Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Cloud Edge Properties Measured by the ARM Shortwave Spectrometer Over Ocean and Land

In this paper, we use the spectrally invariant method to study the variability of cloud optical thickness (τ) and droplet effective radius (r eff ) in transition zones between the cloudy and clear-sky columns observed by Shortwave Array Spectroradiometer-Zenith at the Southern Great Plains Central Facility site (SGP C1) and during the Marine ARM GPCI Investigation of Clouds (MAGIC) field campaign. The spectrally invariant method approximates the spectra in the transition zone as a linear combination of definitely clear and definitely cloudy spectra. The slope and intercept of the linear relations characterize τ and r eff in the transition region, respectively. The radiative transfer model simulations show that that (i) the slope of the visible band is positively correlated with τ, while (ii) the intercept of the near-infrared band has a high negative correlation with r eff . We have analyzed 22 cloud edge cases from the SGP and MAGIC and found that from cloud to clear in the transitions, (a) the slopes of the visible band decrease, indicating the decrease of τ toward cloud edges, and (b) the intercepts of the near-infrared band show a much more significant increase at the SGP than from the MAGIC. The results from observed cases suggest that while τ decreases for all cases, the decrease in r eff is much more significant for cloud over land at the SGP site compared to the ocean counterpart during the MAGIC campaign.

54 ENVIRONMENTAL SCIENCES↗

A combined droplet train and ambient pressure photoemission spectrometer for the investigation of liquid/vapor interfaces

We describe a combined ambient pressure photoelectron spectroscopy/droplet train apparatus for investigating the nature and heterogeneous chemistry of liquid/vapor interfaces. In this instrument a liquid droplet train with typical droplet diameters from 50...150 {micro}m is produced by a vibrating orifice aerosol generator (VOAG). The droplets are irradiated by soft X-rays (100...1500 eV) in front of the entrance aperture of a differentially pumped electrostatic lens system that transfers the emitted electrons into a conventional hemispherical electron analyzer. The photoemission experiments are performed at background pressures of up to several Torr, which allows the study of environmentally important liquid/vapor interfaces, in particular aqueous solutions, under equilibrium conditions. The exposure time of the droplet surface to the background gases prior to the XPS measurement can be varied, which will allow future kinetic measurements of gas uptake on liquid surfaces. As an example, a measurement of the surface composition of a {chi} = 0.21 aqueous methanol solution is presented. The concentration of methanol at the vapor/liquid interface is enhanced by a factor of about 3 over the bulk value, while the expected bulk value is recovered at depths larger than about 1.5 nm.

54 ENVIRONMENTAL SCIENCES↗

Measurement of {pi}{sup +}{pi}{sup -} Photoproduction in Double Polarization Experiments using the CLAS Spectrometer

Spectroscopic predictions based on first principles are not possible in the non-perturbative regime of Quantum Chromodynamics (QCD) where the strong coupling constant is large. For this reason, effective theories and models have been developed to determine the masses, couplings, and decay widths of resonances. Various constituent quark models (CQMs) based on three quark degrees of freedom predict numerous baryon resonances that have not been experimentally verified and are thus 'missing'. The persistent non-observation of these states would present a big problem as the models would have failed to describe physical reality. CQMs predict strong couplings of these unobserved or missing states to {gamma}N as well as to N{eta}, N{eta}{sup '} or {delta}{pi}({delta}{yields}p{pi}) making photoproduction experiments a promising method to find these missing resonances. Previous analyses of unpolarized data show the importance of polarization obervables because some resonances reveal themselves more clearly in the interference with more dominant amplitudes. In addition, the determination of resonant contributions based on unpolarized data is not unique and requires further constraints provided by single- and double-polarization observables in the Partial Wave Analysis (PWA). A linearly- and circularly-polarized photon beam will be incident on a frozen-spin butanol target in Jefferson Lab's Hall B CLAS detector located in Newport News, Va. This detector allows the target to be polarized both longitudinally as well as transversely giving rise to measurable polarization observables in {pi}{sup +}{pi}{sup -} photoproduction. This experiment (FROST) will shed some light on the problem of the missing baryon resonances serving to better understand the properties of these states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian and maximum entropy methods for fusion diagnostic measurements with compact neutron spectrometers

In applications of neutron spectrometry to fusion diagnostics, it is advantageous to use methods of data analysis which can extract information from the spectrum that is directly related to the parameters of interest that describe the plasma. We present here methods of data analysis which were developed with this goal in mind, and which were applied to spectrometric measurements made with an organic liquid scintillation detector (type NE213). In our approach, we combine Bayesian parameter estimation methods and unfolding methods based on the maximum entropy principle. This two-step method allows us to optimize the analysis of the data depending on the type of information that we want to extract from the measurements. To illustrate these methods, we analyze neutron measurements made at the PTB accelerator under controlled conditions, using accelerator-produced neutron beams. Although the methods have been chosen with a specific application in mind, they are general enough to be useful for many other types of measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extending the dynamic range of nuclear pulse spectrometers

Using an innovative time-varying front-end electronics in conjunction with a bulky coaxial high-purity germanium detector, we were able to extend the range of the radionuclide spectra well beyond the analog to digital converter (ADC) saturation point. The electronics automatically conditions the signal for digital-filtering optimization if it is in the ADC voltage range and for time-over-threshold analysis if it exceeds the ADC range. A high spectroscopic resolution has been achieved in both operation ranges. An unprecedented wide energy range from 5 keV to 150 MeV of equivalent energy, or 90 dB, has been obtained using a single acquisition chain, while maintaining a high-energy resolution in the whole spectrum. For example, with an ADC range of 3 MeV a resolution has been obtained of 1.3/2.2 keV full width at half maximum on the 122/1332 keV gamma-ray lines of {sup 57}Co and {sup 60}Co, and of <0.4% in the time-over-threshold region, or for energy deposits beyond 3 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of an electron spectrometer using high energy electrons produced by the laser-plasma interaction

An in situ observation system has been developed to observe the absolute electron energy spectra of electron beams generated by laser-plasma interaction. A phosphor screen (DRZ) coupled with a charge coupled device camera is used to detect the electrons. A new method is proposed to calibrate the absolute sensitivity of the detection system for a wide energy range with a single shot by using an electron beam generated by laser-plasma interaction. The sensitivity of the system is found to be high, which is comparable to that of an imaging plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A picosecond time-resolved electron energy spectrometer based on Cerenkov radiation

The energy spectrum of relativistic electrons is an important characterization of high intensity laser-matter interactions. We present a technique that utilizes Cerenkov radiation to measure the time-resolved energy distribution of electrons. Electrons escaping from targets irradiated by high-intensity laser pulses were measured, demonstrating the feasibility of such a novel diagnostic. Limitations on the time resolution of this diagnostic are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complementary ion and extreme ultra-violet spectrometer for laser-plasma diagnosis

Simultaneous detection of extreme ultra-violet (XUV) and ion emission along the same line of sight provides comprehensive insight into the evolution of plasmas. This type of combined spectroscopy is applied to diagnose laser interaction with a spray target. The use of a micro-channel-plate detector assures reliable detection of both XUV and ion signals in a single laser shot. The qualitative analysis of the ion emission and XUV spectra allows to gain detailed information about the plasma conditions, and a correlation between the energetic proton emission and the XUV plasma emission can be suggested. The measured XUV emission spectrum from water spray shows efficient deceleration of laser accelerated electrons with energies up to keV in the initially cold background plasma and the collisional heating of the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryostat design and analysis of the superconducting magnets for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes the mechanical design and analysis of the cryostats for the two cos(2theta) quadrupoles and the cos(theta) dipole. All the magnets are currently being bid for commercial fabrication. The results of finite element analysis for the magnet cryostat helium vessels and outer vacuum chambers which investigate the mechanical integrity under maximum allowable internal working pressure, maximum allowable external working pressure, and cryogenic temperature are discussed. The allowable stress criterion is determined based on the allowable stress philosophy of the ASME codes. The computed cryogenic heat load of the magnets is compared with the allowable cryogenic consumption budget. The presented cool-down time of the magnets was studied under the conditions of a limited supply rate and a controlled temperature differential of 50 K in the magnets.

43 PARTICLE ACCELERATORS↗

Design and analysis of the warm-to-cold suspension links for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes design and analysis performed for the warm-to-cold suspension links of the warm iron yoke superconducting quadrupole magnets, and superconducting dipole magnet. The results of investigation of titanium Ti-6Al-4V and Nitronic 50 stainless steel for the suspension links to support the cold mass, preloads, forces due to cryogenic temperature, and imbalanced magnetic forces from misalignments are presented. Allowable stresses at normal-case scenarios and worst-case scenarios, space constraints, and heat leak considerations are discussed. Principles of the ASME Pressure Vessel Code were used to determine allowable stresses. Optimal angles of the suspension links were obtained by calculation and finite element methods. The stress levels of suspension links at multiple scenarios are presented, discussed, and compared with the allowable stresses.

36 MATERIALS SCIENCE↗

A KB-Focusing Mirror Pair for a VUV-Raman Spectrometer at FLASH - Mirror Metrology and Ray Tracing Results

A plane mirror and two strongly curved plane elliptical mirrors comprising the refocusing system downstream the plane grating monochromator at FLASH in DESY have been characterized with the Nanometer Optical Component Measuring Machine at the BESSY-II Optics Laboratory of the Helmholtz Zentrum Berlin. Based on the measurement results the two elliptical cylinders were optimized by deterministic surface finishing technology (Ion Beam Finishing). The expected focusing performance was verified by ray tracings after each ion beam finish iteration using the measured topography results.

43 PARTICLE ACCELERATORS↗

Experimental Determination of the HPGe Spectrometer Efficiency Calibration Curves for Various Sample Geometry for Gamma Energy from 50 keV to 2000 keV

Detection efficiency of a gamma-ray spectrometry system is dependent upon among others, energy, sample and detector geometry, volume and density of the samples. In the present study the efficiency calibration curves of newly acquired (August 2008) HPGe gamma-ray spectrometry system was carried out for four sample container geometries, namely Marinelli beaker, disc, cylindrical beaker and vial, normally used for activity determination of gamma-ray from environmental samples. Calibration standards were prepared by using known amount of analytical grade uranium trioxide ore, homogenized in plain flour into the respective containers. The ore produces gamma-rays of energy ranging from 53 keV to 1001 keV. Analytical grade potassium chloride were prepared to determine detection efficiency of 1460 keV gamma-ray emitted by potassium isotope K-40. Plots of detection efficiency against gamma-ray energy for the four sample geometries were found to fit smoothly to a general form of {epsilon} = A{Epsilon}{sup a}+B{Epsilon}{sup b}, where {epsilon} is efficiency, {Epsilon} is energy in keV, A, B, a and b are constants that are dependent on the sample geometries. All calibration curves showed the presence of a ''knee'' at about 180 keV. Comparison between the four geometries showed that the efficiency of Marinelli beaker is higher than cylindrical beaker and vial, while cylindrical disk showed the lowest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impurity temperature correction factors for the transmission grating spectrometer in the TJ-II stellarator

Impurity ion temperature and velocity profiles are obtained across plasmas in the TJ-II stellarator by performing charge-exchange recombination spectroscopy with a diagnostic neutral beam injector. For this, a tridirectional (toroidal plus two poloidal opposing views) multichannel spectroscopic diagnostic, incorporating 12-way fiber arrays, a compact f/1.8 spectrograph, and a back-illuminated CCD, permits Doppler line shifts and widths (of the C VI line at 529.05 nm) to be determined with 1-2 cm spatial resolution. For good photon counting statistics under Li-coated wall conditions, 600 {mu}m diameter fibers collect and transmit light to curved 100 {mu}m wide input slits. When calibrated with a neon pencil lamp this entrance slit width results in a non-Gaussian instrumental function that, if not handled correctly, can result in systematically underestimated impurity temperatures. Here we develop and present correction factors for this effect for a range of conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical ionization tandem mass spectrometer for the in situ measurement of methyl hydrogen peroxide

A new approach for measuring gas-phase methyl hydrogen peroxide [(MHP) CH{sub 3}OOH] utilizing chemical ionization mass spectrometry is presented. Tandem mass spectrometry is used to avoid mass interferences that hindered previous attempts to measure atmospheric CH{sub 3}OOH with CF{sub 3}O{sup -} clustering chemistry. CH{sub 3}OOH has been successfully measured in situ using this technique during both airborne and ground-based campaigns. The accuracy and precision for the MHP measurement are a function of water vapor mixing ratio. Typical precision at 500 pptv MHP and 100 ppmv H{sub 2}O is {+-}80 pptv (2 sigma) for a 1 s integration period. The accuracy at 100 ppmv H{sub 2}O is estimated to be better than {+-}40%. Chemical ionization tandem mass spectrometry shows considerable promise for the determination of in situ atmospheric trace gas mixing ratios where isobaric compounds or mass interferences impede accurate measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Binding energy scale calibration of electron spectrometers for photoelectron spectroscopy using a single sample

The feasibility of calibrating the binding energy scale for photoelectron spectroscopy using a single sample without sputter cleaning was investigated. By measuring the Fermi level of a Au film with both monochromatic Al K{alpha} (h{nu}= 1486.7 eV) and He I{alpha} (h{nu}= 21.22 eV), the binding energy scale was simply and accurately calibrated. This method is found to yield binding energy values for the Cu 2p{sub 3/2}, Ag 3d{sub 5/2}, and Au 4f{sub 7/2} peaks that agree with the standard tabulated values defined in International Organization for Standardization 15472 to within {+-}0.02 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Project 8: Update on a radiofrequency tritium spectrometer

We describe a novel technique for measuring the energies of beta decay electrons. The technique relies on the detection of coherent radiation emitted by an electron in a cyclotron orbit in a strong magnetic field. Since the frequency of cyclotron orbit depends on the particle Lorentz boost, the detection and measurement of the coherent radiation emitted is tantamount to measuring the kinetic energy of the electron. As the technique inherently involves a nondestructive frequency measurement, it can in principle achieve a high resolution and accuracy. A new experimental effort, known as Project 8, will apply this technique to a sensitive measurement of the beta endpoint of tritium, which is sensitive to the absolute mass scale of the neutrino. In this paper we describe experimental progress towards demonstrating the Project 8 technique, and present the configuration of a pilot experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the polarization observables I^S and I^c for {gamma}p-->p{pi}^+{pi}^- using the CLAS spectrometer

Constituent Quark Models predict an excited baryon spectrum much richer in resonances than that which has been observed experimentally, the so-called missing resonance problem. Evidence for the production of these short-lived states may come about through measurements of quantities called polarization observables. These observables occur when the constraint of polarization is imposed on the reactions and are highly sensitive to resonance production. The expected sequential decay of these N* resonances via {pi}{Delta} and N{Delta} intermediate states makes the double pion final state an attractive final state to study to reveal these missing resonances. In recent years, both single- and double-polarization experiments have been carried out as part of the N* program at Jefferson Lab in Newport News, Virginia with the goal of resolving this missing resonance problem. One such polarized photoproduction experiment used linearly polarized photons incident on an unpolarized LH{sub 2} target. The analysis of {gamma}p {yields} {pi}{sup +}{pi}{sup -} reactions found in these polarized photoproduction data using the power of a kinematic fitter results in highly accurate measurements of these observables. The analysis of this p{pi}{sup +}{pi}{sup -} final state and the extraction of two such observables, I{sup S} and I{sup c}, will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗