Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Security Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Review of Qualitative Approaches for the Construction Industry: Designing a Risk Management Toolbox

Objectives: This paper presents the framework and protocol design for a construction industry risk management toolbox. The construction industry needs a comprehensive, systematic approach to assess and control occupational risks. These risks span several professional health and safety disciplines, emphasized by multiple international occupational research agenda projects including: falls, electrocution, noise, silica, welding fumes, and musculoskeletal disorders. Yet, the International Social Security Association says, “whereas progress has been made in safety and health, the construction industry is still a high risk sector.” Methods: Small- and medium-sized enterprises (SMEs) employ about 80% of the world’s construction workers. In recent years a strategy for qualitative occupational risk management, known as Control Banding (CB) has gained international attention as a simplified approach for reducing work-related risks. CB groups hazards into stratified risk ‘bands’, identifying commensurate controls to reduce the level of risk and promote worker health and safety. We review these qualitative solutions-based approaches and identify strengths and weaknesses toward designing a simplified CB ‘toolbox’ approach for use by SMEs in construction trades. Results: This toolbox design proposal includes international input on multidisciplinary approaches for performing a qualitative risk assessment determining a risk ‘band’ for a given project. Risk bands are used to identify the appropriate level of training to oversee construction work, leading to commensurate and appropriate control methods to perform the work safely. Conclusion: The Construction Toolbox presents a review-generated format to harness multiple solutions-based national programs and publications for controlling construction-related risks with simplified approaches across the occupational safety, health and hygiene professions.

60 APPLIED LIFE SCIENCES↗

Multi-discipline Waste Acceptance Process at the Nevada National Security Site - 13573

The Nevada National Security Site low-level radioactive waste disposal facility acceptance process requires multiple disciplines to ensure the protection of workers, the public, and the environment. These disciplines, which include waste acceptance, nuclear criticality, safety, permitting, operations, and performance assessment, combine into the overall waste acceptance process to assess low-level radioactive waste streams for disposal at the Area 5 Radioactive Waste Management Site. Four waste streams recently highlighted the integration of these disciplines: the Oak Ridge Radioisotope Thermoelectric Generators and Consolidated Edison Uranium Solidification Project material, West Valley Melter, and classified waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inadvertent Disposal of Chromium Waste at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nevada

Nuclear Fuel Services, Inc. (NFS), a waste generator approved to ship waste to the Nevada National Security Site (NNSS), made 49 waste shipments in the period 2009 to 2015 that were subsequently determined to contain chromium that exceeded the Toxicity Characteristic Leaching Procedure regulatory limit, which would require the waste to carry hazardous waste code D007. One of the 49 shipments contained bottles of liquid blowback solution and was returned to NFS for disposition. The remaining 48 shipments consisted of a total of 93 disposal packages of chromium-containing waste that were disposed in seven low-level waste (LLW) cells at the Area 5 Radioactive Waste Management Site (RWMS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Approach for Assessing Consequences of Potential Supply Chain and Insider Contributed Cyber Attacks on Nuclear Power Plants

The Stuxnet attack at the Natanz facility is an example of a targeted and successful cyber attack on a nuclear facility. Snowden's release of National Security Agency documents demonstrated the consequences of the insider threat. More recently, the United States tried to attack North Korea but failed, South Korea was attempting to attack North Korea, and both applied Stuxnet-like approaches. These sophisticated targeted attacks differ from web-site hacking events that are reported almost daily in the news mainly because targeted attacks require detailed design and operation information of the systems attacked and/or are often carried out by insiders. For instance, in order to minimize disruption of facilities around the world, Stuxnet remained idle until it recognized the specific configuration of the Natanz facility, demonstrating that the attackers possessed extremely detailed information about the facility. Such targeted cyber attacks could become a national-level military weapon and be used in coercion of hostile countries.

42 ENGINEERING↗

CY2018 Annual Closure Monitoring Report for Corrective Action Unit 98, Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada (January 2018–December 2018, Revision 1)

Corrective Action Unit (CAU) 98: Frenchman Flat on the Nevada National Security Site was the location of 10 underground nuclear tests. CAU 98 underwent a series of investigations and actions in accordance with the Federal Facility Agreement and Consent Order to assess contamination of groundwater by radionuclides from the tests. A Closure Report completed that process in 2016 and called for long-term monitoring, use restrictions (URs), and institutional controls to protect the public and environment from potential exposure to contaminated groundwater. Three types of monitoring are performed for CAU 98: water quality, water level, and institutional control. These are monitored to determine whether the URs remain protective of human health and the environment, and to ensure that the regulatory boundary objectives are being met. Monitoring data will be used in the future, once multiple years of data are available, to evaluate consistency with the groundwater flow and contaminant transport models because the contaminant boundaries calculated with the models are the primary basis of the UR boundaries. Six wells were sampled for water-quality monitoring in 2018. Contaminants of concern were detected only in the two source/plume wells already known to contain contamination as a result of a radionuclide migration experiment. Tritium concentrations in both of these wells, RNM-2S and UE-5n, remain above the Safe Drinking Water Act maximum contaminant level of 20,000 picocuries per liter but declined in 2018 as compared to measurements in 2017. All other contaminants of concern are below the minimum detection level plus analytical error. The water-level monitoring network includes 16 wells. Depth to water measured in 2018 is generally consistent with recent measurements for all wells. Many wells continue to exhibit a long-term downward trend in water level, despite small increases in measured water levels in 2018. The sharp 2016 decline in water level in Well ER-5-3-2 remains unexplained, with the lower level persisting through 2018. Rising water-level trends continue to be observed in two relatively deep wells (ER-5-3 deep piezometer and ER-5-4-2), and also in former supply Well WW-5A. The current supply wells exhibit relatively erratic water levels associated with pumping activities. Institutional control monitoring confirmed the URs are recorded in U.S. Department of Energy and U.S. Air Force land management systems, and that no activities within Frenchman Flat basin are occurring that could potentially affect the contaminant boundaries. Survey of groundwater resources in basins surrounding Frenchman Flat similarly identify no current or pending development that would indicate the need to increase monitoring activities or would otherwise cause concern for the closure decision. The URs continue to prevent exposure of the public, workers, and the environment to contaminants of concern by preventing use of potentially contaminated groundwater.

54 ENVIRONMENTAL SCIENCES↗

APPLICATION OF MATURITY MODELS FOR EVALUATING CYBERSECURITY PROGRAMS AT NUCLEAR AND RADIOLOGICAL FACILITIES

Maturity models can be used to provide government agencies, industry associations, and organizations operating nuclear facilities with the ability to quickly evaluate the maturity of their cybersecurity programs and identify areas to prioritize for improvement. The Cybersecurity Capability Maturity Model (C2M2) was developed by the U.S. Department of Energy to allow organizations in the energy sector to evaluate the programmatic capabilities of their cybersecurity programs in a consistent manner, communicate programmatic maturity information, prioritize cybersecurity investments in targeted areas of concern, and track how the maturity of their cybersecurity program evolves over time. The C2M2 is designed for use by any critical infrastructure organization regardless of ownership, structure, or size. The C2M2 can be easily fine-tuned to access the maturity of nuclear cybersecurity programs and their application at individual facilities. Built on a foundation of existing cybersecurity standards, frameworks, programs, and initiatives, the model features 10 security domains. Performance in each security domain is characterized using a structured set of cybersecurity practices that represent activities an organization can perform to improve cybersecurity in their domain. Each practice can be quickly evaluated as being either fully, largely, partially, or not implemented. Once practices are evaluated for each security domain, the model defines four maturity indicator levels that apply independently to each domain in the model. To earn a maturity level in a given domain, an organization must adequately perform all the practices for that maturity level and its predecessor level(s). A small assessment team can conduct a C2M2 assessment in a single day. A screening version of the C2M2 allows an initial look at the maturity of nuclear cybersecurity programs that could be completed in under an hour.

Cyber security, Nuclear security, maturity model↗

Strategic Energy Management Plan for the Santa Ynez Band of Chumash Indians

This plan outlines the Santa Ynez Band of Chumash Indians’ comprehensive energy management strategy including an assessment of current practices, a commitment to improving energy performance and reducing overall energy use, and recommended actions to achieve these goals. Vision Statement: The primary objective of the Strategic Energy Management Plan is to implement energy efficiency, energy security, conservation, education, and renewable energy projects that align with the economic goals and cultural values of the community to improve the health and welfare of the tribe. The intended outcomes of implementing the energy plan include job creation, capacity building, and reduced energy costs for tribal community members, and tribal operations. By encouraging energy independence and local power production the plan will promote self-sufficiency. Mission & Objectives: The Strategic Energy Plan will provide information and suggestions to guide tribal decision-making and provide a foundation for effective management of energy resources within the Santa Ynez Band of Chumash Indians (SYBCI) community. The objectives of developing this plan include; Assess current energy demand and costs of all tribal enterprises, offices, and facilities; Provide a baseline assessment of the SYBCI’s energy resources so that future progress can be clearly and consistently measured, and current usage better understood; Project future energy demand; Establish a system for centralized, ongoing tracking and analysis of tribal energy data that is applicable across sectors, facilities, and activities; Develop a unifying vision that is consistent with the tribe’s long-term cultural, social, environmental, and economic goals; Identify and evaluate the potential of opportunities for development of long-term, cost effective energy sources, such as renewable energy, energy efficiency and conservation, and other feasible supply- and demand-side options; and Build the SYBCI’s capacity for understanding, managing, and developing energy resources by identifying training, distribution of information materials, and community meeting needs and opportunities

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Testing the suitability of geologic frameworks for extrapolating hydraulic properties across regional scales

The suitability of geologic frameworks for extrapolating hydraulic conductivity (K) to length scales commensurate with hydraulic data is difficult to assess. A novel method is presented for evaluating assumed relations between K and geologic interpretations for regional-scale groundwater modeling. The approach relies on simultaneous interpretation of multiple aquifer tests using alternative geologic frameworks of variable complexity, where each framework is incorporated as prior information that assumes homogeneous K within each model unit. This approach is tested at Pahute Mesa within the Nevada National Security Site (USA), where observed drawdowns from eight aquifer tests in complex, highly faulted volcanic rocks provide the necessary hydraulic constraints. The investigated volume encompasses 40 mi3 (167 km3) where drawdowns traversed major fault structures and were detected more than 2 mi (3.2 km) from pumping wells. Complexity of the five frameworks assessed ranges from an undifferentiated mass of rock with a single unit to 14 distinct geologic units. Results show that only four geologic units can be justified as hydraulically unique for this location. The approach qualitatively evaluates the consistency of hydraulic property estimates within extents of investigation and effects of geologic frameworks on extrapolation. Distributions of transmissivity are similar within the investigated extents irrespective of the geologic framework. In contrast, the extrapolation of hydraulic properties beyond the volume investigated with interfering aquifer tests is strongly affected by the complexity of a given framework. As a result, testing at Pahute Mesa illustrates how this method can be employed to determine the appropriate level of geologic complexity for large-scale groundwater modeling.

58 GEOSCIENCES↗

Keyless Infrastructure Security Solution (KISS): VOLTTRON™ KSI ® Blockchain Design and Specification

This document provides the technical design specifications that are required for Keyless Infrastructure Security Solution (KISS) development, including, definitions and roles of the new KISS-related products—GridAware and LinkLite—an overview of the DNP3 communications the VOLTTRON™ DNP3 agent is using for distribution control, data flow, historian processing, setup, and installation. These technical specifications provide step-by-step instructions for configuration, implementation, and deployment of the KISS subsystem, docket creation, and verification using the GridAware dashboard. Based on this document and the KISS specification requirements and device risk assessment documents, KISS will be developed by integrating keyless signature infrastructure (KSI) blockchain to increase the cybersecurity, integrity, and trustworthiness of critical energy delivery systems (EDSs). The KISS architecture consists of a VOLTTRON™ agent-based distribution control system platform and GridAware (KSI blockchain capability) for secure energy exchanges in a decentralized electrical network.

42 ENGINEERING↗