Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHAPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Mode Shape Estimation Algorithms Under Ambient Conditions: A Comparative Review

Abstract—This paper provides a comparative review of five existing ambient electromechanical mode shape estimation algorithms, i.e., the Transfer Function (TF), Spectral, Frequency Domain Decomposition (FDD), Channel Matching, and Subspace Methods. It is also shown that the TF Method is a general approach to estimating mode shape and that the Spectral, FDD, and Channel Matching Methods are actually special cases of it. Additionally, some of the variations of the Subspace Method are reviewed and the Numerical algorithm for Subspace State Space System IDentification (N4SID) is implemented. The five algorithms are then compared using data simulated from a 17-machine model of the Western Electricity Coordinating Council (WECC) under ambient conditions with both low and high damping, as well as during the case where ambient data is disrupted by an oscillatory ringdown. The performance of the algorithms is compared using the statistics from Monte Carlo Simulations and results from measured WECC data, and a discussion of the practical issues surrounding their implementation, including cases where power system probing is an option, is provided. The paper concludes with some recommendations as to the appropriate use of the various techniques. Index Terms—Electromechanical mode shape, small-signal stability, phasor measurement units (PMU), system identification, N4SID, subspace.

Dosiek, Luke↗

A microchannel for in vitro imaging of erythrocyte shape transformations by video microscopic technique

SummaryAn in-house fabricated microfluidic channel was developed using easily available materials (glass slide, transparency shapes, polyvinyl chloride tubes, coverslip, and epoxy) and manual positioning techniques with the aid of a profile projector, in the absence of other fabrication facilities.{sup 2,3,11–15} Despite the limitations of being less accurate and more laborious, manual methods offer an easy, inexpensive, and readily implementable alternative to automated ones. Being economical, they enable testing of newer models and hypothesis, development of new designs, and trail stage/prototype experimentation. Once the effectiveness of the developed channel is established, the manual fabrication method can eventually be automated. So far as erythrocyte deformability is concerned, the microchannel thus fabricated enabled multishape erythrocyte deformability analysis in contrast to the unishape approach by earlier studies.{sup 11–15,19} Though the microchannel in this study has larger width (30 μm) compared to the mean RBC diameter (~8 μm), it allows free orientation of cells and larger variation of shear condition across the channel cross section. Consequently, both asymmetrical and axial shapes were observed during the flow. Hence, it may be concluded that a larger cross section and medium to high flow (10–20 mm/s) may be appropriate for multishape characterization of erythrocytes in dilute suspensions. The issue of determining the DI for several deformed shapes and sorting them from other interacting and nondeforming RBCs could be handled with more flexible software techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bifurcation Buckling Analysis and Non-Linear Collapse Analysis of Teardrop Shaped Vacuum Chamber

The Spallation Neutron Source (SNS) accelerator is being upgraded to increase the beam power from 1.4MW at 1GeV to 2.8MW at 1.3GeV. The currents in the middle two injection chicane magnets cannot simply be scaled up to accommodate the increased injection energy of 1.3GeV due to potential excessive H- stripping; the magnets must be replaced with longer, lower-field magnets and the associated vacuum chambers need to be redesigned. A new teardrop-shaped vacuum chamber was initially designed to accommodate the new magnets and the updated beam paths and instrumentation. This paper focuses on the structural stability study of the teardrop shape vacuum chamber based on buckling analysis. Protection against collapse from buckling according to the ASME BPVC requirement has been evaluated in depth. First, a Type-1 bifurcation buckling analysis using a linear eigenvalue solution to determine the critical load factor was performed. Subsequently, a Type-3 nonlinear collapse analysis was conducted using the static Riks method with elastic-plastic material properties and imperfections explicitly considered in the model geometry. The critical buckling load for the teardrop shape vacuum chamber was confidently estimated based upon this two-stage approach.

Jiang, Hao↗

Analytical expressions of the surface shape of ‘diaboloid’ mirrors

Modern deterministic polishing processes allow fabrication of x-ray optics with almost any arbitrary aspherical surface shape. Among these optics, the so called "diaboloid"mirror is of special interest. The diaboloid mirror that converts a cylindrical wave to a spherical wave would improve focusing in x-ray beamlines implementing a diffraction element between a parabolic cylinder and a toroidal mirror. The replacement of the toroidal mirror in existing beamlines by the diaboloid mirror would mitigate aberrations. The shape of the diaboloid mirror is usually calculated numerically based on a truncated polynomial solution of the optical path problem. Here, we present an exact analytical solution for the shape of a diaboloid mirror as a function of the conjugate parameters of the mirror placed in a beamline. The derived analytical expressions for the diaboloid mirror in both the canonical and mirror-based coordinate systems are implemented in ray-tracing simulations to verify the beamline performances.

Yashchuk, Valeriy V.↗

Reducing variability in the output of pattern classifiers using histogram shaping

Purpose: The authors present a novel technique based on histogram shaping to reduce the variability in the output and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs. Methods: The authors identify different sources of variability in the output of linear pattern classifiers with identical ROC curves, which also result in classifiers with differently distributed outputs. They theoretically develop a novel technique based on the matching of the histograms of these differently distributed pattern classifier outputs to reduce the variability in their (sensitivity, specificity) pairs at fixed decision thresholds, and to reduce the variability in their actual output values. They empirically demonstrate the efficacy of the proposed technique by means of analyses on the simulated data and real world mammography data. Results: For the simulated data, with three different known sources of variability, and for the real world mammography data with unknown sources of variability, the proposed classifier output calibration technique significantly reduced the variability in the classifiers' (sensitivity, specificity) pairs at fixed decision thresholds. Furthermore, for classifiers with monotonically or approximately monotonically related output variables, the histogram shaping technique also significantly reduced the variability in their actual output values. Conclusions: Classifier output calibration based on histogram shaping can be successfully employed to reduce the variability in the output values and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-207-06: In Vivo Quantification of Gold Nanoparticles Using K-Edge Imaging Via Spectrum Shaping by Gold Filter

Purpose: Gold nanoparticles (AuNP) are multifunctional platforms ideal for drug delivery, targeted imaging and radiosensitization. We have investigated quantitative imaging of AuNPs using on board imager (OBI) cone beam computed tomography (CBCT). To this end, we also present, for the first time, a novel method for k-edge imaging of AuNP by filter-based spectral shaping. Methods: We used a digital 25 cm diameter water phantom, embedded with 3 cm spheres filled with AuNPs of different concentrations (0 mg/ml – 16 mg/ml). A poly-energetic X-ray spectrum of 140 kVp from a conventional X-ray tube is shaped by balanced K-edge filters to create an excess of photons right above the K-edge of gold at 80.7 keV. The filters consist of gold, tin, copper and aluminum foils. The phantom with appropriately assigned attenuation coefficients is forward projected onto a detector for each energy bin and then integrated. FKD reconstruction is performed on the integrated projections. Scatter, detector efficiency and noise are included. Results: We found that subtracting the results of two filter sets (Filter A:127 µm gold foil with 254 µm tin, 330 µm copper and 1 mm aluminum, and Filter B: 635 µm tin with 264 µm copper and 1 mm aluminum), provides substantial image contrast. The resulting filtered spectra match well below 80.7 keV, while maintaining sufficient X-ray quanta just above that. Voxel intensities of AuNP containing spheres increase linearly with AuNP concentration. K-edge imaging provides 18% more sensitivity than the tin filter alone, and 38% more sensitivity than the gold filter alone. Conclusion: We have shown that it is feasible to quantitatively detect AuNP distributions in a patient-sized phantom using clinical CBCT and K-edge spectral shaping.

60 APPLIED LIFE SCIENCES↗

SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

Cis-regulatory evolution shapes facial diversity in birds and mammals

Birds and mammals exhibit extraordinary facial diversity, reflecting adaptations to distinct ecological niches and feeding strategies. While core face-building developmental programs are conserved and orchestrated by interactions between ectodermal organizers and the underlying mesenchyme, mechanisms driving facial shape variation remain poorly understood. Here, we integrate single-cell transcriptomic and chromatin accessibility profiling of mouse and chicken developing face to construct a comparative regulatory map. Although both ectodermal and mesenchymal populations display distinct regulatory features in each species, the mesenchyme exhibits markedly greater divergence, pointing to its central role in shaping facial morphology. We further reveal unexpected molecular complexity in the main face-shaping organizer, including a mouse-specific Shh/Wnt5a expression domain. At key morphogen loci (Bmp4, Fgf8, and Wnt5a), conserved and lineage-specific enhancers exhibit spatially restricted activity patterns that mirror divergent signaling domains. These findings demonstrate how cis-regulatory evolution modulates conserved developmental programs to generate morphological novelty, providing a valuable resource for studying vertebrate facial evolution.

Kyomen, Stella [Max Planck Institute for Evolution↗

Molecular-dynamics simulation of the heat capacity for nickel and copper clusters: Shape and size effects

We have investigated the heat capacity of ideal Cu and Ni fcc clusters with diameters from 2 to 6 nm in the temperature range 200-800 K by the molecular-dynamics method using a modified tight-binding potential. Our analysis has shown consistency with the experimental results at temperatures of 200-300 K. The data obtained are also indicative of several regularities that are in agreement with the analytical calculations. We have concluded from the results of our computer simulations that the heat capacity in the case of isolated free clusters can exceed that of a bulk material, with this difference decreasing as the nanoparticle grows proportionally to the reduction in the fraction of surface atoms. The excess of the heat capacity for ideal copper and nickel nanoclusters with D = 6 nm at T = 200 K has been found to be 10% and 13%, respectively. Consequently, the large heat capacities of copper and nickel nanostructures observed in some real experiments cannot be related to the characteristics of free clusters. We hypothesize that these properties of a nanomaterial depend on the degree of agglomeration of its constituent particles, i.e., the surfaces and interphase boundaries of interconnected nanoclusters can have a strong effect. To test this hypothesis, we took nickel and copper clusters of various sizes (4000-7200 atoms) produced through the simulation of condensation from the gas phase. At high temperatures, we failed to adequately assess the role of the interphase boundaries in calculating the heat capacity of nanoparticles. The reason was the mass diffusion of Ni or Cu atoms to impart an energetically more favorable shape and structure to the synthesized clusters. At low temperatures, the heat capacity of such clusters exceeded that of clusters with an ideal shape and structure by a value from 3.2% to 10.6%. We have concluded that the Ni and Cu clusters produced in real experiments cannot be applied in devices using the thermal energy of such clusters without a preliminary optimization stage, because their external shape and interior structure are nonideal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of the shape on the spin state and exchange in quantum dots. Feynman path integral analysis

The ab initio computer simulation of the mixed quantum states of 1–5-nm model ellipsoid quantum dots with “soft” walls containing two and three quantum-indistinguishable nonrelativistic electrons has been performed by the path integral method. The calculation has been carried out beyond the single-electron and mean-field approximations with the fundamentally exact inclusion of Coulomb and exchange correlations of all orders and the spin variable. Distributions over the eigenfunctions of the spin-squared operator, as well as the equilibrium spin numbers, have been obtained depending on the shape of a quantum dot and the temperature. The complete set of basis functions symmetrized in permutations according to the spin of the system has been obtained by application of the Young symmetry operators. The dependence of the energy on the shape of the quantum dot corresponds to the negative sign of the surface tension at its boundary. The calculation indicates that the spin magnetic susceptibility in the system of two electrons decreases strongly for spherical quantum dots (“pairing” of spins) and the temperature dependences have a pronounced maximum whose position depends on the shape of the quantum dot. For three electrons in an oblate quantum dot, the inversion of the energy levels of spin states is observed and affects the spin magnetic susceptibility. The results indicate a strong dependence of the energy of collective spin states of electrons on the detailed inclusion of exchange and Coulomb spatial correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the shape of the cross section of a plasma-dielectric interface on the dispersion properties of high-frequency azimuthal surface modes

Theoretical study of the propagation of a packet of surface electromagnetic surface waves with a zero axial wavenumber in a circular-cross-section cylindrical metal waveguide within the frequency range that is higher than upper hybrid resonance is carried out. The waveguide is partially filled by plasma and immersed into axial magnetic field. The cross section of the plasma column is assumed to differ from circular shape. The effect of this shape on the dispersion properties of azimuthal surface modes is investigated by the method of successive approximations. The fields of the waves and their eigenfrequencies are determined up to terms of the second order in the deviation of the plasma cross section shape from the ring one. The correction to the eigenfrequency of azimuthal surface modes caused by this feature of the plasma column section is proved to increase with decreasing the external magnetic field and increasing the value of the dielectric constant of the dielectric, that separates the plasma from the metal wall of the waveguide. The spectral composition of the wave packet, in the form of which these modes propagate, is studied. The amplitudes of the satellite harmonics of these modes are found to increase with increasing the plasma density and decreasing the external magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse shape discrimination for Gerda Phase I data

The GERDA experiment located at the Laboratori Nazionali del Gran Sasso of INFN searches for neutrinoless double beta (0νββ) decay of 76 Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched 76 Ge fraction. The experimental sensitivity can be improved by analyzing the pulse shape of the detector signals with the aim to reject background events. This paper documents the algorithms developed before the data of Phase I were unblinded. The double escape peak (DEP) and Compton edge events of 2.615 MeV γ rays from 208Tl decays as well as two-neutrino double beta (2νββ) decays of 76 Ge are used as proxies for 0νββ decay. For BEGe detectors the chosen selection is based on a single pulse shape parameter. It accepts 0.92 ± 0.02 of signal-like events while about 80 % of the background events at Qββ = 2039 keV are rejected. For semi-coaxial detectors three analyses are developed. The one based on an artificial neural network is used for the search of 0νββ decay. It retains 90 % of DEP events and rejects about half of the events around Qββ . The 2νββ events have an efficiency of 0.85±0.02 and the one for 0νββ decays is estimated to be 0.90 +0.05 -0.09 . A second analysis uses a likelihood approach trained on Compton edge events. The third approach uses two pulse shape parameters. The latter two methods confirm the classification of the neural network since about 90 % of the data events rejected by the neural network are also removed by both of them. In general, the selection efficiency extracted from DEP events agrees well with those determined from Compton edge events or from 2νββ decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Particle Shape on Mechanical Behaviors of Rocks: A Numerical Study Using Clumped Particle Model

Since rocks are aggregates of mineral particles, the effect of mineral microstructure on macroscopic mechanical behaviors of rocks is inneglectable. Rock samples of four different particle shapes are established in this study based on clumped particle model, and a sphericity index is used to quantify particle shape. Model parameters for simulation in PFC are obtained by triaxial compression test of quartz sandstone, and simulation of triaxial compression test is then conducted on four rock samples with different particle shapes. It is seen from the results that stress thresholds of rock samples such as crack initiation stress, crack damage stress, and peak stress decrease with the increasing of the sphericity index. The increase of sphericity leads to a drop of elastic modulus and a rise in Poisson ratio, while the decreasing sphericity usually results in the increase of cohesion and internal friction angle. Based on volume change of rock samples during simulation of triaxial compression test, variation of dilation angle with plastic strain is also studied.

54 ENVIRONMENTAL SCIENCES↗

Linear gyrokinetic simulations of microinstabilities within the pedestal region of H-mode NSTX discharges in a highly shaped geometry

Linear (local) gyrokinetic predictions of edge microinstabilities in highly shaped, lithiated and non-lihiated NSTX discharges are reported using the gyrokinetic code GS2. Microtearing modes dominate the non-lithiated pedestal top. The stabilization of these modes at the lithiated pedestal top enables the electron temperature pedestal to extend further inwards, as observed experimentally. Kinetic ballooning modes are found to be unstable mainly at the mid-pedestal of both types of discharges, with unstable trapped electron modes nearer the separatrix region. At electron wavelengths, ETG modes are found to be unstable from mid-pedestal outwards for eta(e,exp)~2.2, with higher growth rates for the lithiated discharge. Near the separatrix, the critical temperature gradient for driving ETG modes is reduced in the presence of lithium, reflecting the reduction of the lithiated density gradients observed experimentally. A preliminary linear study in the edge of non-lithiated discharges shows that the equilibrium shaping alters the electrostatic modes stability, found more unstable at high plasma shaping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

The upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U Control System (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

Boyer, M↗

Human perceptions of colour rendition vary with average fidelity, average gamut, and gamut shape

An experiment was conducted to evaluate how subjective impressions of color quality vary with changes in average fidelity, average gamut, and gamut shape (which considers the specific hues that are saturated or desaturated). Twenty-eight participants each evaluated 26 lighting conditions—created using four, seven-channel, tunable LED luminaires—in a 3.1 m by 3.7 m room filled with objects selected to cover a range of hue, saturation, and lightness. IES TM-30 fidelity index (Rf) values ranged from 64 to 93, IES TM-30 gamut index (Rg¬) values from 79 to 117, and IES TM-30 Rcs,h1 values (a proxy for gamut shape) from -19% to 26%. All lighting conditions delivered the same nominal illuminance and chromaticity. Participants were asked to rate each condition on eight point semantic differential scales for saturated-dull, normal-shifted, and like-dislike. They were also asked one multiple choice question, classifying the condition as saturated, dull, normal, or shifted. The findings suggest that gamut shape is more important than average gamut for human preference, where reds play a more important role than other hues. Additionally, average fidelity alone is a poor predictor of human perceptions, although Rf was somewhat better than CIE Ra. The most preferred source had a CIE Ra value of 68, and 9 of the top 12 rated products had a CIE Ra value of 73 or less, which indicates that the commonly used criteria of CIE Ra ≥ 80 may be excluding a majority of preferred light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A molecular survey of Australian and North American termite genera indicates that vertical inheritance is the primary force shaping termite gut microbiomes

Termites and their microbial gut symbionts are major recyclers of lignocellulosic biomass. This important symbiosis is obligate but relatively open and more complex in comparison to other well-known insect symbioses such as the strict vertical transmission of Buchnera in aphids. The relative roles of vertical inheritance and environmental factors such as diet in shaping the termite gut microbiome are not well understood. Results The gut microbiomes of 66 specimens representing seven higher and nine lower termite genera collected in Australia and North America were profiled by small subunit (SSU) rRNA amplicon pyrosequencing. These represent the first reported culture-independent gut microbiome data for three higher termite genera: Tenuirostritermes , Drepanotermes , and Gnathamitermes ; and two lower termite genera: Marginitermes and Porotermes . Consistent with previous studies, bacteria comprise the largest fraction of termite gut symbionts, of which 11 phylotypes (6 Treponema , 1 Desulfarculus -like, 1 Desulfovibrio , 1 Anaerovorax -like, 1 Sporobacter -like, and 1 Pirellula -like) were widespread occurring in ≥50% of collected specimens. Archaea are generally considered to comprise only a minority of the termite gut microbiota (<3%); however, archaeal relative abundance was substantially higher and variable in a number of specimens including Macrognathotermes , Coptotermes , Schedorhinotermes , Porotermes , and Mastotermes (representing up to 54% of amplicon reads). A ciliate related to Clevelandella was detected in low abundance in Gnathamitermes indicating that protists were either reacquired after protists loss in higher termites or persisted in low numbers across this transition. Phylogenetic analyses of the bacterial communities indicate that vertical inheritance is the primary force shaping termite gut microbiota. The effect of diet is secondary and appears to influence the relative abundance, but not membership, of the gut communities. Conclusions Vertical inheritance is the primary force shaping the termite gut microbiome indicating that species are successfully and faithfully passed from one generation to the next via trophallaxis or coprophagy. Changes in relative abundance can occur on shorter time scales and appear to be an adaptive mechanism for dietary fluctuations.

60 APPLIED LIFE SCIENCES↗

High repetition-rate pulse shaping of a spectrally broadened Yb femtosecond laser

We demonstrate compression and shaping of few cycle pulses from a high average power ytterbium laser system. The pulses from a commercial 20 W, 100 kHz Yb laser system are spectrally broadened in two-stages using cascaded, gas-filled, stretched hollow-core fibers and then compressed and shaped in an acousto-optic modulator-based pulse-shaper. The pulse-shaper allows for compression, characterization, and shaping all in one system, producing ∼10 fs pulses with 30 μ J of energy.

Codere, Julia↗