Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Feasibility study of ferromagnetic/ferroelectric films for enhanced microwave devices

This report summarizes exploratory work conducted to assess the feasibility of ferromagnetic/ferroelectric films for next-generation microwave devices. From literature review, it is established that while an increasing number of ferroelectric/ferromagnetic composites are being investigated, a number have transition temperatures that are too low and structures that are not robust enough for low cost, room temperature antenna arrays. On the other hand, several promising systems are identified, including the multiferroic BiFeO3 and a composite system of Ba/SrTiO3 and a related perovskite manganite. It is suggested that when the NASA pulsed laser deposition chamber is fully operational, thin films of these systems be investigated. In preparation for such work, we have reconfirmed several structural features of an existing Ba/SrTiO3 film using the x-ray diffractometer at Oberlin College.

Ijiri, Yumi↗

Aerothermodynamic Design of the Mars Science Laboratory Heatshield

Aerothermodynamic design environments are presented for the Mars Science Laboratory entry capsule heatshield. The design conditions are based on Navier-Stokes flowfield simulations on shallow (maximum total heat load) and steep (maximum heat flux, shear stress, and pressure) entry trajectories from a 2009 launch. Boundary layer transition is expected prior to peak heat flux, a first for Mars entry, and the heatshield environments were defined for a fully-turbulent heat pulse. The effects of distributed surface roughness on turbulent heat flux and shear stress peaks are included using empirical correlations. Additional biases and uncertainties are based on computational model comparisons with experimental data and sensitivity studies. The peak design conditions are 197 W/sq cm for heat flux, 471 Pa for shear stress, 0.371 Earth atm for pressure, and 5477 J/sq cm for total heat load. Time-varying conditions at fixed heatshield locations were generated for thermal protection system analysis and flight instrumentation development. Finally, the aerothermodynamic effects of delaying launch until 2011 are previewed.

Edquist, Karl T.↗

Studies in electron phenomena in MOS structures: The pulsed C-V method

The pulse hysteresis capacitance voltage (C-V) provides a straight forward technique for measuring the change of various charges in MOS structures and a tool for investigating the kinetics of various electron phenomena is developed and described. The method can be used for measuring the energy distribution and kinetics of surface states with the resolution of about 1/5 x 10 to the -9 power cm eV. Some transients in an MOS structure, particularly, the thermal generation of minority charge carriers via surface states and the relaxation of minority charge carriers supplied from the inversion layer outside the MOS structure are theoretically investigated. Analytical expressions which clearly present the physics of those electron phenomena are derived.

Kaplan, G.↗

Solitary waves in mantle plumes

Numerical calculations in two dimensions show that solitary wave disturbances can propagate along thermal plumes in a homogeneous, viscous fluid with a thermally activated rheology similar to the mantle. Comparison of the numerical results with analytic results from an idealized two-fluid model indicates that the two-fluid model can be applied to solitary waves in the thermally activated plume. A two-fluid model of solitary waves on cylindrical conduits is accordingly applied to mantle plumes to estimate the propagation speeds, time durations, and pulse lengths of solitary waves in mantle plumes as a function of background mantle viscosity, plume flux, plume density deficit, plume viscosity, and the volume of material transported by the solitary wave. It is inferred that mantle plumes may be eposodic via solitary waves and that these disturbances might account for observed 0(10 m.y.) variations in the durations and spacings of episodes of enhanced hotspot volcanic activity. Solitary waves in mantle plumes could be generated by interactions among plumes and between plumes and the large-scale, time-dependent mantle circulation.

Schubert, G.↗

Development of a two photon/laser induced fluorescence technique for the detection of atmospheric OH radicals

The development of a new mid-IR laser source was the primary goal. Backward propagating stimulated D2 Raman frequency down conversion of a commercially available 1.06 micron Nd:YAG laser was shown to generate an efficient source of 1.56 micron radiation with near diffraction limited beam quality. The efficient generation of a 2.9 micron laser source was also achieved using backward propagating CH4 Raman frequency down conversion of the 1.56 micron pump. Slightly higher efficiencies were obtained for frequency down conversion of the 1.06 micron Nd:YAG using the H2 Raman shift yielding a near diffraction limited source in the 200 mJ range at 1.9 micron. Similar conversion efficiencies are anticipated as a result of extending the wavelength coverage of recently available Ti:sapphire pulse laser to not only cover the 740 to 860 nm fundamental wavelength range but also the .95 to 1.15 and 1.06 to 1.33 micron range using D2 and H2, respectively. The anticipated sensitivity of a TP-LIF OH sensor using this mid-IR source would give signal limited detection of 1.4 x 10(exp 5) OH/cu cm under boundary layer conditions and 5.5 x 10(exp 4) OH/cu cm under free troposphere sampling conditions for a five minute signal integration period. This level of performance coupled with the techniques non-perturbing nature and freedom from both interferences and background would allow reliable tropospheric OH measurement to be obtained under virtually any ambient condition of current interest, including interstitial and sampling.

Bradshaw, John↗

Low-Cost, Class D Testing of Spacecraft Photovoltaic Systems Can Reduce Risk

The end-to-end verification of a spacecraft photovoltaic power generation system requires light! A lowcost, portable, and end-to-end photovoltaic-system test appropriate for NASA's new generation of Class D missions is presented. High risk, low-cost, and quick-turn satellites rarely have the resources to execute the traditional approaches from higher-class (A-C) missions. The Class D approach, as demonstrated on the Lunar Atmospheric and Dust Environment Explorer (LADEE), utilizes a portable, metalhalide, theatre lamp for an end-to-end photovoltaic system test. While not as precise and comprehensive as the traditional Large Area Pulsed Solar Simulator (LAPSS) test, the LADEE method leverages minimal resources into an ongoing assessment program that can be applied through numerous stages of the mission. The project takes a true Class D approach in assessing the technical value of a costly, highfidelity performance test versus a simpler approach with less programmatic risk. The resources required are a fraction of that for a LAPSS test, and is easy to repeat due to its portability. Further, the test equipment can be handed down to future projects without building an on-site facility. At the vanguard of Class D missions, the LADEE team frequently wrestled with and challenged the status quo. The philosophy of risk avoidance at all cost, typical to Class A-C missions, simply could not be executed. This innovative and simple testing solution is contextualized to NASA Class D programs and a specific risk encountered during development of the LADEE Electrical Power System (EPS). Selection of the appropriate lamp and safety concerns are discussed, with examples of test results. Combined with the vendor's panellevel data and periodic inspection, the method ensures system integrity from Integration and Test (I&T) through launch. Following launch, mission operations tools are utilized to assess system performance based on a scant amount of available data.

power systems↗

Nonlinear infrared generation in alkali metal vapors: Steady state susceptibilities and dynamic behavior. Effective relaxation rates and preliminary Raman gain predictions for the Cs system

Effective relaxation rates for atomic cesium pumped by doubled Alexandrite radiation are presented. Laser radiation levels are 8S 1/2 and 9S 1/2; resonance levels 3 = 8P 1/2 and 8P 1/2, respectively. In addition, Raman gain is represented in two graphs which plot chi per atom (10 to the -13 power) at Raman peak versus the infrared wave number per centimeter and the corresponding doubled Alexandrite wave number. One graph covers resonance level 8P, the other 9P; in both cases cesium is pumped with a peak pulse height of 0.5 MW in a 200 micron diameter spot size.

Lawandy, N. M.↗

Semispan Test Results of an Active Flow Control Enabled High-Lift Common Research Model in Landing Configuration

A 10%-scale semispan, Active Flow Control (AFC) enabled, simplified high-lift version of the Common Research Model (CRM-SHL-AFC) was tested in the 14- by 22-Foot Subsonic Tunnel at the NASA Langley Research Center. The main objective of the test was to develop an AFC system that can provide the necessary lift recovery on a simple-hinged flap high-lift system while minimizing its pneumatic power requirement. Three new types of AFC approaches were examined: Double-Row Sweeping Jets (DRSWJ), Alternating Pulsed Jets (APJ), and High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used an upstream row of sweeping jets combined with a downstream row of steady jets to overcome strong adverse pressure gradients. The test was conducted mostly at a freestream Mach number of 0.20. For exploration purposes, a limited number of runs were made at lower Mach numbers or using vortex generators (VGs). Minimal sensitivity to Mach number or VGs, for the cases evaluated, were observed. The AFC-induced lift coefficient increment was maintained over the AFC-off case for most flow-control cases examined. The CRM-SHL-AFC configuration equipped with HELP actuation was the only actuator configuration able to match or exceed the targeted lift performance of a reference conventional high-lift configuration. The presented aerodynamic data include lift, drag, and pitching moment coefficients as a function of angle of attack, with and without the Transonic Wall Interference Correction System (TWICS) method applied. Lift increments as a function of AFC pneumatic power usage (i.e., nozzle pressure ratio, mass flow, momentum coefficient, and power coefficient) are also presented at a lower angle of attack (α = 8.9°) and at maximum lift (α= 17.1°). At the two angles of attack, the surface pressure distributions and autospectral densities from the unsteady pressure transducers for the AFC-off case and the best HELP actuation case are compared.

high-lift↗

Low-cost, Risk-Reduction Testing of Class D Spacecraft Photovoltaic Systems

The end-to-end verification of a spacecraft photovoltaic power generation system requires light! A low-cost, portable, and end-to-end photovoltaic-system test appropriate for NASAs new generation of Class D missions is presented. High risk, low-cost, and quick-turn satellites rarely have the resources to execute the traditional approaches from higher-class (A-C) missions. The Class D approach, as demonstrated on the Lunar Atmospheric and Dust Environment Explorer (LADEE), utilizes a portable, metal-halide, theatre lamp for an end-to-end photovoltaic system test. While not as precise and comprehensive as the traditional Large Area Pulsed Solar Simulator (LAPSS) test, the LADEE method leverages minimal resources into an ongoing assessment program that can be applied through numerous stages of the mission. The project takes a true Class D approach in assessing the technical value of a costly, high-fidelity performance test versus a simpler approach with less programmatic risk. The resources required are a fraction of that for a LAPSS test, and is easy to repeat due to its portability. Further, the test equipment can be handed down to future projects without building an on-site facility.At the vanguard of Class D missions, the LADEE team frequently wrestled with and challenged the status quo. The philosophy of risk avoidance at all cost, typical to Class A-C missions, simply could not be executed. This innovative and simple testing solution is contextualized to NASA Class D programs and a specific risk encountered during development of the LADEE Electrical Power System (EPS). Selection of the appropriate lamp and safety concerns are discussed, with examples of test results. Combined with the vendors panel-level data and periodic inspection, the method ensures system integrity from Integration and Test (IT) through launch. Following launch, mission operations tools are utilized to assess system performance based on a scant amount of available data.

photovoltaic↗

Interaction of solar wind with the magnetopause-boundary layer and generation of magnetic impulse events

The transport of mass, momentum, energy and waves from the solar wind to the Earth's magnetosphere takes place in the magnetopause-boundary layer region. Various plasma processes that may occur in this region have been proposed and studied. In this paper, we present a brief review of the plasma processes in the dayside magnetopause-boundary layer. These processes include (1) flux transfer events at the dayside magnetopause, (2) formation of plasma vortices in the low-latitude boundary layer by the Kelvin-Helmholtz instability and coupling to the polar ionosphere, (3) the response of the magnetopause to the solar wind dynamic pressure pulses, and (4) the impulsive penetration of solar wind plasma filaments through the dayside magnetopause into the magnetospheric boundary layer. Through the coupling of the magnetopause-boundary layer to the polar ionosphere, those above processes may lead to occurrence of magnetic impulse events observed in the high-latitude stations.

Lee, L. C.↗

Spike train generation and current-to-frequency conversion in silicon diodes

A device physics model is developed to analyze spontaneous neuron-like spike train generation in current driven silicon p(+)-n-n(+) devices in cryogenic environments. The model is shown to explain the very high dynamic range (0 to the 7th) current-to-frequency conversion and experimental features of the spike train frequency as a function of input current. The devices are interesting components for implementation of parallel asynchronous processing adjacent to cryogenically cooled focal planes because of their extremely low current and power requirements, their electronic simplicity, and their pulse coding capability, and could be used to form the hardware basis for neural networks which employ biologically plausible means of information coding.

Coon, D. D.↗

Application of Circulation Control Technology to Airframe Noise Reduction

This report is a summary of the work performed by Georgia Tech Research Institute (GTRI) under NASA Langley Grant NAG-1-2146, which was awarded as a part of NASA's Breakthrough Innovative Technologies (BIT) initiative. This was a three-year program, with a one-year no-cost extension. Each year's study has been an integrated effort consisting of computational fluid dynamics, experimental aerodynamics, and detailed noise and flow measurements. Year I effort examined the feasibility of reducing airframe noise by replacing the conventional wing systems with a Circulation Control Wing (CCW), where steady blowing was used through the trailing edge of the wing over a Coanda surface. It was shown that the wing lift increases with CCW blowing and indeed for the same lift, a CCW wing was shown to produce less noise. Year 2 effort dealt with a similar study on the role of pulsed blowing on airframe noise. The main objective of this portion of the study was to assess whether pulse blowing from the trailing edge of a CCW resulted in more, less, or the same amount of radiated noise to the farfield. Results show that a reduction in farfield noise of up to 5 dB is measured when pulse flow is compared with steady flow for an equivalent lift configuration. This reduction is in the spectral region associated with the trailing edge jet noise. This result is due to the unique advantage that pulsed flow has over steady flow. For a range of frequencies, more lift is experienced with the same mass flow as the steady case. Thus, for an equivalent lift and slot height, the pulsed system can operate at lower jet velocities, and hence lower jet noise. The computational analysis showed that for a given time-averaged mass flow rate, pulsed jets give a higher value of C(sub l) and a higher L/D than equivalent steady jets. This benefit is attributable to higher instantaneous jet velocities, and higher instantaneous C(sub mu) values for the pulsed jet. Pulsed jet benefits increase at higher frequencies. However, these advantages are somewhat offset by the unsteadiness in the loads, which will cause structural vibrations and fatigue. Additional studies must be done, perhaps with multiple jets on the upper and lower surfaces, to smooth out the fluctuations in lift while retaining the benefits. The rest of the effort was devoted to examining ways of reducing flap edge noise by blowing air through a Coanda nozzle over a rounded tip of the flap. In this case, we were successful in moving the tip vortex away from the tip, but the device producing the blowing was noisy and we were unable to examine the noise benefits, although we believe that the movement of the tip vortex far from the tip should provide noise benefits. It should be noted that in an effort to understand the fluid dynamics and the aeroacoustics of a jet blowing over a Coanda surface, we also carried out a very extensive study of the high aspect ratio slot jets. A first-ever set of far-field noise spectra were measured for jets exhausting from slots with aspect ratios in the range 100 to 3000. Parallel measurements of velocity profiles, length scales and convection velocities were measured to understand the noise generation of high aspect ratio jets. Attempts were also made to develop jet noise prediction schemes for such jets. Much of the work done under this effort has been described in five conference papers and two doctoral theses. The first year s work on the use of steady blowing was described in two AIAA papers presented at the 2001 AIAA Aerospace Sciences Meeting in Reno. Subsequent work was presented at the 9th AIMCEAS Aeroacoustics Conference and Exhibit held at Hilton Head May 12-13. Another paper is to be presented at the 2004 AIAA Aerospace Sciences Meeting in Reno in January 2004. All six papers are included with this report as Appendices. The bulk of the experimental work done in an effort to produce a pulsed flow that is free of upstream noise is also attached as an Appendix.

Ahuja, K. K.↗

The response of a 300 micron silicon detector to monoenergetic neutrons determined by the use of the Monte Carlo technique

The response of a 300 micron thick silicon detector to an incident monoenergetic neutron beam is evaluated by the Monte Carlo method for the cases of both a shielded and a bare detector. The result of Monte Carlo calculation, using elastic, inelastic, and absorption reactions indicates that the response of the silicon detector to neutrons is basically due to the elastic scattering. In addition, the gamma rays generated in the shield of the detector will result in a response which is 3 or 4 orders of magnitude smaller than response to incident photons. The response of a bare silicon detector is calculated for neutron energies up to 6 MeV and bias energies from 50 to 250 KeV. It is found that the maximum response for a 300 micron thick silicon detector is less than .004 c/n within this selected neutron and bias energy range. When the pulse height defect is introduced in the calculation the results at low energy neutrons were reduced.

Tahezadeh, M.↗

Flap-Edge Blowing Experiments

This Appendix documents the salient results from an effort to mitigate the so-called flap-edge noise generated at the split between a flap edge that is deployed and the undeployed flap. Utilizing a Coanda surface installed at the flap edge, steady blowing was used in an attempt to diminish the vortex strength resulting from the uneven lift distribution. The strength of this lifting vortex was augmented by steady blowing over the deployed flap. The test article for this study was the same 2D airfoil used in the steady blowing program reported earlier (also used in pulsed blowing tests, see Appendix G), however its trailing edge geometry was modified. An exact duplicate of the airfoil shape was made out of fiberglass with no flap, and in the clean configuration. It was attached to the existing airfoil to make an airfoil that has half of its flap deployed and half un-deployed. Figure 1 shows a schematic of the planform showing the two areas where steady blowing was introduced. The flap-edge blowing or the auxiliary blowing was in the direction normal to the freestream velocity vector. Slot heights for the blowing chambers were on the order of 0.0 14 inches.

Gaeta, R. J.↗

Methods and Piezoelectric Imbedded Sensors for Damage Detection in Composite Plates Under Ambient and Cryogenic Conditions

New methods for structural health monitoring are being assessed, especially in high-performance, extreme environment, safety-critical applications. One such application is for composite cryogenic fuel tanks. The work presented here attempts to characterize and investigate the feasibility of using imbedded piezoelectric sensors to detect cracks and delaminations under cryogenic and ambient conditions. A variety of damage detection methods and different Sensors are employed in the different composite plate samples to aid in determining an optimal algorithm, sensor placement strategy, and type of imbedded sensor to use. Variations of frequency, impedance measurements, and pulse echoing techniques of the sensors are employed and compared. Statistical and analytic techniques are then used to determine which method is most desirable for a specific type of damage. These results are furthermore compared with previous work using externally mounted sensors. Results and optimized methods from this work can then be incorporated into a larger composite structure to validate and assess its structural health. This could prove to be important in the development and qualification of any 2" generation reusable launch vehicle using composites as a structural element.

Engberg, Robert↗

Development of the Optical Communications Telescope Laboratory: A Laser Communications Relay Demonstration Ground Station

The Laser Communications Relay Demonstration (LCRD) project will demonstrate high bandwidth space to ground bi-directional optical communications links between a geosynchronous satellite and two LCRD optical ground stations located in the southwestern United States. The project plans to operate for two years with a possible extension to five. Objectives of the demonstration include the development of operational strategies to prototype optical link and relay services for the next generation tracking and data relay satellites. Key technologies to be demonstrated include adaptive optics to correct for clear air turbulence-induced wave front aberrations on the downlink, and advanced networking concepts for assured and automated data delivery. Expanded link availability will be demonstrated by supporting operations at small sun-Earth-probe angles. Planned optical modulation formats support future concepts of near-Earth satellite user services to a maximum of 1.244 Gb/s differential phase shift keying modulation and pulse position modulations formats for deep space links at data rates up to 311 Mb/s. Atmospheric monitoring instruments that will characterize the optical channel during the link include a sun photometer to measure atmospheric transmittance, a solar scintillometer, and a cloud camera to measure the line of sight cloud cover. This paper describes the planned development of the JPL optical ground station.

optical commuication↗

High voltage power supply

A high voltage power supply is formed by three discrete circuits energized by a battery to provide a plurality of concurrent output signals floating at a high output voltage on the order of several tens of kilovolts. In the first two circuits, the regulator stages are pulse width modulated and include adjustable ressistances for varying the duty cycles of pulse trains provided to corresponding oscillator stages while the third regulator stage includes an adjustable resistance for varying the amplitude of a steady signal provided to a third oscillator stage. In the first circuit, the oscillator, formed by a constant current drive network and a tuned resonant network included a step up transformer, is coupled to a second step up transformer which, in turn, supplies an amplified sinusoidal signal to a parallel pair of complementary poled rectifying, voltage multiplier stages to generate the high output voltage.

Ruitberg, A. P.↗

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka↗