Lymphopenia Association With Gross Tumor Volume and Lung V5 and Its Effects on Non-Small Cell Lung Cancer Patient Outcomes

Purpose: Radiation therapy (RT) can both suppress and stimulate the immune system. We sought to investigate the mechanisms underlying radiation-induced lymphopenia and its associations with patient outcomes in non-small cell lung cancer (NSCLC). Methods and Materials: Subjects consisted of 711 patients who had received definitive RT for NSCLC. A lymphocyte nadir was calculated as the minimum lymphocyte value measured during definitive RT. Associations between gross tumor volumes (GTVs) and lung dose-volume histogram (DVH) parameters with lymphocyte nadirs were assessed with Spearman correlation coefficients. Relationships between lymphocyte nadirs with overall survival (OS) and event free survival (EFS) were evaluated with Kaplan-Meier analysis and compared with log-rank test results. Multivariate regressions were conducted with linear and Cox regression analyses. All variables were analyzed as continuous if possible. Results: Larger GTVs were correlated with lower lymphocyte nadirs regardless of concurrent chemotherapy receipt (with concurrent: r = −0.26, P<.0001; without: r = −0.48, P<.0001). Analyses of lung DVH parameters revealed significant correlations at lower doses (lung V5-V10: P<.0001) that incrementally decreased and became nonsignificant at higher doses (lung V60-V70: P>.05). Of note, no significant associations were detected between GTV and lung DVH parameters with total leukocyte, neutrophil, or monocyte nadirs during RT or with lymphocyte count prior to RT. Multivariate analysis revealed larger GTV (P<.0001), receipt of concurrent chemotherapy (P<.0001), twice-daily radiation fractionation (P=.02), and stage III disease (P=.05) to be associated with lower lymphocyte nadirs. On univariate analysis, patients with higher lymphocyte nadirs exhibited significantly improved OS (hazard ratio [HR] = 0.51 per 10{sup 3} lymphocytes/μL, P=.01) and EFS (HR = 0.46 per 10{sup 3} lymphocytes/μL, P<.0001). These differences held on multivariate analyses, controlling for common disease and treatment characteristics including GTV. Conclusions: Lower lymphocyte nadirs during definitive RT were associated with larger GTVs and worse patient outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sparing Healthy Tissue and Increasing Tumor Dose Using Bayesian Modeling of Geometric Uncertainties for Planning Target Volume Personalization

Objective: To develop a mathematical tool that can update a patient's planning target volume (PTV) partway through a course of radiation therapy to more precisely target the tumor for the remainder of treatment and reduce dose to surrounding healthy tissue. Methods and Materials: Daily on-board imaging was used to collect large datasets of displacements for patients undergoing external beam radiation therapy for solid tumors. Bayesian statistical modeling of these geometric uncertainties was used to optimally trade off between displacement data collected from previously treated patients and the progressively accumulating data from a patient currently partway through treatment, to optimally predict future displacements for that patient. These predictions were used to update the PTV position and margin width for the remainder of treatment, such that the clinical target volume (CTV) was more precisely targeted. Results: Software simulation of dose to CTV and normal tissue for 2 real prostate displacement datasets consisting of 146 and 290 patients treated with a minimum of 30 fractions each showed that re-evaluating the PTV position and margin width after 8 treatment fractions reduced healthy tissue dose by 19% and 17%, respectively, while maintaining CTV dose. Conclusion: Incorporating patient-specific displacement patterns from early in a course of treatment allows PTV adaptation for the remainder of treatment. This substantially reduces the dose to healthy tissues and thus can reduce radiation therapy–induced toxicities, improving patient outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dose distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for Reducing Normal Tissue Complication Probabilities in Oropharyngeal Cancer: Dose Reduction or Planning Target Volume Elimination

Purpose: Strategies to reduce the toxicities of head and neck radiation (ie, dysphagia [difficulty swallowing] and xerostomia [dry mouth]) are currently underway. However, the predicted benefit of dose and planning target volume (PTV) reduction strategies is unknown. The purpose of the present study was to compare the normal tissue complication probabilities (NTCP) for swallowing and salivary structures in standard plans (70 Gy [P70]), dose-reduced plans (60 Gy [P60]), and plans eliminating the PTV margin. Methods and Materials: A total of 38 oropharyngeal cancer (OPC) plans were analyzed. Standard organ-sparing volumetric modulated arc therapy plans (P70) were created and then modified by eliminating the PTVs and treating the clinical tumor volumes (CTVs) only (C70) or maintaining the PTV but reducing the dose to 60 Gy (P60). NTCP dose models for the pharyngeal constrictors, glottis/supraglottic larynx, parotid glands (PGs), and submandibular glands (SMGs) were analyzed. The minimal clinically important benefit was defined as a mean change in NTCP of >5%. The P70 NTCP thresholds and overlap percentages of the organs at risk with the PTVs (56-59 Gy, vPTV{sub 56}) were evaluated to identify the predictors for NTCP improvement. Results: With the P60 plans, only the ipsilateral PG (iPG) benefited (23.9% vs 16.2%; P<.01). With the C70 plans, only the iPG (23.9% vs 17.5%; P<.01) and contralateral SMG (cSMG) (NTCP 32.1% vs 22.9%; P<.01) benefited. An iPG NTCP threshold of 20% and 30% predicted NTCP benefits for the P60 and C70 plans, respectively (P<.001). A cSMG NTCP threshold of 30% predicted for an NTCP benefit with the C70 plans (P<.001). Furthermore, for the iPG, a vPTV{sub 56} >13% predicted benefit with P60 (P<.001) and C70 (P=.002). For the cSMG, a vPTV{sub 56} >22% predicted benefit with C70 (P<.01). Conclusions: PTV elimination and dose-reduction lowered the NTCP of the iPG, and PTV elimination lowered the NTCP of the cSMG. NTCP thresholds and the percentage of overlap of the PTV with organs at risk can predict which patients will benefit and inform future clinical trial design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe tumors; higher interfraction amplitude variability indicated tumors in contact with mediastinal structures, although adhesion to parietal pleura did not necessarily reduce tumor motion amplitudes. The most variable lung tumors were metastatic lesions in women.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume of Lytic Vertebral Body Metastatic Disease Quantified Using Computed Tomography–Based Image Segmentation Predicts Fracture Risk After Spine Stereotactic Body Radiation Therapy

Purpose: To determine a threshold of vertebral body (VB) osteolytic or osteoblastic tumor involvement that would predict vertebral compression fracture (VCF) risk after stereotactic body radiation therapy (SBRT), using volumetric image-segmentation software. Methods and Materials: A computational semiautomated skeletal metastasis segmentation process refined in our laboratory was applied to the pretreatment planning CT scan of 100 vertebral segments in 55 patients treated with spine SBRT. Each VB was segmented and the percentage of lytic and/or blastic disease by volume determined. Results: The cumulative incidence of VCF at 3 and 12 months was 14.1% and 17.3%, respectively. The median follow-up was 7.3 months (range, 0.6-67.6 months). In all, 56% of segments were determined lytic, 23% blastic, and 21% mixed, according to clinical radiologic determination. Within these 3 clinical cohorts, the segmentation-determined mean percentages of lytic and blastic tumor were 8.9% and 6.0%, 0.2% and 26.9%, and 3.4% and 15.8% by volume, respectively. On the basis of the entire cohort (n=100), a significant association was observed for the osteolytic percentage measures and the occurrence of VCF (P<.001) but not for the osteoblastic measures. The most significant lytic disease threshold was observed at ≥11.6% (odds ratio 37.4, 95% confidence interval 9.4-148.9). On multivariable analysis, ≥11.6% lytic disease (P<.001), baseline VCF (P<.001), and SBRT with ≥20 Gy per fraction (P=.014) were predictive. Conclusions: Pretreatment lytic VB disease volumetric measures, independent of the blastic component, predict for SBRT-induced VCF. Larger-scale trials evaluating our software are planned to validate the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Academic Facility Type and Case Volume on Survival in Patients Undergoing Curative Radiation Therapy for Muscle-Invasive Bladder Cancer

Bladder-preserving curative radiation therapy (RT) has been established as an excellent treatment option for select patients with muscle-invasive bladder cancer (MIBC). However, some clinicians have concerns that good outcomes are only achievable at high-volume facilities (HVFs) and academic centers (ACs), questioning successful reproducibility of curative RT at smaller centers. This study sought to determine whether treatment at ACs or HVFs was associated with better overall survival (OS) than treatment at nonacademic centers or lower-volume facilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Phase 2 Study of Radiation Therapy Dose and Volume De-escalation for Elective Neck Treatment of Oropharyngeal and Laryngeal Cancer

The required elective nodal dose and volumes for head and neck intensity modulated radiation therapy have largely been extrapolated from conventional radiation therapy fields. In this prospective, dual-center, phase 2 study, we investigated the efficacy and tolerability of reduced elective nodal volume and dose in oropharyngeal and laryngeal squamous cell carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating the impact of micropore volume of aminosilica functionalized SBA-15 on catalytic activity for amine-catalyzed reactions

Mesoporous materials such as SBA-15 are used in many applications since the materials are robust and have tunable properties. Whereas these materials are thought to be ideal, the materials are complex with the common synthesis methods producing materials that contain micropores. This work will investigate the impact of micropores on catalytic activity of aminosilica materials. For comparison, materials are formed using a standard method that produces materials with micropores (REG-SBA-15) and using a modified method that produces materials with negligible micropore volume (NMP-SBA-15). After grafting the calcined support with an aminosilane (either (N-methyl amino propyl) trimethoxy silane (denoted as 2°Am) or (N,N-diethyl-3-amino propyl) trimethoxy silane (3°Am)), catalytic testing experiments reveal that NMP-SBA-15 functionalized materials are more active than REG-SBA-15 functionalized materials for a range of reactions. The reactions include (a) glucose isomerization where amines interacting with surface silanols limit catalytic activity and (b) aldol and Knoevenagel chemistry where amine-silanol interactions increase the reaction rate. For aldol chemistry, the observed difference in rate is further investigated using site quantification experiments. Interestingly, the results reveal that three types of sites exist for each material, including sites that are (1) highly active, (2) intermediate active, and (3) inactive. Additionally, NMR experiments indicate that amines immobilized on REG-SBA-15 supports are less mobile than amines on NMP-SBA-15. For REG-SBA-15, the materials are found to have aminosilanes that have limited mobility and the largest fraction of inactive sites, which suggests that the inactive catalytic sites are in the micropores. Overall, the design of highly active catalytic materials can be achieved using materials that have limited micropore volumes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled numerical approach combining finite volume and lattice Boltzmann methods for multi-scale multi-physicochemical processes

A coupled (hybrid) simulation strategy spatially combining the finite volume method (FVM) and the lattice Boltzmann method (LBM), called CFVLBM, is developed to simulate coupled multi-scale multi-physicochemical processes. In the CFVLBM, computational domain of multi-scale problems is divided into two sub-domains, i.e., an open, free fluid region and a region filled with porous materials. The FVM and LBM are used for these two regions, respectively, with information exchanged at the interface between the two sub-domains. A general reconstruction operator (RO) is proposed to derive the distribution functions in the LBM from the corresponding macro scalar, the governing equation of which obeys the convection–diffusion equation. The CFVLBM and the RO are validated in several typical physicochemical problems and then are applied to simulate complex multi-scale coupled fluid flow, heat transfer, mass transport, and chemical reaction in a wall-coated micro reactor. The maximum ratio of the grid size between the FVM and LBM regions is explored and discussed. -- Highlights: •A coupled simulation strategy for simulating multi-scale phenomena is developed. •Finite volume method and lattice Boltzmann method are coupled. •A reconstruction operator is derived to transfer information at the sub-domains interface. •Coupled multi-scale multiple physicochemical processes in micro reactor are simulated. •Techniques to save computational resources and improve the efficiency are discussed.

97 MATHEMATICS AND COMPUTING↗

Compositional modeling in porous media using constant volume flash and flux computation without the need for phase identification

The paper deals with the numerical solution of a compositional model describing compressible two-phase flow of a mixture composed of several components in porous media with species transfer between the phases. The mathematical model is formulated by means of the extended Darcy's laws for all phases, components continuity equations, constitutive relations, and appropriate initial and boundary conditions. The splitting of components among the phases is described using a new formulation of the local thermodynamic equilibrium which uses volume, temperature, and moles as specification variables. The problem is solved numerically using a combination of the mixed-hybrid finite element method for the total flux discretization and the finite volume method for the discretization of transport equations. A new approach to numerical flux approximation is proposed, which does not require the phase identification and determination of correspondence between the phases on adjacent elements. The time discretization is carried out by the backward Euler method. The resulting large system of nonlinear algebraic equations is solved by the Newton–Raphson iterative method. We provide eight examples of different complexity to show reliability and robustness of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of confined magnetohydrodynamic flows with Dirichlet boundary conditions using a pseudo-spectral method with volume penalization

A volume penalization approach to simulate magnetohydrodynamic (MHD) flows in confined domains is presented. Here the incompressible visco-resistive MHD equations are solved using parallel pseudo-spectral solvers in Cartesian geometries. The volume penalization technique is an immersed boundary method which is characterized by a high flexibility for the geometry of the considered flow. In the present case, it allows to use other than periodic boundary conditions in a Fourier pseudo-spectral approach. The numerical method is validated and its convergence is assessed for two- and three-dimensional hydrodynamic (HD) and MHD flows, by comparing the numerical results with results from literature and analytical solutions. The test cases considered are two-dimensional Taylor–Couette flow, the z-pinch configuration, three dimensional Orszag–Tang flow, Ohmic-decay in a periodic cylinder, three-dimensional Taylor–Couette flow with and without axial magnetic field and three-dimensional Hartmann-instabilities in a cylinder with an imposed helical magnetic field. Finally, we present a magnetohydrodynamic flow simulation in toroidal geometry with non-symmetric cross section and imposing a helical magnetic field to illustrate the potential of the method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compression of tokamak boundary plasma simulation data using a maximum volume algorithm for matrix skeleton decomposition

This report demonstrates satisfactory data compression of SOLPS-ITER simulation output ranging from 2D fields, 1D profiles, and 0D scalar variables with a novel matrix decomposition approach. The singular value decomposition (SVD) scales poorly for large matrix sizes and is unsuited to the application on high dimensional data common to fusion plasma physics simulation. In this work, we employ the columns-submatrix-rows (CUR) matrix factorization technique in order to compute a low-rank approximation up to two orders of magnitude faster than the SVD, but within a nominal L2-norm relative error of ε = 10 –2 . In addition, the CUR approach maintains the original format of the data, in its extracted columns and rows, allowing for interpretable data storage at the original resolution of the simulation. We utilize an iterative algorithm to compute the CUR decomposition of simulation output by maximizing the volume, or linearly independent information content, of a low-rank submatrix contained within the data. Experiments over $\textit{n} × \textit{n}$ randomized test matrices with embedded rank-deficient features show that this maximum volume implementation of CUR matrix approximation has reduced asymptotic computational complexity on the order of n compared to the SVD, which scales approximately as $n^3$. These results show that the CUR technique can be used to effectively select time step snapshots (columns) of over 140 SOLPS-ITER output variables and the associated discretized coordinate timeseries (rows) allowing for reconstruction of the complete simulation dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Daily Rectal Dose-volume Histogram Variation in Prostate Intensity-modulated Radiation Therapy: Is It Clinically Significant in the Era of Image Guidance?

Because of the steep dose gradient associated with dose-escalated intensity-modulated radiation therapy, interfraction motion and variation in rectal volume may result in the rectum receiving a larger dose than predicted at treatment planning. This study aims to quantify the variation in daily rectal dose-volume histograms (DVHs) from the treatment plan and to discuss the potential clinical significance of this variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method for measurement of TRISO kernel and layer volumes by X-ray computed tomography

Layer dimensions are key parameters for as-fabricated tristructural-isotropic (TRISO) particle fuel as well as for post-irradiation examination of particle performance. Layer thicknesses are typically measured by optical microscopy of the particle cross section near mid-plane, while layer volumes are estimated with serial sectioning and microscopy. This method for measuring layer volumes is limited due to the resolution limit imposed by slice thickness and the effect of the polishing process on delicate irradiated particle microstructures. In this study, image processing software has been developed to segregate the three-dimensional (3D) TRISO particle images provided by x-ray computed tomography (XCT) into high-resolution volumetric data for the kernel, all particle layers, and any internal voids introduced during irradiation. These data can be used to analyze key in-reactor behaviors of TRISO particles such as kernel swelling or buffer shrinkage, which are important inputs for fuel performance modeling.

36 MATERIALS SCIENCE↗

Electronic origins of the giant volume collapse in the pyrite mineral MnS 2

The pyrite mineral MnS 2 was recently shown to undergo a giant pressure-induced volume collapse at 12 GPa, via a disordered intermediate phase. The high pressure arsenopyrite phase is stabilised by metal-metal bonding, a mechanism now shown to be ubiquitous for Mn 2+ chalcogenides. Here we report a spectroscopic investigation of this transition up to pressures of 22 GPa. Using XANES we show that the transition does not involve a change in oxidation state, consistent with the arsenopyrite crystal structure proposed at high pressure. Notably, the XANES spectrum is almost identical in the pressure-induced disordered phase, and after crystallisation induced by laser-heating. The former is therefore a `valence bond glass', and is likely disordered due to kinetic hindrance of the phase transition. We also detect electronic changes in the compressed pyrite phase, and this is con rmed by Raman scattering which shows that the disulphide vibrations in the pyrite phase saturate before the volume collapse. Together with detailed DFT calculations, these results indicate that electronic changes precede valence bond formation between the Mn 2+ cations.

36 MATERIALS SCIENCE↗

Stereology of backscatter electron images of etched surfaces for characterization of particle size distributions and volume fractions: Estimation of imaging bias via Monte Carlo simulations

On metallic specimens in which a secondary phase has been selectively removed by a chemical etchant, the use of backscatter electron (BSE) imaging yields images that are more readily segmented with image processing algorithms than other modes of imaging in the scanning electron microscope. The contrast mechanisms in this imaging mode, however, produce a bias in the observation of particle sizes and volume fractions due to the effects of the electron interaction volume in the specimen. This stereological bias is quantified using Monte Carlo (MC) simulation of backscatter images. It is observed that the overprojection of features with centroids residing beneath the plane of polish is largely canceled out by the reduced segmentation size of features with centroids residing above the plane of polish. - Research Highlights: {yields} Backscatter imaging of selectively-etched surfaces can facilitate segmentation. {yields} Backscatter imaging of voids is simulated to estimate imaging/observation biases. {yields} The biases are quantified and incorporated into the stereological calculation. {yields} Systematic errors and imaging biases are observed to counteract one another. {yields} Results are illustrated using a bimodal gamma prime distribution in a Ni superalloy.

36 MATERIALS SCIENCE↗