At least 1,279 records · Page 71

The effect of respiratory cycle and radiation beam-on timing on the dose distribution of free-breathing breast treatment using dynamic IMRT

In breast cancer treatment, intensity-modulated radiation therapy (IMRT) can be utilized to deliver more homogeneous dose to target tissues to minimize the cosmetic impact. We have investigated the effect of the respiratory cycle and radiation beam-on timing on the dose distribution in free-breathing dynamic breast IMRT treatment. Six patients with early stage cancer of the left breast were included in this study. A helical computed tomography (CT) scan was acquired for treatment planning. A four-dimensional computed tomography (4D CT) scan was obtained right after the helical CT scan with little or no setup uncertainty to simulate patient respiratory motion. After optimizing based on the helical CT scan, the sliding-window dynamic multileaf collimator (DMLC) leaf sequence was segmented into multiple sections that corresponded to various respiratory phases per respiratory cycle and radiation beam-on timing. The segmented DMLC leaf sections were grouped according to respiratory phases and superimposed over the radiation fields of corresponding 4D CT image set. Dose calculation was then performed for each phase of the 4D CT scan. The total dose distribution was computed by accumulating the contribution of dose from each phase to every voxel in the region of interest. This was tracked by a deformable registration program throughout all of the respiratory phases of the 4D CT scan. A dose heterogeneity index, defined as the ratio between (D{sub 20}-D{sub 80}) and the prescription dose, was introduced to numerically illustrate the impact of respiratory motion on the dose distribution of treatment volume. A respiratory cycle range of 4-8 s and randomly distributed beam-on timing were assigned to simulate the patient respiratory motion during the free-breathing treatment. The results showed that the respiratory cycle period and radiation beam-on timing presented limited impact on the target dose coverage and slightly increased the target dose heterogeneity. This motion impact tended to increase the variation of target dose coverage and heterogeneity between treatment fractions with different radiation beam-on timing. The target dose coverage and heterogeneity were more susceptible to the radiation beam-on timing for patients with long respiratory cycle (longer than 6 s) and large breast motion amplitudes (larger than 0.7 cm). The same results could be found for respiratory cycle up to 8 s and respiratory motion amplitude up to 1 cm. The heart dose distribution did not change significantly regardless of respiratory cycle and radiation beam-on timing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Material Response of One-Dimensional, Steady-State Transpiration Cooling in Radiative and Convective Environments

A simplified analytical solution for thermal response of a transpiration-cooled porous heat-shield material in an intense radiative-convective heating environment is presented. Essential features of this approach are "two-flux method" for radiative transfer process and "two-temperature" assumption for solid and gas temperatures. Incident radiative-convective heatings are specified as boundary conditions. Sample results are shown using porous silica with CO2 transpiration and some parameters quantitatively show the effect on this transpiration cooling system. Summarized maps for mass injection rate, porosity and blowing correction factor for radiation are obtained in order to realize such a cooling system.

Kubota, Hirotoshi↗

Are Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm Applicable to Other Malignancies—Assessment of Nodal Distribution in Gynecological Malignancies

Purpose: Intensity modulated radiation therapy is used to reduce dose to adjacent critical structures while maintaining adequate target coverage, but it requires precise target localization. We report the 3-dimensional distribution of para-aortic (PA) lymph nodes (LN) in pelvic malignancies. We propose a guideline to accurately define the PA LN by anatomic landmarks and compare our data with published guidelines for pancreatic cancer. Methods and Materials: A retrospective analysis was performed on 46 patients with pelvic malignancies and positive PA LNs. Positive LNs were defined based on size and morphology or fluorodeoxyglucose avidity. All PA LNs were characterized into 3 groups based on location: left PA (between aorta and left psoas muscle), aortocaval (between aorta and inferior vena cava), and right paracaval (between inferior vena cava and right psoas muscle). Patients with retrocrural LNs were also analyzed. Results: One hundred thirty-three positive PA LNs were evaluated. The majority of the PA LNs were in the left PA (59%) and aortocaval (35) regions, and only 8% were in the right paracaval region. All patients with positive right paracaval LNs also had involved left PA LNs, with only 1 exception. The highest PA LN involvement was at the level of the renal vessels and was seen in 28% of patients. Of these patients with disease extending to renal vessels, 38% had retrocrural LN involvement. Conclusions: The nodal contouring for the PA region should not be defined by a fixed circumferential margin around the vessels. The left PA and aortocaval spaces should be covered adequately because these are common locations of PA LNs. For microscopic disease superiorly, contouring should extend up to renal vessels rather than a fixed bony landmark. For patients who have nodal involvement at renal vessels, one can consider including retrocrural LNs. Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm are not applicable to gynecological malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximizing the probability of satisfying the clinical goals in radiation therapy treatment planning under setup uncertainty

Purpose: This paper introduces a method that maximizes the probability of satisfying the clinical goals in intensity-modulated radiation therapy treatments subject to setup uncertainty. Methods: The authors perform robust optimization in which the clinical goals are constrained to be satisfied whenever the setup error falls within an uncertainty set. The shape of the uncertainty set is included as a variable in the optimization. The goal of the optimization is to modify the shape of the uncertainty set in order to maximize the probability that the setup error will fall within the modified set. Because the constraints enforce the clinical goals to be satisfied under all setup errors within the uncertainty set, this is equivalent to maximizing the probability of satisfying the clinical goals. This type of robust optimization is studied with respect to photon and proton therapy applied to a prostate case and compared to robust optimization using an a priori defined uncertainty set. Results: Slight reductions of the uncertainty sets resulted in plans that satisfied a larger number of clinical goals than optimization with respect to a priori defined uncertainty sets, both within the reduced uncertainty sets and within the a priori, nonreduced, uncertainty sets. For the prostate case, the plans taking reduced uncertainty sets into account satisfied 1.4 (photons) and 1.5 (protons) times as many clinical goals over the scenarios as the method taking a priori uncertainty sets into account. Conclusions: Reducing the uncertainty sets enabled the optimization to find better solutions with respect to the errors within the reduced as well as the nonreduced uncertainty sets and thereby achieve higher probability of satisfying the clinical goals. This shows that asking for a little less in the optimization sometimes leads to better overall plan quality.

07 ISOTOPE AND RADIATION SOURCES↗

A simplified analytical solution for thermal response of a one-dimensional, steady state transpiration cooling system in radiative and convective environment

A simplified analytical method for calculation of thermal response within a transpiration-cooled porous heat shield material in an intense radiative-convective heating environment is presented. The essential assumptions of the radiative and convective transfer processes in the heat shield matrix are the two-temperature approximation and the specified radiative-convective heatings of the front surface. Sample calculations for porous silica with CO2 injection are presented for some typical parameters of mass injection rate, porosity, and material thickness. The effect of these parameters on the cooling system is discussed.

Kubota, H.↗

A radiation-hardened star scanner for spacecraft guidance and control

A star scanner for the Galileo Project is described. Because it must function in the intense Jupiter radiation field, which consists primarily of high-energy electrons and protons, this star scanner is designed with radiation-hardness as a prime objective. The optics and the multiplier phototube are specially designed to minimize fluorescence and Cerenkov effects, and the electronic components to minimize ionization and displacement damage. The star-scanner layout provides maximum shielding for the optics and phototube. Test results predict successful operation in the expected Jovian radiation environment.

Birnbaum, M. M.↗

Elective Nodal Irradiation and Patterns of Failure in Head and Neck Cancer After Primary Radiation Therapy

Purpose: The delineation of elective clinical target volumes in head and neck cancer (HNC) is important; however, the extent of lymph node levels necessary to include is debated. A comprehensive analysis of recurrence patterns in a large cohort of patients with HNC was performed, with an emphasis on recurrence in the retropharyngeal region and level IB. Methods and Materials: From 2005 to 2012, 942 patients with oropharyngeal, hypopharyngeal, laryngeal or oral cavity carcinomas were curatively treated with primary radiation therapy. The median follow-up period was 34 months, and 77% of the patients underwent intensity modulated radiation therapy. The retropharyngeal region was only routinely included in cases of involvement of the posterior pharynx wall and level IB only in cases of involvement of the oral cavity. In patients with regional recurrence, the anatomic site of the recurrence was assessed from the surgical descriptions or computed tomography scans and compared with the original radiation treatment plan (available from 2007 onward). The p16 status was available for 282 oropharynx carcinoma cases, with 65% p16-positive. Results: Of the 942 patients, 376 (40%) developed recurrences: 228 (24.2%) local, 123 (13.1%) regional, and 109 (11.6%) distant. In 700 patients with available treatment plans, retropharyngeal and level IB recurrence was observed in 2 and 7 patients, respectively. Eight patients (1.1%) had recurrence in a lymph node level not included in their primary treatment plan. For oropharynx carcinoma, the locoregional control rate (90% vs 70%) but not distant control rate (92% vs 87%), was significantly better in the p16-positive than in the p16-negative patients. Although fewer recurrences developed in the p16-positive group, patients with recurrence of p16-positive tumors were more likely to develop recurrence in distant sites. Conclusions: Retropharyngeal or level IB recurrence after primary HNC radiation therapy is rare. Thus, inclusion of these regions in the elective treatment volumes should be limited to patients with involvement of the posterior pharyngeal wall or oral cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A detailed evaluation of TomoDirect 3DCRT planning for whole-breast radiation therapy

The goal of this work was to develop planning strategies for whole-breast radiotherapy (WBRT) using TomoDirect three-dimensional conformal radiation therapy (TD-3DCRT) and to compare TD-3DCRT with conventional 3DCRT and TD intensity-modulated radiation therapy (TD-IMRT) to evaluate differences in WBRT plan quality. Computed tomography (CT) images of 10 women were used to generate 150 WBRT plans, varying in target structures, field width (FW), pitch, and number of beams. Effects on target and external maximum doses (EMD), organ-at-risk (OAR) doses, and treatment time were assessed for each parameter to establish an optimal planning technique. Using this technique, TD-3DCRT plans were generated and compared with TD-IMRT and standard 3DCRT plans. FW 5.0 cm with pitch = 0.250 cm significantly decreased EMD without increasing lung V20 Gy. Increasing number of beams from 2 to 6 and using an additional breast planning structure decreased EMD though increased lung V20 Gy. Changes in pitch had minimal effect on plan metrics. TD-3DCRT plans were subsequently generated using FW 5.0 cm, pitch = 0.250 cm, and 2 beams, with additional beams or planning structures added to decrease EMD when necessary. TD-3DCRT and TD-IMRT significantly decreased target maximum dose compared to standard 3DCRT. FW 5.0 cm with 2 to 6 beams or novel planning structures or both allow for TD-3DCRT WBRT plans with excellent target coverage and OAR doses. TD-3DCRT plans are comparable to plans generated using TD-IMRT and provide an alternative to conventional 3DCRT for WBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Dosimetric Impact of Prostate Rotations During Electromagnetically Guided External-Beam Radiation Therapy

Purpose: To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). Methods and Materials: Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation therapy plans meeting RTOG 0126 dosimetric criteria were created with 0-, 2-, 3-, and 5-mm planning target volume (PTV) margins. Daily translations and rotations were used to reconstruct prostate delivered dose from the planned dose. D{sub 95} and V{sub 79} were computed from the delivered dose to evaluate target coverage and the adequacy of PTV margins. Prostate equivalent rotation is a new metric introduced in this study to quantify prostate rotations by accounting for prostate shape and length of rotational lever arm. Results: Large variations in prostate delivered dose were seen among patients. Adequate target coverage was met in 39%, 65%, and 84% of the patients for plans with 2-, 3-, and 5-mm PTV margins, respectively. Although no correlations between prostate delivered dose and daily rotations were seen, the data showed a clear correlation with prostate equivalent rotation. Conclusions: Prostate rotations during RT could cause significant underdosing even if daily translations were managed. These rotations should be managed with rotational tolerances based on prostate equivalent rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Radiation Therapy (66 Gy in 22 Fractions at 3 Gy per Fraction) for Favorable-Risk Prostate Cancer: Long-term Outcomes

Purpose: To report long-term outcomes of low- and intermediate-risk prostate cancer patients treated with high-dose hypofractionated radiation therapy (HypoRT). Methods and Materials: Patients with low- and intermediate-risk prostate cancer were treated using 3-dimensional conformal radiation therapy to a dose of 66 Gy in 22 daily fractions of 3 Gy without hormonal therapy. A uniform 7-mm margin was created around the prostate for the planning target volume, and treatment was prescribed to the isocenter. Treatment was delivered using daily ultrasound image-guided radiation therapy. Common Terminology Criteria for Adverse Events, version 3.0, was used to prospectively score toxicity. Biochemical failure was defined as the nadir prostate-specific antigen level plus 2 ng/mL. Results: A total of 129 patients were treated between November 2002 and December 2005. With a median follow-up of 90 months, the 5- and 8-year actuarial biochemical control rates were 97% and 92%, respectively. The 5- and 8-year actuarial overall survival rates were 92% and 88%, respectively. Only 1 patient died from prostate cancer at 92 months after treatment, giving an 8-year actuarial cancer-specific survival of 98%. Radiation therapy was well tolerated, with 57% of patients not experiencing any acute gastrointestinal (GI) or genitourinary (GU) toxicity. For late toxicity, the worst grade ≥2 rate for GI and GU toxicity was 27% and 33%, respectively. There was no grade >3 toxicity. At last follow-up, the rate of grade ≥2 for both GI and GU toxicity was only 1.5%. Conclusions: Hypofractionation with 66 Gy in 22 fractions prescribed to the isocenter using 3-dimensional conformal radiation therapy produces excellent biochemical control rates, with moderate toxicity. However, this regimen cannot be extrapolated to the intensity modulated radiation therapy technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Population-Based Comparative Effectiveness Study of Radiation Therapy Techniques in Stage III Non-Small Cell Lung Cancer

Purpose: Concerns have been raised about the potential for worse treatment outcomes because of dosimetric inaccuracies related to tumor motion and increased toxicity caused by the spread of low-dose radiation to normal tissues in patients with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). We therefore performed a population-based comparative effectiveness analysis of IMRT, conventional 3-dimensional conformal radiation therapy (3D-CRT), and 2-dimensional radiation therapy (2D-RT) in stage III NSCLC. Methods and Materials: We used the Surveillance, Epidemiology, and End Results (SEER)-Medicare database to identify a cohort of patients diagnosed with stage III NSCLC from 2002 to 2009 treated with IMRT, 3D-CRT, or 2D-RT. Using Cox regression and propensity score matching, we compared survival and toxicities of these treatments. Results: The proportion of patients treated with IMRT increased from 2% in 2002 to 25% in 2009, and the use of 2D-RT decreased from 32% to 3%. In univariate analysis, IMRT was associated with improved overall survival (OS) (hazard ratio [HR] 0.90, P=.02) and cancer-specific survival (CSS) (HR 0.89, P=.02). After controlling for confounders, IMRT was associated with similar OS (HR 0.94, P=.23) and CSS (HR 0.94, P=.28) compared with 3D-CRT. Both techniques had superior OS compared with 2D-RT. IMRT was associated with similar toxicity risks on multivariate analysis compared with 3D-CRT. Propensity score matched model results were similar to those from adjusted models. Conclusions: In this population-based analysis, IMRT for stage III NSCLC was associated with similar OS and CSS and maintained similar toxicity risks compared with 3D-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UV resistance of polystyrene co-butyl acrylate (PSBA) encapsulated lignin–saponite nanohybrid composite film

Protecting biological systems and organic materials from high ultraviolet (UV) radiation is a significant issue for engineering materials in both terrestrial and space applications. In this study, the synthesized composites of polystyrene butyl acrylate (PSBA) encapsulated lignin based nanohybrid were evaluated as UV resistant cladding materials for both applications. The UV transmittance of the composite films and their physical, thermal, and chemical degradation after prolonged exposure to high UV radiation (10 Earth days and 30 Mars equivalent days) at low temperatures of 3.4 °C were examined. Here, the results showed that the composite films blocked the UV radiation and there was no significant effect of UV radiation on film integrity, mechanical and thermal properties of the composite films when they were exposed to high intensity UV radiation (132 W/m 2 ) within 24 h. Further, FTIR spectra of the composite films before and after UV radiation demonstrated that the films did not have notable oxidation degradation, although the glass transition temperature was slightly decreased with in- creased exposure time.

36 MATERIALS SCIENCE↗

Atmospheric general circulation and its low frequency variance - Radiative influences

The possible effects of radiation on the evolution of the atmosphere on time scales ranging from about a week to about 90 days are examined with reference to the available observational and modeling studies. The clear-sky and cloud radiative processes are shown to exert significant vertical, latitudinal, and longitudinal gradients in the diabatic heating within the troposphere and the stratosphere. The meridional heating gradient, which drives the general circulation, is altered significantly by clouds. The major conclusion of the study is that the observed negative anomalies in the outgoing IR radiation following intense warm episodes of tropicl sea-surface temperature (El Nino) are indeed anomalies in the cloud-radiative forcing.

Ramanathan, V.↗

Development of Advanced Thermal and Environmental Barrier Coatings Using a High-Heat-Flux Testing Approach

The development of low conductivity, robust thermal and environmental barrier coatings requires advanced testing techniques that can accurately and effectively evaluate coating thermal conductivity and cyclic resistance at very high surface temperatures (up to 1700 C) under large thermal gradients. In this study, a laser high-heat-flux test approach is established for evaluating advanced low conductivity, high temperature capability thermal and environmental barrier coatings under the NASA Ultra Efficient Engine Technology (UEET) program. The test approach emphasizes the real-time monitoring and assessment of the coating thermal conductivity, which initially rises under the steady-state high temperature thermal gradient test due to coating sintering, and later drops under the cyclic thermal gradient test due to coating cracking/delamination. The coating system is then evaluated based on damage accumulation and failure after the combined steady-state and cyclic thermal gradient tests. The lattice and radiation thermal conductivity of advanced ceramic coatings can also be evaluated using laser heat-flux techniques. The external radiation resistance of the coating is assessed based on the measured specimen temperature response under a laser- heated intense radiation-flux source. The coating internal radiation contribution is investigated based on the measured apparent coating conductivity increases with the coating surface test temperature under large thermal gradient test conditions. Since an increased radiation contribution is observed at these very high surface test temperatures, by varying the laser heat-flux and coating average test temperature, the complex relation between the lattice and radiation conductivity as a function of surface and interface test temperature may be derived.

Zhu, Dongming↗