Results of initial analyses of the salt (macro) batch 9 tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further results on the chemistry and other tests will be issued in the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from the interim salt disposition program macrobatch 10 tank 21 H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). This document reports characterization data on the samples of Tank 21H and fulfills the requirements of Deliverable 3 of the Technical Task Request (TTR). Further work will report the results of the Extraction-Scrub-Strip (ESS) testing (Task 5 of the TTR) using the Tank 21H material. Task 4 of the TTR (MST Strike) will not be completed for Salt Batch 10.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-Flammability of Gases Generated by Hanford Tank Waste and the Potential of Nitrogen Inerting to Eliminate Flammability Safety Concerns

Through radiolytic and thermolytic reactions, Hanford tank wastes generate and retain a variety of gases, including hydrogen, nitrous oxide, methane (and other hydrocarbons), ammonia, and nitrogen. This gas generation can be expected to continue during processing in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The generation rates in the WTP will change from those for the in-situ tank waste because of different process temperatures, different dose rates produced by in-process changes in the proportions of solid and liquid, and dilution of the waste liquid. The flammability of the generated gas that is continuously released, and of any retained gas that might be released into a vessel headspace in quantity due to a spontaneous release, depends on the concentrations not only of the fuel gases—primarily hydrogen (H2), methane, other hydrocarbons, and ammonia—but of the oxidizer nitrous oxide (N2O). As a result of high concentrations of N2O, some gas mixtures are “self-flammable” (i.e., ignition can occur when no air is present because N2O provides the only oxidizer needed). Self-flammability could potentially reduce the effectiveness of using a nitrogen (N2) purge in the headspace as a flammability control, if its effects are not accounted for. A given amount of inertant gas (N2) can accommodate only a certain amount of a generated self-flammable gas before the mixture with inertant gas becomes flammable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Report, Fall 2016: Identifying Cost Effective Tank Waste Characterization Approaches

This report documents the activities that were performed during the second year of a project undertaken to improve the cost effectiveness and timeliness of SRNL’s tank closure characterization practices. The activities performed during the first year of the project were previously reported in SRNL-STI-2015-00144. The scope of the second year activities was divided into the following three primary tasks: 1) develop a technical basis and strategy for improving the cost effectiveness and schedule of SRNL’s tank closure characterization program; 2) initiate the design and assembly of a new waste removal system for improving the throughput and reducing the personnel dose associated with extraction chromatography radiochemical separations; and 3) develop and perform feasibility testing of three alternative radiochemical separation protocols holding promise for improving high resource demand/time consuming tank closure sample analysis methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, -scrub, -strip test results from the interim salt disposition program macrobatch 10 tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solvent hold tank sample results for MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017): Quarterly Report

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017) are reported. Analyses indicate that the modifier (CS-7SB) and the extractant (MaxCalix) concentrations are at their nominal recommended levels (169,000 mg/L and 46,300 mg/L respectively). The suppressor (TiDG) level has decreased to a steady state level of 673 mg/L well above the minimum recommended level (479 mg/L). This analysis confirms the Isopar™ addition to the solvent in January 18, 2017. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). Another impurity observed in the samples was mercury. Up to 38 ± 8 micrograms of mercury per mL of solvent was detected in these samples (the average of the CV-AA and XRF methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 8 and 9 (Tank 49H) or mixing of previously undisturbed areas of high mercury concentration in Tank 49H. The gamma level (0.21E5 dpm/mL) measured in the February SHT sample was one order of magnitude lower than the gamma levels observed in the December and January SHT samples. The February gamma level is consistent with the solvent being idle (since January 10, 2017). The gamma levels observed in the December and January SHT samples were consistent with previous monthly measurements where the process operated normally. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Tank 51 Sludge Slurry Samples (HTF-51-17-44/ HTF-51-17-48) in Support of Sludge Batch 10 Processing

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) Engineering (SRR-E) to provide sample characterization and analyses of Tank 51 sludge samples in support of Sludge Batch (SB) 10. The two Tank 51 sludge samples were sampled and delivered to SRNL in May of 2017. These two Tank 51 sludge samples were combined into one composite sample and analyzed for corrosion controls analytes, select radionuclides, chemical elements, density and weight percent total solids and aluminum hydroxides (gibbsite and boehmite) by x-ray diffraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystalline Silicotitanate (CST) Ion Exchange Media Performance Evaluations in SRS Average Supernate Simulant and Tank 10H Waste Solution to Support TCCR

Savannah River Remediation (SRR) is deploying an “at-tank” ion exchange process to remove radioactive cesium from waste supernate which is referred to as the Tank Closure Cesium Removal (TCCR) system utilizing Crystalline Silicotitanate (CST) media. After being loaded with cesium, but before flushed and dried and sent to Interim Safe Storage (ISS), it is anticipated that the TCCR ion exchange columns will be taken off-line (stagnant) with the CST media still immersed in supernate. The currently designed columns include no active cooling system during processing (although no rmal process fluid flow through the column during operations provides significant cooling) or during off-line conditions and temperature increases are expected in the stagnant, loaded, and liquid-filled columns due to decay heat from the radionuclides absorbed to the CST. As a result, modification of the Tank 10H supernate composition has been considered through the addition of either NaOH or KOH reagents to decrease cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Temperature Aluminum Dissolution (LTAD) Real Waste Testing of the November 2017 Tank 51 Slurry Sample

Low Temperature Aluminum Dissolution (LTAD) will be performed on Tank 51 sludge prior to sending Sludge Batch 10 to the Defense Waste Processing Facility (DWPF), such that a sizable fraction of the insoluble aluminum will be dissolved and removed. During LTAD, the free hydroxide concentration and temperature of the sludge slurry are both raised, resulting in significantly increased aluminum solubility, which facilitates aluminum removal via decanting of the liquid phase. This Research and Development task will provide input information regarding the expected gas generation rates under the bounding temperature and free hydroxide conditions of the upcoming Tank 51 LTAD evolution. It will also provide information on the expected fraction of insoluble aluminum that will dissolve as a function of temperature and time, as well as the expected chemical and phys ical properties of the Tank 51 sludge slurry, prior to and following the LTAD operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Radioactive Waste Tank Inspection Program – 2017

The Department of Energy (DOE) requires that Savannah River Remediation LLC (SRR), the Liquid Waste contractor, maintain a robust and timely Structural Integrity Program for waste tanks that are leak-tight and for waste tanks that have leaked or are suspect. These requirements are promulgated in DOE Manual 435.1-1, Section II.Q.(2). A key aspect of SRR’s implementation of these requirements is its annual tank inspection program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results from The Interim Salt Disposition Program Macrobatch 11 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 11 for the Interim Salt Disposition Program (ISDP). The Salt Batch 11 characterization results were previously reported. An Extraction, Scrub, and Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the Next Generation Solvent (NGS) Blend solvent currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 117. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This cesium removal efficiency is better than the predicted value of 50.8 from a recently created D (Cs) model.

Peters, T.↗

Diesel Bulk Storage Tank, Construction

Diesel bulk storage tank based on Eagle Tanks Inc's 30,000 gal tank, adjusted to the needed capacity on a kg material/kg fuel basis. Includes security storage space. Materials include carbon and stainless steel. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=2D8104BE-2CD2-40BF-B32D-149D6C79D7D6

02 PETROLEUM↗

Gasoline Bulk Storage Tank, Construction

Gasoline bulk storage tank based on Eagle Tanks Inc's 30,000 gal tank, adjusted to the needed capacity on a kg material/kg fuel basis. Includes security storage space. Materials include carbon and stainless steel. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=A0F02BAC-884F-4742-8A23-763E05DEA857

02 PETROLEUM↗

NUCON Vapor Abatement Unit Performance on Hanford Tank Farm Chemicals of Potential Concern

This report provided the results and methods used in the NUCON Vapor Abatement Unit performance testing. The purpose of the Pacific Northwest National Laboratory (PNNL) testing was to assess the performance of the NUCON International, Inc., Vapor Abatement Unit (VAU) prototype for the reduction of Hanford Tank Farm vapors associated chemicals of potential concern (COPC). The testing was conducted in compliance with the PNNL Assessment of NUCON Vapor Abatement Unit for Single-Shell Tank (SST) Farm Off-Gas Chemicals of Potential Concern (COPCs) test plan. Performance testing started on May 4, 2018 and continued through June 13, 2018. Eleven (11) COPCs were chosen for testing out of the 61 identified COPCs. The COPCs were chosen either due to the importance of that COPC measured in Hanford high-level waste single-shell tank (SST) vapor emissions, as a surrogate to represent a class of COPC compounds, or both. Results of the performance tests are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Initial Analyses of the Salt Waste Processing Facility (SWPF) Batch 2 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Salt Waste Processing Facility (SWPF) Batch 2 for processing. This document reports the initial expedited results of the analyses of the Tank 21H qualification sample. Analysis of the Tank 21H SWPF Batch 2 sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual color. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Crucible Vitrification of CST and Simulated Hanford Tank Waste

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility for immobilization. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated by the Tank-Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18× 10 -5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream through ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of GSA2018 Flow Update, Alternative Dispersion Model, and Increased Grid Resolution on Tank Closure Performance Assessments

The F-Area Tank Farm (FTF) and H-Area Tank Farm (HTF) Performance Assessments (PAs) involve simulations of radionuclide and chemical waste migration through groundwater to exposure points. These solute transport simulations are based on a circa 2004 “GSA/PORFLOW” flow model [WSRC-TR-2004-00106]. The GSA/PORFLOW model was significantly updated in 2016-2017 [SRNL-STI-2017-00008 Rev. 1]. Impacts of the “GSA2016” flow model on the F- and H-Tank Farm PAs were assessed in SRNL-STI-2017-00445, Impacts of Updated GSA Groundwater Flow Models on the FTF, HTF and SDF PAs. Since then (2018-2019) further revisions resulted in a “GSA2018” flow model [SRNL-STI-2018-00643], which has been adopted for the 2019 Saltstone PA revision [SRR-CWDA-2019-00001 Revision A]. This study assesses the impacts of the GSA2018 flow model on the FTF and HTF PAs. Also assessed are the impacts of an alternative plume dispersion model and increased grid resolution that have been incorporated in the 2019 Saltstone PA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 37H

The Savannah River National Laboratory (SRNL) Atmospheric Technologies Group performed atmospheric dispersion modeling and analysis of mercury emissions from the H-Tank Farm - Tank 37 ventilation system exhaust to evaluate whether the Short-Term Exposure Limit (STEL) for mercury is exceeded during salt dissolution activities. This analysis was also used to establish a minimum stack height at which ambient mercury concentration would not exceed this regulatory limit. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. Results indicate that the default 10-foot stack results in ground level concentrations that significantly exceed the standards for the mercury discharge scenarios evaluated. A 35-foot stack was necessary to raise the exhaust plume centerline from Tank 37H to a height that prevents mercury exposure problems for the three discharge concentrations modeled.