Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Effect of Curing Temperature and Composition on the Performance Properties of Saltstone - 12473

When freshly mixed Saltstone is placed into a vault at the Savannah River Site, the heat of hydration produced during curing causes the temperature of the grout to increase. It is not uncommon for the temperature of the grout to increase by 30 to 50 deg. C above the starting temperature depending on the vault size and location, environmental conditions and pour schedule. For example, temperatures measured by thermocouples in one cell have exceeded 70 deg. C. The elevated temperatures, once reached, can extend for weeks or even months. Recent studies at Savannah River National Laboratory (SRNL) have shown that curing simulated Saltstone mixes at elevated temperatures can lead to reduced compressive strength and dynamic Young's modulus as well as increased total porosity when compared to the same grout mixes cured at 20 deg. C. Samples cured at 60 deg. C can have hydraulic conductivities approximately 600 times greater than samples cured at 20 deg. C. Previous studies have shown that the 60 deg. C cured mix had a dynamic Young's modulus that was half that of the mix cured at 20 deg. C. However, high temperature curing may not always have negative effects on the performance properties of the grout. These results indicate that higher curing temperatures can significantly alter the performance properties that are inputs for the Saltstone Performance Assessment. The Saltstone formulation (mix design) must produce a grout waste form that meets both placement and performance properties. A statistically designed set of mixes was developed to determine key process and compositional factors that affect the performance properties of Saltstone grout. A total of 27 mixes were batched and tested. There are eight baseline mixes that contain high and low values of aluminate concentration, varying w/p ratio, and varying fly ash content in the premix. Each of the eight mixes was cured at 22, 40 and 60 deg. C. The three additional reference mixes batched at the beginning, middle and end of testing showed good reproducibility throughout the study. The results of varying the operational and compositional factors on the performance properties of Saltstone grout are: - The Young's modulus is inversely affected by the curing temperature of the grout. - The aluminate content of the salt solution increases the Young's modulus of the Saltstone for samples cured at 20 and 40 deg. C. - All grouts cured at 60 deg. C have low Young's moduli and the composition of the grout mix did not have any positive effects on the performance properties after curing at this temperature. - The fly ash content in the premix had not discernible effect on the Young's modulus. - The water to premix ratio does not affect the Young's modulus. - Grouts made with the high aluminate salt solution have lower hydraulic conductivities than those made with the low aluminate simulant. - Temperature has an inverse effect on the hydraulic conductivity. - In general, increasing the water to premix ratio and the fly ash content will increase the hydraulic conductivity. - The porosity and cured density of the Saltstone grout are primarily a factor of the water to premix ratio of the grout formulation. The correlation between hydraulic conductivity and Young's modulus investigated in previous studies was evaluated further in this report. The current data as well as data from previous studies was fitted by a second degree polynomial function with a 77.1 % R-squared value. This model can be used to estimate the hydraulic conductivity of a sample based its Young's modulus for a limited range (E values up to 7 GPa). More data points should be included to further define the relationship between these performance properties are high Young's moduli and low hydraulic conductivities. The Young's modulus should still be measured on grouts formulated in future studies to be used as screening method for samples to be sent for hydraulic conductivity measurements. Saltstone grout has a complicated microstructure that is affected by the composition of the salt solution, the dry feed mixture composition, and the conditions under which it cures. The performance properties investigated are interrelated, which can make it difficult to determine individual relationships between various factors. Porosity is a large factor in determining both the Young's modulus and the hydraulic conductivity of the samples. Although the cured density is a straightforward measurement, it is not a significant performance property that needs further investigation. The porosity measurement provides similar and more meaningful data in relation to other performance properties. Based on the results of this study, the aluminate content of the salt solution does have an effect on the Young's modulus and the hydraulic conductivity and its effects should continue to be investigated. However, a new projection of aluminate contents should be used since projections change over time. The variability of fly ash in the premix did not prove to be a contributing factor that effects the performance properties of Saltstone and does not need to be included in future studies unless significant deviations from the baseline mix are proposed. The water to premix ratio has a significant effect on the performance properties of interest and the effects of varying this factor need further investigation. It is recommended that smaller ranges of w/p are investigated in order to provide data that is more relevant to the Saltstone being placed in the vaults. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Highlighting the Importance of Authentic Reference Chemicals in the Unambiguous Identification of Unknowns during Routine Sample Analysis─An OPCW Proficiency Test Case

The unequivocal identification of unknown chemicals during routine sample analysis is a constant occurrence in the field of analytical chemistry. The process can be painstakingly tedious, particularly in situations where a tentatively identified unknown may possess isomeric counterparts yielding identical accurate mass values and very similar mass spectra. In this work, we present the experimental process involved in the correct identification of 1,4-oxathiane 4,4-dioxide and differentiation from its constitutional isomer, 2-hydroxyethyl vinyl sulfone, when present in a silica gel matrix featured in the 54th Environmental Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test. After discovering that the library-generated mass spectrum for 2-hydroxyethyl vinyl sulfone in a preliminary gas chromatography–mass spectrometry (GC-MS) analysis did not match the one from an authentic reference chemical, we embarked on an unknown structure determination campaign involving GC-MS, liquid chromatography-tandem mass spectrometry (LC-MS-MS), and nuclear magnetic resonance (NMR) spectroscopy. All of the information obtained, coupled to the synthesis of an authentic reference chemical, was used to determine the identity of the unknown as 1,4-oxathiane 4,4-dioxide. The process described in this work highlights the important role played by authentic reference chemicals in the identification of unknown chemicals during routine sample analysis.

Chemistry↗

Adaptive scapula bone remodeling computational simulation: Relevance to regenerative medicine

Shoulder arthroplasty success has been attributed to many factors including, bone quality, soft tissue balancing, surgeon experience, and implant design. Improved long-term success is primarily limited by glenoid implant loosening. Prosthesis design examines materials and shape and determines whether the design should withstand a lifetime of use. Finite element (FE) analyses have been extensively used to study stresses and strains produced in implants and bone. However, these static analyses only measure a moment in time and not the adaptive response to the altered environment produced by the therapeutic intervention. Computational analyses that integrate remodeling rules predict how bone will respond over time. Recent work has shown that subject-specific two- and three dimensional adaptive bone remodeling models are feasible and valid. Feasibility and validation were achieved computationally, simulating bone remodeling using an intact human scapula, initially resetting the scapular bone material properties to be uniform, numerically simulating sequential loading, and comparing the bone remodeling simulation results to the actual scapula’s material properties. Three-dimensional scapula FE bone model was created using volumetric computed tomography images. Muscle and joint load and boundary conditions were applied based on values reported in the literature. Internal bone remodeling was based on element strain-energy density. Initially, all bone elements were assigned a homogeneous density. All loads were applied for 10 iterations. After every iteration, each bone element’s remodeling stimulus was compared to its corresponding reference stimulus and its material properties modified. The simulation achieved convergence. At the end of the simulation the predicted and actual specimen bone apparent density were plotted and compared. Location of high and low predicted bone density was comparable to the actual specimen. High predicted bone density was greater than actual specimen. Low predicted bone density was lower than actual specimen. Differences were probably due to applied muscle and joint reaction loads, boundary conditions, and values of constants used. Work is underway to study this. Nonetheless, the results demonstrate three dimensional bone remodeling simulation validity and potential. Such adaptive predictions take physiological bone remodeling simulations one step closer to reality. Computational analyses are needed that integrate biological remodeling rules and predict how bone will respond over time. We expect the combination of computational static stress analyses together with adaptive bone remodeling simulations to become effective tools for regenerative medicine research.

60 APPLIED LIFE SCIENCES↗

SU-E-T-249: Neutron Model Upgrade for Radiotherapy Patients Monitoring Using a New Online Detector

Purpose: The purpose of this work is to improve the existing methodology to estimate neutron equivalent dose in organs during radiotherapy treatments, based on a Static Random Access Memory neutron detector (SRAMnd) [1]. This is possible thanks to the introduction of a new digital detector with improved characteristics, which is able to measure online the neutron fluence rate in the presence of an intense photon background [2]. Its reduced size, allows the direct estimation of doses in specific points inside an anthropomorphic phantom (NORMA) without using passive detectors as TLD or CR-39. This versatility will allow not only to improve the existing models (generic abdomen and H and N [1]) but to generate more specific ones for any technique. Methods: The new Thermal Neutron Rate Detector (TNRD), based on a diode device sensitized to thermal neutrons, have been inserted in 16 points of the phantom. These points are distributed to infer doses to specific organs. Simultaneous measurements of these devices and a reference one, located in front of the gantry, have been performed for the mentioned generic treatments, in order to improve the existing model. Results: These new devices have shown more precise since they agree better with Monte Carlo simulations. The comparison of the thermal neutron fluence, measured with TNRD, and the existing models, converted from events to fluence, shows an average improvement of (3.90±3.37) % for H and N and (12.61±9.43) % for abdomen, normalized to the maximum value. Conclusion: This work indicates the potential of these new devices for more precise neutron equivalent dose estimation in organs, as a consequence of radiotherapy treatments. The simplicity of the process makes possible to establish more specific models that will provide a better dose estimation. References[1] Phys Med Biol 2012; 57:6167–6191.[2] A new active thermal neutron detector. Radiat. Prot. Dosim. (in press)

60 APPLIED LIFE SCIENCES↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling Oxidative Dehydrogenation of Propane with Supported Vanadia Catalysts Using Multireference Methods

The oxidative dehydrogenation of propane over supported vanadium oxide catalysts poses significant computational challenges due to complex electronic structure changes along the reaction coordinate, driven primarily by changes in the oxidation states of vanadium. To address these challenges, we systematically test quantum chemical methods, including multireference (MR) approaches, domain-based local pair natural orbital coupled cluster theory (DLPNO-CCSD(T)), and density functional theory (DFT). The initial C–H bond-breaking transition state requires MR treatment due to its multireference character, while subsequent steps permit efficient single-reference calculations. For the rate-limiting C–H activation step mediated by the vanadyl moiety, complete 1 active space second-order perturbation theory (CASPT2) yields an apparent activation barrier (E app 600K ) of 138 kJ/mol, consistent with experimental values (134 ± 4 kJ/mol; Gruene et al. Catal. Today 2010, 157, 137). In contrast, DLPNO-CCSD(T) overestimates this barrier (198 kJ/mol), whereas DFT predictions span 125–150 kJ/mol, depending on the functional. Our multireference investigation of this transition metal oxide-catalyzed process demonstrates that an active space that incorporates the C–H σ and V=O σ/π bonding orbitals, oxygen lone pairs, and their antibonding counterparts adequately captures electronic structure changes along the chemical transformation. Furthermore, these findings provide a general strategy for active space selection in transition metal oxide-catalyzed C/O–H bond activation reactions. The reference dataset from this work, which includes MR calculations with manually selected active spaces for all intermediates and transition states in the propane ODH reaction network, will serve as a benchmark for automating active space selection in similar systems.

Catalysts↗

Predictive role of PI-RADSv2 and ADC parameters in differentiating Gleason pattern 3 + 4 and 4 + 3 prostate cancer

Purpose: To compare the predictive roles of qualitative (PI-RADSv2) and quantitative assessment (ADC metrics), in differentiating Gleason pattern (GP) 3 + 4 from the more aggressive GP 4 + 3 prostate cancer (PCa) using radical prostatectomy (RP) specimen as the reference standard. Methods: We retrospectively identified treatment-naïve peripheral (PZ) and transitional zone (TZ) Gleason Score 7 PCa patients who underwent multiparametric 3T prostate MRI (DWI with b value of 0,1400 and where unavailable, 0,500) and subsequent RP from 2011 to 2015. For each lesion identified on MRI, a PI-RADSv2 score was assigned by a radiologist blinded to pathology data. A PI-RADSv2 score ≤ 3 was defined as “low risk,” a PI-RADSv2 score ≥ 4 as “high risk” for clinically significant PCa. Mean tumor ADC (ADC{sub T}), ADC of adjacent normal tissue (ADC{sub N}), and ADC{sub ratio} (ADC{sub T}/ADC{sub N}) were calculated. Stepwise regression analysis using tumor location, ADC{sub T} and ADC{sub ratio}, b value, low vs. high PI-RADSv2 score was performed to differentiate GP 3 + 4 from 4 + 3. Results: 119 out of 645 cases initially identified met eligibility requirements. 76 lesions were GP 3 + 4, 43 were 4 + 3. ADC{sub ratio} was significantly different between the two GP groups (p = 0.001). PI-RADSv2 score (“low” vs. “high”) was not significantly different between the two GP groups (p = 0.17). Regression analysis selected ADC{sub T} (p = 0.03) and ADC{sub ratio} (p = 0.0007) as best predictors to differentiate GP 4 + 3 from 3 + 4. Estimated sensitivity, specificity, and accuracy of the predictive model in differentiating GP 4 + 3 from 3 + 4 were 37, 82, and 66%, respectively. Conclusions: ADC metrics could differentiate GP 3 + 4 from 4 + 3 PCa with high specificity and moderate accuracy while PI-RADSv2, did not differentiate between these patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Insights into scale translation of methane transport in nanopores

Accurate prediction of flow behavior in shale matrix is critical for efficient development of shale gas reservoirs. In these systems, the majority of pores are in the nano-size range. As a result, continuum-based approaches may not be appropriate to simulate flow in such systems. Molecular dynamics (MD) simulations are capable of capturing the relevant microscale physics. Their relatively high computational expense, however, restricts MD simulations to rather small systems and domains. This limitation creates a gap between computational need of macroscale systems and capabilities of MD simulations. The lattice Boltzmann method (LBM) is a suitable candidate to bridge this gap. In this work, the multiple-relaxation-time (MRT)-LBM is used to study methane transport in nano-size pores. Adsorption effects near solid boundaries, as well as non-ideal behavior of fluids, are accounted for via incorporating appropriate force terms in LBM. In this work, parameters associated with the force terms in the equation of state are studied in detail, and a workflow is proposed to determine optimal values of these parameters for gas flow in slit pores. Specifically, we establish these parameters such that the range of density values that the model is able to simulate is maximized. We demonstrate this workflow by simulating gas flow where velocity and density profiles from MD simulations are used as reference data. Results from LBM simulations are in good agreement with MD reference data for pores that are 4 nm in width or larger. Moreover, we propose a preconditioning scheme to improve the stability of LBM in dealing with complex geometries. The robustness of this scheme is demonstrated by simulating several roughness geometries. This work motivates the use of LBM in scale translation of the physics of mass transport in more complex permeable media.

03 NATURAL GAS↗

Structure-Based Analysis of Semisynthetic Anti-TB Rufomycin Analogues

This study employed structural information from cocrystals of rufomycin 4 (1a) and caseinolytic protein C1 (ClpC1)-NTD-wt to guide design and semisynthesis of rufomycin analogues, evaluate their antituberculosis (TB) biological profiles, and establish structure–activity relationships (SAR). Covering three regions of interest (ROIs, A–C) as modification sites, 14 of the 30 semisynthetic analogues (2–31) showed similar or improved MICs relative to the main natural precursors, rufomycins 4/6 (1a/b). Compounds 5 and 27 exhibited up to 10-fold enhanced potency against Mycobacterium tuberculosis (Mtb) in vitro, with MIC values of 1.9 and 1.4 nM, respectively. Evaluation of ClpC1-binding properties used existing ClpC1-NTD complexes with rufomycin 4 (PDB: 6cn8) and ecumicin (PDB: 6pbs) as references. The newly reported X-ray ClpC1-NTD cocrystal structure of 11 (syn. But4-Cl) revealed significant conformational effects involving the side chains of certain amino acids of the heptapeptide and confirmed the importance of ROIs A–C for medicinal chemistry efforts. Observed interactions of the N-terminal tail of ClpC1 with the rufomycin analogues vs ecumicin explains their different modes of inactivating the ClpC1/P1/P2 homeostatic machinery. Collectively, the observations inform further SAR optimization strategies for the rufomycin class of antibiotics and complement our understanding of their mode of action.

60 APPLIED LIFE SCIENCES↗

Detection of multi-reference character imbalances enables a transfer learning approach for virtual high throughput screening with coupled cluster accuracy at DFT cost

Appropriately identifying and treating molecules and materials with significant multi-reference (MR) character is crucial for achieving high data fidelity in virtual high-throughput screening (VHTS). Despite development of numerous MR diagnostics, the extent to which a single value of such a diagnostic indicates the MR effect on a chemical property prediction is not well established. We evaluate MR diagnostics for over 10 000 transition-metal complexes (TMCs) and compare to those for organic molecules. We observe that only some MR diagnostics are transferable from one chemical space to another. By studying the influence of MR character on chemical properties (i.e., MR effect) that involve multiple potential energy surfaces (i.e., adiabatic spin splitting, ΔE H–L , and ionization potential, IP), we show that differences in MR character are more important than the cumulative degree of MR character in predicting the magnitude of an MR effect. Motivated by this observation, we build transfer learning models to predict CCSD(T)-level adiabatic ΔE H–L and IP from lower levels of theory. By combining these models with uncertainty quantification and multi-level modeling, we introduce a multi-pronged strategy that accelerates data acquisition by at least a factor of three while achieving coupled cluster accuracy (i.e., to within 1 kcal mol –1 MAE) for robust VHTS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Balance of optical, structural, and electrical properties of textured liquid phase crystallized Si solar cells

Liquid phase crystallized Si thin-film solar cells on nanoimprint textured glass substrates exhibiting two characteristic, but distinct different surface structures are presented. The impact of the substrate texture on light absorption, the structural Si material properties, and the resulting solar cell performance is analyzed. A pronounced periodic substrate texture with a vertical feature size of about 1 μm enables excellent light scattering and light trapping. However, it also gives rise to an enhanced Si crystal defect formation deteriorating the solar cell performance. In contrast, a random pattern with a low surface roughness of 45 nm allows for the growth of Si thin films being comparable to Si layers on planar reference substrates. Amorphous Si/crystalline Si heterojunction solar cells fabricated on the low-roughness texture exhibit a maximum open circuit voltage of 616 mV and internal quantum efficiency peak values exceeding 90%, resulting in an efficiency potential of 13.2%. This demonstrates that high quality crystalline Si thin films can be realized on nanoimprint patterned glass substrates by liquid phase crystallization inspiring the implementation of tailor-made nanophotonic light harvesting concepts into future liquid phase crystallized Si thin film solar cells on glass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The velocity deviations of secondary electrons and the main condition of phase stability in two-sided multipactors

The conditions for secondary emission of electrons and the occurrence of discharge have been analyzed in detail with a plane-parallel model. According to the traditional theory of a resonance discharge (referred to as “simple resonance theory”), the velocity deviation of secondary electrons has no effect on multipactor (MP) zones. In this work, the effect of such deviations from resonance value in two-sided multipactors has been investigated using a different approach. In a previous study [M. Mostajeran and M. Lamehi Rachti, J. Instrum. 5, P08003 (2010)], a stability equation was derived considering only the phase deviation from the resonant phase. Here, the approach used in that paper has been extended to include velocity deviations as well. It is shown that phase and velocity deviations, which may not be considered small, support MP zones. Theoretical calculations are then compared with numerical results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scale translation yields insights into gas adsorption under nanoconfinement

This work describes a scale-translating simulation framework to investigate gas adsorption behavior in nanoconfined pores. The framework combines molecular simulations (MSs), equation of state (EoS), and lattice Boltzmann (LB) simulations. MSs reveal the physics of methane adsorption in nano-sized pores, where input values of fugacity coefficients are optimized based on EoS predictions. Then, an LB free-energy model, which incorporates a viral EoS, upscales intermolecular forces and estimates adsorption behavior via a proposed fluid–wall interaction model. Armed with the values of the LB interaction parameter as a function of pressure, the LB model is used to predict fluid behavior in irregular nanopores, and the results are validated against reference MS data. The LB model is then used to study adsorption behavior at a continuum scale in representative organic shale nanopores based on finely characterized Vaca Muerta shale samples. Furthermore, the results show that methane adsorption could significantly increase contained fluids by 10%–25% in pores smaller than 20 nm. However, in larger pores (40 nm to 90 nm), adsorption's impact diminishes to 2%–3%, suggesting sorption's negligible role beyond a 40 nm pore size.

74 ATOMIC AND MOLECULAR PHYSICS↗

Segmentation of pulmonary nodules in three-dimensional CT images by use of a spiral-scanning technique

Accurate segmentation of pulmonary nodules in computed tomography (CT) is an important and difficult task for computer-aided diagnosis of lung cancer. Therefore, the authors developed a novel automated method for accurate segmentation of nodules in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. To simplify nodule segmentation, the 3D VOI was transformed into a two-dimensional (2D) image by use of a key 'spiral-scanning' technique, in which a number of radial lines originating from the center of the VOI spirally scanned the VOI from the 'north pole' to the 'south pole'. The voxels scanned by the radial lines provided a transformed 2D image. Because the surface of a nodule in the 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified the segmentation method and enabled reliable segmentation results to be obtained. A dynamic programming technique was employed to delineate the 'optimal' outline of a nodule in the 2D image, which corresponded to the surface of the nodule in the 3D image. The optimal outline was then transformed back into 3D image space to provide the surface of the nodule. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric for evaluating the segmentation method. The database included two Lung Imaging Database Consortium (LIDC) data sets that contained 23 and 86 CT scans, respectively, with 23 and 73 nodules that were 3 mm or larger in diameter. For the two data sets, six and four radiologists manually delineated the outlines of the nodules as reference standards in a performance evaluation for nodule segmentation. The segmentation method was trained on the first and was tested on the second LIDC data sets. The mean overlap values were 66% and 64% for the nodules in the first and second LIDC data sets, respectively, which represented a higher performance level than those of two existing segmentation methods that were also evaluated by use of the LIDC data sets. The segmentation method provided relatively reliable results for pulmonary nodule segmentation and would be useful for lung cancer quantification, detection, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar Plus: A Holistic Approach to Distributed Solar PV

Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

14 SOLAR ENERGY↗

Solar Plus: A Holistic Approach to Distributed Solar PV

Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

14 SOLAR ENERGY↗

Atomic Data Revisions for Transitions Relevant to Observations of Interstellar, Circumgalactic, and Intergalactic Matter

Measurements of element abundances in galaxies from astrophysical spectroscopy depend sensitively on the atomic data used. With the goal of making the latest atomic data accessible to the community, we present a compilation of selected atomic data for resonant absorption lines at wavelengths longward of 911.753 Å (the H i Lyman limit), for key heavy elements (heavier than atomic number 5) of astrophysical interest. In particular, we focus on the transitions of those ions that have been observed in the Milky Way interstellar medium (ISM), the circumgalactic medium (CGM) of the Milky Way and/or other galaxies, and the intergalactic medium (IGM). We provide wavelengths, oscillator strengths, associated accuracy grades, and references to the oscillator strength determinations. We also attempt to compare and assess the recent oscillator strength determinations. For about 22% of the lines that have updated oscillator strength values, the differences between the former values and the updated ones are ≳0.1 dex. Our compilation will be a useful resource for absorption line studies of the ISM, as well as studies of the CGM and IGM traced by sight lines to quasars and gamma-ray bursts. Studies (including those enabled by future generations of extremely large telescopes) of absorption by galaxies against the light of background galaxies will also benefit from our compilation.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic imaging using poissonian detector data

An image reconstruction method for reconstructing a tomographic image (f.sub.j) of a region of investigation within an object (1), comprises the steps of providing detector data (y.sub.i) comprising Poisson random values measured at an i-th of a plurality of different positions, e.g. i=(k,l) with pixel index k on a detector device and angular index l referring to both the angular position (.alpha..sub.l) and the rotation radius (r.sub.l) of the detector device (10) relative to the object (1), providing a predetermined system matrix A.sub.ij assigning a j-th voxel of the object (1) to the i-th detector data (y.sub.i), and reconstructing the tomographic image (f.sub.j) based on the detector data (y.sub.i), said reconstructing step including a procedure of minimizing a functional F(f) depending on the detector data (y.sub.i) and the system matrix A.sub.ij and additionally including a sparse or compressive representation of the object (1) in an orthobasis T, wherein the tomographic image (f.sub.j) represents the global minimum of the functional F(f). Furthermore, an imaging method and an imaging device using the image reconstruction method are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗