellaneda, Javier↗

Pressure Correction in the Calibration of Heat Dissipation Sensors

Heat dissipation sensors (HDSs) infer soil matric potential based on the measured rate of temperature rise from a heat source. The process for calibrating these sensors may use a pressure plate apparatus (PPA) to remove water to a certain calibration point that is controlled by pressure. Conventionally, the pressure within the PPA is released before the temperature change calibration points are measured ( ΔT 0 ). This conventional HDS calibration approach can take several weeks. We propose that the equilibrated temperature change at pressure ( ΔT p ) can be corrected empirically to the value at zero pressure. Based on measurements of 14 HDSs between 0.02 and 0.1 MPa, ΔT p was on average 6.2% larger than ΔT 0 . After pressure correction, using an empirical equation, the difference between the corrected ΔT p and ΔT 0 was only 0.28%. These results demonstrate that this empirical approach provides sufficient accuracy to achieve HDS calibration without performing a PPA pressure release.

47 OTHER INSTRUMENTATION↗

Error Field Correction in DIII-D Ohmic Plasmas With Either Handedness

Error field correction results in DIII-D plasmas are presented in various configurations. In both left-handed and right-handed plasma configurations, where the intrinsic error fields become different due to the opposite helical twist (handedness) of the magnetic field, the optimal error correction currents and the toroidal phases of internal(I)-coils are empirically established. Applications of the Ideal Perturbed Equilibrium Code to these results demonstrate that the field component to be minimized is not the resonant component of the external field, but the total field including ideal plasma responses. Consistency between experiment and theory has been greatly improved along with the understanding of ideal plasma responses, but non-ideal plasma responses still need to be understood to achieve the reliable predictability in tokamak error field correction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada

This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility.

54 ENVIRONMENTAL SCIENCES↗

Error Detection, Factorization and Correction for Multi-View Scene Reconstruction from Aerial Imagery

Scene reconstruction from video sequences has become a prominent computer vision research area in recent years, due to its large number of applications in fields such as security, robotics and virtual reality. Despite recent progress in this field, there are still a number of issues that manifest as incomplete, incorrect or computationally-expensive reconstructions. The engine behind achieving reconstruction is the matching of features between images, where common conditions such as occlusions, lighting changes and texture-less regions can all affect matching accuracy. Subsequent processes that rely on matching accuracy, such as camera parameter estimation, structure computation and non-linear parameter optimization, are also vulnerable to additional sources of error, such as degeneracies and mathematical instability. Detection and correction of errors, along with robustness in parameter solvers, are a must in order to achieve a very accurate final scene reconstruction. However, error detection is in general difficult due to the lack of ground-truth information about the given scene, such as the absolute position of scene points or GPS/IMU coordinates for the camera(s) viewing the scene. In this dissertation, methods are presented for the detection, factorization and correction of error sources present in all stages of a scene reconstruction pipeline from video, in the absence of ground-truth knowledge. Two main applications are discussed. The first set of algorithms derive total structural error measurements after an initial scene structure computation and factorize errors into those related to the underlying feature matching process and those related to camera parameter estimation. A brute-force local correction of inaccurate feature matches is presented, as well as an improved conditioning scheme for non-linear parameter optimization which applies weights on input parameters in proportion to estimated camera parameter errors. Another application is in reconstruction pre-processing, where an algorithm detects and discards frames that would lead to inaccurate feature matching, camera pose estimation degeneracies or mathematical instability in structure computation based on a residual error comparison between two different match motion models. The presented algorithms were designed for aerial video but have been proven to work across different scene types and camera motions, and for both real and synthetic scenes.

42 ENGINEERING↗

Closure Report for Corrective Action Unit 574: Neptune, Nevada National Security Site, Nevada

Corrective Action Unit (CAU) 574 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Neptune' and consists of the following two Corrective Action Sites (CASs), located in Area 12 of the Nevada National Security Site: (1) CAS 12-23-10, U12c.03 Crater (Neptune); and (2) CAS 12-45-01, U12e.05 Crater (Blanca). This Closure Report presents information supporting closure of CAU 574 according to the FFACO (FFACO, 1996 [as amended March 2010]) and the Streamlined Approach for Environmental Restoration Plan for CAU 574 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2011). The following activities were performed to support closure of CAU 574: (1) In situ external dose rate measurements were collected using thermoluminescent dosimeters at CAS 12-45-01, U12e.05 Crater (Blanca). (2) Total effective dose rates were determined at both sites by summing the internal and external dose rate components. (3) A use restriction (UR) was implemented at CAS 12-23-10, U12c.03 Crater (Neptune). Areas that exceed the final action level (FAL) of 25 millirems per year (mrem/yr) based on the Occasional Use Area exposure scenario are within the existing use restricted area for CAU 551. The 25-mrem/yr FAL is not exceeded outside the existing CAU 551 UR for any of the exposure scenarios (Industrial Area, Remote Work Area, and Occasional Use Area). Therefore, the existing UR for CAU 551 is sufficient to bound contamination that exceeds the FAL. (4) An administrative UR was implemented at CAS 12-45-01, U12e.05 Crater (Blanca) as a best management practice (BMP). The 25-mrem/yr FAL was not exceeded for the Remote Work Area or Occasional Use Area exposure scenarios; therefore, a UR is not required. However, because the 25-mrem/yr FAL was exceeded for the Industrial Area exposure scenario, an administrative UR was established as a BMP. UR documentation is included as Appendix B. The UR at CAS 12-23-10, U12c.03 Crater (Neptune), is within the existing UR for CAU 551. Additional postings were not installed, and annual post-closure inspections will be performed in conjunction with the inspections performed for CAU 551. At CAS 12-45-01, U12e.05 Crater (Blanca), the administrative UR does not require postings or inspections. NNSA/NSO requests the following: (1) A Notice of Completion from the Nevada Division of Environmental Protection to NNSA/NSO for closure of CAU 574; and (2) The transfer of CAU 574 from Appendix III to Appendix IV, Closed Corrective Action Units, of the FFACO

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local 3Q y betatron resonance correction in the 2012 RHIC 250 GeV run

In this article we performed numerical simulations to correct the local vertical third order betatron resonance 3Qy in the interaction regions in the Yellow ring for the 2012 RHIC 250 GeV polarized proton run. Considering the main sources of skew sextupoles are located in the interaction regions, we used local bump methods to minimize their contributions to the global 3Qy resonance driving term. Two kinds of correction orbit bumps are tested and the dynamic apertures with these correction strengths are calculated and compared.

43 PARTICLE ACCELERATORS↗

Sorting chromatic sextupoles for easily and effectively correcting second order chromaticity in the Relativistic Heavy Ion Collider

Based on the contributions of the chromatic sextupole families to the half-integer resonance driving terms, we discuss how to sort the chromatic sextupoles in the arcs of the Relativistic Heavy Ion Collider (RHIC) to easily and effectively correct the second order chromaticities. We propose a method with 4 knobs corresponding to 4 pairs of chromatic sextupole families to online correct the second order chromaticities. Numerical simulation justifies this method, showing that this method reduces the unbalance in the correction strengths of sextupole families and avoids the reversal of sextupole polarities. Therefore, this method yields larger dynamic apertures for the proposed RHIC 2009 100GeV polarized proton run lattices.

43 PARTICLE ACCELERATORS↗

Review of Data from Shock Physics Experiments SPE-1, SPE-2 and SPE-3: Data Corrections and Phenomenology Analysis

The NNSA is conducting a series of high explosive (HE) tests – the Source Physics Experiments – at the National Nuclear Security Site (NNSS). These experiments are intended to investigate the generation of geophysical signals from controlled sources. These signals will aid in the development of physics-based models to aid in the discrimination of signals emitted from these and other possible sources, such as earthquakes and clandestine nuclear events. The SPE events include an array of accelerometers near to the source intended to provide measurements of the strong ground motion, or “near field,” regime. LANL performed an extensive review of the near field measurements from the first two events (SPE-1 and SPE-2) in this series. This review revealed that the near field gauges likely rotated during installation, causing measurement uncertainty. 2 This conclusion led to the installation of new gauges for the third experiment, SPE-3, utilizing new physical design and improved installation practices to achieve better quality control on their orientation. A subsequent analysis of SPE-3 data confirmed that rotations occurred and provided the basis for corrections to those data where the amount of rotation could be credibly determined. The corrected data supports a more confident analysis of the entire near field data set. This report summarizes the data errors and provides results of the analysis of the corrected dataset.

42 ENGINEERING↗

2012 Groundwater Monitoring Report Central Nevada Test Area, Subsurface Corrective Action Unit 443

The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was monitoring with institutional controls. Annual sampling and hydraulic head monitoring are conducted as part of the subsurface corrective action strategy. The site is currently in the fourth year of the 5-year proof-of-concept period that is intended to validate the compliance boundary. Analytical results from the 2012 monitoring are consistent with those of previous years. Tritium remains at levels below the laboratory minimum detectable concentration in all wells in the monitoring network. Samples collected from reentry well UC-1-P-2SR, which is not in the monitoring network but was sampled as part of supplemental activities conducted during the 2012 monitoring, indicate concentrations of tritium that are consistent with previous sampling results. This well was drilled into the chimney shortly after the detonation, and water levels continue to rise, demonstrating the very low permeability of the volcanic rocks. Water level data from new wells MV-4 and MV-5 and recompleted well HTH-1RC indicate that hydraulic heads are still recovering from installation and testing. Data from wells MV-4 and MV-5 also indicate that head levels have not yet recovered from the 2011 sampling event during which several thousand gallons of water were purged. It has been recommended that a low-flow sampling method be adopted for these wells to allow head levels to recover to steady-state conditions. Despite the lack of steady-state groundwater conditions, hydraulic head data collected from alluvial wells installed in 2009 continue to support the conceptual model that the southeast-bounding graben fault acts as a barrier to groundwater flow at the site.

54 ENVIRONMENTAL SCIENCES↗

2010 Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

This report presents the 2010 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Subsurface Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of CNTA was transferred from the DOE Office of Environmental Management to LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order entered into by DOE, the U.S. Department of Defense, and the State of Nevada. The corrective action strategy for the site includes proof-of-concept monitoring in support of site closure. This report summarizes investigation activities associated with CAU 443 that were conducted at the site from December 2009 through December 2010. It also represents the second year of the enhanced monitoring network and the 5-year proof-of-concept monitoring period that is intended to validate the compliance boundary

54 ENVIRONMENTAL SCIENCES↗