Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Total cross sections for photoabsorption on light nuclei in the energy range 600-1500 MeV

Experimental data of the GRAAL Collaboration on the total cross sections for photoabsorption on deuterium and carbon targets at gamma-ray energies in the range between 600 and 1500 MeV are presented. The experiment was performed in a beam of photons obtained by the method of the Compton backscattering of laser photons at the electron storage ring of the European Synchrotron Radiation Facility (ESRF, Grenoble, France) by using a wide-aperture detector covering a solid angle close to 4{pi}. The total photoabsorption cross sections were determined by two independent methods: by subtracting the emptytarget background and by summing partial cross sections for meson photoproduction. The total cross sections for photoabsorption on quasifree protons and neutrons are shown to agree both in magnitude and in shape within a 5% precision of the measurements. In contrast to data previously available in the literature, both cross sections show distinctly the F{sub 15}(1680) resonance at a photon energy of about 1 GeV. Data obtained in the present experiment for the cross sections for photoabsorption on a free and a bound nucleon are compared. This comparison reveals a substantial role of two-nucleon correlations in estimating the nuclear-medium effect on meson photoproduction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of e{sup +}e{sup -}{yields}{rho}{sup +}{rho}{sup -} near {radical}(s)=10.58 GeV

We report the first observation of e{sup +}e{sup -}{yields}{rho}{sup +}{rho}{sup -}, in a data sample of 379 fb{sup -1} collected with the BABAR detector at the PEP-II e{sup +}e{sup -} storage ring at center-of-mass energies near {radical}(s)=10.58 GeV. We measure a cross section of {sigma}(e{sup +}e{sup -}{yields}{rho}{sup +}{rho}{sup -})=8.3{+-}0.7(stat){+-}0.8(syst) fb within the range of |cos{theta}*|<0.8 and |cos{theta}{sub {+-}}|<0.85, where {theta}* is the center-of-mass polar angle of the {rho}{sup {+-}} meson and {theta}{sub {+-}} are the angles in the {rho}{sup {+-}} rest frame between the direction of the boost from the laboratory frame and the direction of the {pi}{sup {+-}}. Assuming production through single-photon annihilation, there are three independent helicity amplitudes. We measure the ratios of their squared moduli to be |F{sub 00}|{sup 2} ratio |F{sub 10}|{sup 2} ratio |F{sub 11}|{sup 2}= 0.51{+-}0.14(stat){+-}0.07(syst) ratio 0.10{+-}0.04(stat){+-}0.01(syst) ratio 0.04{+-}0.03(stat){+-}0.01(syst). The |F{sub 00}|{sup 2} result is inconsistent with the prediction of 1.0 made by QCD models with a significance of 3.1 standard deviations including systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of hadronic transitions between {upsilon} states and observation of {upsilon}(4S){yields}{eta}{upsilon}(1S) decay

We present a study of hadronic transitions between {upsilon}(mS) (m=4, 3, 2) and {upsilon}(nS) (n=2, 1) resonances based on 347.5 fb{sup -1} of data taken with the BABAR detector at the PEP-II storage rings. We report the first observation of {upsilon}(4S){yields}{eta}{upsilon}(1S) decay with a branching fraction B({upsilon}(4S){yields}{eta}{upsilon}(1S))=(1.96{+-}0.06{sub stat}{+-}0.09{sub syst})x10{sup -4} and measure the ratio of partial widths {gamma}({upsilon}(4S){yields}{eta}{upsilon}(1S))/{gamma}({upsilon}(4S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(1S))=2.41{+-}0.40{sub stat}{+-}0.12{sub syst}. We set 90% CL upper limits on the ratios {gamma}({upsilon}(2S){yields}{eta}{upsilon}(1S))/{gamma}({upsilon}(2S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(1S))<5.2x10{sup -3} and {gamma}({upsilon}(3S){yields}{eta}{upsilon}(1S))/{gamma}({upsilon}(3S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(1S))<1.9x10{sup -2}. We also present new measurements of the ratios {gamma}({upsilon}(4S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(2S))/{gamma}({upsilon}(4S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(1S))=1.16{+-}0.16{sub stat}{+-}0.14{sub syst} and {gamma}({upsilon}(3S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(2S))/{gamma}({upsilon}(3S){yields}{pi}{sup +}{pi}{sup -}{upsilon}(1S))=0.577{+-}0.026{sub stat}{+-}0.060{sub syst}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Bbar to Xu l nubar Decays in BBbar Events Tagged by a Fully Reconstructed B-meson Decay and Determination of |V_{ub}|

We report measurements of partial branching fractions for inclusive charmless semileptonic B decays {bar B} {yields} X{sub u}{ell}{bar {nu}}, and the determination of the CKM matrix element |V{sub ub}|. The analysis is based on a sample of 467 million {Upsilon}(4S) {yields} B{bar B} decays recorded with the BABAR detector at the PEP-II e{sup +}e{sup -} storage rings. We select events in which the decay of one of the B mesons is fully reconstructed and an electron or a muon signals the semileptonic decay of the other B meson. We measure partial branching fractions {Delta}{Beta} in several restricted regions of phase space and determine the CKM element |V{sub ub}| based on four different QCD predictions. For decays with a charged lepton momentum p*{sub {ell}} > 1.0 GeV in the B meson rest frame, we obtain {Delta}{Beta} = (1.80 {+-} 0.13{sub stat.} {+-} 0.15{sub sys.} {+-} 0.02{sub theo.}) x 10{sup -3} from a maximum likelihood fit to the two-dimensional M{sub X} - q{sup 2} distribution. Here, M{sub X} refers to the invariant mass of the final state hadron X and q{sup 2} is the invariant mass squared of the charged lepton and neutrino. From this measurement we extract |V{sub ub}| = (4.31 {+-} 0.25{sub exp.} {+-} 0.16{sub theo.}) x 10{sup -3} as the arithmetic average of four results obtained from four different QCD predictions of the partial rate. We separately determine partial branching fractions for {bar B}{sup 0} and B{sup -} decays and derive a limit on the isospin breaking in {bar B} {yields} X{sub u}{ell}{bar {nu}} decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inclusive radiative J/{psi} decays

Using data taken with the CLEO-c detector at the Cornell Electron Storage Ring, we have investigated the direct-photon momentum spectrum in the decay J/{psi}(1S){yields}{gamma}gg, via the ''tagged'' process: e{sup +}e{sup -}{yields}{psi}(2S); {psi}(2S){yields}J/{psi}{pi}{sup +}{pi}{sup -}; J/{psi}{yields}{gamma}+X. Including contributions from two-body radiative decay processes, we find the ratio of the inclusive direct-photon branching fraction to that of the dominant three-gluon branching fraction [R{sub {gamma}}=B(gg{gamma})/B(ggg)] to be R{sub {gamma}}=0.137{+-}0.001{+-}0.016{+-}0.004, where the errors shown are statistical, systematic, and the model-dependent uncertainty related to the extrapolation to zero photon energy. The shape of the scaled photon energy spectrum in J/{psi}{yields}gg{gamma} is observed to be very similar to that of {upsilon}{yields}gg{gamma}. The R{sub {gamma}} value obtained is roughly consistent with that expected by a simple quark-charge scaling [R{sub {gamma}}{approx}(q{sub c}/q{sub b}){sup 2}] of the value determined at the {upsilon}(1S), but somewhat higher than the value expected from the running of the strong coupling constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗

SU-E-J-21: Advantages of Ultra Fast Radiation Dose Delivering

Purpose: For delivering conformed dose to a moving tumor and sparing normal tissue, we presented an innovation that was combined a linear accelerator and a storage ring to generate ultra high dose rate. This innovation allows delivering prescribed dose to a moving target in such a short time period, for an example 0.1 second, during which the displacement of the target could be ignored. Methods: The advantages of this approach were evaluated based on normal tissue sparing, feasibility, accuracy, and time saving in clinical treatment. The target volume reduction with this innovation approach was demonstrated by analyzing the values of GTVs, ITVs, and PTVs obtained from 15 patients who had been diagnosed with malignant neoplasm of lung and treated with SBRT. The processes of SBRT treatment were investigated and advantages of this innovation in improving SBRT lung treatment were evaluated. Results: With the ultra-high dose rate, the target volumes could be reduced by ∼30% to 50%. The innovation combining with IGRT technique could deliver prescribed dose to moving target accurately with simpler procedures than that of adaptive approach. This new approach could reduce the time of guiding treatment by many times. The new technique make a new strategy became feasible that was to deliver the dose to a target when it moved to a desirable location, such as away from critical organs. Conclusion: Combining with IGRT technique, this innovation could significantly improve the accuracy to deliver dose to moving targets with a shorter time than conventional techniques. The innovation opens a door for new strategies to deliver dose to moving targets.

60 APPLIED LIFE SCIENCES↗

A panoply of insertion devices at SOLEIL for a wide spectral range and flexible polarisation

The SOLEIL storage ring presents a very high fraction of its circumference dedicated to accommodate Insertion Devices (ID). Over the 25 presently planned insertion devices presenting a large variety of systems, 16 have been already installed and commissioned in September 2009. The UV-VUV region is covered with electromagnetic devices, offering tuneable polarisations. An electromagnet/permanent magnet undulator using copper sheets coils for fast switching of the helicity is under construction. 13 APPLE-II type undulators, with period ranging from 80 down to 36 mm, provide photons in the 0.1-10 keV region, some of them featuring tapering or quasi-periodicity. Five U20 in vacuum undulators cover typically the 3-30 keV range whereas an in vacuum wiggler, with compensation of the magnetic forces via adequate springs will cover the 10-50 keV spectral domain. R and D on cryogenic in-vacuum undulator is also under progress. A magnetic chicane using permanent magnet dipoles has also been designed in order to accommodate two canted undulators on the same straight section. A wiggler dedicated to slicing (production of femto second long pulses) is also being designed, its radiation will also serve for an X-ray beamline.

43 PARTICLE ACCELERATORS↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Measurement of the Hadronic Mass Spectrum in B to Xulnu Decaysand Determination of the b-Quark Mass at the BaBar Experiment

I present preliminary results of the measurement of the hadronic mass spectrum and its first three spectral moments in inclusive charmless semileptonic B-meson decays. The truncated hadronic mass moments are used for the first determination of the b-quark mass and the nonperturbative parameters μ π 2 and ρ D 3 in this B-meson decay channel. The study is based on 383 x 10 6 B$\bar{B}$ decays collected with the BABAR experiment at the PEP-II e + e - storage rings, located at the Stanford Linear Accelerator Center. The first, second central, and third central hadronic mass moment with a cut on the hadronic mass m X 2 < 6.4GeV 2 and the lepton momentum p* > 1 GeV are measured to be: M 1 = (1.96 ± 0.34 stat ± 0.53 syst ) GeV 2 ; U 2 = (1.92 ± 0.59 stat ± 0.87 syst ) GeV 4 ; and U 3 = (1.79 ± 0.62 stat ± 0.78 syst ) GeV 6 ; with correlation coefficients ρ 12 = 0.99, ρ 23 = 0.94, and ρ 13 = 0.88, respectively. Using Heavy Quark Effective Theory-based predictions in the kinetic scheme we extract: m b = (4.60 ± 0.13 stat ± 0.19 syst ± 0.10 theo GeV); μ π 2 = (0.40 ± 0.14 stat ± 0.20 syst ± 0.04 theo ) GeV 2 ; ρ D 3 = (0.10 ± 0.02 stat ± 0.02 syst ± 0.07 theo ) GeV 3 ; at μ = 1 GeV, with correlation coefficients ρ m b μ π 2 = -0.99, ρ μ π 2 ρ D 3 = 0.57, and ρ m b ρ D 3 = -0.59. The results are in good agreement with earlier determinations in inclusive charmed semileptonic and radiative penguin B-meson decays and have a similar accuracy. Through the comparison of this result to those obtained in other channels, this provides a test of the Heavy Quark Effective Theory predictions that are used for the determination of |V ub |. In addition, the measured dependence of the hadronic mass moments on the hadronic mass cut is compared to the dependence predicted by Heavy Quark Effective Theory.

43 PARTICLE ACCELERATORS↗

Assignment of resonances in dissociative recombination of HD{sup +} ions: High-resolution measurements compared with accurate computations

The collision-energy resolved rate coefficient for dissociative recombination of HD{sup +} ions in the vibrational ground state is measured using the photocathode electron target at the heavy-ion storage ring TSR. Rydberg resonances associated with rovibrational excitation of the HD{sup +} core are scanned as a function of the electron collision energy with an instrumental broadening below 1 meV in the low-energy limit. The measurement is compared to calculations using multichannel quantum defect theory, accounting for rotational structure and interactions and considering the six lowest rotational energy levels as initial ionic states. Using thermal-equilibrium-level populations at 300 K to approximate the experimental conditions, close correspondence between calculated and measured structures is found up to the first vibrational excitation threshold of the cations near 0.24 eV. Detailed assignments, including naturally broadened and overlapping Rydberg resonances, are performed for all structures up to 0.024 eV. Resonances from purely rotational excitation of the ion core are found to have similar strengths as those involving vibrational excitation. A dominant low-energy resonance is assigned to contributions from excited rotational states only. The results indicate strong modifications in the energy dependence of the dissociative recombination rate coefficient through the rotational excitation of the parent ions, and underline the need for studies with rotationally cold species to obtain results reflecting low-temperature ionized media.

74 ATOMIC AND MOLECULAR PHYSICS↗

LOW HORIZONTAL BETA FUNCTION IN LONG STRAIGHTS OF THE NSLS-II LATTICE

The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 short straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of maintaining three long straights with large horizontal beta function while providing the other 12 long straights with smaller horizontal beta function to optimize the brightness of insertion devices. Our study considers the possible linear lattice solutions as well as characterizing the nonlinear dynamics. Results are reported on optimization of dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses dynamic aperture optimization for the NSLS-II lattice with alternate high and low horizontal beta function in the long straights, which is proposed for the optimization of the brightness of insertion devices. The linear optics is optimized to meet the requirements of lattice function and source properties. Nonlinear optimization for a lattice with working point at (37.18, 16.2) is performed. Considering the realistic magnets errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the lattice with high-low beta function has adequate dynamic aperture for good injection efficiency and sufficient Touschek lifetime.

43 PARTICLE ACCELERATORS↗

Exclusive Branching-Fraction Measurements of Semileptonic {tau} Decays into Three Charged Hadrons, into {phi}{pi}{sup -}{nu}{sub {tau}}, and into {phi}K{sup -}{nu}{sub {tau}}

Using a data sample corresponding to an integrated luminosity of 342 fb{sup -1} collected with the BABAR detector at the SLAC PEP-II electron-positron storage ring operating at a center-of-mass energy near 10.58 GeV, we measure B({tau}{sup -}{yields}{pi}{sup -}{pi}{sup -}{pi}{sup +}{nu}{sub {tau}}(ex.K{sub S}{sup 0}))=(8.83{+-}0.01{+-}0.13)%, B({tau}{sup -}{yields}K{sup -}{pi}{sup -}{pi}{sup +}{nu}{sub {tau}}(ex.K{sub S}{sup 0}))=(0.273{+-}0.002{+-}0.009)%, B({tau}{sup -}{yields}K{sup -}{pi}{sup -}K{sup +}{nu}{sub {tau}})=(0.1346{+-}0.0010{+-}0.0036)%, and B({tau}{sup -}{yields}K{sup -}K{sup -}K{sup +}{nu}{sub {tau}})=(1.58{+-}0.13{+-}0.12)x10{sup -5}, where the uncertainties are statistical and systematic, respectively. These include significant improvements over previous measurements and a first measurement of B({tau}{sup -}{yields}K{sup -}K{sup -}K{sup +}{nu}{sub {tau}}) in which no resonance structure is assumed. We also report a first measurement of B({tau}{sup -}{yields}{phi}{pi}{sup -}{nu}{sub {tau}})=(3.42{+-}0.55{+-}0.25)x10{sup -5}, a new measurement of B({tau}{sup -}{yields}{phi}K{sup -}{nu}{sub {tau}})=(3.39{+-}0.20{+-}0.28)x10{sup -5} and a first upper limit on B({tau}{sup -}{yields}K{sup -}K{sup -}K{sup +}{nu}{sub {tau}}(ex.{phi}))

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of excited charm-strange baryons with evidence for new baryons {xi}{sub c}(3055){sup +} and {xi}{sub c}(3123){sup +}

We present a study of excited charm-strange baryon states produced in e{sup +}e{sup -} annihilations at or near a center-of-mass energy of 10.58 GeV, in a data sample with an integrated luminosity of 384 fb{sup -1} recorded with the BABAR detector at the PEP-II e{sup +}e{sup -} storage rings at the Stanford Linear Accelerator Center. We study strong decays of charm-strange baryons to {lambda}{sub c}{sup +}K{sub S}{sup 0}, {lambda}{sub c}{sup +}K{sup -}, {lambda}{sub c}{sup +}K{sup -}{pi}{sup +}, {lambda}{sub c}{sup +}K{sub S}{sup 0}{pi}{sup -}, {lambda}{sub c}{sup +}K{sub S}{sup 0}{pi}{sup -}{pi}{sup +}, and {lambda}{sub c}{sup +}K{sup -}{pi}{sup +}{pi}{sup -}. This study confirms the existence of the states {xi}{sub c}(2980){sup +}, {xi}{sub c}(3077){sup +}, and {xi}{sub c}(3077){sup 0}, with a more accurate determination of the {xi}{sub c}(2980){sup +} mass and width. We also present evidence for two new states, {xi}{sub c}(3055){sup +} and {xi}{sub c}(3123){sup +}, decaying through the intermediate-resonant modes {sigma}{sub c}(2455){sup ++}K{sup -} and {sigma}{sub c}(2520){sup ++}K{sup -}, respectively. For each of these baryons, we measure the yield in each final state, determine the statistical significance, and calculate the product of the production cross section and branching fractions. We also measure the masses and widths of these excited charm-strange baryons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrafast X-ray Sources

Since before the scattering of X-rays off of DNA led to the first understanding of the double helix structure, sources of X-rays have been an essential tool for scientists examining the structure and interactions of matter. The resolution of a microscope is proportional to the wavelength of light so x-rays can see much finer structures than visible light, down to single atoms. In addition, the energy of X-rays is resonant with the core atomic levels of atoms so with appropriate wavelengths the placement of specific atoms in a large molecule can be determined. Over 10,000 scientists use synchrotron sources, storage rings of high energy electrons, each year worldwide. As an example of such use, virtually every picture of a protein or drug molecule that one sees in the scientific press is a reconstruction based on X-ray scattering of synchrotron light from the crystallized form of that molecule. Unfortunately those pictures are static and proteins work through configuration (shape) changes in response to energy transfer. To understand how biological systems work requires following the energy flow to these molecules and tracking how shape changes drive their interaction with other molecules. We'd like to be able to freeze the action of these molecules at various steps along the way with an X-ray strobe light. How fast does it have to be? To actually get a picture of a molecule in a fixed configuration requires X-ray pulses as short as 30 femtoseconds (1/30 of a millionth of a millionth of a second). To capture the energy flow through changes in electronic levels requires a faster strobe, less than 1 femtosecond! And to acquire such information in smaller samples with higher accuracy demands brighter and brighter X-rays. Unfortunately modern synchrotrons (dubbed 3rd Generation Light Sources) cannot deliver such short bright pulses of X-rays. An entirely new approach is required, linear-accelerator (linac-)-based light sources termed 4th or Next Generation Light Sources (NGLSs). Although NGLSs will not displace synchrotrons from their role they do offer exciting new capabilities which can be understood from the physics of the light production in each device.

43 PARTICLE ACCELERATORS↗

ADDITIONAL QUADRUPOLES AT CENTER OF LONG STRAIGHTS IN THE NSLS-II LATTICE

The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 shorter straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of installing additional quadrupoles at the center of selected long straight sections in order to provide two low-beta source locations for undulators in the same straight. The required modification to the linear lattice is discussed as well as the preservation of adequate dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses the possibility of producing two low-beta source locations for optimum brightness of undulators in the long straights of NSLS-II lattice by installing additional quadrupoles at the center. The linear optics is optimized to satisfy the requirements of lattice function and properties. Nonlinear optimization for a lattice with working point at (37.16, 17.22) is performed. Considering the magnets misalignment errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the modified high-low beta function lattice can achieve a modest dynamic aperture in this preliminary study. Further work will continue to expand the dynamic aperture to meet the requirement of good injection efficiency and sufficient Touschek lifetime.

43 PARTICLE ACCELERATORS↗

Magnetic Field Mapping and Integral Transfer Function Matching of the Prototype Dipoles for the NSLS-II at BNL

The National Synchrotron Light Source-II (NSLS-II) storage ring at Brookhaven National Laboratory (BNL) will be equipped with 54 dipole magnets having a gap of 35 mm, and 6 dipoles having a gap of 90 mm. Each dipole has a field of 0.4 T and provides 6 degrees of bending for a 3 GeV electron beam. The large aperture magnets are necessary to allow the extraction of long-wavelength light from the dipole magnet to serve a growing number of users of low energy radiation. The dipoles must not only have good field homogeneity (0.015% over a 40 mm x 20 mm region), but the integral transfer functions and integral end harmonics of the two types of magnets must also be matched. The 35 mm aperture dipole has a novel design where the yoke ends are extended up to the outside dimension of the coil using magnetic steel nose pieces. This design increases the effective length of the dipole without increasing the physical length. These nose pieces can be tailored to adjust the integral transfer function as well as the homogeneity of the integrated field. One prototype of each dipole type has been fabricated to validate the designs and to study matching of the two dipoles. A Hall probe mapping system has been built with three Group 3 Hall probes mounted on a 2-D translation stage. The probes are arranged with one probe in the midplane of the magnet and the others vertically offset by {+-}10 mm. The field is mapped around a nominal 25 m radius beam trajectory. The results of measurements in the as-received magnets, and with modifications made to the nose pieces are presented.

43 PARTICLE ACCELERATORS↗