Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Minimizing Ground Risk in Cellular-Connected Drone Corridors With mmWave Links

Unmanned Aircraft Systems (UASs) have been receiving significant interest and support from academia, industry, and regulatory bodies over the past decade due to their various use cases. To safely integrate UAS operations into the national airspace, particularly overpopulated regions, the risk posed to ground users, buildings, and vehicles due to unmanned aerial vehicle (UAV) flight should be minimized. This risk can be represented by a numerical metric, which we refer to in this article as the “ground risk.” Many UAS applications also depend on the presence of a reliable wireless communication link between the UAV and a control station for the transmission of UAV position, surveillance video, UAV payload commands, and other mission-related data. Such wireless communication requirements also need to be considered in the design of UAS operations. In this article, we consider both these aspects and study the design of nonintersecting trajectories for UAS operations to minimize ground risk, subject to constraints on the wireless signal strength and geometry of the trajectory, specified in terms of: 1) an enclosing cylinder within which the trajectory must lie and 2) an integrated angular change along the UAV's trajectory. The performance of a computationally expensive optimal algorithm is compared with that of a computationally faster heuristic approach within the dense urban environment of Manhattan, NY, USA. Performance evaluation using ray-tracing simulations shows that the heuristic approach performs close to the optimal algorithm at a reduced computation cost. In conclusion, this research can be utilized to make UAS operations safe and reliable and accelerate their adoption.

99 GENERAL AND MISCELLANEOUS↗

Response Variability in Commercial MOSFET SEE Qualification

Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS ) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a critical factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.

43 PARTICLE ACCELERATORS↗

Rapid Prediction of Low (<1%) trans Fat Content in Edible Oils and Fast Food Lipid Extracts by Infrared Spectroscopy and Partial Least Squares Regression

Abstract The United States Food and Drug Administration (FDA) ruled that partially hydrogenated oils (PHO), the major dietary source of industrially produced trans fat (TF), were no longer “generally recognized as safe (GRAS)” for any use in human food. Consequently, the objective of this study was to develop a rapid screening procedure using attenuated total reflection Fourier‐transform infrared (ATR‐FTIR) spectroscopy in conjunction with partial least squares regression (PLSR) for the quantitative and accurate prediction of low concentrations of trans fatty acid (TFAs) (<1% of total fatty acids (FAs)). Broad‐based calibration models were developed for a combined set of samples consisting of edible oils and fast food lipid extracts. Predicted concentrations of TFAs in the two matrices showed good correlation with the primary reference data generated by gas chromatography (GC) ( R 2 > 0.99) and high accuracy as evidenced by low root‐mean‐square error of cross‐validation (RMSECV) values. The lowest TFA concentration, determined by GC to be 0.13% of total FAs, was accurately predicted by ATR‐FTIR/PLSR as 0.18% of total FAs. This simple, rapid ATR‐FTIR/PLSR methodology has the potential for use as a screening alternative to conventional gas chromatographic methods for predicting the TFA content of edible oils and food lipid extracts for regulatory purposes and quality control of raw material and processed food. Practical Applications F DA ruled that partially hydrogenated oils were no longer “generally recognized as safe (GRAS)” for any use in human food. Consequently, we have proposed a rapid screening procedure, based on infrared spectroscopy and chemometrics, to rapidly and accurately predict low concentrations of trans fatty acids (<1% of total fatty acids) in edible oils and food lipid extracts.

Karunathilaka, Sanjeewa R.↗

Isotope-Specific Analysis of Neutron-Irradiated Lithium Aluminate Ceramics by Nuclear Magnetic Resonance Spectroscopy

The effects of neutron irradiation on lithium aluminate targets and the permeation of tritium into surrounding components are primary concerns in the development of materials for use in tritium production. The high specific activity and volatility of the tritium in activated samples greatly increase the challenges of experimental analysis. This paper reports the determination of the chemical forms and quantities of H-3 and Li-6 in irradiated and non-irradiated LiAlO2 by nuclear magnetic resonance (NMR) spectroscopy, and demonstrates that measurements can be performed in a non-destructive, safe manner to obtain isotope-selective, quantitative information on highly hazardous materials.

Tritium, solid state nuclear magnetic resonance sp↗

Sustained virological response with intravenous silibinin: individualized IFN-free therapy via real-time modelling of HCV kinetics

Providing here our aims and project background, we note that intravenous silibinin (SIL) is a potent antiviral agent against hepatitis C virus (HCV) genotype-1. In this proof of concept case-study we tested: (i) whether interferon-alfa (IFN)-free treatment with SIL plus ribavirin (RBV) can achieve sustained virological response (SVR); (ii) whether SIL is safe and feasible for prolonged duration of treatment and (iii) whether mathematical modelling of early on-treatment HCV kinetics can guide duration of therapy to achieve SVR. With our method, a 44 year-old female HCV-(genotype-1)-infected patient who developed severe psychiatric adverse events to a previous course of pegIFN+RBV, initiated combination treatment with 1200 mg/day of SIL, 1200 mg/day of RBV and 6000 u/day vitamin D. Blood samples were collected frequently till week 4, thereafter every 1-12 weeks until the end of therapy. The standard biphasic mathematical model with time-varying SIL effectiveness was used to predict the duration of therapy to achieve SVR. Our results show that, based on modelling the observed viral kinetics during the first 3 weeks of treatment, SVR was predicted to be achieved within 34 weeks of therapy. Provided with this information, the patient agreed to complete 34 weeks of treatment. IFN-free treatment with SIL+RBV was feasible, safe and achieved SVR (week-33). In conclusion, we report, for the first time, the use of real-time mathematical modelling of HCV kinetics to individualize duration of IFN-free therapy and to empower a patient to participate in shared decision making regarding length of treatment. SIL-based individualized therapy provides a treatment option for patients who do not respond to or cannot receive other HCV agents and should be further validated.

59 BASIC BIOLOGICAL SCIENCES↗

Beyond leaf habit: generalities in plant function across 97 tropical dry forest tree species

Leaf habit has been hypothesized to define a linkage between the slow-fast plant economic spectrum and the drought resistance-avoidance trade-off in tropical forests (‘slow-safe vs fast-risky’). However, variation in hydraulic traits as a function of leaf habit has rarely been explored for a large number of species. We sampled leaf and branch functional traits of 97 tropical dry forest tree species from four sites to investigate whether patterns of trait variation varied consistently in relation to leaf habit along the ‘slow-safe vs fast-risky’ trade-off. Leaf habit explained from 0% to 43.69% of individual trait variation. We found that evergreen and semi-deciduous species differed in their location along the multivariate trait ordination when compared to deciduous species. While deciduous species showed consistent trait values, evergreen species trait values varied as a function of the site. Last, trait values varied in relation to the proportion of deciduous species in the plant community. Here We found that leaf habit describes the strategies that define drought avoidance and plant economics in tropical trees. However, leaf habit alone does not explain patterns of trait variation, which suggests quantifying site-specific or species-specific uncertainty in trait variation as the way forward.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Evaluation of a Respirator Vortex Cooling Device

The United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina, is dedicated to promoting site-level, risk-based inspection practices to maintain a safe and productive work environment. Protective suits are worn by personnel working in contaminated environments. These suits require that cooling be applied to keep the interior temperature within safe and comfortable limits. A vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT), can provide the necessary cooling. As mechanical devices void of moving components, vortex tubes separate a compressed gas into hot and cold streams—the air emerging from the “hot” end reaching a temperature of 433.2 K and the air emerging from the “cold” end reaching a temperature of 241.5 K (Hilsch, 1946, “Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß,” Z. Für Naturforsch., 1, pp. 208–214). Routing the cold stream of the vortex tube to the user's protective suit facilitates the required cooling. Vortex tubes currently in use at SRS are preset, through modification solely by and within the SRS respiratory equipment facility (REF), to provide a temperature reduction between 22.2 and 25.0 K. When a new model of vortex tube capable of user adjustment during operation recently became available, prototype testing was conducted for product comparison. Ultimately, it was identified that similar cooling performance between the old and new models is achievable. Production units were acquired to be subjected to complete product analysis at SRS utilizing a statistical test plan. Finally, the statistical test plan, data, thermodynamic calculations, and conclusions were reviewed to determine acceptability for site use.

47 OTHER INSTRUMENTATION↗

An Approach to Bayesian Optimization for Design Feasibility Check on Discontinuous Black-Box Functions

The paper presents a novel approach to applying Bayesian Optimization (BO) in predicting an unknown constraint boundary, also representing the discontinuity of an unknown function, for a feasibility check on the design space, thereby representing a classification tool to discern between a feasible and infeasible region. Bayesian optimization is a low-cost black-box global optimization tool in the Sequential Design Methods where one learns and updates knowledge from prior evaluated designs, and proceeds to the selection of new designs for future evaluation. However, BO is best suited to problems with the assumption of a continuous objective function and does not guarantee true convergence when having a discontinuous design space. This is because of the insufficient knowledge of the BO about the nature of the discontinuity of the unknown true function. In this paper, we have proposed to predict the location of the discontinuity using a BO algorithm on an artificially projected continuous design space from the original discontinuous design space. The proposed approach has been implemented in a thin tube design with the risk of creep-fatigue failure under constant loading of temperature and pressure. The stated risk depends on the location of the designs in terms of safe and unsafe regions, where the discontinuities lie at the transition between those regions; therefore, the discontinuity has also been treated as an unknown creep-fatigue failure constraint. The proposed BO algorithm has been trained to maximize sampling toward the unknown transition region, to act as a high accuracy classifier between safe and unsafe designs with minimal training cost. The converged solution has been validated for different design parameters with classification error rate and function evaluations at an average of <1% and ~150, respectively. Finally, the performance of our proposed approach in terms of training cost and classification accuracy of thin tube design is shown to be better than the existing machine learning (ML) algorithms such as Support Vector Machine (SVM), Random Forest (RF), and Boosting.

Engineering↗

D and D projects of Tecnubel in Belgium and abroad

Safe decontamination is a regular requirement in the lifecycle of a nuclear plant and is integral to the careful maintenance of any nuclear installation for 4 key reasons: - To decrease the risk of radioactive contamination spreading; - To limit the radioactive doses contracted by maintenance personnel; - To limit the radioactive doses incurred during decommissioning; - To downgrade the class of radioactive waste The primary goal of decommissioning is to remove aged and/or contaminated and/or activated components of an installation, safely and securely, in as short a time as possible. There are several reasons why this may be necessary: - To eliminate the risk of radioactive contamination spreading; - To eliminate the risk of radiation; - To downgrade a site or a circuit to a point where it no longer is submitted to regular inspection; - To remove installations or parts that are no longer in service or have aged There are many different D and D techniques, tools and materials available today. What is important is knowing how best to use them. This paper describes the experiences and the future projects of Tecnubel in D and D projects in Belgium and abroad. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rocky flats closure project - lessons learned in worker stakeholder engagement

The Rocky Flats Environmental Technology Site (EPA Superfund site near Denver, Colorado) produced plutonium components for nuclear weapons for the U.S. defense program. The facility shut down in 1989 and clean up began in 1992. To ensure safe remediation of inactive nuclear sites, site owners have begun to consult stakeholders more widely in recent years. The closure of Rocky Flats aimed to set the standard for stakeholder involvement in doing the work safely, complying with regulations/standards, in a cost-effective manner. We have studied, using ethnographic methods, the extent to which workers at Rocky Flats were involved in communication and decision making strategies. Our results point out that workers can have perceptions of the site remediation process that differ from management and even other workers and that a significant number of workers questioned the commitment by management to engage the worker as stakeholder. The most effective remediation efforts should involve careful consideration of the insights and observations of all workers, particularly those who face immediate and high-level health and safety risks. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electromechanical response of piezoelectric thin films subjected to large strain

The use of piezoelectric thin sensors, when subjected to large static strain levels in ultrasonic applications is reported in this paper. A novel flipped beam bending method is proposed to induce static strain level nearing twice the incipient yield strain in the beam material (~0.39%). First, the effect of static large strain on ultrasonic guided wave propagation in the beam was studied using the velocity measurements obtained from a laser Doppler vibrometer. Next, the ultrasonic response of thin sensors is studied under compressive and tensile static strain (±0.72%) with the sensors symmetrically bonded on the lower and upper surfaces, and at the same axial location. The ultrasonic guided wave response to varying levels of static strain is recorded at different center frequencies (50–400 kHz) of the narrow banded ultrasonic excitation. As a case study, the variation of the ultrasonic guided wave response of polyvinylidene difluoride (PVDF) thin sensors with center frequencies at different static strain levels was analyzed and compared with that of lead zirconate titanate (PZT) thin sensors. PZT sensors show a higher variation of sensing performance with strain when compared to PVDF sensors. Apart from static strain, the possible effects on the change in performance of sensors, such as the change in the capacitance is discussed. The characterization method provides a reusable beam arrangement to study the ultrasonic sensor performance at large static strain levels. Characterization at large strain level allows the development of fail-safe sensors even under large strain and permanent plastic deformation of structure on which they are bonded, allowing accurate ultrasonic structural health monitoring even in the presence of damage progression. Piezopolymer sensor like PVDF are least susceptible to static strain due to large yield strain and low modulus and can serve as fail-safe sensors under large strain.

Rathod, Vivek↗

Optimizing Transmission of Acoustic Signals to Monitor Internal Conditions of Canisters for Dry Storage of Commercial Spent Nuclear Fuel

Safe storage of spent nuclear fuel (SNF) is critical to the nuclear fuel cycle and the future of nuclear energy. In the United States, SNF is stored primarily via two methods regulated by the U.S. Nuclear Regulatory Commission: wet storage in SNF pools and dry storage in dry cask storage systems (DCSSs). After about five years of cooling in spent fuel pools, the fuel assemblies are transferred into DCSSs, and the systems are filled with helium and sealed by welding. Deterioration of conditions inside of a DCSS is reflected in changes in the internal gas properties; this motivates the development of acoustic techniques to monitor internal gas properties, over extended storage periods, using sensors mounted on the exterior of the storage packages. However, a major challenge in collecting acoustic signals is the impedance mismatch between the steel canister shell and the gas. Only a small fraction of the ultrasonic signal can be transmitted through the gas medium. This paper documents experimental studies conducted on a full-scale canister mock-up to capture the gas-borne signals. Damping materials were pasted on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The results show that the excitation frequency plays an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight. A high signal-to-noise ratio was achieved in the measurements. Next, the acoustic impedance matching layers were introduced, and the gas signal was drastically improved compared with that using no AIM layers.

Spent nuclear fuel (SNF), Canisters, Internal cond↗

Impact of dose size in single fraction spatially fractionated (grid) radiotherapy for melanoma

Purpose: To evaluate the impact of dose size in single fraction, spatially fractionated (grid) radiotherapy for selectively killing infiltrated melanoma cancer cells of different tumor sizes, using different radiobiological models. Methods: A Monte Carlo technique was employed to calculate the 3D dose distribution of a commercially available megavoltage grid collimator in a 6 MV beam. The linear-quadratic (LQ) and modified linear quadratic (MLQ) models were used separately to evaluate the therapeutic outcome of a series of single fraction regimens that employed grid therapy to treat both acute and late responding melanomas of varying sizes. The dose prescription point was at the center of the tumor volume. Dose sizes ranging from 1 to 30 Gy at 100% dose line were modeled. Tumors were either touching the skin surface or having their centers at a depth of 3 cm. The equivalent uniform dose (EUD) to the melanoma cells and the therapeutic ratio (TR) were defined by comparing grid therapy with the traditional open debulking field. The clinical outcomes from recent reports were used to verify the authors’ model. Results: Dose profiles at different depths and 3D dose distributions in a series of 3D melanomas treated with grid therapy were obtained. The EUDs and TRs for all sizes of 3D tumors involved at different doses were derived through the LQ and MLQ models, and a practical equation was derived. The EUD was only one fifth of the prescribed dose. The TR was dependent on the prescribed dose and on the LQ parameters of both the interspersed cancer and normal tissue cells. The results from the LQ model were consistent with those of the MLQ model. At 20 Gy, the EUD and TR by the LQ model were 2.8% higher and 1% lower than by the MLQ, while at 10 Gy, the EUD and TR as defined by the LQ model were only 1.4% higher and 0.8% lower, respectively. The dose volume histograms of grid therapy for a 10 cm tumor showed different dosimetric characteristics from those of conventional radiotherapy. A significant portion of the tumor volume received a very large dose in grid therapy, which ensures significant tumor cell killing in these regions. Conversely, some areas received a relatively small dose, thereby sparing interspersed normal cells and increasing radiation tolerance. The radiobiology modeling results indicated that grid therapy could be useful for treating acutely responding melanomas infiltrating radiosensitive normal tissues. The theoretical model predictions were supported by the clinical outcomes. Conclusions: Grid therapy functions by selectively killing infiltrating tumor cells and concomitantly sparing interspersed normal cells. The TR depends on the radiosensitivity of the cell population, dose, tumor size, and location. Because the volumes of very high dose regions are small, the LQ model can be used safely to predict the clinical outcomes of grid therapy. When treating melanomas with a dose of 15 Gy or higher, single fraction grid therapy is clearly advantageous for sparing interspersed normal cells. The existence of a threshold fraction dose, which was found in the authors’ theoretical simulations, was confirmed by clinical observations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Human radiation dosimetry of 6-[{sup 18}F]FDG predicted from preclinical studies

Purpose: The authors are developing 6-[{sup 18}F]fluoro-6-deoxy-D-glucose (6-[{sup 18}F]FDG) as an in vivo tracer of glucose transport. While 6-[{sup 18}F]FDG has the same radionuclide half-life as 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (2-[{sup 18}F]FDG) which is ubiquitously used for PET imaging, 6-[{sup 18}F]FDG has special biologic properties and different biodistributions that make it preferable to 2-[{sup 18}F]FDG for assessing glucose transport. In preparation for 6-[{sup 18}F]FDG use in human PET scanning, the authors would like to determine the amount of 6-[{sup 18}F]FDG to inject while maintaining radiation doses in a safe range. Methods: Rats were injected with 6-[{sup 18}F]FDG, euthanized at specified times, and tissues were collected and assayed for activity content. For each tissue sample, the percent of injected dose per gram was calculated and extrapolated to that for humans in order to construct predicted time-courses. Residence times were calculated as areas under the curves and were used as inputs to OLINDA/EXM in order to calculate the radiation doses. Results: Unlike with 2-[{sup 18}F]FDG for which the urinary bladder wall receives the highest absorbed dose due to urinary excretion, with 6-[{sup 18}F]FDG there is little urinary excretion and osteogenic cells and the liver are predicted to receive the highest absorbed doses: 0.027 mGy/MBq (0.100 rad/mCi) and 0.018 mGy/MBq (0.066 rad/mCi), respectively. Also, the effective dose from 6-[{sup 18}F]FDG, i.e., 0.013 mSv/MBq (0.046 rem/mCi), is predicted to be approximately 30% lower than that from 2-[{sup 18}F]FDG. Conclusions: 6-[{sup 18}F]FDG will be safe for use in the PET scanning of humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-622: Identification and Improvement of Patients Eligible for Dose Escalation with Matched Plans

Purpose: Radiation-therapy dose-escalation beyond 80Gy may improve tumor control rates for patients with localized prostate cancer. Since toxicity remains a concern, treatment planners must achieve dose-escalation while still adhering to dose-constraints for surrounding structures. Patientmatching is a machine-learning technique that identifies prior patients that dosimetrically match DVH parameters of target volumes and critical structures prior to actual treatment planning. We evaluated the feasibility of patient-matching in (1)identifying candidates for safe dose-escalation; and (2)improving DVH parameters for critical structures in actual dose-escalated plans. Methods: We analyzed DVH parameters from 319 historical treatment plans to determine which plans could achieve dose-escalation (8640cGy) without exceeding Zelefsky dose-constraints (rectal and bladder V47Gy<53%, and V75.6Gy<30%, max-point dose to rectum of 8550cGy, max dose to PTV< 9504cGy). We then estimated the percentage of cases that could achieve safe dose-escalation using software that enables patient matching (QuickMatch, Siris Medical, Mountain View, CA). We then replanned a case that had violated DVH constraints with DVH parameters from patient matching, in order to determine whether this previously unacceptable plan could be made eligible with this automated technique. Results: Patient-matching improved the percentage of patients eligible for dose-escalation from 40% to 63% (p=4.7e-4, t-test). Using a commercial optimizer augmented with patient-matching, we demonstrated a case where patient-matching improved the toxicity-profile such that dose-escalation would have been possible; this plan was rapidly achieved using patientmatching software. In this patient, all lower-dose constraints were met with both the denovo and patient-matching plan. In the patient-matching plan, maximum dose to the rectum was 8385cGy, while the denovo plan failed to meet the maximum rectal constraint at 8571cGy. Conclusion: Patientmatching is a promising method to identify eligible patients, and to assist in creating acceptable plans for dose-escalation. Further study will investigate other disease states. Additionally, the time-savings provided by patientmatching warrants further investigation. The following authors have equity ownership in Siris Medical, Inc: K Bush, TF Atwood.

60 APPLIED LIFE SCIENCES↗

TU-A-BRD-01: Outcomes of Hypofractionated Treatments - Initial Results of the WGSBRT

Stereotactic Body Radiation Therapy (SBRT) has emerged in recent decades as a treatment paradigm that is becoming increasingly important in clinical practice. Clinical outcomes data are rapidly accumulating. Although published relations between outcomes and dose distributions are still sparse, the field has progressed to the point where evidence-based normal tissue dose-volume constraints, prescription strategies, and Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) models can be developed. The Working Group on SBRT (WGSBRT), under the Biological Effects Subcommittee of AAPM, is a group of physicists and physicians working in the area of SBRT. It is currently performing critical literature reviews to extract and synthesize usable data and to develop guidelines and models to aid with safe and effective treatment. The group is investigating clinically relevant findings from SBRT in six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session of AAPM 2014, interim results are presented on TCP for lung and liver, NTCP for thoracic organs, and radiobiological foundations:• Lung TCP: Detailed modeling of TCP data from 118 published studies on early stage lung SBRT investigates dose response and hypothesized mechanisms to explain the improved outcomes of SBRT. This is presented from the perspective of a physicist, a physician, and a radiobiologist.• Liver TCP: For primary and metastatic liver tumors, individual patient data were extracted from published reports to examine the effects of biologically effective dose on local control.• Thoracic NTCP: Clinically significant SBRT toxicity of lung, rib / chest wall and other structures are evaluated and compared among published clinical data, in terms of risk, risk factors, and safe practice.• Improving the clinical utility of published toxicity reports from SBRT and Hypofractionated treatments. What do we want, and how do we get it? Methods and problems of synthesizing data from published reports. Learning Objectives: Common SBRT fractionation schemes and current evidence for efficacy. Evidence for normal tissue tolerances in hypofractionated treatments. Clinically relevant radiobiological effects at large fraction sizes.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-07: Real-Time Personalized Margins

Purpose: To maximize normal tissue sparing for treatments requiring motion encompassing margins. Motion mitigation techniques including DMLC or couch tracking can freeze tumor motion within the treatment aperture potentially allowing for smaller treatment margins and thus better sparing of normal tissue. To enable for a safe application of this concept in the clinic we propose adapting margins dynamically in real-time during radiotherapy delivery based on personalized tumor localization confidence. To demonstrate technical feasibility we present a phantom study. Methods: We utilize a realistic anthropomorphic dynamic thorax phantom with a lung tumor model embedded close to the spine. The tumor, a 3D-printout of a patient's GTV, is moved 15mm peak-to-peak by diaphragm compression and monitored by continuous EPID imaging in real-time. Two treatment apertures are created for each beam, one representing ITV -based and the other GTV-based margin expansion. A soft tissue localization (STiL) algorithm utilizing the continuous EPID images is employed to freeze tumor motion within the treatment aperture by means of DMLC tracking. Depending on a tracking confidence measure (TCM), the treatment aperture is adjusted between the ITV and the GTV leaf. Results: We successfully demonstrate real-time personalized margin adjustment in a phantom study. We measured a system latency of about 250 ms which we compensated by utilizing a respiratory motion prediction algorithm (ridge regression). With prediction in place we observe tracking accuracies better than 1mm. For TCM=0 (as during startup) an ITV-based treatment aperture is chosen, for TCM=1 a GTV-based aperture and for 0<TCM<1 a linear interpolation between the two apertures is chosen. Conclusions: We have proposed and demonstrated a concept to safely shrink treatment margins during radiotherapy and adapt to tracking confidence in real-time. Normal tissue sparing is maximized. The worst case scenario results in delivering a plan with standard margins used in the clinic today.

60 APPLIED LIFE SCIENCES↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗