Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Creep anisotropy modeling and uncertainty quantification of an additively manufactured Ni-based superalloy

The advantages offered by additive manufacturing over traditional processes has driven a great deal of industrial and academic interest in recent years. However, the process is relatively new and requires additional investigation to become sufficiently mature for wide scale industrial adoption. Electron beam melting powder bed fusion is one technology that has shown promise for fabricating high temperature resistant materials such as nickel based superalloys. The resulting microstructures typically exhibit a strong fiber texture in the build direction giving rise to anisotropic time-dependent deformation behavior. In order to accelerate the qualification of these materials for industrial adoption accurate numerical models are needed for simulating their behavior. In this work a crystal plasticity model including non-Schmid effects is presented for capturing creep anisotropy observed in additively manufactured IN738LC. The model is calibrated via a probabilistic framework where model parameters are treated as random variables. An iterative sequential design strategy is utilized to efficiently identify the probability density of the unknown model parameters. As a case study the model is utilized to investigate the behavior of randomly oriented equiaxed grain clusters sometimes observed embedded in the additively manufactured columnar structure. A synthetic realization is simulated and uncertainty is propagated through to the full-field response. Results indicate that these features are the source of significant creep relaxation and strain accumulation which partially explains observed grain boundary decohesion at these locations.

36 MATERIALS SCIENCE↗

In situ quantification of fracture slip induced by hydraulic injections in a deep borehole: A comparison of two different borehole techniques

In situ measurements of fracture deformation during fluid injection are rare, yet essential for understanding the mechanical response of fractured rock. In this study, we evaluate the reliability of two methods by comparing their slip vector estimates: high-resolution borehole acoustic televiewer images captured before and after injection tests, and displacement data from a three-component borehole deformation probe recorded during the injections. Acoustic televiewer images capture only final in-plane displacement, whereas three-component borehole deformation measurements provide full 3D, transient fracture movement. Four injection tests in a fractured granitic rock mass along an inclined borehole at the Bedretto Underground Laboratory (Switzerland), beneath more than 1100 m of overburden, were analyzed. The two methods yielded consistent kinematics and comparable slip magnitudes, typically in the range of 0.2 – 0.6 mm. Angular differences between estimated slip directions ranged from 0.2° to 28°. For two test intervals with pre-existing fractures optimally oriented for slip, the measured slip vectors agreed with forward-modeled slip vectors based on the regional in situ stress field, supporting the Wallace–Bott hypothesis. Measurable shear displacement was identified in two test intervals containing fractures oriented nearly perpendicular to the least principal stress, including a newly formed hydraulic fracture. This demonstrates that even fractures unfavorably oriented for slip can undergo shear due to local stress perturbations around an inclined borehole.

Acoustic televiewer↗

Quantification of Motion of Different Thoracic Locations Using Four-Dimensional Computed Tomography: Implications for Radiotherapy Planning

Purpose: To assess the respiratory motion of different thoracic nodal locations and its dependence on the presence of enlarged nodes; to assess the respiratory motion of different parenchymal tumor locations; and to determine the appropriate margins to cover the respiratory motion of targets at these locations. Methods and Materials: We reviewed the four-dimensional computed tomography scans of 20 patients with thoracic tumors treated at our institution. The motion of four central thoracic locations (aortic arch, carina, and bilateral hila), parenchymal tumor locations (upper vs. lower, and anterior vs. middle vs. posterior thorax), and bilateral diaphragmatic domes was measured. Results: For the central thoracic locations, the largest motion was in the superoinferior (SI) dimension (>5 mm for bilateral hila and carina, but <4 mm for aortic arch). No significant difference was found in the motion of these locations in the absence or presence of enlarged nodes. For parenchymal tumors, upper tumors exhibited smaller SI motion than did lower tumors (3.7 vs. 10.4 mm, p = 0.029). Similarly, anterior tumors exhibited smaller motion than did posterior tumors in both the SI (4.0 vs. 8.0 mm, p = 0.013) and lateral (2.8 vs. 4.6 mm, p = 0.045) directions. The margins that would be needed to encompass the respiratory motion of each of the evaluated locations in 95% of patients were tabulated and range from 3.4 to 37.2 mm, depending on the location and direction. Conclusions: The results of our study have provided data for appropriate site-specific internal target volume expansion that could be useful in the absence of four-dimensional computed tomography-based treatment planning. However, generalizing the results from a small patient population requires discretion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Mediastinal and Hilar Lymph Node Movement Using Four-Dimensional Computed Tomography Scan: Implications for Radiation Treatment Planning

Purpose: To quantitatively describe mediastinal and hilar lymph node movement in patients with lymph node-positive lung cancer. Methods and Materials: Twenty-four patients with lung cancer who underwent four-dimensional computed tomography scanning at Massachusetts General Hospital were included in the study. The maximum extent of superior motion of the superior border was measured, as well as the maximum inferior movement of the inferior border. The average of these two values is defined as the peak-to-peak movement. This process was repeated for mediolateral (ML) and anterior-posterior (AP) movement. Linear regression was used to determine lymph node characteristics associated with peak-to-peak movement. Various uniform expansions were investigated to determine the expansion margins necessary to ensure complete internal target volume (ITV) coverage. Results: The mean peak-to-peak displacements of paratracheal lymph nodes were 4 mm (craniocaudal [CC]), 2 mm (ML), and 2 mm (AP). For subcarinal lymph nodes, the mean peak-to-peak movements were 6 mm (CC), 4 mm (ML), and 2 mm (AP). The mean peak-to-peak displacements of hilar lymph nodes were 7 mm (CC), 1 mm (ML), and 4 mm (AP). On multivariate analysis, lymph node station and lymph node size were significantly related to peak-to-peak movement. Expansions of 8 mm for paratracheal nodes and 13 mm for subcarinal and hilar nodes would have been necessary to cover the ITV of 95% of these nodal masses. Conclusions: Subcarinal and hilar lymph nodes may move substantially throughout the respiratory cycle. In the absence of patient-specific information on nodal motion, expansions of at least 8 mm, 13 mm, and 13 mm should be considered to cover the ITV of paratracheal, subcarinal, and hilar lymph nodes, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Prostate and Seminal Vesicle Interfraction Variation During IMRT

Purpose: To quantify the interfraction variability in prostate and seminal vesicle (SV) positions during a course of intensity-modulated radiotherapy (IMRT) using an integrated computed tomography (CT)-linear accelerator system and to assess the impact of rectal and bladder volume changes. Methods and Materials: We studied 15 patients who had undergone IMRT for prostate carcinoma. Patients had one pretreatment planning CT scan followed by three in-room CT scans per week using a CT-on-rails system. The prostate, bladder, rectum, and pelvic bony anatomy were contoured in 369 CT scans. Using the planning CT scan as a reference, the volumetric and positional changes were analyzed in the subsequent CT scans. Results: For all 15 patients, the mean systematic internal prostate and SV variation was 0.1 {+-} 4.1 mm and 1.2 {+-} 7.3 mm in the anteroposterior axis, -0.5 {+-} 2.9 mm and -0.7 {+-} 4.5 mm in the superoinferior axis, and 0.2 {+-} 0.9 mm and -0.9 {+-} 1.9 mm in the lateral axis, respectively. The mean magnitude of the three-dimensional displacement vector was 4.6 {+-} 3.5 mm for the prostate and 7.6 {+-} 4.7 mm for the SVs. The rectal and bladder volume changes during treatment correlated with the anterior and superior displacement of the prostate and SVs. Conclusion: The dominant prostate and SV variations occurred in the anteroposterior and superoinferior directions. The systematic prostate and SV variation between the treatment planning CT and daily therapy as a result of the rectal and bladder volume changes emphasizes the need for daily directed target localization and/or immobilization techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification and Visualization of Charged Particle Range Variations

Purpose: Range variations during respiration affect the penetration of charged particle beams and can result in beam overshoot or undershoot to the target. We have developed analysis tools to quantify the water equivalent pathlength (WEL) variations resulting from respiration (WEL analyzer, Aqualyzer), as well as a data explorer to view WEL variations interactively. Methods and Materials: The metrics to characterize and quantify penetration of a charged particle beam during respiration were calculated semiautomatically. The analysis involved the generation of images that (1) encode the radiologic pathlength across a beam's eye view image during the respiratory phase, (2) display the variation of the radiologic pathlength relative to a reference respiratory phase, (3) display isopenetration as a function of breathing, and (4) show range fluctuation images for a compensating bolus when applied to four-dimensional computed tomography. Additional quantities relevant to the analysis of charged particle beams in a breathing patient that are calculated include the beam overshoot volume and beam overshoot distance. These quantities are calculated as a function of time, gantry angle, and position. Results: The software was applied to test cases to illustrate its utility in the analysis of range variations of charged particle beams in the treatment of lung tumors. Conclusion: WEL analysis is useful in the rapid assessment of range variations in the treatment of lung tumors and in determining the optimal gantry angle and respiratory gating window. The extension of encoding range fluctuations to a beam's eye view display is helpful in designing plans that are more robust in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Tumor Volume Changes During Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: Dose escalation for lung cancer is limited by normal tissue toxicity. We evaluated sequential computed tomography (CT) scans to assess the possibility of adaptively reducing treatment volumes by quantifying the tumor volume reduction occurring during a course of radiotherapy (RT). Methods and Materials: A total of 22 patients underwent RT for Stage I-III non-small-cell lung cancer with conventional fractionation; 15 received concurrent chemotherapy. Two repeat CT scans were performed at a nominal dose of 30 Gy and 50 Gy. Respiration-correlated four-dimensional CT scans were used for evaluation of respiratory effects in 17 patients. The gross tumor volume (GTV) was delineated on simulation and all individual phases of the repeat CT scans. Parenchymal tumor was evaluated unless the nodal volume was larger or was the primary. Subsequent image sets were spatially co-registered with the simulation data for evaluation. Results: The median GTV reduction was 24.7% (range, -0.3% to 61.7%; p < 0.001, two-tailed t test) at the first repeat scan and 44.3% (range, 0.2-81.6%, p < 0.001) at the second repeat scan. The volume reduction was not significantly different between patients receiving chemoradiotherapy vs. RT alone, a GTV >100 cm{sup 3} vs. <100 cm{sup 3}, and hilar and/or mediastinal involvement vs. purely parenchymal or pleural lesions. A tendency toward a greater volume reduction with increasing dose was seen, although this did not reach statistical significance. Conclusion: The results of this study have demonstrated significant alterations in the GTV seen on repeat CT scans during RT. These observations raise the possibility of using an adaptive approach toward RT of non-small-cell lung cancer to minimize the dose to normal structures and more safely increase the dose directed at the target tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Local Tumor Response to Fractionated Radiation Therapy for Non-Hodgkin Lymphoma Using Weekly {sup 18}F-FDG PET/CT Imaging

Purpose: To quantify, in a feasibility study, metabolic and volumetric response to fractionated radiation therapy (RT) using weekly {sup 18}F fluoro-deoxyglucose positron emission tomography (PET) imaging for 10 non-Hodgkin lymphoma (NHL) patients, and to correlate them to clinical outcome. Methods and Materials: Ten patients with chemotherapy-refractory NHL planned for radical RT were prospectively entered into a research study. PET/computed tomography (CT) scans were acquired before RT, and repeated weekly during the 3- to 4-week course of RT, and at 1 and 3 months after therapy. Gross tumor volumes were contoured on CT scans and the corresponding maximum standardized uptake values (SUV{sub max}) determined in the coregistered PET images. The clinical outcomes of interest were local tumor response at 3 months post-RT and local tumor status at last follow-up or time of death. Results: {sup 18}F fluoro-deoxyglucose uptake from inflammation was rarely observed. The responses showed a large variability between patients. SUV{sub max} decreased consistently with a median of -2.1% per Gy (range, -3.3 to -0.7) and the median of the volumetric response was -2.2% per Gy (range, -2.8 to +0.5). Initial SUV{sub max} was not correlated with local control, whereas smaller initial tumor volume was, with smaller tumors more likely to achieve local control. The responses after treatment were also correlated to local control, but not the responses during treatment. Conclusions: Radiation does not confound the FDG uptake in the NHL tumor and normal tissues. Only smaller initial tumor volume and metabolic and volumetric response after completion of radiation therapy significantly correlated with eventual local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Artifact Reduction With Real-Time Cine Four-Dimensional Computed Tomography Acquisition Methods

Purpose: To quantify the magnitude and frequency of artifacts in simulated four-dimensional computed tomography (4D CT) images using three real-time acquisition methods- direction-dependent displacement acquisition, simultaneous displacement and phase acquisition, and simultaneous displacement and velocity acquisition- and to compare these methods with commonly used retrospective phase sorting. Methods and Materials: Image acquisition for the four 4D CT methods was simulated with different displacement and velocity tolerances for spheres with radii of 0.5 cm, 1.5 cm, and 2.5 cm, using 58 patient-measured tumors and respiratory motion traces. The magnitude and frequency of artifacts, CT doses, and acquisition times were computed for each method. Results: The mean artifact magnitude was 50% smaller for the three real-time methods than for retrospective phase sorting. The dose was {approx}50% lower, but the acquisition time was 20% to 100% longer for the real-time methods than for retrospective phase sorting. Conclusions: Real-time acquisition methods can reduce the frequency and magnitude of artifacts in 4D CT images, as well as the imaging dose, but they increase the image acquisition time. The results suggest that direction-dependent displacement acquisition is the preferred real-time 4D CT acquisition method, because on average, the lowest dose is delivered to the patient and the acquisition time is the shortest for the resulting number and magnitude of artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of the Relative Biological Effectiveness for Ion Beam Radiotherapy: Direct Experimental Comparison of Proton and Carbon Ion Beams and a Novel Approach for Treatment Planning

Purpose: To present the first direct experimental in vitro comparison of the biological effectiveness of range-equivalent protons and carbon ion beams for Chinese hamster ovary cells exposed in a three-dimensional phantom using a pencil beam scanning technique and to compare the experimental data with a novel biophysical model. Methods and Materials: Cell survival was measured in the phantom after irradiation with two opposing fields, thus mimicking the typical patient treatment scenario. The novel biophysical model represents a substantial extension of the local effect model, previously used for treatment planning in carbon ion therapy for more than 400 patients, and potentially can be used to predict effectiveness of all ion species relevant for radiotherapy. A key feature of the new approach is the more sophisticated consideration of spatially correlated damage induced by ion irradiation. Results: The experimental data obtained for Chinese hamster ovary cells clearly demonstrate that higher cell killing is achieved in the target region with carbon ions as compared with protons when the effects in the entrance channel are comparable. The model predictions demonstrate agreement with these experimental data and with data obtained with helium ions under similar conditions. Good agreement is also achieved with relative biological effectiveness values reported in the literature for other cell lines for monoenergetic proton, helium, and carbon ions. Conclusion: Both the experimental data and the new modeling approach are supportive of the advantages of carbon ions as compared with protons for treatment-like field configurations. Because the model predicts the effectiveness for several ion species with similar accuracy, it represents a powerful tool for further optimization and utilization of the potential of ion beams in tumor therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3'-deoxy-3'-[{sup 18}F]fluorothymidine PET Quantification of Bone Marrow Response to Radiation Dose

Purpose: The purpose of this study was to quantify the relationship of bone marrow response to radiation dose, using 3'-deoxy-3'-[{sup 18}F]fluorothymidine ([{sup 18}F]FLT)-labeled uptake quantified in positron-emission tomography (PET) scans. Methods and Materials: Pre- and post-Week 1 treatment [{sup 18}F]FLT PET images were registered to the CT images used to create the radiation treatment plan. Changes in [{sup 18}F]FLT uptake values were measured using profile data of standardized uptake values (SUVs) and doses along the vertebral bodies located at a field border where a range of radiation doses were present for 10 patients. Data from the profile measurements were grouped into 1 Gy dose bins from 1 to 9 Gy to compare SUV changes for all patients. Additionally, the maximum pretreatment, the post-Week 1 treatment, and the dose values located within the C6-T7 vertebrae that straddled the field edge were measured for all patients. Results: Both the profile and the individual vertebral data showed a strong correlation between SUV change and radiation dose. Relative differences in SUVs between bins >1 Gy and <7 Gy were statistically significant (p < 0.01, two-sample t test). The reduction in SUV was approximately linear until it reached a reduction threshold of 75%-80% in SUV for doses greater than 6 Gy/week for both the dose-binned data and the vertebral maximum SUVs. Conclusions: The change in SUV observed in head and neck cancer patients treated with chemoradiation shows the potential for using [{sup 18}F]FLT PET images for identifying active bone marrow and monitoring changes due to radiation dose. Additionally, the change in [{sup 18}F]FLT uptake observed in bone marrow for different weekly doses suggests potential dose thresholds for reducing bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin Construction

Purpose: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Methods and Materials: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. Results: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin{sup 4} function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. Conclusion: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Contralateral Breast Dose and Risk Estimate of Radiation-Induced Contralateral Breast Cancer Among Young Women Using Tangential Fields and Different Modes of Breathing

Purpose: Whole breast irradiation with deep-inspiration breath-hold (DIBH) technique among left-sided breast cancer patients significantly reduces cardiac irradiation; however, a potential disadvantage is increased incidental irradiation of the contralateral breast. Methods and Materials: Contralateral breast dose (CBD) was calculated by comparing 400 treatment plans of 200 left-sided breast cancer patients whose tangential fields had been planned on gated and nongated CT data sets. Various anatomic and field parameters were analyzed for their impact on CBD. For a subgroup of patients (aged {<=}45 years) second cancer risk in the contralateral breast (CB) was modeled by applying the linear quadratic model, compound models, and compound models considering dose-volume information (DVH). Results: The mean CBD was significantly higher in DIBH with 0.69 Gy compared with 0.65 Gy in normal breathing (P=.01). The greatest impact on CBD was due to a shift of the inner field margin toward the CB in DIBH (mean 0.4 cm; range, 0-2), followed by field size in magnitude. Calculation with different risk models for CBC revealed values of excess relative risk/Gy ranging from 0.48-0.65 vs 0.46-0.61 for DIBH vs normal breathing, respectively. Conclusion: Contralateral breast dose, although within a low dose range, was mildly but significantly increased in 200 treatment plans generated under gated conditions, predominately due to a shift in the medial field margin. Risk modeling for CBC among women aged {<=}45 years also pointed to a higher risk when comparing DIBH with normal breathing. This risk, however, was substantially lower in the model considering DVH information. We think that clinical decisions should not be affected by this small increase in CBD with DIBH because DIBH is effective in reducing the dose to the heart in all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification and Minimization of Uncertainties of Internal Target Volume for Stereotactic Body Radiation Therapy of Lung Cancer

Purpose: To quantify uncertainties in delineating an internal target volume (ITV) and to understand how these uncertainties may be individually minimized for stereotactic body radiation therapy (SBRT) of early stage non-small cell lung cancer (NSCLC). Methods and Materials: Twenty patients with NSCLC who were undergoing SBRT were imaged with free-breathing 3-dimensional computed tomography (3DCT) and 10-phase 4-dimensional CT (4DCT) for delineating gross tumor volume (GTV){sub 3D} and ITV{sub 10Phase} (ITV3). The maximum intensity projection (MIP) CT was also calculated from 10-phase 4DCT for contouring ITV{sub MIP} (ITV1). Then, ITV{sub COMB} (ITV2), ITV{sub 10Phase+GTV3D} (ITV4), and ITV{sub 10Phase+ITVCOMB} (ITV5) were generated by combining ITV{sub MIP} and GTV{sub 3D}, ITV{sub 10phase} and GTV{sub 3D}, and ITV{sub 10phase} and ITV{sub COMB}, respectively. All 6 volumes (GTV{sub 3D} and ITV1 to ITV5) were delineated in the same lung window by the same radiation oncologist. The percentage of volume difference (PVD) between any 2 different volumes was determined and was correlated to effective tumor diameter (ETD), tumor motion ranges, R{sub 3D}, and the amplitude variability of the recorded breathing signal (v) to assess their volume variations. Results: The mean (range) tumor motion (R{sub SI}, R{sub AP}, R{sub ML}, and R{sub 3D}) and breathing variability (v) were 7.6 mm (2-18 mm), 4.0 mm (2-8 mm), 3.3 mm (0-7.5 mm), 9.9 mm (4.1-18.7 mm), and 0.17 (0.07-0.37), respectively. The trend of volume variation was GTV{sub 3D} =}0.503, P{<=}.047). The PVDs for pairs of ITV2 vs ITV5 and ITV5 vs ITV4 negatively correlated with ETD (r=0.502, -0.626; P=.047, .010). No other correlation was found. Conclusion: Uncertainties in individualized ITVs for SBRT of early stage NSCLC could effectively be minimized by combining information from 3DCT, 4DCT, and MIP. If these images cannot be efficiently contoured, a combination of ITV{sub MIP} and GTV{sub 3D} could be an effective alternative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Proton Dose Calculation Accuracy in the Lung

Purpose: To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)–based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung. Methods and Materials: A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung, and to determine the distal fall-off of the proton beam. Results were compared with TPS and MC calculations. Dose distributions in 19 patients (54 fields total) were simulated using MC and compared to the TPS algorithm. Results: MC increased dose calculation accuracy in lung tissue compared with the TPS and reproduced dose measurements in the target to within ±2%. The average difference between measured and predicted dose in a plane through the center of the target was 5.6% for the TPS and 1.6% for MC. MC recalculations in patients showed a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. For large tumors, MC also predicted consistently higher V5 and V10 to the normal lung, because of a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target could show large deviations, although this effect was highly patient specific. Range measurements showed that MC can reduce range uncertainty by a factor of ∼2: the average (maximum) difference to the measured range was 3.9 mm (7.5 mm) for MC and 7 mm (17 mm) for the TPS in lung tissue. Conclusion: Integration of Monte Carlo dose calculation techniques into the clinic would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. In addition, the ability to confidently reduce range margins would benefit all patients by potentially lowering toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗