Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

INTERFERENCE DETECTION IN GAUSSIAN NOISE

Interference detection in Gaussian noise is proposed. It can be applied for easy detection and editing of interference lines in radio spectral line observations. One does not need to know the position of occurrence or keep track of interference in the band. By using statistical properties of N-channel Gaussian noise it is possible to differentiate interference from normal Gaussian noise. These statistical properties are three quantities which are calculated on the subject spectrum. The first is the expected absolute maximum from the mean level across the spectrum. The second is the expected absolute difference maximum (array of adjacent differences of channel values taken across the spectrum), and the third is the expected absolute added difference maximum. For N-channel Gaussian noise, these quantities have a well-defined value. Any deviation across the spectrum that violates an upper limit formed by these expected maxima is attributed to interference. Results obtained on real data by applying this technique have been displayed.

97 MATHEMATICS AND COMPUTING↗

Evaluation of bolus electron conformal therapy compared with conventional techniques for the treatment of left chest wall postmastectomy in patients with breast cancer

Postmastectomy radiation (PMRT) lowers local-regional recurrence risk and improves survival in selected patients with breast cancer. The chest wall and lower axilla are technically challenging areas to treat with homogenous doses and normal tissue sparing. This study compares several techniques for PMRT to provide data to guide selection of optimal treatment techniques. Twenty-five consecutive left-sided patients treated postmastectomy were contoured using Radiation Therapy Oncology Group (RTOG) atlas guidelines then planned using 4 different PMRT techniques: opposed tangents with wedges (3-dimensional [3D] wedges), opposed tangents with field-in-field (FiF) modulation, 8-field intensity modulation radiotherapy (IMRT), and custom bolus electron conformal therapy (BolusECT, .decimal, Inc., Sanford, FL). Required planning target volume (PTV) coverage was held constant, and then dose homogeneity and normal tissue dose parameters were compared among the 4 techniques. BolusECT achieved clincally acceptable PTV coverage for 22 out of 25 cases. Compared with either tangential technique, IMRT and BolusECT provided the lowest heart V{sub 25} doses (3.3% ± 0.9% and 6.6% ± 3.2%, respectively with p < 0.0001). FiF had the lowest mean total lung dose (7.3 ± 1.1 Gy, with p = 0.0013), IMRT had the lowest total lung V{sub 20} (10.3% ± 1.6%, p < 0.0001), and BolusECT had the lowest mean heart dose (7.3 ± 2.0 Gy, p = 0.0002). IMRT provided the optimal dose homogeneity and normal tissue sparing compared with all other techniques for the cases in which BolusECT could not achieve acceptable PTV coverage. IMRT generally exposes contralateral breast and lung to slightly higher doses. Optimal PMRT technique depends upon patient anatomy. Patients whose maximal target volume depth is about 5.7 cm or less can be treated with BolusECT-assisted 12 or 15 MeV electron beams. At these energies, BolusECT has comparable dose-volume statistics as IMRT and lower heart V{sub 25} than opposed tangential beams. Patients with larger depths are best treated with IMRT, which provides significant advantages in both dose homogeneity and normal tissue sparing compared with all other techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Dosimetric Benefits of Intensity-Modulated Radiotherapy Combined With the Deep-Inspiration Breath-Hold Technique in Patients With Mediastinal Hodgkin's Lymphoma

Purpose: To assess the additional benefits of using the deep-inspiration breath-hold (DIBH) technique with intensity-modulated radiotherapy (IMRT) in terms of the protection of organs at risk for patients with mediastinal Hodgkin's disease. Methods and Materials: Patients with early-stage Hodgkin's lymphoma with mediastinal involvement were entered into the study. Two simulation computed tomography scans were performed for each patient: one using the free-breathing (FB) technique and the other using the DIBH technique with a dedicated spirometer. The clinical target volume, planning target volume (PTV), and organs at risk were determined on both computed tomography scans according to the guidelines of the European Organization for Research and Treatment of Cancer. In both cases, 30 Gy in 15 fractions was prescribed. The dosimetric parameters retrieved for the statistical analysis were PTV coverage, mean heart dose, mean coronary artery dose, mean lung dose, and lung V20. Results: There were no significant differences in PTV coverage between the two techniques (FB vs. DIBH). The mean doses delivered to the coronary arteries, heart, and lungs were significantly reduced by 15% to 20% using DIBH compared with FB, and the lung V20 was reduced by almost one third. The dose reduction to organs at risk was greater for masses in the upper part of the mediastinum. IMRT with DIBH was partially implemented in 1 patient. This combination will be extended to other patients in the near future. Conclusions: Radiation exposure of the coronary arteries, heart, and lungs in patients with mediastinal Hodgkin's lymphoma was greatly reduced using DIBH with IMRT. The greatest benefit was obtained for tumors in the upper part of the mediastinum. The possibility of a wider use in clinical practice is currently under investigation in our department.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The 2.4 μ m Galaxy Luminosity Function as Measured Using WISE . III. Measurement Results

The Widefield Infrared Survey Explorer (WISE) satellite surveyed the entire sky multiple times in four infrared wavelengths (3.4, 4.6, 12, and 22 μm). The unprecedented combination of coverage area and depth gives us the opportunity to measure the luminosity function (LF) of galaxies, one of the fundamental quantities in the study of them, at 2.4 μm to an unparalleled level of formal statistical accuracy in the near-infrared. The big advantage of measuring LFs at wavelengths in the window of ≈2–3.5 μm is that it correlates more closely to the total stellar mass in galaxies than others. In this paper we report on the parameters of the 2.4 μm LF of galaxies obtained from applying the spectro-luminosity-functional-based methods to datasets from the previous papers in this series using the mean and covariance of 2.4 μm normalized spectral energy distributions (SEDs) from our previous work. In terms of the single Schechter function parameters evaluated at the present epoch, the combined result is: ${\phi }_{\star }=5.8\,\pm [{0.3}_{\mathrm{stat}},{0.4}_{\mathrm{sys}}]\times {10}^{-3}\,{\mathrm{Mpc}}^{-3}$, ${L}_{\star }=6.4\pm [{0.1}_{\mathrm{stat}},{0.3}_{\mathrm{sys}}]\times {10}^{10}\,{L}_{2.4\mu {\rm{m}}\odot }$ (M$_{\star}$ = -21.67 ± [0.02 stat , 0.05 sys ] AB mag), and $α$ = -1.050 ± [0.004 stat , 0.04 sys ]. The high statistical accuracy comes from combining public redshift surveys with the wide coverage from WISE, and the unevenness in statistical accuracy is a result of our efforts to work around biases of uncertain origin that affect resolved and marginally resolved galaxies. With further refinements, the techniques applied in this work promise to advance the study of the SED of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Statistics for F-theory Standard Models

Much of the analysis of F-theory-based Standard Models boils down to computing cohomologies of line bundles on matter curves. By varying parameters one can degenerate such matter curves to singular ones, typically with many nodes, where the computation is combinatorial and straightforward. The question remains to relate the (a priori possibly smaller) value on the original curve to the singular one. In this work, we introduce some elementary techniques (pruning trees and removing interior edges) for simplifying the resulting nodal curves to a small collection of terminal ones that can be handled directly. When applied to the QSMs, these techniques yield optimal results in the sense that obtaining more precise answers would require currently unavailable information about the QSM geometries. This provides us with an opportunity to enhance the statistical bounds established in earlier research regarding the absence of vector-like exotics on the quark-doublet curve.

Bies, Martin↗

Manipulation and statistical analysis of the fluid flow of polymer semiconductor solutions during meniscus-guided coating

Recent work in structure–processing relationships of polymer semiconductors have demonstrated the versatility and control of thin-film microstructure offered by meniscusguided coating (MGC) techniques. Here, we analyze the qualitative and quantitative aspects of solution shearing, a model MGC method, using coating blades augmented with arrays of pillars. The pillars induce local regions of high strain rates—both shear and extensional—not otherwise possible with unmodified blades, and we use fluid mechanical simulations to model and study a variety of pillar spacings and densities. We then perform a statistical analysis of 130 simulation variables to find correlations with three dependent variables of interest: thin-film degree of crystallinity and transistor field-effect mobilities for charge-transport parallel (Μ para ) and perpendicular (Μ perp ) to the coating direction. Our study suggests that simple fluid mechanical models can reproduce substantive correlations between the induced fluid flow and important performance metrics, providing a methodology for optimizing blade design.

36 MATERIALS SCIENCE↗

A statistically defined anthropomorphic software breast phantom

Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm){sup 3} voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise ({beta} = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 Multiplication-Sign 3 boxcar kernel and up-sampled to (0.1 mm){sup 3} voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent {beta} from 25.6 Multiplication-Sign 25.6 mm{sup 2} regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for {beta} (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. {beta} values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism.

60 APPLIED LIFE SCIENCES↗

Studying magnetohydrodynamic turbulence with synchrotron polarization dispersion

We test a new technique for studying magnetohydrodynamic turbulence suggested by Lazarian and Pogosyan, using synthetic observations of synchrotron polarization. This paper focuses on a one-point statistics, which is termed polarization frequency analysis, that is characterized by the variance of polarized emission as a function of the square of the wavelength along a single line of sight. We adopt the ratio η of the standard deviation of the line-of-sight turbulent magnetic field to the line-of-sight mean magnetic field to depict the level of turbulence. When this ratio is large (η≫1), which characterizes a region dominated by turbulent field, or small (η≲0.2), which characterizes a region dominated by the mean field, we obtain the polarization variance 〈P{sup 2}〉∝λ{sup −2} or 〈P{sup 2}〉∝λ{sup −2−2m}, respectively. At small η, i.e., in the region dominated by the mean field, we successfully recover the turbulent spectral index from the polarization variance. We find that our simulations agree well with the theoretical prediction of Lazarian and Pogosyan. With existing and upcoming data cubes from the Low-Frequency Array for Radio Astronomy (LOFAR) and the Square Kilometer Array (SKA), this new technique can be applied to study the magnetic turbulence in the Milky Way and other galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-shot picosecond pump coherent Rayleigh scattering thermometry

A single-shot coherent Rayleigh scattering (CRS) technique capable of measurement times less than 10 ns is presented. Here, the use of a mode-locked picosecond pump laser yields repeatable electrostrictive forcing compared to previous CRS experiments using unseeded nanosecond pump pulses, which are beset by shot-to-shot variations. Quantitative measurements are achieved by dispersing the CRS signal onto an EMCCD sensor using a virtually imaged phased array and comparing the experimental spectra to an existing kinetic model with a least-squares fitting routine. Measurements are demonstrated at ambient and low-pressure (2 Torr), low-temperature (100 K) conditions where the CRS measurement is within the collisionless regime. Single-shot statistics indicated precision and accuracy within 4% at ambient conditions and within 8% at low density and temperature conditions. This single-shot CRS technique is a powerful diagnostic tool with potential for multi-parameter measurements in complex flow environments, including high-speed aerodynamic ground test facilities.

Senior, William Charles Bowman [Sandia National La↗

On the proper kinetic quadrupole CMB removal and the quadrupole anomalies

It has been pointed out recently that the quadrupole-octupole alignment in the CMB data is significantly affected by the so-called kinetic Doppler quadrupole (DQ), which is the temperature quadrupole induced by our proper motion. Assuming our velocity is the dominant contribution to the CMB dipole we have v/c=β=(1.231 ± 0.003) × 10{sup −3}, which leads to a non-negligible DQ of O(β{sup 2}). Here we stress that one should properly take into account that CMB data are usually not presented in true thermodynamic temperature, which induces a frequency dependent boost correction. The DQ must therefore be multiplied by a frequency-averaged factor, which we explicitly compute for several Planck CMB maps finding that it varies between 1.67 and 2.47. This is often neglected in the literature and turns out to cause a small but non-negligible difference in the significance levels of some quadrupole-related statistics. For instance the alignment significance in the SMICA 2013 map goes from 2.3σ to 3.3σ with the frequency dependent DQ, instead of 2.9σ ignoring the frequency dependence in the DQ. Moreover as a result of a proper DQ removal, the agreement across different map-making techniques is improved.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-calibration of photometric redshift scatter in weak-lensing surveys

Photo-z errors, especially catastrophic errors, are a major uncertainty for precision weak lensing cosmology. We find that the shear-(galaxy number) density and density-density cross correlation measurements between photo-z bins, available from the same lensing surveys, contain valuable information for self-calibration of the scattering probabilities between the true-z and photo-z bins. The self-calibration technique we propose does not rely on cosmological priors nor parameterization of the photo-z probability distribution function, and preserves all of the cosmological information available from shear-shear measurement. We estimate the calibration accuracy through the Fisher matrix formalism. We find that, for advanced lensing surveys such as the planned stage IV surveys, the rate of photo-z outliers can be determined with statistical uncertainties of 0.01-1% for z < 2 galaxies. Among the several sources of calibration error that we identify and investigate, the galaxy distribution bias is likely the most dominant systematic error, whereby photo-z outliers have different redshift distributions and/or bias than non-outliers from the same bin. This bias affects all photo-z calibration techniques based on correlation measurements. As a result, galaxy bias variations of O(0.1) produce biases in photo-z outlier rates similar to the statistical errors of our method, so this galaxy distribution bias may bias the reconstructed scatters at several-σ level, but is unlikely to completely invalidate the self-calibration technique.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Recognition Techniques for Gamma Spectroscopy

Photons, after generated from a radioactive source and before they deposit their energy in a photo detector, are subsequent to multiple scattering mechanisms. As a result, the measured energy from the photo detector is different from the energy the photon had when generated. This is known as folding of the photon energy. Moreover, statistical fluctuation inside the detector contribute to energy folding. In this work, a new method is presented for unfolding the gamma ray spectrum. The method uses a 2-dimensional representation of the measured spectrum (image) and then uses image recognition techniques, and especially differential edge detection, to generate the original spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Analysis of Step-Stress Accelerated Life Test with Exponential Distribution

In this article, we propose a general Bayesian inference approach to the step-stress accelerated life test with type II censoring. We assume that the failure times at each stress level are exponentially distributed and the test units are tested in an increasing order of stress levels. We formulate the prior distribution of the parameters of life-stress function and integrate the engineering knowledge of product failure rate and acceleration factor into the prior. The posterior distribution and the point estimates for the parameters of interest are provided. Through the Markov chain Monte Carlo technique, we demonstrate a nonconjugate prior case using an industrial example. It is shown that with the Bayesian approach, the statistical precision of parameter estimation is improved and, consequently, the required number of failures could be reduced.

14 SOLAR ENERGY↗

Surface processing and discharge-conditioning of high voltage electrodes for the Ra EDM experiment

The Ra EDM experiment uses a pair of high voltage electrodes to search for the atomic electric dipole moment of 225 Ra. We use identical, plane–parallel electrodes with a primary high gradient surface of 200 mm 2 to generate reversible DC electric fields. Our statistical sensitivity is linearly proportional to the electric field strength in the electrode gap. We adapted surface decontamination and processing techniques from accelerator physics literature to chemical polish and clean a suite of newly fabricated large-grain niobium and grade-2 titanium electrodes. Three pairs of niobium electrodes and one pair of titanium electrodes were discharge-conditioned with a custom high voltage test station at electric field strengths as high as +52.5 kV/mm and –51.5 kV/mm over electrode gap sizes ranging from 0.4 mm to 2.5 mm. One pair of large-grain niobium electrodes was discharge-conditioned and validated to operate at ±20 kV/mm with steady-state leakage current ≤ 25 pA (1σ) and a polarity-averaged 98 ± 19 discharges per hour. These electrodes were installed in the Ra EDM experimental apparatus, replacing a copper electrode pair, and were revalidated to ±20 kV/mm. Here, the niobium electrodes perform at an electric field strength 3.1 times larger than the legacy copper electrodes and are ultimately limited by the maximum output of our 30 kV bipolar power supply.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Probabilistic Model for Global EMIC Wave Activity Using Van Allen Probes Observations

Electromagnetic ion cyclotron (EMIC) waves play a key role in radiation belt dynamics through resonant interactions. However, their low occurrence probability, high variability, and spatial intermittency pose challenges for accurate modeling. In this study, we present a machine learning (ML)-based global EMIC wave model built on the entire data set from the Van Allen Probes mission. To capture the distinct statistical characteristics of wave occurrence and amplitude, the model is separated into two modules: an occurrence model trained using ML techniques, and a wave amplitude model sampled from observed probability distributions. The input parameters are limited to real-time or predictable variables to ensure practical applicability. Our model shows strong performance across the entire test set and demonstrates improved predictive capability over a baseline random occurrence model, particularly during quiet geomagnetic conditions. Evaluation during both quiet and active periods confirms the model's ability to represent the clustered and intermittent nature of EMIC wave activity. Furthermore, the model provides global estimates of wave power, enabling integration with radiation belt electron data and showing signatures consistent with wave-induced scattering. We found a good correlation between the global wave activity from the model and relativistic electron observation by Van Allen Probes, regardless of the availability of in situ wave observations. The modular structure of the model also allows for straightforward expansion for additional wave properties, such as wave frequency, which can be modeled independently. This flexible, event-sensitive approach offers a promising framework for data-driven radiation belt simulations and space weather applications.

79 ASTRONOMY AND ASTROPHYSICS↗