Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STAINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Combined Imaging and RNA-Seq on a Microfluidic Platform for Viral Infection Studies

The goal of this work was to pioneer a novel, low-overhead protocol for simultaneously assaying cell-surface markers and intracellular gene expression in a single mammalian cell. The purpose of developing such a method is to be able to understand the mechanisms by which pathogens engage with individual mammalian cells, depending on their cell surface proteins, and how both host and pathogen gene expression changes are reflective of these mechanisms. The knowledge gained from such analyses of single cells will ultimately lead to more robust pathogen detection and countermeasures. Our method was aimed at streamlining both the upstream cell sample preparation using microfluidic methods, as well as the actual library making protocol. Specifically, we wanted to implement a random hexamer-based reverse transcription of all RNA within a single cell (as opposed to oligo dT-based which would only capture polyadenylated transcripts), and then use a CRISPR-based method called scDash to deplete ribosomal DNAs (since ribosomal RNAs make up the majority of the RNA in a mammalian cell). After significant troubleshooting, we demonstrate that we are able to prepare cDNA from RNA using the random hexamer primer, and perform the rDNA depletion. We also show that we can visualize individually stained cells, setting up the pipeline for connecting surface markers to RNA-sequencing profiles. Finally, we test a number of devices for various parts of the pipeline, including bead generation, optical barcoding and cell dispensing, and demonstrate that while some of these have potential, more work is needed to optimize this part of the pipeline.

59 BASIC BIOLOGICAL SCIENCES↗

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

Harnessing Biomineralization Potential of Metal-Sequestering Bacteria for Rare Earth Elements (REE) Material Synthesis

Extremophilic methylotrophs, such as Methylotuvimicrobium alcaliphilum 20ZR are known for their natural ability to carry out REE capture and uptake. It has been predicted that proteins associated with surface layers facilitate transport and homeostasis of essential metals. Indeed, electron microscopic analysis coupled with antibody staining revealed that cell envelop of metal-grown M. alcaliphilum 20ZR contains metal-binding proteins in the base of the cup-shaped structures of S-layers. While less explored, the proteins associated with S-layers are also predicted to contribute to scavenging of other minerals essential for core metabolism. Here, we employed bottom-up proteomic study to compare the protein content of S-layer fractions of M. alcaliphilum 20ZR cultures grown in the presence and absence trace metals to identify putative components REE-scavenging machinery.

36 MATERIALS SCIENCE↗

Sensing Modalities Deployed - Acoustic

Acoustic approaches to OLM are based on analyzing changes in various forms of pressure waves propagating in solids, fluids or gases. These pressure waves can vary in frequency content from infrasound (seismic events) to the megahertz region (acoustic emissions). A wide variety of commercially available pressure or stain sensing devices are used to make acoustic measurements. These sensors differ in the transduction mechanism used to convert the pressure or strain signal to an electrical output, the sensitivity, dynamic range, bandwidth, directional characteristics, and physical size. All acoustic sensors must be integrated with signal conditioning electronics to convert the sensors’ analog output to discrete digital signals that can then be further analyzed for OLM. Ultimately, the sensing properties listed above will be a function of the sensor transduction mechanism, the sensor design and the conditioning electronics.

47 OTHER INSTRUMENTATION↗

Alternate Methods for Cleaning Zirconium Plate

The United States High Performance Research Reactor Conversion Program identified the need to transition from highly enriched uranium fuel to lowly enriched uranium fuel for high power research and civil reactors. One of the fuel configurations selected for these reactors was a uranium (U) foil alloyed with 10% molybdenum (Mo). The U-10Mo fuel foil was then covered with a zirconium (Zr) interlayer and pressed into an aluminum cladding. Idaho National Laboratory prescribed a need to remove surface oxidation on the Zr prior to bonding it with U-10Mo fuel foil. To determine the best method of oxidation removal, a variety of polishing methods, including hand polishing with a diamond paste or Scotch-Brite™ pads, mechanically wet-polishing with abrasive belts, and chemical etching with hydrofluoric/nitric acid mixtures, were investigated on pre-polished Zircaloy 702 sheets purchased directly from the manufacturer. No change in surface roughness was detected using any of these methods relative to the as-received material. In fact, scanning electron microscopy detected grit from hand polishing with Amplex Grade 30 waste soluble diamond paste and Scotch-Brite™ pads. Visible staining was found, and fluorine detected via X-ray photoelectron spectroscopy on the flash etching samples. These contaminants were not seen on the as-received material. In addition to the need to remove the oxide layer on the Zr prior to co-rolling, there are concerns that the Neolube debonding agent on the co-rolling can may contaminate the Zr surface after co-rolling. The experimental results found that zirconium in contact with Neolube coated steel plates was easily cleaning with ethanol wiping after heat treated and no carbide inclusions remained on the surface. Overall, all cleaning methods tested did not significantly change the surface roughness of the plates or reduce the oxide layer present on the zirconium. Carbon was found on all the samples, before and after cleaning, except for the flash etch samples which detected fluorine instead. The insignificant changes seen in the cleaned plates relative to the as received plates question the need for cleaning prior to rolling. Further investigation in the requirements for cleaning at this step is recommended. Current methods for cleaning the surface after hot rolling with alcohol appear sufficient. After hot rolling, if Neolube does peel off the can and onto the zirconium coated foil surface, a dry abrasive or diamond paste polish is not recommended due to the chance of abrasive being embedded into the surface. However, the ability of an etchant to lift the lubricant off the zirconium surface indicates that a spot etch method could work to clean specific spots where Neolube is present, if the need arises.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Strain in the Vadose Zone During Sinusoidal-Rate Well Tests to Characterize an Aquifer

Well tests with sinusoidal variation in pumping rate are appealing because of the ability to filter competing signals and they also can be set up with no net removal of water, which is an advantage at contaminated sites. Current methods of interpreting sinusoidal-rate well tests analyze the phase lag and amplitude of pressure signals in the aquifer. This approach is restricted by the availability of monitoring wells. An alternative approach could be to measure the stain in the vadose zone instead of pressure in the aquifer. The goal of this research is to evaluate the feasibility of using signals from in-situ sensors in the vadose zone to characterize sinusoidal-rate well tests. Well tests with a variety of periods and amplitudes were performed using a well completed in an unconfined saprolite aquifer with a water table at 9m depth at our test site near Clemson, South Carolina. Vertical strain was measured every meter between 1 to 7 m using a distributed optical fiber sensing technique called coherence length gated microwave photonics interferometry (CMPI). A novel packaging system was designed to couple the optical fiber to the saprolite. The results show that strain measured in the vadose zone during sinusoidal-rate pumping varies periodically with amplitudes from 0.1 to 3 microstrain, depending on the amplitude of the sinusoidal pumping rate. Hydraulic heads at similar radial distances were also periodic with changing amplitudes ranging up to ±0.2 meters. The strain in the vadose zone responds to pressure in the underlying aquifer—the strain is tensile when the pressure is falling, and compressive when the pressure is rising. The phase lag between the pumping rate and the strain was 3 min with a pumping period of 15 minutes, and this gives a hydraulic diffusivity of 0.06 m2/s. This is the same diffusivity obtained by analyzing a constant rate pumping test, and it is slightly larger than the diffusivity (0.044 m2/s) obtained by analyzing the phase lag of the pressure in a nearby monitoring well. Strain measurements in the vadose zone could be made with much less cost and effort than installing a deep monitoring well. These results suggest that strain measurements in the vadose zone could be used to supplement monitoring wells, thereby increasing the resolution, and reducing costs of analyzing well tests.

well test, sinusoidal, periodic pumping, strain↗

TEAMER Technical Support on Biofouling and Corrosion for E-Wave Technologies LLC Novel (Abstract)

National Technology & Engineering Solutions of Sandia (NTESS) in collaboration with the Pacific Northwest National Laboratory (PNNL), and with guidance from E-Wave, will assess corrosion and biofouling challenges specific to E-Wave’s innovative WEC designed to retrofit into and power existing aquaculture farm infrastructure from ocean waves. The teams will examine coatings via a static raw seawater test and determine the efficacy of coatings for E-Wave’s applications. Samples will include panels of materials provided by E-Wave and coated with three different paint treatments. Fouling will be determined using a staining technique followed by photographic analysis to evaluate fouling intensity on the surface. Materials will also be weighed before and after submersion to facilitate weight change analysis resulting from fouling organisms aggregating on the materials.

16 TIDAL AND WAVE POWER↗

Corrective Action Decision Document for Corrective Action Unit 563: Septic Systems, Nevada Test Site, Nevada, Revision 0

This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 563, Septic Systems, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996; as amended January 2007). The corrective action sites (CASs) for CAU 563 are located in Areas 3 and 12 of the Nevada Test Site, Nevada, and are comprised of the following four sites: •03-04-02, Area 3 Subdock Septic Tank •03-59-05, Area 3 Subdock Cesspool •12-59-01, Drilling/Welding Shop Septic Tanks •12-60-01, Drilling/Welding Shop Outfalls The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative (CAA) for the four CASs within CAU 563. Corrective action investigation (CAI) activities were performed from July 17 through November 19, 2007, as set forth in the CAU 563 Corrective Action Investigation Plan (NNSA/NSO, 2007). Analytes detected during the CAI were evaluated against appropriate final action levels (FALs) to identify the contaminants of concern (COCs) for each CAS. The results of the CAI identified COCs at one of the four CASs in CAU 563 and required the evaluation of CAAs. Assessment of the data generated from investigation activities conducted at CAU 563 revealed the following: •CASs 03-04-02, 03-59-05, and 12-60-01 do not contain contamination at concentrations exceeding the FALs. •CAS 12-59-01 contains arsenic and chromium contamination above FALs in surface and near-surface soils surrounding a stained location within the site. Based on the evaluation of analytical data from the CAI, review of future and current operations at CAS 12-59-01, and the detailed and comparative analysis of the potential CAAs, the following corrective actions are recommended for CAU 563.

Evenson, Grant↗

Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 134: Aboveground Storage Tanks, Nevada Test Site, Nevada

This Streamlined Approach for Environmental Restoration (SAFER) Plan identifies the activities required for the closure of Corrective Action Unit (CAU) 134, Aboveground Storage Tanks. CAU 134 is currently listed in Appendix III of the Federal Facility Agreement and Consent Order (FFACO) (FFACO, 1996; as amended February 2008) and consists of four Corrective Action Sites (CASs) located in Areas 3, 15, and 29 of the Nevada Test Site (NTS) (Figure 1): (1) CAS 03-01-03, Aboveground Storage Tank; (2) CAS 03-01-04, Tank; (3) CAS 15-01-05, Aboveground Storage Tank; and (4) CAS 29-01-01, Hydrocarbon Stain. CAS 03-01-03 consists of a mud tank that is located at the intersection of the 3-07 and the 3-12 Roads in Area 3 of the NTS. The tank and its contents are uncontaminated and will be dispositioned in accordance with applicable federal, state, and local regulations. This CAS will be closed by taking no further action. CAS 03-01-04 consists of a potable water tank that is located at the Core Complex in Area 3 of the NTS. The tank will be closed by taking no further action. CAS 15-01-05 consists of an aboveground storage tank (AST) and associated impacted soil, if any. This CAS is located on a steep slope near the Climax Mine in Area 15 of the NTS. The AST is empty and will be dispositioned in accordance with applicable federal, state, and local regulations. Soil below the AST will be sampled to identify whether it has been impacted by chemicals at concentrations exceeding the action levels. It appears that the tank is not at its original location. Soil will also be sampled at the original tank location, if it can be found. If soil at either location has been impacted at concentrations that exceed the action levels, then the extent of contamination will be identified and a use restriction (UR) will be implemented. The site may be clean closed if contamination is less than one cubic yard in extent and can be readily excavated. If action levels are not exceeded, then no further action is required. CAS 29-01-01 consists of soil that has been impacted by a release or operations from an active diesel AST that fuels the generator at the Shoshone Receiver Site in Area 29 of the NTS. Soil below the AST will be sampled to identify whether it has been impacted at concentrations exceeding the action levels. If it is, then the extent of contamination will be identified and a UR will be implemented. The site may be clean closed if contamination is less than one cubic yard in extent, can be readily excavated, and it is determined that clean closure is feasible based upon site conditions. If action levels are not exceeded, then no further action is required. Based on review of the preliminary assessment information for CAU 134 and recent site inspections, there is sufficient process knowledge to close CAU 134 using the SAFER process.

54 ENVIRONMENTAL SCIENCES↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 130: Storage Tanks, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 130, Storage Tanks, identified in the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended February 2008). Corrective Action Unit 130 consists of the seven following corrective action sites (CASs) located in Areas 1, 7, 10, 20, 22, and 23 of the Nevada Test Site: • 01-02-01, Underground Storage Tank • 07-02-01, Underground Storage Tanks • 10-02-01, Underground Storage Tank • 20-02-03, Underground Storage Tank • 20-99-05, Tar Residue • 22-02-02, Buried UST Piping • 23-02-07, Underground Storage Tank This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 130 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation that no further corrective action is necessary. This will be presented in a Closure Report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The sites will be investigated based on the data quality objectives (DQOs) finalized on April 3, 2008, by representatives of NDEP; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 130. The DQO process developed for this CAU identified the following expected closure options: (1) investigation and confirmation that no contamination exists above the final action levels, leading to a no further action declaration; (2) characterization of the nature and extent of contamination, leading to closure in place with use restrictions; or (3) clean closure by remediation and verification. The following text summarizes the SAFER activities that will support the closure of CAU 130: • Perform site preparation activities (e.g., utilities clearances, geophysical surveys). • Move or remove and dispose of debris at various CASs, as required. • Collect environmental samples from designated target populations (e.g., stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish no further action as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC is present at a CAS, either: - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Obtain consensus from NDEP that the preferred closure option is sufficient to protect human health and the environment. • Close the underground storage tank(s) and their contents, if any, in accordance with Nevada Administrative Code regulations. • Remove the lead brick(s) found at any CAS in accordance with the Resource Conservation and Recovery Act.

54 ENVIRONMENTAL SCIENCES↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 114: Area 25 EMAD Facility Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 114, Area 25 EMAD Facility, identified in the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 114 comprises the following corrective action sites (CASs) located in Area 25 of the Nevada Test Site: • 25-41-03, EMAD Facility • 25-99-20, EMAD Facility Exterior Releases This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 114 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. It is anticipated that the results of the field investigation and implementation of a corrective action of clean closure will support a defensible recommendation that no further corrective action is necessary. If it is determined that complete clean closure cannot be accomplished during the SAFER, then a hold point will have been reached and the Nevada Division of Environmental Protection (NDEP) will be consulted to determine whether the remaining contamination will be closed under the alternative corrective action of closure in place. This will be presented in a closure report that will be prepared and submitted to NDEP for review and approval. The sites will be investigated based on the data quality objectives (DQOs) developed on April 30, 2009, by representatives of NDEP; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 114. The following text summarizes the SAFER activities that will support the closure of CAU 114: • Perform site preparation activities (e.g., utilities clearances, radiological surveys). • Collect environmental samples from designated target populations (e.g., stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • Collect samples of materials to determine whether potential source material (PSM) is present that may cause the future release of a COC to environmental media. • If no COCs or PSMs are present at a CAS, establish no further action as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC or PSM is present at a CAS, either: - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Confirm the selected closure option is sufficient to protect human health and the environment.

54 ENVIRONMENTAL SCIENCES↗

Streamlined Approach for (SAFER) Plan for Corrective Action Unit 566: E-MAD Compound, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 566, EMAD Compound, identified in the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 566 comprises the following corrective action site (CAS) located in Area 25 of the Nevada Test Site: • 25-99-20, EMAD Compound This plan provides the methodology for field activities needed to gather the necessary information for closing CAS 25-99-20. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 566 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action. It is anticipated that the results of the field investigation and implementation of a corrective action of clean closure will support a defensible recommendation that no further corrective action is necessary. If it is determined that complete clean closure cannot be accomplished during the SAFER, then a hold point will have been reached and the Nevada Division of Environmental Protection (NDEP) will be consulted to determine whether the remaining contamination will be closed under the alternative corrective action of closure in place. This will be presented in a closure report that will be prepared and submitted to NDEP for review and approval. The data quality objective (DQO) strategy for CAU 566 was developed at a meeting on April 30, 2009, by representatives of NDEP and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAU 566. The following text summarizes the SAFER activities that will support the closure of CAU 566: • Perform site preparation activities (e.g., utilities clearances, radiological surveys). • Collect environmental samples from designated target populations (e.g., stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • Collect samples of materials to determine whether potential source material (PSM) is present that may cause the future release of a COC to environmental media. • If no COCs or PSMs are present at a CAS, establish no further action as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC or PSM is present at a CAS, either: - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Confirm the selected closure option is sufficient to protect human health and the environment.

54 ENVIRONMENTAL SCIENCES↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 544: Cellars, Mud Pits, and Oil Spills, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 544, Cellars, Mud Pits, and Oil Spills, identified in the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 544 comprises the following 20 corrective action sites (CASs) located in Areas 2, 7, 9, 10, 12, 19, and 20 of the Nevada Test Site (NTS): • 02-37-08, Cellar & Mud Pit • 02-37-09, Cellar & Mud Pit • 07-09-01, Mud Pit • 09-09-46, U-9itsx20 PS #1A Mud Pit • 10-09-01, Mud Pit • 12-09-03, Mud Pit • 19-09-01, Mud Pits (2) • 19-09-03, Mud Pit • 19-09-04, Mud Pit • 19-25-01, Oil Spill • 19-99-06, Waste Spill • 20-09-01, Mud Pits (2) • 20-09-02, Mud Pit • 20-09-03, Mud Pit • 20-09-04, Mud Pits (2) • 20-09-06, Mud Pit • 20-09-07, Mud Pit • 20-09-10, Mud Pit • 20-25-04, Oil Spills • 20-25-05, Oil Spills This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 544 using the SAFER process. Using the approach approved for previous mud pit investigations (CAUs 530–535), 14 mud pits have been identified that • are either a single mud pit or a system of mud pits, • are not located in a radiologically posted area, and • have no evident biasing factors based on visual inspections. These 14 mud pits are recommended for no further action (NFA), and further field investigations will not be conducted. For the sites that do not meet the previously approved closure criteria, additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation for closure of the remaining CASs in CAU 544. This will be presented in a closure report (CR) that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The sites will be investigated based on the data quality objectives (DQOs) developed on April 27, 2010, by representatives of NDEP and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO). The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 544. The DQO process developed for this CAU identified the following expected closure options: (1) investigation and confirmation that no contamination exists above the final action levels (FALs) leading to an NFA declaration, (2) characterization of the nature and extent of contamination leading to closure in place with use restrictions, (3) clean closure by remediation and verification, (4) closure in place with use restrictions with no investigation if CASs are in crater areas that have been determined to be unsafe to enter, or (5) NFA if the mud pit CAS meets the criteria established during the CAUs 530–535 SAFER investigation. The following summarizes the SAFER activities that will support the closure of CAU 544: • Perform visual inspection of all CASs. • Perform site preparation activities (e.g., utilities clearances, construction of temporary site exclusion zones). • Removal of easily managed, nonhazardous, and nonradioactive debris, including vegetation (e.g., tumbleweeds), at various CASs that interfere with sampling, if required to inspect soil surface or collect soil sample. • Collect environmental samples from designated target populations (e.g., mud pits, cellars, stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish NFA as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC is present at a CAS, either - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Confirm the preferred closure option is sufficient to protect human health and the environment.

01 COAL, LIGNITE, AND PEAT↗

Fish scale-loss caused by simulated hydraulic shear stress

Riverine fishes found within streams impacted by hydropower also often pass through hydropower turbines during annual downstream migrations. During turbine passage events, fish may experience a suite of stressors including rapid pressure changes, impacts from turbine blades, and exposure to hydraulic shear. Scale-loss is often observed in fish collected below dams and hydraulic shear is the most likely cause of this trauma. While exposure to shear may cause other injuries, scale-loss appears to be the most common non-lethal injury observed to date. We sought to quantify how hydraulic shear may cause scale-loss in rainbow trout, gizzard shad, and hybrid striped bass by precisely controlling the exposure level (velocity) and duration (seconds) of a water jet. We targeted the same area for all three species found between the operculum and dorsal fin on the left, lateral surface. Exposure velocities ranged from 0 (controls) to 11.0 meters/second but fish were only exposed to the water jet for 1.5 seconds. A 0.2 milligram/milliliter solution of fluorescein was used to stain the areas of scale-loss by submerging each fish in this solution for at least 6 minutes. Fluorescein was used because it interacts with epithelial tissue that has been damaged and it fluoresces under ultraviolet lighting. Fish were photographed under short- and longwave ultraviolet lighting in a dark chamber to capture fluorescence. Fish photographs were analyzed using ImageJ and the proportion of descaled area was estimated for each fish within a 35 by 35-millimeter square. In general, these data highlight how exposure to hydraulic shear may lead to significant levels of descaling in riverine fishes.

13 HYDRO ENERGY↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial and Temporal Measurements of Temperature and Cell Viability in Response to Nanoparticle Mediated Photothermal Therapy

Aim: Nanoparticle enhanced photothermal therapy is a promising alternative to tumor resection. However, quantitative measurements of cellular response to these treatments are limited. This paper introduces a Bimodal Enhanced Analysis of Spatiotemporal Temperature (BEAST) algorithm to rapidly determine the viability of cancer cells in vitro following photothermal therapy alone or in combination with nanoparticles. Materials & Methods: To illustrate the capability of the BEAST viability algorithm, single wall carbon nanohorns were added to renal cancer (RENCA) cells in vitro and time-dependent spatial temperature maps measured with an infrared camera during laser therapy were correlated with post-treatment cell viability distribution maps obtained by cell-staining fluorescent microscopy. Conclusion: The BEAST viability algorithm accurately and rapidly determined the cell viability as function of time, space, and temperature.

laser↗

Luteolibacter sp. strain Populi

Luteolibacter sp. strain Populi is bacterium from the phylum Verrucomicrobiota, isolated from the rhizosphere of a black cottonwood tree, Populus trichocarpa, from the Cascade mountains in Washington. Its 6.6 Mb chromosome was completely sequenced using Oxford Nanopore long-reads and is predicted to encode 5301 proteins and 60 RNAs. The bacteria was isolated from the rhizosphere of a mature Populus trichocarpa from the Tieton riverwatershed of Washington state, USA (Lat: 46°42’9” N, Lon: 120°25 39’36” W). A rhizosphere sample (fine roots and adhering soil) was used to obtain a microbial fraction by centrifugation on Histodenz (12) and stained with 5µM Syto59 (Thermo Fisher Scientific Inc). A Cytopeia Influx cell sorter (BD, Franklin Lakes, NJ) was used to sort and array single cells (100 per plate) based on forward-side scatter and fluorescence intensity on asparagine-glucose nutrient agar (ATCC medium 184). The Luteolibacter sp. Populi genome sequence has been deposited in GenBank under the accession number CP161812. A draft genome annotated with Prokka and DRAM is available in this Narrative as Luteolibacter_sp_Prokka.240711.

59 BASIC BIOLOGICAL SCIENCES↗

64 Cu-Labeled Divalent Cystine Knot Peptide for Imaging Carotid Atherosclerotic Plaques

We present that the rupture of vulnerable atherosclerotic plaques that lead to stroke and myocardial infarction may be induced by macrophage infiltration and augmented by the expression of integrin α v β 3 . Indeed, atherosclerotic angiogenesis may be a promising marker of inflammation. In this study, an engineered integrin α v β 3 –targeting PET probe, 64 Cu-NOTA-3-4A, derived from a divalent knottin miniprotein was evaluated in a mouse model for carotid atherosclerotic plaques. Methods: Atherosclerotic plaques in BALB/C mice, maintained on a high-fat diet, were induced with streptozotocin injection and carotid artery ligation and verified by MR imaging. Knottin 3-4A was synthesized by solid-phase peptide synthesis chemistry and coupled to 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) before radiolabeling with 64 Cu. PET probe stability in mouse serum was evaluated. Mice with carotid atherosclerotic plaques were injected via the tail vein with 64 Cu-NOTA-3-4A or 18 F-FDG, followed by small-animal PET/CT imaging at different time points. Receptor targeting specificity of the probe was verified by coinjection of c(RGDyK) administered in molar excess. Subsequently, carotid artery dissection and immunofluorescence staining were performed to evaluate target expression. Results: 64 Cu-NOTA-3-4A was synthesized in high radiochemical purity and yield and demonstrated molecular stability in both phosphate-buffered saline and mouse serum at 4 h. Small-animal PET/CT showed that 64 Cu-NOTA-3-4A accumulated at significantly higher levels in the neovasculature of carotid atherosclerotic plaques (7.41 ± 1.44 vs. 0.67 ± 0.23 percentage injected dose/gram, P < 0.05) than healthy or normal vessels at 1 h after injection. 18 F-FDG also accumulated in atherosclerotic lesions at 0.5 and 1 h after injection but at lower plaque–to–normal tissue ratios than 64 Cu-NOTA-3-4A. For example, plaque–to–normal carotid artery ratios for 18 F-FDG and 64Cu-NOTA-3-4A at 1 h after injection were 3.75 and 14.71 (P < 0.05), respectively. Furthermore, uptake of 64 Cu-NOTA-3-4A in atherosclerotic plaques was effectively blocked (~90% at 1 h after injection) by coinjection of c(RGDyK). Immunostaining confirmed integrin α v β 3 expression in both the infiltrating macrophages and the neovasculature of atherosclerotic plaques. Conclusion: 64 Cu-NOTA-3-4A demonstrates specific accumulation in carotid atherosclerotic plaques in which macrophage infiltration and angiogenesis are responsible for elevated integrin αvβ3 levels. Furthermore, 64 Cu-NOTA-3-4A may demonstrate clinical utility as a PET probe for atherosclerosis imaging or for the evaluation of therapies used to treat atherosclerosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗