Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Microfabricated fuel heating value monitoring device

A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

47 OTHER INSTRUMENTATION↗

SU-E-T-665: Radiochromic Film Quenching Effect Reduction for Proton Beam Dosimetry

Purpose: Depending on the useful dose range in which radiochromic films operate, number of different radiochromic film models have been designed. The impact of different film models on quenching effect for percent depth dose (PDD) measurements in proton beams has been investigated. Methods: Calibrated PTW Markus ionization chamber was used to measure PDD and beam output for 26.5 MeV protons produced by CS30 cyclotron. An aluminum cylinder was added in front of the beam exit serving as a radiation shutter. The measured signal was normalized to a monitor chamber reading and subsequently scaled by ratio of water-to-air stopping powers at given depth, while the effective depth of measurements was scaled by ratios of material-to-water physical densities and CSDA ranges. Output was measured in water at 2.1 mm reference-depth in the plateau upstream from the Bragg peak. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water. Three radiochromic film models (EBT, EBT3 and HD-V2) were calibrated within Lexan phantom positioned at the same water-equivalent depth. Thicknesses of films sensitive layers were 34 µm, 30 µm and 8 µm, respectively. Small film pieces (1 x 2 cm{sup 2}) were positioned within polyethylene phantom along the beam central axis with an angulation of 5° for PDD measurements. Results: While the output of the proton beam was found to be around 7 Gy/sec, the actual value of the output per monitor chamber reading (2.32 Gy/nC) was used for reference-dose irradiations during film calibration. Dose ratios at the Bragg peak relative to the reference-depth were 3.88, 2.52, 2.19, and 2.02 for the Markus chamber, HD-V2, EBT3, and EBT film models, respectively. Conclusion: Results at hand suggest that quenching effect is reduced when a radiochromic film model with smaller sensitive layer thickness is used for PDD measurements in proton beams. David Lewis is the owner of RCF Consulting, LLC.

07 ISOTOPE AND RADIATION SOURCES↗

Real-time garbage collection for list processing

In a list processing system, small reference counters are maintained in conjunction with memory cells for the purpose of identifying memory cells that become available for re-use. The counters are updated as references to the cells are created and destroyed, and when a counter of a cell is decremented to logical zero the cell is immediately returned to a list of free cells. In those cases where a counter must be incremented beyond the maximum value that can be represented in a small counter, the cell is restructured so that the additional reference count can be represented. The restructuring involves allocating an additional cell, distributing counter, tag, and pointer information among the two cells, and linking both cells appropriately into the existing list structure.

Shuler, R. L., Jr.↗

Real-time garbage collection for list processing using restructured cells for increased reference counter size

In a list processing system, small reference counters are maintained in conjunction with memory cells for the purpose of identifying memory cells that become available for re-use. The counters are updated as references to the cells are created and destroyed, and when a counter of a cell is decremented to logical zero the cell is immediately returned to a list of free cells. In those cases where a counter must be incremented beyond the maximum value that can be represented in a small counter, the cell is restructured so that the additional reference count can be represented. The restructuring involves allocating an additional cell, distributing counter, tag, and pointer information among the two cells, and linking both cells appropriately into the existing list structure.

Shuler, Jr., Robert L.↗

Draft genome sequence of type strain HBR26T and description of Rhizobium aethiopicum sp. nov.

Rhizobium aethiopicum sp. nov. is a newly proposed species within the genus Rhizobium. This species includes six rhizobial strains; which were isolated from root nodules of the legume plant Phaseolus vulgaris growing in soils of Ethiopia. The species fixes nitrogen effectively in symbiosis with the host plant P. vulgaris, and is composed of aerobic, Gram-negative staining, rod-shaped bacteria. The genome of type strain HBR26 T of R. aethiopicum sp. nov. was one of the rhizobial genomes sequenced as a part of the DOE JGI 2014 Genomic Encyclopedia project designed for soil and plant-associated and newly described type strains. The genome sequence is arranged in 62 scaffolds and consists of 6,557,588 bp length, with a 61% G + C content and 6221 protein-coding and 86 RNAs genes. The genome of HBR26 T contains repABC genes (plasmid replication genes) homologous to the genes found in five differen t Rhizobium etli CFN42 T plasmids, suggesting that HBR26 T may have five additional replicons other than the chromosome. In the genome of HBR26 T , the nodulation genes nodB, nodC, nodS, nodI, nodJ and nodD are located in the same module, and organized in a similar way as nod genes found in the genome of other known common bean-nodulating rhizobial species. nodA gene is found in a different scaffold, but it is also very similar to nodA genes of other bean-nodulating rhizobial strains. Though HBR26 T is distinct on the phylogenetic tree and based on ANI analysis (the highest value 90.2% ANI with CFN42 T ) from other bean-nodulating species, these nod genes and most nitrogen-fixing genes found in the genome of HBR26 T share high identity with the corresponding genes of known bean-nodulating rhizobial species (96-100% identity). This suggests that symbiotic genes might be shared between bean-nodulating rhizobia through horizontal gene transfer. R. aethiopicum sp. nov. was grouped into the genus Rhizobium but was distinct from all recognized species of that genus by phylogenetic analyses of combined sequences of the housekeeping genes recA and glnII. The closest reference type strains for HBR26 T were R. etli CFN42 T (94% similarity of the combined recA and glnII sequences) and Rhizobium bangladeshense BLR175 T (93%). Genomic ANI calculation based on protein-coding genes also revealed that the closest reference strains were R. bangladeshense BLR175 T and R. etli CFN42 T with ANI values 91.8 and 90.2%, respectively. Nevertheless, the ANI values between HBR26 T and BLR175 T or CFN42 T are far lower than the cutoff value of ANI ( > = 96%) between strains in the same species, confirming that HBR26 T belongs to a novel species. Thus, on the basis of phylogenetic, comparative genomic analyses and ANI results, we formally propose the creation of R. aethiopicum sp. nov. with strain HBR26 T (=HAMBI 3550 T =LMG 29711 T ) as the type strain. The genome assembly and annotation data is deposited in the DOE JGI portal and also available at European Nucleotide Archive under accession numbers FMAJ01000001-FMAJ01000062.

59 BASIC BIOLOGICAL SCIENCES↗

TH-A-204-00: Key Dosimetry Data - Impact of New ICRU Recommendations

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV xrays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

07 ISOTOPE AND RADIATION SOURCES↗

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

Challenges and Opportunities for Transactive Control of Electric Vehicle Supply Equipment. A Reference Guide

This report seeks to characterize the opportunities and challenges that arise in developing a transactive control strategy for grid-EVSE integration in various use-case scenarios in a way that provides end-user, energy market, grid, and societal benefits. A detailed review provides information about EVSE integration market trends and stakeholder activities. This is followed by an exploration of value proposition for transactive control of EVSE at both the home scale and the building/campus scale. This report will serve as a reference guide for stakeholders in the grid-EVSE integration area, illustrate potential implementations, and identify a high-value research project for overcoming the barriers and unlocking the benefits of transactive controls of EVSE. While it is not intended to specify the technical details of the transactive control solution, the report contains a list of use cases describing potential applications of transactive control of EVSE, barriers to implementing these applications, and research and development (R&D) opportunities to overcome the barriers. The use cases of transactive control of EVSE are listed in Table ES1.

33 ADVANCED PROPULSION SYSTEMS↗

Photophysical Properties and Electronic Structure of Porphyrins Bearing Zero to Four meso -Phenyl Substituents: New Insights into Seemingly Well Understood Tetrapyrroles

Six free base porphyrins bearing 0–4 meso substituents have been examined by steady-state and time-resolved absorption and fluorescence spectroscopy in both toluene and N,N-dimethylformamide (DMF). The lifetime of the lowest singlet excited state (S 1 ) decreases with an increase in the number of meso-phenyl groups; the values in toluene are H 2 P-0 (15.5 ns) > H 2 P-1 (14.9 ns) > H 2 P-2c (14.4 ns) > H 2 P-2t (13.8 ns) ~ H 2 P-3 (13.8 ns) > H 2 P-4 (12.8 ns), where “H 2 P” refers to the core free base porphyrin, the numerical suffix indicates the number of meso-phenyl groups, and “c” and “t” refer to cis and trans, respectively. The opposite trend is found for the fluorescence quantum yield; the values in toluene are H 2 P-0 (0.049) < H 2 P-1 (0.063) ~ H 2 P-2c (0.063) < H 2 P-2t (0.071) < H 2 P-3 (0.073) < H 2 P-4 (0.090). Similar trends occur in DMF. All radiative and non-radiative (internal conversion and intersystem crossing) rate constants for S 1 decay increase with increasing number of meso-phenyl groups. The increase in the rate constant for fluorescence parallels an increase in oscillator strength of the S o → S 1 absorption manifold. Here, the trend is reproduced by time-dependent density functional theory calculations. The calculations within the context of the four-orbital model reveal that the enhanced S o → S 1 radiative probabilities derive from a preferential effect of the meso-phenyl groups to raise the energy of the highest occupied molecular orbital, which underpins a parallel bathochromic shift in the S o → S 1 absorption wavelength. Polarizations of the S 1 and S 2 excited states with respect to molecular structural features (e.g., the central proton axis) are analyzed in the context of historical conventions for porphyrins versus chlorins and bacteriochlorins, where some ambiguity exists, including for porphine, one of the simplest tetrapyrroles. Collectively, the study affords fundamental insights into the photophysical properties and electronic structure of meso-phenylporphyrins that should aid their continued widespread use as benchmarks for tetrapyrrole-based architectures in chemical, solar-energy and life-sciences research.

14 SOLAR ENERGY↗

Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.

60 APPLIED LIFE SCIENCES↗

Characterization of Low Noise, Precision Voltage Reference REF5025-HT Under Extreme Temperatures

The performance of Texas Instruments precision voltage reference REF5025-HT was assessed under extreme temperatures. This low noise, 2.5 V output chip is suitable for use in high temperature down-hole drilling applications, but no data existed on its performance at cryogenic temperatures. The device was characterized in terms of output voltage and supply current at different input voltage levels as a function of temperature between +210 C and -190 C. Line and load regulation characteristics were also established at six load levels and at different temperatures. Restart capability at extreme temperatures and the effects of thermal cycling, covering the test temperature range, on its operation and stability were also investigated. Under no load condition, the voltage reference chip exhibited good stability in its output over the temperature range of -50 C to +200 C. Outside that temperature range, output voltage did change as temperature was changed. For example, at the extreme temperatures of +210 C and - 190 C, the output level dropped to 2.43 V and 2.32 V, respectively as compared to the nominal value of 2.5 V. At cryogenic test temperatures of -100 C and -150 C the output voltage dropped by about 20%. The quiescent supply current of the voltage reference varied slightly with temperature but remained close to its specified value. In terms of line regulation, the device exhibited excellent stability between -50 C and +150 C over the entire input voltage range and load levels. At the other test temperatures, however, while line regulation became poor at cryogenic temperatures of -100 C and below, it suffered slight degradation at the extreme high temperature but only at the high load level of 10 mA. The voltage reference also exhibited very good load regulation with temperature down to -100 C, but its output dropped sharply at +210 C only at the heavy load of 10 mA. The semiconductor chip was able restart at the extreme temperatures of -190 C and +210 C, and the limited thermal cycling did not influence its characteristics and had no impact on its packaging as no structural or physical damage was observed.

Patterson, Richard↗

Coulomb excitation of radioactive {sup 21}Na and its stable mirror {sup 21}Ne

The low-energy structures of the mirror nuclei {sup 21}Ne and radioactive {sup 21}Na have been examined by using Coulomb excitation at the TRIUMF-ISAC radioactive ion beam facility. Beams of {approx}5x10{sup 6} ions/s were accelerated to 1.7 MeV/A and Coulomb excited in a 0.5 mg/cm{sup 2} {sup nat}Ti target. Scattered beam and target particles were detected by the segmented Si detector BAMBINO, while {gamma} rays were observed by using two TIGRESS HPGe clover detectors perpendicular to the beam axis. For each isobar, Coulomb excitation from the (3/2){sup +} ground state to the first excited (5/2){sup +} state was observed and B(E2) values were determined by using the 2{sup +}{yields}0{sup +} de-excitation in {sup 48}Ti as a reference. The {phi} segmentation of BAMBINO was used to deduce tentative assignments for the signs of the mixing ratios between the E2 and M1 components of the transitions. The resulting B(E2){up_arrow} values are 131{+-}9 e{sup 2} fm{sup 4} (25.4{+-}1.7 W.u.) for {sup 21}Ne and 205{+-}14 e{sup 2} fm{sup 4} (39.7{+-}2.7 W.u.) for {sup 21}Na. The fit to the present data and the known lifetimes determined E2/M1 mixing ratios and B(M1){down_arrow} values of {delta}=(-)0.0767{+-}0.0027 and 0.1274{+-}0.0025 {mu}{sub N}{sup 2} and {delta}=(+)0.0832{+-}0.0028 and 0.1513{+-}0.0017 {mu}{sub N}{sup 2} for {sup 21}Ne and {sup 21}Na, respectively (with Krane and Steffen sign convention). By using the effective charges e{sub p}=1.5e and e{sub n}=0.5e, the B(E2) values produced by the p-sd shell model are 30.7 and 36.4 W.u. for {sup 21}Ne and {sup 21}Na, respectively. This analysis resolves a significant discrepancy between a previous experimental result for {sup 21}Na and shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Properties of Perovskite Manganese Oxides Pr{sub 1−x}Ba{sub x}MnO{sub 3}

The critical properties of polycrystalline Pr{sub 1−x}Ba{sub x}MnO{sub 3} (x = 0.13 and 0.23) samples prepared by using a standard ceramic fabrication method were investigated. Pr{sub 1−x}Ba{sub x}MnO{sub 3} exhibited a second-order magnetic transition. As per the modified Arrott plot method and double logarithmic M-μ{sub 0}H curve, the critical exponents (CE) were calculated as β = 0.459 ± 0.03, γ = 1.346 ± 0.02, δ = 4.32 ± 0.04, and T{sub C} ≈ 130 K, for x = 0.13, and β = 0.424 ± 0.03, γ = 1.362 ± 0.02, δ = 4.19. ± 0.03, and T{sub C} ≈ 163 K, for x = 0.23. To confirm the reliability of such CE values, the M (H) data of Pr{sub 1−x}Ba{sub x}MnO{sub 3} were checked by the scaling equation M(H, t) = |t|{sup β}f{sub ±}(H/|t|{sup β + γ}), where t=(T/(T{sub C}))−1 refers to the reduced temperature, f{sub ±} is the scaling function above (+)/below (−) T{sub C}. The β values for Pr{sub 1−x}Ba{sub x}MnO{sub 3} (x = 0.13 and 0.23) are between β = 0.365 (3D Heisenberg exponent) and β = 0.5 (mean-field exponent), whereas γ values are fairly close to γ = 1.386. This reveals long- and short-range order coexisting in Pr{sub 1−x}Ba{sub x}MnO{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PIXiE: an algorithm for automated ion mobility arrival time extraction and collision cross section calculation using global data association

Abstract Motivation Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of data that can then be used to create a reference library of experimental CCS values for use in high throughput omics analyses. Results We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. Availability and implementation PIXiE is an open-source tool, freely available on Github. The documentation, source code of the software, and a GUI can be found at https://github.com/PNNL-Comp-Mass-Spec/PIXiE and the source code of the backend workflow library used by PIXiE can be found at https://github.com/PNNL-Comp-Mass-Spec/IMS-Informed-Library. Supplementary information Supplementary data are available at Bioinformatics online.

Ma, Jian↗

FY 2021 Isolated Grids and Grid-Connected Turbine Reference Systems; Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project is a multi-year distributed wind research effort, driven through a partnership between four Department of Energy National Laboratories and industry to develop and improve the planning, design, and operation of wind-centered microgrids to complement solar, energy storage, and other distributed energy resources for grid-tied and isolated operation (U.S. Department of Energy, 2021). This report documents the application of methods developed through the initial three years of the MIRACL project to two real-world distributed wind reference systems. Specifically, the methods demonstrated in this report include 1) a market valuation framework to comprehensively value the services distributed wind can provide and 2) a resilience framework that enables stakeholders to characterize distribution system resilience and compare grid investment decisions from a resilience perspective. Additional methods mentioned in this report include distributed hybrid system design methods for grid resilience, advanced control co-simulation platforms, and power hardware-in-the-loop (PHIL) models. Preliminary results from these additional methods are presented in this report and will be demonstrated and/or applied to the reference systems in the coming year. The purpose of applying these methods to reference systems is to drive technology transfer of the theories, methodologies, and technologies developed under the MIRACL project and increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply (i.e. kilowatt-hours).

17 WIND ENERGY↗

Status of Venus Global Reference Atmospheric Model (Venus-GRAM) Upgrades

Venus-GRAM Overview - Engineering-oriented atmospheric model that estimates mean values and statistical variations of Venus atmospheric properties - Outputs include atmospheric density, temperature, pressure, chemical composition, and wind components along a user-defined path - Widely used by the engineering community because of its ability to create realistic atmospheric dispersions - Can be integrated into high fidelity flight dynamic simulations of launch, entry, descent and landing (EDL), aerobraking and aerocapture - Has been used in multiple studies and proposals including NASA Engineering and Safety Center (NESC) Autonomous Aerobraking Study and various Discovery proposals - Optional trajectory input file consisting of time, height, latitude, and longitude can be used to provide the Venus-GRAM trajectory path - Optional auxiliary profile consisting of height, latitude, longitude, temperature, pressure, density, eastward wind, and northward wind may be used to replace model data in Venus-GRAM - Not a forecast model - GRAMs are also available for Earth, Mars, Titan, Neptune, Uranus, and Jupiter - Available through the NASA Software Catalog https://software.nasa.gov/software/MFS-33888-1

atmospheric models↗

Thin Co/Ni-based bottom pinned spin-transfer torque magnetic random access memory stacks with high annealing tolerance

Spin-transfer torque magnetic random access memory (STT-MRAM) is considered as a replacement for next generation embedded and stand-alone memory applications. One of the main challenges in the STT-MRAM stack development is the compatibility of the stack with CMOS process flows in which thermal budgets up to 400 °C are applied. In this letter, we report on a perpendicularly magnetized MgO-based tunnel junction (p-MTJ) on a thin Co/Ni perpendicular synthetic antiferromagnetic layer with high annealing tolerance. Tunnel magneto resistance (TMR) loss after annealing occurs when the reference layer loses its perpendicular magnetic anisotropy due to reduction of the CoFeB/MgO interfacial anisotropy. A stable Co/Ni based p-MTJ stack with TMR values of 130% at resistance-area products of 9 Ω μm{sup 2} after 400 °C anneal is achieved via moment control of the Co/Ta/CoFeB reference layer. Thinning of the CoFeB polarizing layer down to 0.8 nm is the key enabler to achieve 400 °C compatibility with limited TMR loss. Thinning the Co below 0.6 nm leads to a loss of the antiferromagnetic interlayer exchange coupling strength through Ru. Insight into the thickness and moment engineering of the reference layer is displayed to obtain the best magnetic properties and high thermal stability for thin Co/Ni SAF-based STT-MRAM stacks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SCIENCE PARAMETRICS FOR MISSIONS TO SEARCH FOR EARTH-LIKE EXOPLANETS BY DIRECT IMAGING

We use N{sub t} , the number of exoplanets observed in time t, as a science metric to study direct-search missions like Terrestrial Planet Finder. In our model, N has 27 parameters, divided into three categories: 2 astronomical, 7 instrumental, and 18 science-operational. For various ''27-vectors'' of those parameters chosen to explore parameter space, we compute design reference missions to estimate N{sub t} . Our treatment includes the recovery of completeness c after a search observation, for revisits, solar and antisolar avoidance, observational overhead, and follow-on spectroscopy. Our baseline 27-vector has aperture D = 16 m, inner working angle IWA = 0.039'', mission time t = 0-5 yr, occurrence probability for Earth-like exoplanets η = 0.2, and typical values for the remaining 23 parameters. For the baseline case, a typical five-year design reference mission has an input catalog of ∼4700 stars with nonzero completeness, ∼1300 unique stars observed in ∼2600 observations, of which ∼1300 are revisits, and it produces N {sub 1} ∼ 50 exoplanets after one year and N {sub 5} ∼ 130 after five years. We explore offsets from the baseline for 10 parameters. We find that N depends strongly on IWA and only weakly on D. It also depends only weakly on zodiacal light for Z < 50 zodis, end-to-end efficiency for h > 0.2, and scattered starlight for ζ < 10{sup –10}. We find that observational overheads, completeness recovery and revisits, solar and antisolar avoidance, and follow-on spectroscopy are all important factors in estimating N.

79 ASTRONOMY AND ASTROPHYSICS↗