Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

ARIES-ACT1 Safety Design and Analysis

ARIES-ACT1 (Advanced and Conservative Tokamak) is a 1000-MW(electric) tokamak design featuring advanced plasma physics and divertor and blanket engineering. Some relevant features include an advanced SiC blanket with PbLi as coolant and breeder; a helium-cooled steel structural ring and tungsten divertors; a thin-walled, helium-cooled vacuum vessel; and a room-temperature, water-cooled shield outside the vacuum vessel. We consider here some safety aspects of the ARIES-ACT1 design and model a series of design-basis and beyond-design-basis accidents with the MELCOR code modified for fusion. The presence of multiple coolants (PbLi, helium, and water) makes possible a variety of such accidents. We consider here a loss-of-flow accident caused by a long-term station blackout (LTSBO), an ex-vessel helium break into the cryostat, and a beyond-design-basis accident in which a LTSBO is aggravated by a loss-of-coolant accident in ARIES-ACT1's ultimate decay heat removal system, the water-cooled shield. In the design-basis accidents, we find that the secondary confinement boundaries are not challenged, and the structural integrity of in-vessel components is not threatened by high temperatures or pressures; decay heat can be passively removed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HAZARD ANALYSIS SOFTWARE

Washington Safety Management Solutions, LLC developed web-based software to improve the efficiency and consistency of hazard identification and analysis, control selection and classification, and to standardize analysis reporting at Savannah River Site. In the new nuclear age, information technology provides methods to improve the efficiency of the documented safety analysis development process which includes hazard analysis activities. This software provides a web interface that interacts with a relational database to support analysis, record data, and to ensure reporting consistency. A team of subject matter experts participated in a series of meetings to review the associated processes and procedures for requirements and standard practices. Through these meetings, a set of software requirements were developed and compiled into a requirements traceability matrix from which software could be developed. The software was tested to ensure compliance with the requirements. Training was provided to the hazard analysis leads. Hazard analysis teams using the software have verified its operability. The software has been classified as NQA-1, Level D, as it supports the analysis team but does not perform the analysis. The software can be transported to other sites with alternate risk schemes. The software is being used to support the development of 14 hazard analyses. User responses have been positive with a number of suggestions for improvement which are being incorporated as time permits. The software has enforced a uniform implementation of the site procedures. The software has significantly improved the efficiency and standardization of the hazard analysis process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Aviation Safety Reporting System Incident Data Associated with the Technical Challenges of the Atmospheric Environment Safety Technology Project

This study analyzed aircraft incidents in the NASA Aviation Safety Reporting System (ASRS) that apply to two of the three technical challenges (TCs) in NASA's Aviation Safety Program's Atmospheric Environment Safety Technology Project. The aircraft incidents are related to airframe icing and atmospheric hazards TCs. The study reviewed incidents that listed their primary problem as weather or environment-nonweather between 1994 and 2011 for aircraft defined by Federal Aviation Regulations (FAR) Parts 121, 135, and 91. The study investigated the phases of flight, a variety of anomalies, flight conditions, and incidents by FAR part, along with other categories. The first part of the analysis focused on airframe-icing-related incidents and found 275 incidents out of 3526 weather-related incidents over the 18-yr period. The second portion of the study focused on atmospheric hazards and found 4647 incidents over the same time period. Atmospheric hazards-related incidents included a range of conditions from clear air turbulence and wake vortex, to controlled flight toward terrain, ground encounters, and incursions.

Withrow, Colleen A.↗

Seismic and LOCA safety testing and analysis program for Westinghouse PWR fuel under end of life conditions

The NRC issued Information Notice - IN 2012-09 in June 2012 which challenges approved assumptions based on the beginning of life (BOL) conditions in seismic and LOCA analysis. Westinghouse manufactures a variety of PWR fuel designs, including 14*14, 15*15, 16*16 and 17*17 array, also different fuel lengths from 12 feet to 14 feet. The fuels are supplied to the cores designed by Westinghouse and Combustion Engineering, and other cores around world. To address IN 2012-09 efficiently and economically, Westinghouse and PWR Owner Groups launched a testing and analysis program funded by PWROG. The program planed testing and analysis matrices based on types of fuel designs. The testing plan includes grid crush tests, fuel assembly mechanical tests and flowing water damping tests. Applying modelling technique, the program will reduce the number of test and cost. The ultimate goal of the program is to generate fuel assembly EOL models for all fuel designs manufactured by Westinghouse and to be ready for any plant specific seismic and LOCA analysis to address NRC IN for EOL effect. The phase I of PWROG for EOL conditions has been completed and several conclusions are obtained. First, the gapped grids reduce grid dynamic stiffness, local impact stiffness and crush strength. Also, due to gapped grids, both the fuel assembly natural frequency and stiffness are reduced. Secondly, applying higher fuel assembly damping due to the flowing water effect can significantly reduce fuel assembly impact forces. However, during a seismic event the reactor coolant pumps may trip resulting in a coast-down. As such, reduced flow rates that occur during the pump coast-down must be considered. Thirdly, the analytical model representation of a reactor core adequately characterizes the core response under seismic and LOCA excitations. Static and dynamic structural test results of a fuel assembly compared with analytical predictions indicate that the fuel assembly lateral and axial structural behavior can be fully determined with finite element models. Fourthly, analyses for EOL fuel assemblies under seismic and LOCA loads demonstrate EOL effect and flowing water damping effect. With flowing water damping benefit, significant margin can be recovered for fuel assemblies with EOL conditions and under seismic loads.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Critical review and analysis of hydrogen safety data collection tools

The wider adoption of hydrogen in multiple sectors of the economy requires that safety and risk issues be rigorously investigated. Quantitative Risk Assessment (QRA) is an important tool for enabling safe deployment of hydrogen fueling stations and is increasingly embedded in the permitting process. QRA requires reliability data, and currently hydrogen QRA is limited by the lack of hydrogen specific reliability data, thereby hindering the development of necessary safety codes and standards [1]. Four tools have been identified that collect hydrogen system safety data: H2Tools Lessons Learned, Hydrogen Incidents and Accidents Database (HIAD), National Renewable Energy Lab's (NREL) Composite Data Products (CDPs), and the Center for Hydrogen Safety (CHS) Equipment and Component Failure Rate Data Submission Form. This work critically reviews and analyzes these tools for their quality and usability in QRA. It is determined that these tools lay a good foundation, however, the data collected by these tools needs improvement for use in QRA. Areas in which these tools can be improved are highlighted, and can be used to develop a path towards adequate reliability data collection for hydrogen systems.

08 HYDROGEN↗

Accelerated Hypofractionated Intensity-Modulated Radiotherapy With Concurrent and Adjuvant Temozolomide for Patients With Glioblastoma Multiforme: A Safety and Efficacy Analysis

Purpose: Despite multimodality treatments, the outcome of patients with glioblastoma multiforme remains poor. In an attempt to improve results, we have begun a program of accelerated hypofractionated intensity-modulated radiotherapy (hypo-IMRT) with concomitant and adjuvant temozolomide (TMZ). Methods and Materials: Between March 2004 and June 2006, 35 unselected patients with glioblastoma multiforme were treated with hypo-IMRT. During a 4-week period, using a concomitant boost technique, a dose of 60 Gy and 40 Gy were delivered in 20 fractions prescribed to the periphery of the gross tumor volume and planning target volume, respectively. TMZ was administered according to the regimen of Stupp et al. Results: The median follow-up was 12.6 months. Of the 35 patients, 29 (82.8%) completed the combined modality treatment, and 25 (71.4%) received a median of four cycles of adjuvant TMZ. The median overall survival was 14.4 months, and the median disease-free survival was 7.7 months. The median survival time differed significantly between patients who underwent biopsy and those who underwent partial or total resection (7.1 vs. 16.1 months, p = 0.035). The median survival was also significantly different between patients with methylated vs. unmethylated 0-6-methylguanine-DNA methyltransferase promoters (14.4 vs. 8.7 months, p = 0.049). The pattern of failure was predominantly central, within 2 cm of the initial gross tumor volume. Grade 3-4 toxicity was limited to 1 patient with nausea and emesis during adjuvant TMZ administration. Conclusion: The results of our study have shown that hypo-IMRT with concomitant and adjuvant TMZ is well tolerated with a useful 2-week shortening of radiotherapy. Despite a high number of patients with poor prognostic features (74.3% recursive partitioning analysis class V or VI), the median survival was comparable to that after standard radiotherapy fractionation schedules plus TMZ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Analysis of the Safety of Proton Beam Therapy for Unresectable Hepatocellular Carcinoma

Purpose: To evaluate the safety and efficacy of radiotherapy using proton beam (PRT) for unresectable hepatocellular carcinoma. Methods and Materials: Sixty consecutive patients who underwent PRT between May 1999 and July 2007 were analyzed. There were 42 males and 18 females, with a median age of 70 years (48-92 years). All but 1 patient had a single lesion with a median diameter of 45 mm (20-100 mm). Total PRT dose/fractionation was 76-cobalt Gray equivalent (CGE)/20 fractions in 46 patients, 65 CGE/26 fractions in 11 patients, and 60 CGE/10 fractions in 3 patients. The risk of developing proton-induced hepatic insufficiency (PHI) was estimated using dose-volume histograms and an indocyanine-green retention rate at 15 minutes (ICG R15). Results: None of the 20 patients with ICG R15 of less than 20% developed PHI, whereas 6 of 8 patients with ICG R15 values of 50% or higher developed PHI. Among 32 patients whose ICG R15 ranged from 20% to 49.9%, PHI was observed only in patients who had received 30 CGE (V30) to more than 25% of the noncancerous parts of the liver (n = 5) Local progression-free and overall survival rates at 3 years were 90% (95% confidence interval [CI], 80-99%) and 56% (95% CI, 43-69%), respectively. A gastrointestinal toxicity of Grade {>=}2 was observed in 3 patients. Conclusions: ICG R15 and V30 are recommended as useful predictors for the risk of developing PHI, which should be incorporated into multidisciplinary treatment plans for patients with this disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the safety and pharmacodynamics of human fibrinogen concentrate in animals

Fibrinogen, a soluble 340 kDa plasma glycoprotein, is critical in achieving and maintaining hemostasis. Reduced fibrinogen levels are associated with an increased risk of bleeding and recent research has investigated the efficacy of fibrinogen concentrate for controlling perioperative bleeding. European guidelines on the management of perioperative bleeding recommend the use of fibrinogen concentrate if significant bleeding is accompanied by plasma fibrinogen levels less than 1.5–2.0 g/l. Plasma-derived human fibrinogen concentrate has been available for therapeutic use since 1956. The overall aim of the comprehensive series of non-clinical investigations presented was to evaluate i) the pharmacodynamic and pharmacokinetic characteristics and ii) the safety and tolerability profile of human fibrinogen concentrate Haemocomplettan P® (RiaSTAP®). Pharmacodynamic characteristics were assessed in rabbits, pharmacokinetic parameters were determined in rabbits and rats and a safety pharmacology study was performed in beagle dogs. Additional toxicology tests included: single-dose toxicity tests in mice and rats; local tolerance tests in rabbits; and neoantigenicity tests in rabbits and guinea pigs following the introduction of pasteurization in the manufacturing process. Human fibrinogen concentrate was shown to be pharmacodynamically active in rabbits and dogs and well tolerated, with no adverse events and no influence on circulation, respiration or hematological parameters in rabbits, mice, rats and dogs. In these non-clinical investigations, human fibrinogen concentrate showed a good safety profile. This data adds to the safety information available to date, strengthening the current body of knowledge regarding this hemostatic agent. - Highlights: • A comprehensive series of pre-clinical investigations of human fibrinogen concentrate. • Human fibrinogen concentrate was shown to be pharmacodynamically active. • Human fibrinogen concentrate was well tolerated, with no adverse events. • Overall, human fibrinogen concentrate demonstrated a good safety profile. • This data adds to the safety information available to date on this hemostatic agent.

60 APPLIED LIFE SCIENCES↗

Simulation study of the effects of near- and far-field heating during focused ultrasound uterine fibroid ablation using an electronically focused phased array: A theoretical analysis of patient safety

Purpose: Assess the feasibility of using large-aperture, flat ultrasonic transducer arrays with 6500 small elements operating at 500 kHz without the use of any mechanical components for the thermal coagulation of uterine fibroids. This study examines the benefits and detriments of using a frequency that is significantly lower than that used in clinical systems (1–1.5 MHz). Methods: Ultrasound simulations were performed using the anatomies of five fibroid patients derived from 3D MRI. Using electronic steering solely, the ultrasound focus from a flat, 6500-element phased array was translated around the volume of the fibroids in various patterns to assess the feasibility of completing full treatments from fixed physical locations. Successive temperature maps were generated by numerically solving the bioheat equation. Using a thermal dose model, the bioeffects of these simulations were quantified and analyzed. Results: The simulations indicate that such an array could be used to perform fibroid treatments to 18 EM{sub 43} at an average rate of 90 ± 20 cm{sup 3}/h without physically moving the transducer array. On average, the maximum near-field thermal dose for each patient was below 4 EM{sub 43}. Fibroid tissue could be treated as close as 40 mm to the spine without reaching temperatures expected to cause pain or damage. Conclusions: Fibroids were successfully targeted and treated from a single transducer position to acceptable extents and without causing damage in the near- or far-field. Compared to clinical systems, treatment rates were good. The proposed treatment paradigm is a promising alternative to existing systems and warrants further investigation.

60 APPLIED LIFE SCIENCES↗

Atmospheric lidar multi-user instrument system definition study

A spaceborne lidar system for atmospheric studies was defined. The primary input was the Science Objectives Experiment Description and Evolutionary Flow Document. The first task of the study was to perform an experiment evolutionary analysis of the SEED. The second task was the system definition effort of the instrument system. The third task was the generation of a program plan for the hardware phase. The fourth task was the supporting studies which included a Shuttle deficiency analysis, a preliminary safety hazard analysis, the identification of long lead items, and development studies required. As a result of the study an evolutionary Lidar Multi-User Instrument System (MUIS) was defined. The MUIS occupies a full Spacelab pallet and has a weight of 1300 kg. The Lidar MUIS laser provides a 2 joule frequency doubled Nd:YAG laser that can also pump a tuneable dye laser wide frequency range and bandwidth. The MUIS includes a 1.25 meter diameter aperture Cassegrain receiver, with a moveable secondary mirror to provide precise alignment with the laser. The receiver can transmit the return signal to three single and multiple photomultiple tube detectors by use of a rotating fold mirror. It is concluded that the Lidar MUIS proceed to program implementation.

Greco, R. V.↗

Probabilistic Causal Analysis for System Safety Risk Assessments in Commercial Air Transport

Aviation is one of the critical modes of our national transportation system. As such, it is essential that new technologies be continually developed to ensure that a safe mode of transportation becomes even safer in the future. The NASA Aviation Safety Program (AvSP) is managing the development of new technologies and interventions aimed at reducing the fatal aviation accident rate by a factor of 5 by year 2007 and by a factor of 10 by year 2022. A portfolio assessment is currently being conducted to determine the projected impact that the new technologies and/or interventions may have on reducing aviation safety system risk. This paper reports on advanced risk analytics that combine the use of a human error taxonomy, probabilistic Bayesian Belief Networks, and case-based scenarios to assess a relative risk intensity metric. A sample case is used for illustrative purposes.

Luxhoj, James T.↗

Preliminary Recommendations for the Collection, Storage, and Analysis of UAS Safety Data

Although the use of UASs in military and public service operations is proliferating, civilian use of UASs remains limited in the United States today. With efforts underway to accommodate and integrate UASs into the NAS, a proactive understanding of safety issues, i.e., the unique hazards and the corresponding risks that UASs pose not only through their operations for commercial purposes, but also to existing operations in the NAS, is especially important so as to (a) support the development of a sound regulatory basis, (b) regulate, design and properly equip UASs, and (c) effectively mitigate the risks posed. Data, especially about system and component failures, incidents, and accidents, provides valuable insight into how performance and operational capabilities/limitations contribute to hazards. Since the majority of UAS operations today take place in a context that is significantly different from the norm in civil aviation, i.e., with different operational goals and standards, identifying that which constitutes useful and sufficient data on UASs and their operations is a substantial research challenge.

Safety Data↗

Probabilistic Analysis of Passive Safety System Reliability in Advanced Small Modular Reactors: Methodologies and Lessons Learned

Many advanced small modular reactor designs rely on passive systems to fulfill safety functions during accident sequences. These systems depend heavily on boundary conditions to induce a motive force, meaning the system can fail to operate as intended due to deviations in boundary conditions, rather than as the result of physical failures. Furthermore, passive systems may operate in intermediate or degraded modes. These factors make passive system operation difficult to characterize with a traditional probabilistic framework that only recognizes discrete operating modes and does not allow for the explicit consideration of time-dependent boundary conditions. Argonne National Laboratory has been examining various methodologies for assessing passive system reliability within a probabilistic risk assessment for a station blackout event at an advanced small modular reactor. This paper describes the most promising options: mechanistic techniques, which share qualities with conventional probabilistic methods, and simulation-based techniques, which explicitly account for time-dependent processes. The primary intention of this paper is to describe the strengths and weaknesses of each methodology and highlight the lessons learned while applying the two techniques while providing high-level results. This includes the global benefits and deficiencies of the methods and practical problems encountered during the implementation of each technique.

Grabaskas, David↗