Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Enhancing quantum utility: Simulating large-scale quantum spin chains on superconducting quantum computers

We present the quantum simulation of the frustrated quantum spin- 1 2 antiferromagnetic Heisenberg spin chain with competing nearest-neighbor ( J 1 ) and next-nearest-neighbor ( J 2 ) exchange interactions in the real superconducting quantum computer with qubits ranging up to 100. In particular, we implement the Hamiltonian with the next-nearest neighbor exchange interaction in conjunction with the nearest-neighbor interaction on IBM's superconducting quantum computer and carry out the time evolution of the spin chain by employing the first-order Trotterization. Furthermore, our implementation of the second-order Trotterization for the isotropic Heisenberg spin chain, involving only nearest-neighbor exchange interaction, enables precise measurement of the expectation values of staggered magnetization observable across a range of up to 100 qubits. Notably, in both cases, our approach results in a constant circuit depth in each Trotter step, independent of the number of qubits. Our demonstration of the accurate measurement of expectation values for the large-scale quantum system using superconducting quantum computers designates the quantum utility of these devices for investigating various properties of many-body quantum systems. This will be a stepping stone to achieving the quantum advantage over classical ones in simulating quantum systems before the fault tolerance quantum era. Published by the American Physical Society 2024

97 MATHEMATICS AND COMPUTING↗

Utilizing broadband X-rays in a Bragg coherent X-ray diffraction imaging experiment

A method is presented to simplify Bragg coherent X-ray diffraction imaging studies of complex heterogeneous crystalline materials with a two-stage screening/imaging process that utilizes polychromatic and monochromatic coherent X-rays and is compatible with in situ sample environments. Coherent white-beam diffraction is used to identify an individual crystal particle or grain that displays desired properties within a larger population. A three-dimensional reciprocal-space map suitable for diffraction imaging is then measured for the Bragg peak of interest using a monochromatic beam energy scan that requires no sample motion, thus simplifying in situ chamber design. This approach was demonstrated with Au nanoparticles and will enable, for example, individual grains in a polycrystalline material of specific orientation to be selected, then imaged in three dimensions while under load.

36 MATERIALS SCIENCE↗

Understanding nanoscale structural distortions in Pb(Zr 0.2 Ti 0.8 )O 3 by utilizing X-ray nanodiffraction and clustering algorithm analysis

Hard X-ray nanodiffraction provides a unique nondestructive technique to quantify local strain and structural inhomogeneities at nanometer length scales. However, sample mosaicity and phase separation can result in a complex diffraction pattern that can make it challenging to quantify nanoscale structural distortions. In this work, a k-means clustering algorithm was utilized to identify local maxima of intensity by partitioning diffraction data in a three-dimensional feature space of detector coordinates and intensity. This technique has been applied to X-ray nanodiffraction measurements of a patterned ferroelectric PbZr 0.2 Ti 0.8 O 3 sample. The analysis reveals the presence of two phases in the sample with different lattice parameters. A highly heterogeneous distribution of lattice parameters with a variation of 0.02 Å was also observed within one ferroelectric domain. This approach provides a nanoscale survey of subtle structural distortions as well as phase separation in ferroelectric domains in a patterned sample.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimal Iterative Method for Network Utility Maximization with Intertemporal Constraints

Network utility maximization (NUM) has been widely used to solve the optimal resource allocation problem in wireless network and power systems. The network planner aims to allocate generation and demand over producers and consumers such that social welfare is maximized while supply and demand are balanced, and network constraints such as branch capacity constraints are satisfied. However, when taking into account dynamics of agents, such as ramp rate constraints on power output for suppliers and impact of cumulative prior consumption on current demand for consumers, a single-period formulation is not sufficient. We propose an iterative method for the multi-period NUM with intertemporal constraints based on dual decomposition. It features a price iteration scheme that achieves optimal social welfare, and the algorithm is guaranteed to converge if proper concavity condition holds. We illustrate the iterative algorithm by power system examples. It is shown that similar to locational marginal price (LMP) in power systems, time-varying congestion prices arise when there exists binding branch constraints. Simulation results also demonstrate that there is increase in social welfare compared to a single-period formulation.

Ma, Ke↗

Power Quality Improvement Utilizing Photovoltaic Generation Connected to a Weak Grid

Microgrid research and development in the past decades have been one of the most popular topics. Similarly, the photovoltaic generation has been surging among renewable generation in the past few years, thanks to the availability, affordability, technology maturity of the PV panels and the PV inverter in the general market. Unfortunately, quite often, the PV installations are connected to weak grids and may have been considered as the culprit of poor power quality affecting other loads in particular sensitive loads connected to the same point of common coupling (PCC). This paper is intended to demystify the renewable generation, and turns the negative perception into positive revelation of the superiority of PV generation to the power quality improvement in a microgrid system. The main objective of this work is to develop a control method for the PV inverter so that the power quality at the PCC will be improved under various disturbances. The method is to control the reactive current based on utilizing the grid current to counteract the negative impact of the disturbances. The proposed control method is verified in PSIM platform. Promising results have been obtained.

14 SOLAR ENERGY↗

Architecture for Utility-Scale Multi-Chemistry Battery Energy Storage

The next generation of utility-scale energy storage will be composed of modular systems and autoconfiguring software. This is key to incorporating battery management systems (BMS) and power electronic converters (PEC) from multiple manufacturers into a cohesive single system. In this paper, an agent-based architecture which supports the integration of numerous BMSs and PECs is proposed. This architecture supports optimization and control of the entire system and can be used in many different energy storage technologies.

Smith, Mitchell↗

Impedance Characterization of Utility-Scale Renewable Energy and Storage Systems

This paper presents the impedance characterization of utility-scale wind turbines and PV/storage inverters using a multimegawatt grid simulator-based grid integration testbed. The paper describes the testbed components including a 7 MVA grid simulator, 5 MW dynamometer, medium-voltage measurement system, and a real-time control system used for automated impedance characterization of wind turbines and inverters. Different aspects of impedance measurement are discussed, including the selection of the magnitude and type of perturbation, measurement of frequency cross-coupling between sequence impedance responses, and the alignment of the reference frame for sequence impedance measurement. The paper also demonstrates high-fidelity validation of EMT simulation models from turbine manufacturers and characterization of grid-forming inverters using impedance measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Storage Sizing and Operation of an Integrated Utility-Scale PV+ESS Power Plant

Integration of an energy storage system (ESS) into a large-scale grid-connected photovoltaic (PV) power plant is highly desirable to improve performance of the system and overcome the stochastic nature of PV power generation. Algorithms to size ESS within an integrated PV and ESS ( PV+ESS) power plant, conventionally, require a large number of high-resolution samples of PV generation. These algorithms are computationally expensive. In this paper, a two-day optimization algorithm that utilizes n-step constant power output dispatch every day from the PV+ESS power plant is proposed to size the ESS. Additionally, an n-step power dispatch every day through the one-year timeframe based optimization of the size of ESS is also performed. The proposed methods are computationally cheaper and provide acceptable accuracy with respect to the conventional sizing methods. The economics identified from the proposed methods are compared with the typical day-ahead hourly dispatch-based power production from the PV+ESS power plant. This comparison has shown similar economic performance showcasing the accuracy of the proposed methods in sizing the ESS. It also shows the potential for operating PV+ESS power plant in n-step constant power generation mode.

Xia, Qian↗

Characterization of Temperature Heterogeneity in Utility-Scale Power Plant Boilers by Spatially Distributed Ultrasonic Measurements

In extreme environments, even hardened insertion sensors fail quickly. For such environments, we have developed an ultrasonic (US) method for measuring the spatial distribution of temperatures in solid materials and, specifically, across containments of extreme processes. By deploying US sensors in multiple locations, spatial heterogeneity in temperatures inside harsh environments may be characterized. In this note, we update our progress on testing the developed approach in an industrial setting and its performance in describing the temperature distribution inside a 500 MW (electrical) coalfired utility boiler of an electrical power generation plant. We use waveguides (WG) structured to contain echogenic features that produce a train of echoes in response to an excitation pulse. The time of flight between echoes encodes the information on the temperature distribution in the corresponding segment of the WG, which we reconstruct using its parametrization. Five waveguides were welded to the boiler’s heat exchange surface (waterwall) and different locations at the same boiler elevation and produced reliable US waveforms 18 months after the installation. For several weeks during the latest trial, we performed US measurements in five locations spanning half of the boiler’s 14-meter width. The measurements were acquired during regular operation, including load cycling to adjust for demand and intermittent contributions of renewable power sources, and during boiler shutdown for emergency maintenance and the subsequent restart. The interpretation of US waveforms by signal processing resulted in an accurate estimation of temperature distribution along the waveguides. We captured daily cyclical variations in demand-following load. Measurements performed in multiple locations revealed unexpected temperature variations across the boiler. We conclude that an array of developed sensors can provide responsive and spatial temperature measurements while maintaining functionality despite prolonged exposure to an extreme environment.

Walton, Kenneth↗

Light and Elevated Temperature Induced Degradation (LeTID) in a Utility-Scale Photovoltaic System

Here, we present a detailed case study of degradation in monocrystalline silicon photovoltaic modules operating in a utility-scale power plant over the course of approximately three years. We present the results of degradation analysis on arrays within the site, and find that five of the six arrays degraded faster than the best performing array, even though the arrays consist of modules of the same manufacturer and model. We also describe the results of extensive laboratory characterization of modules returned from the field, including module- and cell-level current–voltage characterization, luminescence imaging, and accelerated testing. The laboratory test results and the field performance are consistent with light and elevated temperature induced degradation (LeTID). Notably, we observe differences in back contact technology between affected and unaffected modules. This article also demonstrates a method to identify possible LeTID degradation in the field and confirm the result with laboratory testing of a small number of modules.

14 SOLAR ENERGY↗

Light- and Elevated-Temperature-Induced Degradation-Affected Silicon Cells From a Utility-Scale Photovoltaic System Characterized by Deep-Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated-temperature-induced degradation (LeTID). Samples from the affected monocrystalline silicon cells are cored and extracted from the module packaging and then laser-scribed to form 2-mm diameter isolated areas. Using deep-level transient spectroscopy, a majority-carrier, hole-trap defect with an activation energy of 0.42 eV is detected on degraded and regenerated samples. The LeTID-degraded sample, however, has a larger signal corresponding to a trap density of 1.1 x 10 13 cm -3 , which is about five times larger than the 2.1 x 10 12 cm -3 trap density of the regenerated sample. An increase in filling pulse time from 50 u s to 20 ms shows a slight decrease in activation energy from 0.42 to 0.36 eV suggesting that the defect level may consist of a band of energy states where shallower states continue to fill with long filling times. The capture rate of the defect is directly measured using an increasing series of filling pulsewidths in 15 to 125 ns range. This leads to a measured capture cross section of 5.1 x 10 -17 cm 2 , and using an approximate defect density of 10 13 cm -3 , the majority-carrier-hole lifetime related to this defect is approximately 100 u s when in the LeTID-degraded state.

charge carrier lifetime↗

Nanometer-Scale Measurement of Grid Finger Electrical Conduction Pathways to Detect Series Resistance Degradation of Utility-Scale Silicon Solar Cells

Here, we report on an electrical conduction mechanism for series resistance (Rs) degradation observed in a utility-scale photovoltaic power plant by imaging the local resistance at the Ag/Si interface of the c-Si front metallization. Scanning spreading resistance microscopy imaging with nanometer (nm) scale spatial resolution revealed that the number of point or small-area electrical contacts decreased substantially in a degraded cell compared to an unaffected cell, demonstrating the root cause of Rs degradation. The decrease in electrical contacts is likely caused by a structural change - the Ag particles in contact with the Si cell (or via a nm-thickness tunneling glass layer) aggregate into bulk Ag, and a highly resistive glass frit forms a belt shape at the Ag/Si interface. This resistive belt, with a thickness of ~1 um, blocks the current conduction from the cell emitter to the Ag grid. Our microscopy results help to unravel unambiguously the degradation mechanism and demonstrate an example of the multiscale characterization approach for understanding degradation in field-weathered PV module.

14 SOLAR ENERGY↗

Correspondence: Bill of Materials Variation and Module Degradation in Utility-Scale PV Systems

We report photovoltaic (PV) modules of the same make and model are often assembled with different bills of materials (BOMs). In this correspondence, we revisit two case studies of utility-scale silicon PV systems in which these differing BOMs were associated with faster-than-expected degradation. In one of the sites, we found that different metallization paste had been used for grid lines in some cells leading to loss of contact to the cell and severe series resistance degradation. We provide details on the observation of this mechanism at two additional sites not described in the original article. In a second case study, we found that two different types of cell had been used, and that they could be distinguished by their back contact. Cells with uniform back contacts suffered from light and elevated temperature induced degradation (LeTID), while those with local back contacts did not. We also briefly describe BOM variations observed at other sites to illustrate the extent of the challenge. Our results from both sites underscore that variations in BOM, even among modules of the same make and model can lead to reliability challenges.

14 SOLAR ENERGY↗

An Investigation on the Pollen-Induced Soiling Losses in Utility-Scale PV Plants

Here in this study, the impact of pollen as a PV soiling agent is investigated. The performance data of five utility-scale PV plants in North Carolina, USA, was collected and analyzed using two soiling extraction methods. Satellite and environmental data, including pollen counts, cropland, and vegetation, was also collected and analyzed to identify impacts to soiling losses. During the spring peak pollen season, performance losses of >15% were observed at all five sites. Partial performance recoveries following the pollen season were slow, with lack of correlation with rainfall. This means that the statistical soiling estimation methods that assume abrupt performance recovery from rain are not appropriate for pollen-impacted solar sites. When manual cleanings were performed on site the performance recovery ranged from 5% to 11% indicating persistent soiling impacts are present in this region. The results of this work provide new insights into the phenomenon of pollen deposition on PV systems, demonstrating that 1) soiling can also affect systems located in rainy locations and 2) that its effects cannot be determined using the current estimation methodologies.

14 SOLAR ENERGY↗

Utility-Scale Lithium-Ion Storage Cost Projections for Use in Capacity Expansion Models

This work presents U.S. utility-scale battery storage cost projections for use in capacity expansion models. We create battery cost projections based on a survey of literature cost projections of battery packs and balance of system costs, with a focus on lithium-ion batteries. Low, mid, and high cost trajectories are created for the overnight capital costs and the operating and maintenance costs. We then demonstrate the impact of these cost projections in the Regional Energy Deployment System (ReEDS) capacity expansion model. We find that under reference scenario conditions, lower battery costs can lead to increased penetration of variable renewable energy, with solar photovoltaics (PV) seeing the largest increase. We also find that additional storage can reduce renewable energy curtailment, although that comes at the expense of additional storage losses.

25 ENERGY STORAGE↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

Optimal Managed Fast-Charging Model for Electric Vehicle Fleets with High Utilization and Multiple Charge-Acceptance Curves

A predictive control/scheduling optimization model is proposed for managed charging of an electric vehicle (EV) fleet - under time-of-use energy and demand prices, high vehicle utilization frequency (short dwell times), multiple charge- acceptance curves (configurable charging rates), and flexible vehicle demand. This context is particularly relevant for flight schools (small electric aircraft) or other commercial facilities where an EV fleet performs multiple operating and fast-charging sessions on the same day. The proposed model performs both the operational and charging scheduling of the vehicles, which is not typically done for residential managed charging and significantly increases problem complexity. The problem is formulated as a MILP model and a case study of a small fast-charging station is presented. Results demonstrate a significant reduction in operating cost, mainly from peak shaving during high demand price periods, achieved by coordinating the operation of different vehicles, chargers and charging rates.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

An Investigation on the Pollen-Induced Soiling Losses in Utility-Scale PV Plants

Soiling, the accumulation of dust and other contaminants on the surface of photovoltaic (PV) modules, is a common factor that can negatively impact the performance of PV systems. In this study, the authors aim to analyze the impact of pollen on soiling losses in PV systems located in North Carolina, USA, particularly during the spring season. The performance data of two utility-scale PV plants was collected and analyzed using the two soiling extraction methods. Environmental data, including croplands and vegetation was also collected and analyzed to identify correlations with soiling losses. The results of the study may help improve understanding of necessary operation and maintenance activities for PV plants and provide new insights into the phenomenon of pollen deposition on PV systems.

correlation↗