A targeted proteomics toolkit for high-throughput absolute quantification of Escherichia coli proteins
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Revealing the structure of supported metal oxide catalysts is a prerequisite for establishing the structure - catalysis relationship. Among a variety of characterization techniques, multi-wavelength Raman spectroscopy, combining resonance Raman and non-resonance Raman with different excitation wavelengths, has recently emerged as a particularly powerful tool in not only identifying but also quantifying the structure of supported metal oxide clusters. In our review, we make use of two supported vanadia systems, VO x /SiO 2 and VO x /CeO 2 , as examples to showcase how one can employ this technique to investigate the heterogeneous structure of active oxide clusters and to understand the complex interaction between the oxide clusters and the support. Moreover, the qualitative and quantitative structural information gained from the multi-wavelength Raman spectroscopy can be utilized to provide fundamental insights for designing more efficient supported metal oxide catalysts.
Explore the source record for details and available documents.
A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.
Dense LC-MS datasets have convoluted extracted ion chromatograms with multiple chromatographic peaks that cloud the differentiation between intact compounds with their overlapping isotopic distributions, peaks due to insource ion fragmentation, and noise. Making this differentiation is critical in glycomics datasets because chromatographic peaks correspond to different intact glycan structural isomers. The GlyQ-IQ software is targeted chromatography centric software designed for chromatogram and mass spectra data processing and subsequent glycan composition annotation. The targeted analysis approach offers several key advantages to LC-MS data processing and annotation over traditional algorithms. A priori information about the individual target’s elemental composition allows for exact isotope profile modeling for improved feature detection and increased sensitivity by focusing chromatogram generation and peak fitting on the isotopic species in the distribution having the highest intensity and data quality. Glycan target annotation is corroborated by glycan family relationships and in source fragmentation detection. The GlyQ-IQ software is developed in this work (Part 1) and was used to profile N-glycan compositions from human serum LC-MS Datasets. The companion manuscript GlyQ-IQ Part 2 discusses developments in human serum N-glycan sample preparation, glycan isomer separation, and glycan electrospray ionization. A case study is presented to demonstrate how GlyQ-IQ identifies and removes confounding chromatographic peaks from high mannose glycan isomers from human blood serum. In addition, GlyQ-IQ was used to generate a broad N-glycan profile from a high resolution (100K/60K) nESI-LS-MS/MS dataset including CID and HCD fragmentation acquired on a Velos Pro Mass spectrometer. 101 glycan compositions and 353 isomer peaks were detected from a single sample. 99% of the GlyQ-IQ glycan-feature assignments passed manual validation and are backed with high resolution mass spectra and mass accuracies less than 7 ppm.
Explore the source record for details and available documents.
To meet the ever-increasing need for high-throughput screening in metabolic engineering, information-rich, fast screening methods are needed. Mass spectrometry (MS) provides an efficient and general approach for metabolite screening and offers the capability of characterizing a broad range of analytes in a label-free manner, but often requires a range of sample clean-up and extraction steps. Liquid extraction surface analysis (LESA) coupled MS is an image-guided MS surface analysis approach that directly samples and introduces metabolites from a surface to MS. Here, we combined the advantages of LESA–MS and an acoustic liquid handler with stable isotope-labeled internal standards. This approach provides absolute quantitation of target chemicals from liquid culture-dried droplets and enables high-throughput quantitative screening for microbial metabolites. In this paper, LESA–MS was successfully applied to quantify several different metabolites (itaconic acid, triacetic acid lactone, and palmitic acid) from different yeast strains in different mediums, demonstrating its versatility, accuracy, and efficiency across a range of microbial engineering applications.
A new sheathless CITP/CZE-MS interface, based on a commercially available capillary with an integrated metal coated ESI emitter, was developed in this study aiming at overcoming the reproducibility and ruggedness problems, suffered to a certain degree by almost all the available CE-MS interfaces, and pushing the CE-MS technology suitable for routine sample analysis with high sensitivity. The new CITP/CZE-MS interface allows the electric contact between ESI voltage power supply and the CE separation liquid by using a conductive liquid that comes in contact with the metal coated surface of the ESI emitter, making it a true sheathless CE-MS interface. Stable electrospray was established by avoiding the formation of gas bubbles from electro chemical reaction at the emitter tip or inside of the CE capillary. Crucial operating parameters, such as sample loading volume, flow rate, and separation voltage, were systematically evaluated for their effects on both CITP/CZE separation efficiency and MS detection sensitivity. Around one hundred CITP/CZE-MS analyses can be easily achieved by using the new sheathless CITP/CZE interface without a noticeable loss of metal coating on the ESI emitter surface, or degrading of the ESI emitter performance. The reproducibility in analyte migration time and quantitative performance of the new interface was experimentally evaluated to demonstrate a LOQ bellow 5 attomole.
Accurately measuring circulating proinsulin proteoforms is crucial for clinical investigation of diabetes, but was previously not feasible owing to limited assay specificity/sensitivity. Here, in this study, we devised a highly sensitive LC-MS-based strategy to quantify intact proinsulin, des-31,32 and des-64,65 proinsulin, and C-peptide in circulation. The method involves: (i) quantitative, robust affinity capture using an optimized antibody cocktail, eliminating the severe quantitative bias across multiple proteoforms typically introduced when using a single antibody; (ii) Lys-C digestion producing unique signature peptides for each proteoform, and (iii) trapping-nano-LC coupled with FAIMS/dCV-MS for an ultrasensitive analysis. The selective trapping/delivery ensured sensitive/selective analysis of the targets while achieving excellent analytical robustness that is critical for clinical assays, and the FAIMS/dCV substantially reduces baseline noise/interferences, further enhancing S/N. The assay achieved exceptional sensitivity, with serum LOQs of 1.7, 2.3, and 3.6 pg/mL respectively for intact-proinsulin, des-31,32 and des-64,65, representing the first assay capable of sensitively quantifying these major circulating proinsulin proteoforms. We applied this assay to 78 subjects, including autoantibody positive (n = 20) and new-onset type 1 diabetes (T1D, n = 19) with respective age/sex/BMI-matched controls, enabling the first accurate profiling of proinsulin proteoforms in clinical groups. The assay results demonstrated a clear separation of control and new-onset T1D groups that a parallel total-proinsulin ELISA assay fails to capture. Furthermore, distinct expression patterns in relative abundance ratios among proteoforms were observed across clinical groups. This assay may provide valuable insights into the β-cell functions and the onset/progression of diabetes and other associated conditions. Moreover, the strategy is broadly applicable to targeted measurement of other biomarker proteoforms.
In this article, we demonstrate that atom probe tomography (APT) can be applied to small-molecule organic materials. We show that APT can provide an unprecedented combination of mass resolution of <1 Da, spatial resolution of ~0.3 nm in z and ~1 nm in x–y, and analytic sensitivity of ~50 ppm with no evidence of molecular fragmentation. We discuss two systems that demonstrate the power of APT to uncover structure–property relationships in organic systems that have proven extremely difficult to probe using existing techniques: (1) a previously published model organic photovoltaic system in which we show a chemical reaction occurs at the heterointerface; and (2) a model organic light-emitting diode system in which we show molecular segregation occurs in the emissive layer bulk. Lastly, these examples illustrate the power of APT to enable new insights into organic molecular materials.
Understanding flow, transport, chemical reactions, and hydromechanical processes in fractured geologic materials is key for optimizing a range of subsurface processes including carbon dioxide and hydrogen storage, unconventional energy resource extraction, and geothermal energy recovery. Flow and transport processes in naturally fractured shale rocks have been challenging to characterize due to experimental complexity and the multiscale nature of quantifying continuum scale descriptions of mass exchange between micrometer-scale fractures and nanometer-scale pores. In this study, we use positron emission tomography (PET) to image the transport of a conservative tracer in a naturally fractured Wolfcamp shale core before and after the core was exposed to low pH brine conditions. Image-based experimental observations are interpreted by fitting an analytical transport model to fracture-containing voxels in the core. Results of this analysis indicate subtle increases in matrix diffusivity and a slightly more uniform fracture velocity distribution following exposure to low pH conditions. These observations are compared with a multicomponent one-dimensional reactive transport model that indicates the capacity for a 10% increase in porosity at the fracture-matrix interface as a result of the low pH brine exposure. This porosity change is the result of the dissolution of carbonate minerals in the shale matrix to low pH conditions. Further, this image-based workflow represents a new approach for quantifying spatially resolved fracture-matrix transport processes and provides a foundation for future work to better understand the role of coupled transport, reaction, and mechanical processes in naturally fractured rocks.
In 2013, the Pacific Northwest National Laboratory led a geologic carbon sequestration field demonstration where ~1000 tonnes of CO 2 was injected into several deep Columbia River Basalt zones near Wallula, Washington. Rock core samples extracted from the injection zone two years after CO 2 injection revealed nascent carbonate mineralization that was qualitatively consistent with expectations from laboratory experiments and reactive transport modeling. In this study, we report on a new detailed analysis of the 2012 pre-injection and 2015 post-injection hydrologic tests that capitalizes on the difference in fluid properties between scCO 2 and water to assess changes in near-field, wellbore, and reservoir conditions that are apparent approximately two years following the end of injection. This comparative hydrologic test analysis method provides a new way to quantify the amount of injected CO 2 that was mineralized in the field test. Modeling results indicate that approximately 60% of the injected CO 2 was sequestered via mineralization within two years, with the resulting carbonates occupying ~4% of the available reservoir pore space. The method presented here provides a new monitoring tool to assess the fate of CO 2 injected into chemically reactive basalt formations but could also be adapted for long-term monitoring and verification within more traditional subsurface carbon storage reservoirs.
Saharan dust is an important phosphorus (P) supply to remote and oligotrophic parts of the oceans and American lowland tropical rainforests. Phosphorus speciation in aeolian dust ultimately controls the release and bioavailability of P after dust deposition, but the speciation in Saharan dust and its change during the trans-Atlantic transport remains unclear. Here, using P K-edge X-ray absorption near edge structure (XANES) spectroscopy, we showed that with increasing dust traveling distance from the Sahara Desert to Cape Verde and to Puerto Rico, about 570 and 4000 km, respectively, the proportion of Ca-bound P (Ca-P), including both apatite and non-apatite forms, decreased from 68–73% to 50–71% and to 21–37%. The changes were accompanied by increased iron/aluminum-bound P proportion from 14–25% to 23–46% and to 44–73%, correspondingly. Laboratory simulation experiments suggest that the changes in P speciation can be ascribed to increasing degrees of particle sorting and atmospheric acidification during dust transport. The presence of relatively soluble non-apatite Ca-P in the Cape Verde dust but not in the Puerto Rico dust is consistent with the higher P water solubility of the former than the latter. Our findings provide insights into the controls of atmospheric processes on P speciation, solubility, and stability in Saharan dust.
The Hanford site represents a complicated environmental remediation challenge, remaining from the production of nuclear weapons. Over 100 million gallons of liquid radioactive waste of unknown composition will be chemically processed and vitrified, but the varying chemical composition and highly radioactive nature of the waste preclude the implementation of more developed, offline technologies to determine the composition. The only practical approach to waste treatment will require the significant utilization of real-time, chemometric modeling approaches. Although chemometric approaches have been applied to the analysis of Hanford waste, the models developed were highly tank-specialized, and limited discussion was provided on how models fared with interfering signals. As the tank waste is largely composed of oxoanions, which tend to have interfering Raman spectra, the general question was posed as to what chemometric approach is best suited to accurately quantify analytes in the presence of interfering signals. This was carried out by examining the ability of classical least square (CLS), principal component regression (PCR), partial least square (PLS), and locally weighted regression (LWR) to quantify NO 3 – and CO 3 2– using their bands around 1050 cm –1 . Finally, for all samples, the PLS-based model was found to be the most efficient approach from a model building and application perspective.
Explore the source record for details and available documents.