SEARCH · Engineering Papers
Results for “Value Engineering”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
An engineering prototype of a late stage ionization cooling cell for a muon collider
Achieving the low emittances necessary for a muon collider requires ionization cooling. Much of that cooling occurs in compact cooling cells where superconducting coils and conventional RF cavities are closely interleaved [1]. The real challenges for these cooling cells reside in their engineering challenges: high field solenoids, RF cavities, and absorbers, often designed near technological limits, placed in close proximity to each other. We thus propose to build a prototype ionization cooling cell to demonstrate the capability of constructing an ionization cooling channel reaching the lowest emittances and to provide engineering input for the design of such beamlines. The magnets and cavities will be powered at their design values, and an absorber will be included along with a mechanism for heating the absorber similarly to how a beam would.
Requirements Document for the Redesign of the DIM-based Diagnostics Transport and Handling System at the National Ignition Facility (NIF)
The National Ignition Facility (NIF, Figure 1) is the world’s leading user research facility for inertial confinement fusion. Diagnostic instruments that collect data from the experiment shots are transported around the facility using a series of disjointed, suboptimal transport and handling (T&H) subsystems that compromise user efficiency and ergonomics. Significant time savings and improvements to the diagnostic exchange process could be realized by designing a new transport and handling system that minimizes the hand-offs between T&H subsystems, reduces operator hassle and ergonomic strain, and improves the long-term maintainability of the system. In contrast to the current system – which employs several manually-operated carts and containers to transport the diagnostic, dock it to its destination, and install it – the new diagnostic transporter integrates the contamination container with the transport cart and provides a dynamic range of adjustability to interface with its destination. This single transporter has the requisite maneuverability, height adjustability, and fine adjustment capabilities without any rigging transactions to support contaminated diagnostic transport and handling at the alignment station and Equatorial and Polar DIMs. A remote-controlled user interface device allows operators a more hands-off experience that reduces ergonomic strain and improves safety. Assuming the cost is not prohibitive, diagnostic storage will be accomplished by simply stowing the transporter in its lowest position in the designated area of NIF. This concept for a new diagnostic transport and handling system would be better aligned with the core values of NIF: safety, quality, and reliability.
Capture of Uranium Particles By Filtration: Effects of Filter Material and Air Humidity
Filtration of airborne particles is a standard technique for removal of radiological particles from the effluent of a nuclear reactor. The effects of humidity on filter performance and uranium particles are however less understood. We have conducted experimental runs in the Environmental Experimental Chamber (EEC) located at ORNL to study the capture of uranyl fluoride particles in supports of NNSA missions. Two filter types, one of Minimum Efficiency Reporting Value (MERV)-9 and the other of MERV-10 American Society of Heating, Refrigerating and Air-Conditioning Engineering) ASHRAE rating, were used in the investigations under two humidity conditions [15% and 65% Relative Humidity (Rh)]. Both MERV9 and MERV10 filters failed to capture uranyl fluoride particles that were smaller than 100 nm. The penetration efficiencies for both filter types were very high, greater than 80%, for particles from 10 to 100 nm. As particles became larger and wetter, the capturing efficiencies of both types of filter improved. Slightly greater than 50% of particles from 1 to 10 μm still escaped the capture by the MERV9 filters. However, MERV10 filters were able to capture higher than 50% of particles in the size range of 1 to 2 μm indicating it is likely to meet ASHRAE requirements. Overall, the capture efficiency of a filter is highly dependent on uranyl fluoride particle size, which humidity plays a major role. These two filter types simply are unable to capture particles smaller than 1 μm. A filter that has a higher ASHRAE rating like the HEPA filter has to be used to capture sub-micron particles. Questions on how uranyl fluoride behave in a condition higher than 65% Rh remain, because the particles could deliquescent at the higher humidity condition. That would complete change the size, shape, and surface properties of the uranyl fluoride particles which could lead to completely different filter performance and filtration dynamics. Furthermore, how high humidity affects filters of all MERV ratings remain unclear. Other filter characteristics such as surface charge could also be affected by high humidity condition and need to be investigated.
Calculation of Friction Factors in Heat Pipes Using CFD in Support of the Sockeye Code
A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, Sockeye is being developed as a heat pipe simulation capability. To support the development of Sockeye, individual phenomena must be tested. This work focuses on applying a CFD model to evaluate friction factors for use in Sockeye. A CFD model has been developed in Nek5000 which simulates each component fluid, i.e. sodium liquid and vapor, independently and captures the effects of the wick on friction factor. The model tests the effect of the wick permeability and the thickness of the wick occupied by each fluid component. The thickness of the wick occupied by each component can be directly related to the local vapor volume fraction from the Sockeye heat pipe model. Results from the CFD model indicate that friction factor in the liquid flow decreases with increasing wick permeability, while the friction factor in the vapor flow increases with increasing wick permeability. In the liquid, this is likely a direct result of the increased cross sectional area available for the flow. For the vapor, this is explained as the wick acting like a rough wall, while the increased area has only a negligible impact. Results for the tests of the thickness of the wick occupied by each fluid showed a thresholding behavior for both liquid and vapor. When the thickness of the wick occupied by each fluid was increased, it increased the effect of the wick, but only up to a certain point. Once a certain thickness was reached, the friction factors remained constant. When the fluid occupied only a very small fraction of the wick, friction factors returned to nominal values.
Business Case Analysis for Artificial Intelligence-Large Language Model Technology Integration
AI-assisted processes are expected to enhance operational efficiency and improve decision-making, supporting the long-term economic viability of nuclear power plants. However, detailed business analyses of AI-generated cost savings are rarely performed. Given the recent industry interest in Large Language Model (LLM), the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program has conducted a comprehensive business case analysis of LLM Artificial Intelligence (AI) implementation in nuclear plant engineering workflows. The research employed three complementary business case approaches to evaluate impact of an LLM, using three representative engineering processes as use-cases: Boric Acid Corrosion (BAC) Evaluations, Maintenance Rule Evaluations, and 10 CFR 50.59 Screenings. Through detailed workload analyses and structured interviews, the study quantified significant efficiency improvements ranging from 11% to 59% across these processes. The research further considers how these efficiency gains could translate into tangible reliability improvements through enhanced engineering capacity. Analysis of historical plant trip data indicates that enabling engineers to focus on proactive reliability activities could provide substantial financial benefits through avoided outages, potentially generating greater value than the direct efficiency improvements alone. By documenting successful applications, implementation challenges, and strategic opportunities, this research provides nuclear utilities with a practical framework for evaluating the value of AI technology to support long-term operations through advanced digital technologies.
Planar LTCC transformers for high voltage flyback converters: Part II.
This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.
Vibration responses of test structure no. 1 during the Edwards Air Force Base phase of the national sonic boom program
In order to evaluate reaction of people to sonic booms of varying overpressures and time durations, a series of closely controlled and systematic flight test studies were conducted in the vicinity of Edwards AFB, California, from June 3 to June 23, 1966. The dynamic responses of several building structures were measured as a part of these studies, and the measurements made in a one-story residence structure (Edwards test structure No. 1) are presented. Sample acceleration and strain recordings are presented from F-104, B-58, and XB-70 sonic-boom exposures, along with tabulations of the maximum acceleration and strain values measured for each one of about 140 flight tests. These data are compared with similar measurements for engine noise exposures of the building during simulated landing approaches and takeoffs of KC-135 aircraft.
Vibration Responses of Test Structure No. 2 During the Edward Air Force Base Phase of the National Sonic Boom Program
In order to evaluate reaction of people to sonic booms of varying overpressures and time durations, a series of closely controlled and systematic flight tests/studies were conducted from June 3 to June 23, 1966. The dynamic responses of several building structures were measured, with emphasis on a two-story residence structure. Sample acceleration and strain recordings from F-104, B-58, and XB-70 sonic boom exposures are included, along with tabulations of the maximum acceleration and strain values measured for each one of about 140 flight tests. These data are compared with similar measurements for engine noise exposures of the building during simulated landing approaches and takeoffs of KC-135 aircraft.
A leading edge heating array and a flat surface heating array - operation, maintenance and repair manual
A general description of the leading edge/flat surface heating array is presented along with its components, assembly instructions, installation instructions, operation procedures, maintenance instructions, repair procedures, schematics, spare parts lists, engineering drawings of the array, and functional acceptance test log sheets. The proper replacement of components, correct torque values, step-by-step maintenance instructions, and pretest checkouts are described.
Wind tunnel investigation of a large-scale upper surface blown-flap model having four engines
Investigations were conducted in the Ames 40- by 80-Foot Wind Tunnel to determine the aerodynamic characteristics of a large-scale subsonic jet transport model with an upper surface blown flap system. The model had a 25 deg swept wing of aspect ratio 7.28 and four turbofan engines. The lift of the flap system was augmented by turning the turbofan exhaust over the Coanda surface. Results were obtained for several flap deflections with several wing leading-edge configurations at jet momentum coefficients from 0 to 4.0. Three-component longitudinal data are presented with four engines operating. In addition, longitudinal and lateral data are presented with an engine out. The maximum lift and stall angle of the four engine model were lower than those obtained with a two engine model that was previously investigated. The addition of the outboard nacelles had an adverse effect on these values. Efforts to improve these values were successful. A maximum lift of 8.8 at an angle-of-attack of 27 deg was obtained with a jet thrust coefficient of 2 for the landing flap configuration.
Correlations for determining thermodynamic properties of hydrogen-helium gas mixtures at temperatures from 7,000 to 35,000 K
Simple relations for determining the enthalpy and temperature of hydrogen-helium gas mixtures were developed for hydrogen volumetric compositions from 1.0 to 0.7. These relations are expressed as a function of pressure and density and are valid for a range of temperatures from 7,000 to 35,000 K and pressures from 0.10 to 3.14 MPa. The proportionality constant and exponents in the correlation equations were determined for each gas composition by applying a linear least squares curve fit to a large number of thermodynamic calculations obtained from a detailed computer code. Although these simple relations yielded thermodynamic properties suitable for many engineering applications, their accuracy was improved significantly by evaluating the proportionality constants at postshock conditions and correlating these values as a function of the gas composition and the product of freestream velocity and shock angle. The resulting equations for the proportionality constants in terms of velocity and gas composition and the corresponding simple realtions for enthalpy and temperature were incorporated into a flow field computational scheme. Comparison was good between the thermodynamic properties determined from these relations and those obtained by using a detailed computer code to determine the properties. Thus, an appreciable savings in computer time was realized with no significant loss in accuracy.
Biothermal simulation of scuba divers
A biothermal model of the immersed man is presented and validated. Comparisons are made between analytic and experimental values of temperature-vs-time profiles for neck-immersed seminude and wet-suited subjects. An engineering example is presented to demonstrate how the model may be used to evaluate proposed life-support system designs.
Thermodynamic analysis of turbulent combustion in a spark ignition engine. Experimental evidence
A method independent of physical modeling assumptions is presented to analyze high speed flame photography and cylinder pressure measurements from a transparent piston spark ignition research engine. The method involves defining characteristic quantities of the phenomena of flame propagation and combustion, and estimating their values from the experimental information. Using only the pressure information, the mass fraction curves are examined. An empirical burning law is presented which simulates such curves. Statistical data for the characteristics delay and burning angles which show that cycle to cycle fractional variations are of the same order of magnitude for both angles are discussed. The enflamed and burnt mass fractions are compared as are the rates of entrainment and burning.
Fuel system design concepts for broad property fuels
The results of a study assessing the impact of using jet fuel with relaxed specification properties on an aircraft fuel system are given. The study objectives were to identify credible values for specific fuel properties which might be relaxed, to evolve advanced fuel system designs for airframe and engines which would permit use of the specified relaxed properties fuels, and to evaluate performance of the candidate advanced fuel systems and the relaxed property fuels in a typical transport aircraft. The study used, as a baseline, the fuel system incorporated in the Lockheed Tristar. This aircraft is powered by three RB.211-524 Rolls-Royce engines and incorporates a Pratt and Whitney ST6C-421 auxiliary power unit for engine starting and inflight emergency electrical power. The fuel property limits examined are compared with commercial Jet A kerosene and the NASA RFP fuel properties. A screening of these properties established that a higher freezing point and a lower thermal stability would impact fuel system design more significantly than any of the other property changes. Three candidate fuel systems which combine the ability to operate with fuels having both a high freeze point and a low thermal stability are described. All candidates employ bleed air to melt fuel freeze-out prior to starting the APU or an inoperable engine. The effects of incorporating these systems on aircraft weight and engine specific fuel consumption are given.
Engineering flowfield method with angle-of-attack applications
An approximate inviscid flowfield method has been extended to include heat-transfer predictions using a technique to account for variable-entropy edge conditions. The engineering code computes the flowfield over hyperboloids, ellipsoids, paraboloids, and sphere cones at 0 deg angle of attack (AOA). For angle-of-attack applications, an approximation to sphere-cone streamline-spreading effects on the heat transfer along the windward and leeward rays and an empirical circumferential heating technique have been incorporated also in the method. The present engineering calculations yield good comparisons with existing pressure and heating data over sphere cones even at high incidence values with the restriction that the sonic-line location remain on the spherical cap.
Combustion characteristics of gas turbine alternative fuels
An experimental investigation was conducted to obtain combustion performance values for specific heavyend, synthetic hydrocarbon fuels. A flame tube combustor modified to duplicate an advanced gas turbine engine combustor was used for the tests. Each fuel was tested at steady-state operating conditions over a range of mass flow rates, fuel-to-air mass ratio, and inlet air temperatures. The combustion pressure, as well as the hardware, were kept nearly constant over the program test phase. Test results were obtained in regards to geometric temperature pattern factors as a function of combustor wall temperatures, the combustion gas temperature, and the combustion emissions, both as affected by the mass flow rate and fuel-to-air ratio. The synthetic fuels were reacted in the combustor such that for most tests their performance was as good, if not better, than the baseline gasoline or diesel fuel tests. The only detrimental effects were that at high inlet air temperature conditions, fuel decomposition occurred in the fuel atomizing nozzle passages resulting in blockage. And the nitrogen oxide emissions were above EPA limits at low flow rate and high operating temperature conditions.
Thermal analysis of thermal barrier coatings in a high heat flux environment
Gas temperatures and pressures were measured around the second test position in the H2/O2 rocket engine at NASA-Lewis. Measured gas temperatures generally varied from 1210 to 1390 C. Measured pressures were in good agreement with other studies for throat tubes in a square chamber rocket engine. Heat transfer coefficients were measured at 90 and 180 degrees from the stagnation point and resulted in values of 27.5 and 8.5 kW/sq m C, respectively. A thermal model was developed to predict temperatures in bare and coated tubes and rods. Agreement between measured and predicted temperatures below the surface of a bare Mar-M 246 tube was very good for most of the heat up and cool down period. Predicted temperatures were significantly below measured temperatures for the coated tubes. A thermal model to simulate heat transfer to the leading edge of an HPFTP blade was developed and showed that TBCs can significantly dampen the thermal transient which occurs in the HPFTP during the startup of the SSME.