Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compaction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Laminated Permanent Magnets Enable Compact Magnetic Components in Current-Source Converters

Magnetic components have become one of the primary barriers to high power density converters, especially to current-source converters (CSCs). In CSCs, the inductors/transformers have a predominantly dc flux to store energy, which can be offset by standard permanent magnets (PMs). However, eddy currents in standard PMs induce significant losses and thermal stress for medium-frequency applications. This article proposes using laminated PMs to offset the dc flux while reducing eddy currents, leading to significant reductions in the size, cost, and losses of inductors/transformers. Furthermore, the laminated PMs’ optimal location, orientation, and distribution are investigated to generalize this approach for maximum benefits. Here, three-dimensional finite-element analysis simulation and hardware experiments are presented to validate the effectiveness of the proposed approach in a medium-frequency transformer (MFT) for CSCs. Compared with standard PMs, the proposed use of laminated PMs reduces aggregate core-plus-PM losses by 85% in experiments, and thus, relaxes the MFT thermal design. Finally, the proposed approach is experimentally validated in a 40 kVA flyback-type MFT for a soft-switching solid-state transformer. Compared to the traditional design without any PMs, the proposed design increases the saturation current by 46% while inducing only 5% more losses, leading to significant savings in magnetics cost and size.

30 DIRECT ENERGY CONVERSION↗

A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

This paper presents the design of a single-phase, single-stage line impedance stabilization network (LISN) for medium-voltage (MV) applications. More than 1 kV rated widebandgap (WBG) power semiconductor switches are increasingly utilized in new, emerging power electronics energy systems to improve power density and efficiency. However, due to inherently fast-switching speeds, WBG switch modules emit considerable electromagnetic interference (EMI) (e.g., common mode (CM) or differential mode (DM)). State-of-the-art offers standardized LISN solutions to validate and certify the new energy system for electromagnetic compatibility (EMC). However, most are for low voltage applications (i.e., < 1 kV). MV LISNs (i.e., > 1 kV) are rare until recently and literature does not provide sufficient guidelines for designing and characterizing such devices. It has been a critical challenge for many scientists and engineers to reliably certify the emerging MV energy systems (e.g., electric ships and aircraft). This paper addresses such a technology gap. Specifically, a CISPR 16-1-2 compliant 50Ω/50μH LISN with 1.5kV, 75A and 30MHz measurement capability has been proposed. Detailed performance study versus non-linear parasitic parameters variations in MV inductors and capacitors have been done. Based on new understandings, novel techniques to intuitively mitigate unwanted parasitic have been proposed to develop the proposed LISN successfully. Thorough characterization of important LISN parameters are presented and factors influencing them are analyzed. A rigorous analysis, experimental tests, and in-depth comparisons over state-of-the-art have been made to validate the effectiveness. This is done through the state-of-the-art 300kVA MV EMI testbed.

42 ENGINEERING↗

A Compact Gas Liquid Separator for the Spallation Neutron Source Mercury Process Loop

Upgrades at the spallation neutron source (SNS) accelerator at Oak Ridge National Laboratory are underway to double its proton beam power from 1.4 to 2.8 MW. About 2 MW will go to the current first station while the rest will go to the future Second Target Station. The increase of beam power to the first target station is especially challenging for its mercury target. When the short proton beam hits the target, strong pressure waves are generated, causing cavitation erosion and challenging stresses for the target's weld regions. SNS has successfully operated reliably at 1.4 MW by mitigating the pressure wave with the injection of small Helium bubbles into the mercury. To operate reliably at 2 MW, more gas will be injected into mercury to mitigate the pressure wave further. However, the mercury process loop was not originally designed for gas injection, and the accumulation of gas in the pipes is a concern. Due to space constraints, a custom gas liquid separator (GLS) was designed to fit a 90-deg horizontal elbow space in the SNS mercury loop. Simulations and experiments were performed, and a successful design was developed that has the desired efficiency while keeping the pressure losses acceptable.

42 ENGINEERING↗

A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO 2 ) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO 2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO 2 flows within pin arrays. The design includes integrated sCO 2 headers located within the MS flow, allowing for a counterflow design of the PHE. The sCO 2 headers are configured to enable uniform flow distribution into each sCO 2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on additively manufactured (AM) 316 stainless steel sub-scale specimens. An experimentally validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flowrate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m 3 (including sCO 2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. As a result, the impact of design and AM machine parameters on the cost of the PHE are assessed.

14 SOLAR ENERGY↗

Compact mid-infrared dual-comb spectrometer for outdoor spectroscopy

This manuscript describes the design of a robust, mid-infrared dual-comb spectrometer operating in the 3.1-µm to 4-µm spectral window for future field applications. The design represents an improvement in system size, power consumption, and robustness relative to previous work while also providing a high spectral signal-to-noise ratio. We demonstrate a system quality factor of 2×10 6 and 30 hours of continuous operation over a 120-meter outdoor air path.

Ycas, Gabriel↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

ERL-Based Compact X-Ray FEL

We propose to develop an energy-recovery-linac (ERL)-based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

Design of a shipping fixture for a compact cryomodule hermetic assembly

In support of the development of a conduction-cooled 915MHz superconducting radio frequency (SRF) cryomodule, this study highlights the design of a shipping fixture for transporting the hermetic assembly 4500 km from Jefferson Lab to General Atomics in San Diego, California. The hermetic assembly consists of a 2-cell 915 MHz SRF cavity, a coaxial fundamental power coupler and warm-to-cold transition beam tubes. The two-part shipping assembly consists of an inner frame, providing direct mounting of the components, and an outer frame mounted to the ground transport vehicle. The inner frame is then connected to the outer frame by way of wire-rope isolators. Accelerometer data from ground transportation of previous projects at Jefferson Lab provides the baseline for the expected frequency and magnitude of vibrational and shock events during transit. Modal analyses were carried out in ANSYS on the inner frame assembly and critical components to identify an appropriate wire-rope isolator configuration such that peak loads are mitigated and the incurred frequencies do not correspond with the fundamental modes of the structures.

Accelerator Physics↗

Compact, Achromatic Non-scaling FFAG Accelerator for HEP, Commercial and Medical Applications (CRADA FRA-2008-0005 Final Report)

Proton and light-ion accelerators have many research and medical applications, but the current state of technology in accelerators severely limits their widespread use: (1) synchrotrons have an intrinsic low duty cycle and become quite large for light ions; and (2) cyclotrons do not have energy variability and require complex superconducting magnets for high energy. A new concept in non-scaling Fixed-Field Alternating-Gradient (FFAGs) has been invented that incorporates both the energy variability of the synchrotron and the high duty cycle of the cyclotron. The concept uses normal-conducting, combined-function magnets that apply only constant (dipole) and linear-gradient (quadrupole) fields to stabilize the accelerator. This project will develop an optimized design for a new non-scaling and cost-effective innovation in FFAG accelerators. The accelerator design will have optics that can stably accelerate protons to 250 MeV (or higher) and carbon ions to =200 MeV, an energy considered ideal for radiation therapy. Phase I will optimize, fully simulate, and demonstrate the feasibility of this accelerator. Commercial Applications and other Benefits as described by the awardee: The fixed-field acceleration concept should eliminate some of the most pronounced technical difficulties, expense, maintenance, and required expertise faced in conventional proton and light-ion accelerators. In addition to the application for high energy physics, these accelerators should have application in cancer treatment, radiopharmaceuticals, and medical isotope production, and materials science.

43 PARTICLE ACCELERATORS↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗