Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alpha”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Optical Alignment of the Chromospheric Lyman-Alpha SpectroPolarimeter using Sophisticated Methods to Minimize Activities under Vacuum

The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The in- strument main scientific goal is to achieve polarization measurement of the Lyman-alpha line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. For this purpose, the optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly- pro les. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-alpha is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We will explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We will then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.

CLASP↗

Clasp/SJ Observation of Time Variations of Lyman-Alpha Emissions in a Solar Active Region

The Chromospheric Lyman-alpha SpectroPolarimeter (CLASP) is a sounding rocket experiment launched on September 3, 2015 to investigate the solar chromosphere, and the slit-jaw (SJ) optical system took Lyα images with the high time cadence of 0.6 s. By the CLASP/SJ observation, many time variations in the solar chromosphere with the time scale of <1 minute were discovered (see the poster by Kubo et al., Pa-13). We focused on an active region and investigated the short (<30 s) time variations and relation to the coronal structure observed by SDO/AIA. We compared the Ly(alpha) time variations at footpoints of coronal magnetic fields observed by AIA 211 Å (approx.2 MK) and AIA 171 Å (0.6 MK), and non-loop regions. As the result, we found the <30 s Ly(alpha) time variations had more in the footpoint regions. On the other hand, the <30 s time variations had no dependency on the temperature of the loop.

CLASP↗

Dynamics of Planets Orbiting in the Alpha Centauri AB Stellar System

The Alpha Centauri system contains the Solar System's closest stellar neighbors. If an earth-like planet is present in the system, it could in principle be detected using a small space-based telescope. As Alpha Centauri is billions of years old, planets are only expected to be found in regions where their orbits are long-lived. We evaluate the extent of the regions within the Alpha Centauri AB system where small planets are able to orbit for billion-year timescales, as well as how closely-spaced planetary orbits can be within those regions in which individual planets can survive. Individual planets on nearly circular, coplanar orbits can survive throughout the habitable zones of both stars. However, perturbations from the companion star imply that the spacing of such planets in multi-planet systems must be significantly larger than the spacing of similar systems orbiting single stars in order to be long-lived. Because the binary companion induces a forced eccentricity upon the orbits of planets in orbit around either star, appropriately-phased circumstellar orbits with small initial eccentricities are stable to slightly larger initial semi-major axes than are initially circular orbits. Small initial eccentricities have a much larger effect on how closely planetary orbits can be spaced. Our results are of special interest as they can guide observers designing instrumentation and search strategies to attempt to discover planets orbiting the nearest sun-like stars. Results remain significantly higher than for planets orbiting single stars.

Lissauer, Jack J.↗

The development of novel inhibitors of tumor necrosis factor-alpha production based on substituted [5,5]-bicyclic pyrozolones

Novel substituted [5,5]-bicyclic pyrzazolones are presented as inhibitors of tumor necrosis factor-{alpha} (TNF-{alpha}) production. Many of these compounds show low nanomolar activity against lipopolysaccaride (LPS)-induced TNF-{alpha} production in THP-1 cells. This class of molecules was co-crystallized with mutated p38, and several analogs showed good oral bioavailability in the rat. Oral activity of these compounds in the rat iodoacetate model for osteoarthritis is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Assembly and Structure of alpha-helical Peptide Films on Hydrophobic Fluorocarbon Surfaces

The structure, orientation, and formation of amphiphilic {alpha}-helix model peptide films on fluorocarbon surfaces has been monitored with sum frequency generation (SFG) vibrational spectroscopy, near-edge x-ray absorption fine structure (NEXAFS) spectroscopy, and x-ray photoelectron spectroscopy (XPS). The {alpha}-helix peptide is a 14-mer of hydrophilic lysine and hydrophobic leucine residues with a hydrophobic periodicity of 3.5. This periodicity yields a rigid amphiphilic peptide with leucine and lysine side chains located on opposite sides. XPS composition analysis confirms the formation of a peptide film that covers about 75% of the surface. NEXAFS data are consistent with chemically intact adsorption of the peptides. A weak linear dichroism of the amide {pi}* is likely due to the broad distribution of amide bond orientations inherent to the {alpha}-helical secondary structure. SFG spectra exhibit strong peaks near 2865 and 2935 cm{sup -1} related to aligned leucine side chains interacting with the hydrophobic surface. Water modes near 3200 and 3400 cm{sup -1} indicate ordering of water molecules in the adsorbed-peptide fluorocarbon surface interfacial region. Amide I peaks observed near 1655 cm{sup -1} confirm that the secondary structure is preserved in the adsorbed peptide. A kinetic study of the film formation process using XPS and SFG showed rapid adsorption of the peptides followed by a longer assembly process. Peptide SFG spectra taken at the air-buffer interface showed features related to well-ordered peptide films. Moving samples through the buffer surface led to the transfer of ordered peptide films onto the substrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of (n,alpha) Reaction for Rare-earth Elements in the MeV Neutron Energy Region

Cross sections and forward/backward ratios in the laboratory reference system were measured for {sup 143}Nd(n, {alpha}){sup 140}Ce at 4.0, 5.0, and 6.0 MeV, {sup 147}Sm(n, {alpha}){sup 144}Nd at 5.0 and 6.0 MeV, and {sup 149}Sm(n, {alpha}){sup 146}Nd at 6.0 MeV. A twin gridded ionization chamber and large-area back-to-back {sup 143}Nd{sub 2}O{sub 3} and {sup 147,149}Sm{sub 2}O{sub 3} samples were employed. Experiments were performed at the 4.5 MV Van de Graaff of Peking University, China. Fast neutrons were produced through the D(d, n){sup 3}He reaction by using a deuterium gas target. A small {sup 238}U fission chamber was employed for absolute neutron flux determination and a BF{sub 3} long counter was used as neutron flux monitor. Present experimental data are compared with previous measurements, evaluations, and model calculations.

43 PARTICLE ACCELERATORS↗

Measurements of the CKM Angle Alpha at BaBar

The authors present improved measurements of the branching fractions and CP-asymmetries fin the B{sup 0} {yields} {pi}{sup +}{pi}{sup -}, B{sup 0} {yields} {pi}{sup 0}{pi}{sup 0}, and B{sup +} {yields} {rho}{sup +}{rho}{sup 0} decays, which impact the determination of {alpha}. The combined branching fractions of B {yields} K{sub 1}(1270){pi} and B {yields} K{sub 1}(1400){pi} decays are measured for the first time and allow a novel determination of {alpha} in the B{sup 0} {yields} {alpha}{sub 1}(1260){sup {+-}}{pi}{sup {-+}} decay channel. These measurements are performed using the final dataset collected by the BaBar detector at the PEP-II B-factory. The primary goal of the experiments based at the B factories is to test the Cabibbo-Kobayashi-Maskawa (CKM) picture of CP violation in the standard model of electroweak interactions. This can be achieved by measuring the angles and sides of the Unitarity Triangle in a redundant way.

Experiment-HEP,HEPEX↗

Special Form Testing of Sealed Source Encapsulation for High-Alpha-Activity Actinide Materials

In the United States all transportation of radioactive material is regulated by the U.S. Department of Transportation (DOT). Beginning in 2008 a new type of sealed-source encapsulation package was developed and tested by Oak Ridge National Laboratory (ORNL). These packages contain high-alpha-activity actinides and are regulated and transported in accordance with the requirements for DOT Class 7 hazardous material. The DOT provides specific regulations pertaining to special form encapsulation designs. The special form designation indicates that the encapsulated radioactive contents have a very low probability of dispersion even when subjected to significant structural events. The special form designs have been shown to simplify the delivery, transport, acceptance, and receipt processes. It is intended for these sealed-source encapsulations to be shipped to various facilities making it very advantageous for them to be certified as special form. To this end, DOT Certificates of Competent Authority (CoCAs) have been sought for the design suitable for containing high-alpha-activity actinide materials. This design consists of the high-alpha-activity material encapsulated within a triangular zirconia canister, referred to as a ZipCan, tile that is then enclosed by a spherical shell. The spherical shell design, with ZipCan tile inside, was tested for compliance with the special form regulations found in 49 CFR 173.469. The spherical enclosure was subjected to 9-m impact, 1 m percussion, and 10-minute thermal tests at the Packaging Evaluation Facility located at the National Transportation Research Center in Knoxville, TN USA and operated by ORNL. Before and after each test, the test units were subjected to a helium leak check and a bubble test. The ZipCan tiles and core were also subjected to the tests required for ISO 2919:2012(E), including a Class IV impact test and heat test and subsequently subjected to helium leakage rate tests [49 CFR 173.469(a)(4)(i)]. The impact-tile test unit contained a nonradioactive surrogate; however, the thermal test unit contained a radioactive source. This paper describes the regulatory special form tests and presents detailed impact and leak test results that demonstrate that the sealed source encapsulation designs satisfy the regulatory tests.

Martinez, Oscar A↗

Fourier Analysis of the Multilevel QD Method with {alpha}-Approximation For Time-Dependent Radiative Transfer Problems

Thermal radiation transfer (TRT) problems describe interaction of photon radiation with matter. They are defined by the time-dependent radiative transfer (RT) equation for the specific intensity I coupled with the energy balance (EB) equation. This class of problems is characterised by high dimensionality, multiple scales and strong nonlinearity. In this paper we analyze the multilevel quasi-diffusion (QD) method for solving TRT problems. This is a nonlinear method of moments with exact closures. The QD method enables one to reduce dimensionality of the original radiative transfer problem. It is formulated by a nonlinear system of equations consisting of (i) the high-order RT (HORT) equation for the intensity of photon radiation and (ii) low-order equations for the angular and energy moments of the intensity. The nonlinear closures are formulated by means of stable factors. The low-order problem brings the radiative transfer model to the level of multi-physics equations. The multilevel QD (MLQD) method possesses attractive features for efficient multi-physics coupling. To calculate the high-order RT solution we apply the {alpha}-approximation which assumes that the intensity changes exponentially in time over a time step. The {alpha}-approximation leads to the steady-state RT equation with a modified opacity and enables one to avoid storing the high-dimensional solution from the previous time step. The rate of change is evaluated by the solution of the time-dependent low-order QD (LOQD) equations for moments. We note that the HORT equation in the {alpha}-approximation contains an extra nonlinear term. It affects the iterative behaviour of the MLQD method. The obtained computational results indicated that the rate of convergence is slower compared to the rate when the time-dependent HORT is used to calculate the intensity. In this paper we perform an iterative stability analysis of the MLQD method in a discretized form and analyze convergence of outer (transport) iterations on a time step. We consider multigroup TRT problems in 1D slab geometry. The fully implicit scheme is used to discretize equations in time. The HORT equation is approximated with the method of step characteristics. A finite volume method is applied for spatial discretization of multigroup LOQD equations. The grey (one-group) LOQD equations are algebraically consistent with the multigroup LOQD equations. To perform Fourier analysis a model TRT problem in an infinite homogeneous medium is considered. The system of nonlinear equations of the MLQD method is linearized near an equilibrium solution at some given temperature. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-alpha Operation of the Iota Storage Ring

Operation with ultra-low momentum-compaction factor (alpha) is a desirable capability for many storage rings and synchrotron radiation sources. For example, low-alpha lattices are commonly used to produce picosecond bunches for the generation of coherent THz radiation and are the basis of a number of conceptual designs for EUV generation via steady-state microbunching (SSMB). Achieving ultra-low alpha requires not only a high-level of stability in the linear optics but also flexible control of higher-order compaction terms. Operation with lower momentum-compaction lattices has recently been investigated at the IOTA storage ring at Fermilab. A procedure for lowering the ring compaction using the linear optics along with compensations from the higher-order magnets was developed with the aid of a model, and an experimental technique for measuring the momentum compaction was developed. The lowest momentum compaction achieved during the available run-time was $3.4\times10^{-4}$, around 15 times lower than previously operated. These feasibility studies ensure an improved experimental understanding of the IOTA optics and potentially will enable new research programs at the facility.

43 PARTICLE ACCELERATORS↗

In Vitro Cytotoxicity of Low-Dose-Rate Radioimmunotherapy by the Alpha-Emitting Radioimmunoconjugate Thorium-227-DOTA-Rituximab

Purpose: To determine whether the low-dose-rate alpha-particle-emitting radioimmunoconjugate {sup 227}Th-1,4,7,10-p-isothiocyanato-benzyl-tetraazacyclododecane-1,4,7, 10-tetraacetic acid (DOTA)-rituximab can be used to inactivate lymphoma cells growing as single cells and small colonies. Methods and Materials: CD20-positive lymphoma cell lines were treated with {sup 227}Th-DOTA-rituximab for 1-5 weeks. To simulate the in vivo situation with continuous but decreasing supply of radioimmunoconjugates from the blood pool, the cells were not washed after incubation with {sup 227}Th-DOTA-rituximab, but half of the medium was replaced with fresh medium, and cell concentration and cell-bound activity were determined every other day after start of incubation. A microdosimetric model was established to estimate the average number of hits in the nucleus for different localizations of activity. Results: There was a specific targeted effect on cell growth of the {sup 227}Th-DOTA-rituximab treatment. Although the cells were not washed after incubation with {sup 227}Th-DOTA-rituximab, the average contribution of activity in the medium to the mean dose was only 6%, whereas the average contribution from activity on the cells' own surface was 78%. The mean dose rates after incubation with 800 Bq/mL {sup 227}Th-DOTA-rituximab varied from 0.01 to 0.03 cGy/min. The average delay in growing from 10{sup 5} to 10{sup 7} cells/mL was 15 days when the cells were treated with a mean absorbed radiation dose of 2 Gy alpha-particle radiation from {sup 227}Th-DOTA-rituximab, whereas it was 11 days when the cells were irradiated with 6 Gy of X-radiation. The relative biologic effect of the treatment was estimated to be 2.9-3.4. Conclusions: The low-dose-rate radioimmunoconjugate {sup 227}Th-DOTA-rituximab is suitable for inactivation of single lymphoma cells and small colonies of lymphoma cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-field alpha spectrometry system for uranium enrichment verification of uranium hexafluoride

A portable In-Field Alpha Spectrometry (IFAS) system was developed to support on-site uranium enrichment determination for samples taken at facilities working with gaseous UF 6 . It consists of a modified commercial alpha spectrometer, a vacuum pump, a laptop computer, and associated connectors and cables. The IFAS uses specially designed Single-Use Destructive Assay (SUDA) samplers to capture gaseous UF 6 and convert and store it as UO 2 F 2 in a thin-film zeolite. To examine the quantitative performance of the IFAS system a large number of replicate SUDA samples was acquired for natural uranium (NU, 0.72 wt%, 23 samples), low enriched uranium 1 (LEU1, 2.33 wt% 235 U, 10 samples), and low enriched uranium 2 (LEU2, 4.62 wt% 235 U, 10 samples). The standard deviation (SD) values for uranium enrichment determination with the IFAS for NU, LEU1, and LEU2, in 20-hour assays, were 0.037 wt% 235 U, 0.063 wt% 235 U, and 0.072 wt% 235 U, respectively. In addition, a separate analysis suggests that comparable SD values can be achieved in less time, approximately 8-10 hours. For context, these SD values are well below the International Atomic Energy Agency’s International Target Values for the determination of uranium enrichment in non-destructive assay measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy of {sup 16}O Using {alpha}+{sup 12}C Resonant Scattering in Inverse Kinematics

A measurement of the {alpha}({sup 12}C,{alpha}){sup 12}C reaction has been performed using resonant scattering with a gas target. Beam energies of 46, 51, 56 and 63 MeV were used to populate resonances in the excitation energy range of 11.6 to 22.9 MeV in {sup 16}O. The angular distributions of the elastic scattering were measured at zero degrees using an array of segmented silicon strip detectors with a minimum range of 0 deg. to 30 deg. in the centre of mass. The spins of 8 resonances between 14.1 and 18.5 MeV were obtained, confirming spin assignments made using elastic scattering in normal kinematics. An R-matrix analysis of the data was performed which indicates that the present understanding of {sup 16}O in this region is good, but not complete.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of ion cascade energies through resolution degradation of alpha particle microcalorimeters

Atomic cascades caused by ions impinging on bulk materials have remained of interest to the scientific community since their discovery by Goldstein in 1902. While considerable effort has been spent describing and, more recently, simulating these cascades, tools that can study individual events are lacking and several aspects of cascade behavior remain poorly known. These aspects include the material energies that determine cascade magnitude and the variation between cascades produced by monoenergetic ions. We have recently developed an alpha particle detector with a thermodynamic resolution near 100 eV full-width-at-half-maximum (FWHM) and an achieved resolution of 1.06 keV FWHM for 5.3 MeV particles. The detector relies on the absorption of particles by a bulk material and a thermal change in a superconducting thermometer. The achieved resolution of this detector provides the highest resolving power of any energy dispersive technique and a factor of 8 improvement over semiconductor detectors. The exquisite resolution can be directly applied to improved measurements of fundamental nuclear decays and nuclear forensics. In addition, we propose that the discrepancy between the thermodynamic and achieved resolution is due to fluctuations in lattice damage caused by ion-induced cascades in the absorber. Hence, this new detector is capable of measuring the kinetic energy converted to lattice damage in individual atomic cascades. This capability allows new measurements of cascade dynamics; for example, we find that the ubiquitous modeling program, SRIM, significantly underestimates the lattice damage caused in bulk tin by 5.3 MeV alpha particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon Diffusion Measurement in Polyethylene based on Alpha Detection

We present a method to measure the diffusion of Radon in solid materials based on the alpha decay of the radon daughter products. In contrast to usual diffusion measurements which detect the radon that penetrates a thin barrier, we let the radon diffuse into the material and then measure the alpha decays of the radon daughter products in the material. We applied this method to regular and ultra high molecular weight poly ethylene and find diffusion lengths of order of mm as expected. However, the preliminary analysis shows significant differences between two different approaches we have chosen. These differences may be explained by the different experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alpha-particle capture reactions in inverse kinematics relevant to p-process nucleosynthesis

The first feasibility study of an {alpha}-particle capture reaction in inverse kinematics at energies relevant to the p process was performed at the Wien Filter of the LISE spectrometer at GANIL. Hereby, the {sup 4}He({sup 78}Kr,{gamma}){sup 82}Sr reaction was investigated using as target an {sup 4}He-implanted thin Al foil. The analysis of the data has shown that the determination of ({alpha},{gamma}) reaction cross sections at rather low energies around 2 MeV/u in inverse kinematics is indeed feasible regarding the high rejection rate of the primary beam, which in the present work was better than a factor of 10{sup 9}. However, the expected position of the recoils of interest was completely masked by particles of currently unknown origin that could hardly be attributed to scattering of the primary beam. The most probable explanation for the origin of these 'pollutants' could be microscopic dust particles of 10 {mu}m diameter and less, that are extremely difficult to avoid in standard experimental conditions. Hence, the use of a gas-jet target instead of a solid one is compulsory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel 4{pi} Detection System for the Measurement of the {sup 6}Li(n,{alpha}){sup 3}H Reaction Cross Section

A dedicated one-dimensional Time Projection Chamber (1D-TPC) was designed and produced at IRMM to determine the {sup 6}Li(n,{alpha}){sup 3}H cross section in the 0.4-2.8 MeV energy range, aiming at 5% accuracy. The basic TPC components were a twin gridded ionisation chamber (GIC) with interwired electrodes and fast digitisation of the anode and cathode signals. The energy of both reaction products emitted from a thin {sup 6}LiF sample at the common TPC cathode was measured. A Kr(97%)CO{sub 2}(3%) mixture was used as the detector gas at a pressure up to 3.5 bar. A {sup 238}U sample mounted on the cathode of an ionisation chamber without grid was used as the neutron flux monitor. Special care was taken to reduce the experimental sources of uncertainty. The beam-monitor {sup 238}U sample was characterised at IRMM by low-geometry {alpha}-counting with an accuracy of 0.1%. A {sup 6}Li sample was produced at IRMM by vacuum evaporation of {sup 6}LiF onto transparent aluminium backing. The number of {sup 6}Li atoms will be measured via Thermal Neutron Depth Profiling with an expected accuracy of 2% with respect to an IRMM Standard Reference Material. First test measurements were performed using a monoenergetic neutron beam produced by the T(p,n){sup 3}He reaction at the IRMM 7 MV Van de Graaff accelerator. The experimental method and preliminary results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{alpha}-particle optical potentials for nuclear astrophysics (NA) and nuclear technology (NT)

The high precision of recent measurements for low-energy {alpha}-particle elastic-scattering as well as induced-reaction data makes possible the understanding of actual limits and possible improvement of the global optical model potentials parameters. Involvement of recent optical potentials for reliable description of both the elastic scattering and emission of {alpha}-particles, of equal interest for nuclear astrophysics (NA) and nuclear technology (NT) for fusion devices, is discussed in the present work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗