Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical Algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a correlation ofr = 0.92 for FGT% and r = 0.93 for |FGT|, and the automated segmentation is not statistically significantly different (p = 0.46 for FGT% and p = 0.55 for |FGT|). The bilateral correlation between left breasts and right breasts for the FGT% is 0.94, 0.92, and 0.95 for reader 1, reader 2, and the FCM-Atlas, respectively; likewise, for the |FGT|, it is 0.92, 0.92, and 0.93, respectively. For the spatial segmentation agreement, the automated algorithm achieves a DSC of 0.69 ± 0.1 when compared to reader 1 and 0.61 ± 0.1 for reader 2, respectively, while the DSC between the two readers’ manual segmentation is 0.67 ± 0.15. Additional robustness analysis shows that the segmentation performance of the authors' method is stable both with respect to selecting different cases and to varying the number of cases needed to construct the prior probability atlas. The authors' results also show that the proposed FCM-Atlas method outperforms the commonly used two-cluster FCM-alone method. The authors' method runs at ∼5 min for each 3D bilateral MR scan (56 slices) for computing the FGT% and |FGT|, compared to ∼55 min needed for manual segmentation for the same purpose. Conclusions: The authors' method achieves robust segmentation and can serve as an efficient tool for processing large clinical datasets for quantifying the fibroglandular tissue content in breast MRI. It holds a great potential to support clinical applications in the future including breast cancer risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Hybrid Monte Carlo-Deterministic Method for Global Binary Stochastic Medium Transport Problems

Global deep-penetration transport problems are difficult to solve using traditional Monte Carlo techniques. In these problems, the scalar flux distribution is desired at all points in the spatial domain (global nature), and the scalar flux typically drops by several orders of magnitude across the problem (deep-penetration nature). As a result, few particle histories may reach certain regions of the domain, producing a relatively large variance in tallies in those regions. Implicit capture (also known as survival biasing or absorption suppression) can be used to increase the efficiency of the Monte Carlo transport algorithm to some degree. A hybrid Monte Carlo-deterministic technique has previously been developed by Cooper and Larsen to reduce variance in global problems by distributing particles more evenly throughout the spatial domain. This hybrid method uses an approximate deterministic estimate of the forward scalar flux distribution to automatically generate weight windows for the Monte Carlo transport simulation, avoiding the necessity for the code user to specify the weight window parameters. In a binary stochastic medium, the material properties at a given spatial location are known only statistically. The most common approach to solving particle transport problems involving binary stochastic media is to use the atomic mix (AM) approximation in which the transport problem is solved using ensemble-averaged material properties. The most ubiquitous deterministic model developed specifically for solving binary stochastic media transport problems is the Levermore-Pomraning (L-P) model. Zimmerman and Adams proposed a Monte Carlo algorithm (Algorithm A) that solves the Levermore-Pomraning equations and another Monte Carlo algorithm (Algorithm B) that is more accurate as a result of improved local material realization modeling. Recent benchmark studies have shown that Algorithm B is often significantly more accurate than Algorithm A (and therefore the L-P model) for deep penetration problems such as examined in this paper. In this research, we investigate the application of a variant of the hybrid Monte Carlo-deterministic method proposed by Cooper and Larsen to global deep penetration problems involving binary stochastic media. To our knowledge, hybrid Monte Carlo-deterministic methods have not previously been applied to problems involving a stochastic medium. We investigate two approaches for computing the approximate deterministic estimate of the forward scalar flux distribution used to automatically generate the weight windows. The first approach uses the atomic mix approximation to the binary stochastic medium transport problem and a low-order discrete ordinates angular approximation. The second approach uses the Levermore-Pomraning model for the binary stochastic medium transport problem and a low-order discrete ordinates angular approximation. In both cases, we use Monte Carlo Algorithm B with weight windows automatically generated from the approximate forward scalar flux distribution to obtain the solution of the transport problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlative feature analysis on FFDM

Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer-aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual-stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two-step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, the distance feature yielded an area under the ROC curve (AUC) of 0.81{+-}0.02 with leave-one-out (by physical lesion) evaluation, and the feature metric subset, which included distance, gradient texture, and ROI-based correlation, yielded an AUC of 0.87{+-}0.02. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Selection and Assessment of Phenomenological Models of Tumor Growth

We address general approaches to the rational selection and validation of mathematical and computational models of tumor growth using methods of Bayesian inference. The model classes are derived from a general diffuse-interface, continuum mixture theory and focus on mass conservation of mixtures with up to four species. Synthetic data are generated using higher-order base models. We discuss general approaches to model calibration, validation, plausibility, and selection based on Bayesian-based methods, information theory, and maximum information entropy. We also address computational issues and provide numerical experiments based on Markov chain Monte Carlo algorithms and high performance computing implementations.

59 BASIC BIOLOGICAL SCIENCES↗

Parallel algorithms for hyperdynamics and local hyperdynamics

Hyperdynamics (HD) is a method for accelerating the timescale of standard molecular dynamics (MD). It can be used for simulations of systems with an energy potential landscape that is a collection of basins, separated by barriers, where transitions between basins are infrequent. HD enables the system to escape from a basin more quickly while enabling a statistically accurate renormalization of the simulation time, thus effectively boosting the timescale of the simulation. In [Kim, Perez, Voter, J Chem Phys, 139:144110, 2013)1, a local version of HD was formulated, which exploits the intrinsic locality characteristic typical of most systems to mitigate the poor scaling properties of standard HD as the system size is increased. In this paper, we discuss how both HD and local HD can be formulated to run efficiently in parallel. We have implemented these ideas in the LAMMPS MD code, which means HD can be used with any interatomic potential LAMMPS supports. Together, these parallel methods allow simulations of any size to achieve the time acceleration offered by HD (which can be orders of magnitude), at a cost 3-5x that of standard MD. As examples, we performed two simulations of a million-atom system to model the diffusion and clustering of Pt adatoms on a large patch of Pt(100) surface for 80 and 160 μs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment and Minimization of Contralateral Breast Dose for Conventional and Intensity Modulated Breast Radiotherapy

Breast radiotherapy is associated with an increased risk of contralateral breast cancer (CBC) in women under age 45 at the time of treatment. This risk increases with increasing absorbed dose to the contralateral breast. The use of intensity modulated radiotherapy (IMRT) is expected to substantially reduce the dose to the contralateral breast by eliminating scattered radiation from physical beam modifiers. The absorbed dose to the contralateral breast was measured for 5 common radiotherapy techniques, including paired 15 deg. wedges, lateral 30 deg. wedge only, custom-designed physical compensators, aperture based (field-within-field) IMRT with segments chosen by the planner, and inverse planned IMRT with segments chosen by a leaf sequencing algorithm after dose volume histogram (DVH)-based fluence map optimization. Further reduction in contralateral breast dose through the use of lead shielding was also investigated. While shielding was observed to have the most profound impact on surface dose, the radiotherapy technique proved to be most important in determining internal dose. Paired wedges or compensators result in the highest contralateral breast doses (nearly 10% of the prescription dose on the medial surface), while use of IMRT or removal of the medial wedge results in significantly lower doses. Aperture-based IMRT results in the lowest internal doses, primarily due to the decrease in the number of monitor units required and the associated reduction in leakage dose. The use of aperture-based IMRT reduced the average dose to the contralateral breast by greater than 50% in comparison to wedges or compensators. Combined use of IMRT and 1/8-inch-thick lead shielding reduced the dose to the interior and surface of the contralateral breast by roughly 60% and 85%, respectively. This reduction may warrant the use of IMRT for younger patients who have a statistically significant risk of contralateral breast cancer associated with breast radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility Solar Generation Valuation Methods

Tucson Electric Power (TEP) developed, tested and verified the results of a new and appropriate method for accurately evaluating the capacity credit of time variant solar generating sources and reviewed new methods to appropriately and fairly evaluate the value of solar generation to electric utilities. The project also reviewed general integrated approaches for adequately compensating owners of solar generation for their benefits to utilities. However, given the limited funding support and time duration of this project combined with the significant differences between utilities regarding rate structures, solar resource availability and coincidence of solar generation with peak load periods, it is well beyond the scope of this project to develop specific rate, rebate, and interconnection approaches to capture utility benefits for all possible utilities. The project developed computer software based evaluation method models to compare solar generation production data measured in very short term time increments called Sample Intervals over a typical utility Dispatch Cycle during an Evaluation Period against utility system load data. Ten second resolution generation production data from the SGSSS and actual one minute resolution TEP system load data for 2006 and 2007, along with data from the Pennington Street Garage 60 kW DC capacity solar unit installed in downtown Tucson will be applied to the model for testing and verification of the evaluation method. Data was provided by other utilities, but critical time periods of data were missing making results derived from that data inaccurate. The algorithms are based on previous analysis and review of specific 2005 and 2006 SGSSS production data. The model was built, tested and verified by in house TEP personnel. For this phase of the project, TEP communicated with, shared solar production data with and collaborated on the development of solar generation valuation tools with other utilities, including Arizona Public Service, Salt River Project, Xcel and Nevada Power Company as well as the Arizona electric cooperatives. In the second phase of the project, three years of 10 second power output data of the SGSSS was used to evaluate the effectiveness of frequency domain analysis, normal statistical distribution analysis and finally maximum/minimum differential output analysis to test the applicability of these mathematic methods in accurately modeling the output variations produced by clouds passing over the SGSSS array.

14 SOLAR ENERGY↗

Radioxenon production through neutron irradiation of stable xenon gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

ARSA↗

Identification of drug repurposing candidates for amyotrophic lateral sclerosis using electronic health records: a retrospective cohort study

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease with a life expectancy of only 3–5 years and few approved treatments. To identify drug repurposing candidates for the treatment of ALS, we analysed the electronic health records (EHRs) of a large cohort of military veterans with ALS. We analysed the EHRs of individuals in the US Veterans Health Administration (VHA) database who were diagnosed with ALS between Jan 1, 2009 and Dec 31, 2019 to assess medication effects. Individuals without recorded prescriptions after the date of diagnosis were excluded. Two sets of criteria were applied to ascertain exposure. Exposure criteria A were met if the dispense date or the end date of the medication was within 12 months of ALS diagnosis and the end date was at least 6 months after the dispense date. Exposure criteria B were met if there were at least two dispenses within 6 months before diagnosis and 12 months after diagnosis. Propensity score-matched control groups were generated on the basis of confounders included in the EHR, with methodology of potential outcomes used to infer treatment effects. The primary outcome was death. A standard Cox proportional hazards analysis was done to assess association with survival. Survival was defined as the time from diagnosis date recorded in the EHR to death reported in the Department for Veterans Affairs Vital Status File. Follow-up survival time was censored on Dec 31, 2020, for those alive on this date. Downstream protein targets of drugs with clinically significant effects were analysed using the protein–protein interaction networks-based algorithm PathFX. The EHRs of 11 003 individuals with ALS in the VHA database were appropriate for analysis. 162 medications with treatment groups of 30 or more individuals were identified. Among these 162 medications, 27 were associated with statistically significant changes (≥0·1) in the hazard ratio (HR) for death. 18 of the medications were associated with a reduced HR for death (prolonged survival), and nine were associated with an increased HR for death (reduced survival). Drugs associated with reduced HR included HMG-CoA reductase inhibitors (simvastatin, pravastatin, lovastatin, and atorvastatin), PDE5 inhibitors (vardenafil and sildenafil), and α-adrenergic antagonists (tamsulosin and terazosin). The medications associated with an increased HR were drugs used either in the management of clinical features of ALS associated with poor outcomes or in end-of-life care. PathFx analysis identified a complex of proteins interacting with several of the identified drugs. To our knowledge, this analysis is the largest EHR-based study for identifying drug repurposing candidates for ALS. We identified several drugs that warrant further assessment as therapeutic options in ALS, as well as a protein network complex that might serve as a therapeutic target for ALS.

Reimer, Richard J. [Stanford Univ., CA (United Sta↗

Three-dimensional imaging of grain boundaries via quantitative fluorescence X-ray tomography analysis

Abstract Three-dimensional visualization of material composition within multiple grains and across complex networks of grain boundaries at nanoscales can provide new insight into the structure evolution and emerging functional properties of the material for diverse applications. Here, using nanoscale scanning X-ray fluorescence tomography, coupled with an advanced self-absorption correction algorithm developed in this work, we analyze the three-dimensional gain distributions and compositions in a Ce 0.8 Gd 0.2 O 2-δ -CoFe 2 O 4 mixed ionic-electronic conductor system with high accuracy and statistical significance. Our systematic investigation reveals an additional emergent phase and uncovers highly intriguing composition stability ranges for the multiple material phases within this system. The presented visualization of composition variations across complex interfaces, supported by our quantitative composition analysis, discloses mechanistic pathways of the diverse phase transformations occurring in the material synthesis, providing insights for the optimization of transport properties in the mixed ionic-electronic conductor system.

36 MATERIALS SCIENCE↗

Dark Energy Survey Year 3 results: $w$CDM cosmology from simulation-based inference with persistent homology on the sphere

We present cosmological constraints from Dark Energy Survey Year 3 (DES Y3) weak lensing data using persistent homology, a topological data analysis technique that tracks how features like clusters and voids evolve across density thresholds. For the first time, we apply spherical persistent homology to galaxy survey data through the algorithm TopoS2, which is optimized for curved-sky analyses and HEALPix compatibility. Employing a simulation-based inference framework with the Gower Street simulation suite, specifically designed to mimic DES Y3 data properties, we extract topological summary statistics from convergence maps across multiple smoothing scales and redshift bins. After neural network compression of these statistics, we estimate the likelihood function and validate our analysis against baryonic feedback effects, finding minimal biases (under $0.3σ$) in the $Ω_\mathrm{m}-S_8$ plane. Assuming the $w$CDM model, our combined Betti numbers and second moments analysis yields $S_8 = 0.821 \pm 0.018$ and $Ω_\mathrm{m} = 0.304\pm0.037$-constraints 70% tighter than those from cosmic shear two-point statistics in the same parameter plane. Our results demonstrate that topological methods provide a powerful and robust framework for extracting cosmological information, with our spherical methodology readily applicable to upcoming Stage IV wide-field galaxy surveys.

Prat, J. [Nordita; Royal Inst. Tech., Sodertalje; ↗

DESI peculiar velocity survey – Fundamental Plane

The Dark Energy Spectroscopic Instrument (DESI) peculiar velocity survey aims to measure the peculiar velocities of early- and late-type galaxies within the DESI footprint using both the Fundamental Plane and optical Tully–Fisher relations. Direct measurements of peculiar velocities can significantly improve constraints on the growth rate of structure, reducing uncertainty by a factor of approximately 2.5 at redshift 0.1 compared to the DESI Bright Galaxy Survey’s redshift space distortion measurements alone. We assess the quality of stellar velocity dispersion measurements from DESI spectroscopic data. These measurements, along with photometric data from the Legacy Survey, establish the Fundamental Plane relation and determine distances and peculiar velocities of early-type galaxies. During survey validation, we obtain spectra for 6698 unique early-type galaxies, up to a photometric redshift of 0.15. 64 per cent of observed galaxies (4267) have relative velocity dispersion errors below 10 per cent. This percentage increases to 75 per cent if we restrict our sample to galaxies with spectroscopic redshifts below 0.1. We use the measured central velocity dispersion, along with photometry from the DESI Legacy Imaging Surveys, to fit the Fundamental Plane parameters using a 3D Gaussian maximum likelihood algorithm that accounts for measurement uncertainties and selection cuts. In addition, we conduct zero-point calibration using the absolute distance measurements to the Coma cluster, leading to a value of the Hubble constant, H 0 = 76.05 ± 0.35 (statistical) ±0.49 (systematic Fundamental Plane) ±4.86 (statistical due to calibration) km s –1 Mpc –1 ⁠. This H 0 value is within 2σ of Planck cosmic microwave background results and within 1σ of other low-redshift distance indicator-based measurements.

cosmological parameters↗

GUNDAM: a toolkit for fast spatial correlation functions in galaxy surveys

ABSTRACT We describe the capabilities of a new software package to calculate two-point correlation functions (2PCFs) of large galaxy samples. The code can efficiently estimate 3D/projected/angular 2PCFs with a variety of statistical estimators and bootstrap errors, and is intended to provide a complete framework (including calculation, storage, manipulation, and plotting) to perform this type of spatial analysis with large redshift surveys. Gundam implements a very fast skip list/linked list algorithm that efficiently counts galaxy pairs and avoids the computation of unnecessary distances. It is several orders of magnitude faster than a naive pair counter, and matches or even surpass other advanced algorithms. The implementation is also embarrassingly parallel, making full use of multicore processors or large computational clusters when available. The software is designed to be flexible, user friendly and easily extensible, integrating optimized, well-tested packages already available in the astronomy community. Out of the box, it already provides advanced features such as custom weighting schemes, fibre collision corrections and 2D correlations. Gundam will ultimately provide an efficient toolkit to analyse the large-scale structure ‘buried’ in upcoming extremely large data sets generated by future surveys.

Donoso, E.↗

BioXTAS RAW 2 : new developments for a free open-source program for small-angle scattering data reduction and analysis

BioXTAS RAW is a free open-source program for reduction, analysis and modelling of biological small-angle scattering data. Here, the new developments in RAW version 2 are described. These include improved data reduction using pyFAI ; updated automated Guinier fitting and D max finding algorithms; automated series ( e.g. size-exclusion chromatography coupled small-angle X-ray scattering or SEC-SAXS) buffer- and sample-region finding algorithms; linear and integral baseline correction for series; deconvolution of series data using regularized alternating least squares ( REGALS ); creation of electron-density reconstructions using electron density via solution scattering ( DENSS ); a comparison window showing residuals, ratios and statistical comparisons between profiles; and generation of PDF reports with summary plots and tables for all analysis. Furthermore, there is now a RAW API, which can be used without the graphical user interface (GUI), providing full access to all of the functionality found in the GUI. In addition to these new capabilities, RAW has undergone significant technical updates, such as adding Python 3 compatibility, and has entirely new documentation available both online and in the program.

97 MATHEMATICS AND COMPUTING↗

Assessment of Industrial Load for Demand Response across U.S. Regions of the Western Interconnect

Demand response (DR) has the ability to both increase power grid reliability and potentially reduce operating system costs. Understanding the role of demand response in grid modeling has been difficult due to complex nature of the load characteristics compared to the modeled generation and the variation in load types. This is particularly true of industrial loads, where hundreds of different industries exist with varying availability for demand response. We present a framework considering industrial loads for the development of availability profiles that can provide more regional understanding and can be inserted into analysis software for further study. The developed framework utilizes a number of different informational resources, algorithms, and real-world measurements to perform a bottom-up approach in the development of a new database with representation of the potential demand response resource in the industrial sector across the U.S. This tool houses statistical values of energy and demand response (DR) potential by industrial plant and geospatially locates the information for aggregation for different territories without proprietary information. This report will discuss this framework and the analyzed quantities of demand response for Western Interconnect (WI) in support of evaluation of the cost production modeling with power grid modeling efforts of demand response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Modeling Efforts for Headspace Gas

The purpose of this document is to describe the statistical modeling effort for gas concentrations in WIPP storage containers. The concentration (in ppm) of CO 2 in the headspace volume of standard waste box (SWB) 68685 is shown. A Bayesian approach and an adaptive Metropolis-Hastings algorithm were used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗