Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Towards a very precise knowledge of {theta}{sub 13}

Recent experimental developments towards obtaining a very precise value of the third neutrino mixing angle, {theta}{sub 13}, are summarized. Various implications of the measured value of this angle are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision atomic data for halo nuclei and related nuclear structure

Nuclear charge radii of the lightest neutron-halo isotopes {sup 6,8}He, {sup 11}Li, and {sup 11}Be have been measured during the last decade using tailored laser-spectroscopic techniques for the needs of high-accuracy isotope shift measurements on millisecond-isotopes with very low production yields. Nuclear charge radii can be extracted using high-precision calculations of the mass-shift contribution and the electronic factor of the finite-nuclear-size effect. These results are important benchmarks for nuclear structure theory and give access to the correlations between halo neutrons and average distances of the halo neutrons from the core nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators

A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Project 8: Precision Electron Specroscopy to Measure the Mass of the Neutrino

The Project 8 Collaboration is exploring a new technique for the spectroscopy of medium-energy electrons (* 1 – 100 keV) with the ultimate goal of measuring the effective mass of the electron antineutrino by the tritium endpoint method. Our method is based on the detection of microwave-frequency cyclotron radiation emitted by magnetically trapped electrons. The immediate goal of Project 8 is to demonstrate the utility of this technique for a tritium endpoint experiment through a high-precision measurement of the conversion electron spectrum of 83mKr. We present concepts for detecting this cyclotron radiation, focusing on a guided wave design currently being implemented in a prototype apparatus at the University of Washington.

neutrino, tritium, beta decay, krypton-83, convers↗

Controlling precise magnetic field configuration around electron cyclotron resonance zone for enhancing plasma parameters and beam current

Multi-charged ion source which has wide operating conditions is required in various application fields. We have constructed tandem type ECR ion source (ECRIS); one of the features of its main stage is an additional coil for controlling magnetic field distribution around the mirror bottom precisely. Here the effect of magnetic field variation caused by the additional coil is experimentally considered in terms of plasma parameters and beam current as the first investigation of the main stage plasma. Furthermore, behavior of magnetic lines of force flowing from the ECR zone is calculated, and is compared with measurement results aiming for better understanding of interrelationship between plasma production and ion beam generation on the ECRIS.

43 PARTICLE ACCELERATORS↗

Precision phase control for the radio frequency system of K500 superconducting cyclotron at Variable Energy Cyclotron Centre, Kolkata

Variable Energy Cyclotron Centre (VECC) has commissioned K500 Superconducting cyclotron (SCC) based on MSU and Texas A and M university cyclotrons. The radio frequency (RF) system of SCC has been commissioned with the stringent requirement of various RF parameters. The three-phase RF system of Superconducting cyclotron has been developed in the frequency range 9–27 MHz with amplitude and phase stability of 100 ppm and ±0.1°, respectively. The phase control system has the option to change the relative phase difference between any two RF cavities and maintain the phase stability within ±0.1° during round-the-clock cyclotron operation. The said precision phase loop consists of both analogue In-phase/Quadrature modulator to achieve faster response and also Direct Digital Synthesis based phase shifter to achieve wide dynamic range as well. This paper discusses detail insights into the various issues of phase control for the K500 SCC at VECC, Kolkata.

43 PARTICLE ACCELERATORS↗

Nucleon measurements at the precision frontier

We comment on nucleon measurements at the precision frontier. As examples of what can be learned, we concentrate on three topics, which are parity violating scattering experiments, the proton radius puzzle, and the symbiosis between nuclear and atomic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design improvement of the three-beam detector towards a precise long-range 6-degree of freedom motion sensor system

This paper presents performance enhancement of the three beam detector through design improvement based on the error analysis. The three-beam detector is a novel sensor system that measures six motions (i.e., 3 translations and 3 rotations) of a remote object with high accuracy by implementing three laser distance sensors and a vision sensor. In this paper, finite element analysis and parameter analysis are applied to the three-beam detector to analyze its structural frames and sensor configuration, respectively, in terms of sensing error. By virtue of such a systematic, quantitative error analysis, this research has successfully improved the performance of the three-beam detector and thoroughly validated through field tests that it can detect the 6-degree of freedom motions of a remote target at 30 m with an accuracy of 1.51 mm and 0.18° and precision of 0.38 mm and 0.13°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen-bonded aggregates in precise acid copolymers

We perform atomistic molecular dynamics simulations of melts of four precise acid copolymers, two poly(ethylene-co-acrylic acid) (PEAA) copolymers, and two poly(ethylene-co-sulfonic acid) (PESA) copolymers. The acid groups are spaced by either 9 or 21 carbons along the polymer backbones. Hydrogen bonding causes the acid groups to form aggregates. These aggregates give rise to a low wavevector peak in the structure factors, in agreement with X-ray scattering data for the PEAA materials. The structure factors for the PESA copolymers are very similar to those for the PEAA copolymers, indicating a similar distance between aggregates which depends on the spacer length but not on the nature of the acid group. The PEAA copolymers are found to form more dimers and other small aggregates than do the PESA copolymers, while the PESA copolymers have both more free acid groups and more large aggregates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision measurement of transverse velocity distribution of a strontium atomic beam

We measure the transverse velocity distribution in a thermal Sr atomic beam precisely by velocity-selective saturated fluorescence spectroscopy. The use of an ultrastable laser system and the narrow intercombination transition line of Sr atoms mean that the resolution of the measured velocity can reach 0.13 m/s, corresponding to 90 μK in energy units. The experimental results are in very good agreement with the results of theoretical calculations. Based on the spectroscopic techniques used here, the absolute frequency of the intercombination transition of {sup 88}Sr is measured using an optical-frequency comb generator referenced to the SI second through an H maser, and is given as 434 829 121 318(10) kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-charge detection by an atomic precision tunnel junction

We demonstrate sensitive detection of single charges using a planar tunnel junction 8.5 nm wide and 17.2 nm long defined by an atomically precise phosphorus doping profile in silicon. The conductance of the junction responds to a nearby gate potential and also to changes in the charge state of a quantum dot patterned 52 nm away. The response of this detector is monotonic across the entire working voltage range of the device, which will make it particularly useful for studying systems of multiple quantum dots. The charge sensitivity is maximized when the junction is most conductive, suggesting that more sensitive detection can be achieved by shortening the length of the junction to increase its conductance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision control of thermal transport in cryogenic single-crystal silicon devices

We report on the diffusive-ballistic thermal conductance of multi-moded single-crystal silicon beams measured below 1 K. It is shown that the phonon mean-free-path ℓ is a strong function of the surface roughness characteristics of the beams. This effect is enhanced in diffuse beams with lengths much larger than ℓ, even when the surface is fairly smooth, 5–10 nm rms, and the peak thermal wavelength is 0.6 μm. Resonant phonon scattering has been observed in beams with a pitted surface morphology and characteristic pit depth of 30 nm. Hence, if the surface roughness is not adequately controlled, the thermal conductance can vary significantly for diffuse beams fabricated across a wafer. In contrast, when the beam length is of order ℓ, the conductance is dominated by ballistic transport and is effectively set by the beam cross-sectional area. We have demonstrated a uniformity of ±8% in fractional deviation for ballistic beams, and this deviation is largely set by the thermal conductance of diffuse beams that support the micro-electro-mechanical device and electrical leads. In addition, we have found no evidence for excess specific heat in single-crystal silicon membranes. This allows for the precise control of the device heat capacity with normal metal films. We discuss the results in the context of the design and fabrication of large-format arrays of far-infrared and millimeter wavelength cryogenic detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-precision instrument for measuring the surface tension, viscosity and surface viscoelasticity of liquids using ripplon surface laser-light scattering with tunable wavelength selection

Here we describe our new high-precision instrument that simultaneously measures the surface tension, viscosity, and surface viscoelasticity of liquids. The instrument works on the ripplon surface-laser light scattering principle and operates with an automatically tunable selection of ripplon wavelength from 4 to 1500 μm, which corresponds to the frequency range of observing surface phenomena from approximately 400 Hz to 3 MHz in the case of water. The heterodyne technique instrument uses a reference laser beam which intersects at an arbitrarily adjustable angle with a vertically directed probing beam. For the determination of the wavelength of selected ripplons we substituted with the interference fringe spacing, measured using a high-resolution beam profiler. To extract reliable surface tension and viscosity data from the experimentally obtained spectrum shape for a selected wavelength of ripplon, we developed an algorithm to calculate the exact solution of the dispersion equation. The uncertainties of surface tension and viscosity measurement were confirmed through the measurement of seven pure Newtonian liquids at 25 °C measured with the selected wavelength of ripplon from 40 μm to 467 μm. To verify the genuine capability of the tunable wavelength selection of ripplon, we measured the surface elasticity of soluble surface molecular layers spread on pentanoic acid solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high precision, compact electromechanical ground rotation sensor

We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of 1 × 10{sup −11}m/√( Hz ). We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of 5.7 × 10{sup −9} rad /√( Hz ) at 10 mHz and 6.4 × 10{sup −10} rad /√( Hz ) at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

42 ENGINEERING↗

Precisely predicting and designing the elasticity of metallic glasses

We reveal that the elastic moduli of metallic glasses (MGs) invariably vary in a much steeper manner than that predicted by the conventional “rule of mixtures” in individual alloy systems. Such deviations are proved to originate fundamentally from their disordered atomic structures and intrinsic local heterogeneities. By treating the MGs as atomic-level dual phase hybrids, we further propose universal relations to be capable of precisely predicting and designing the elastic constants of MGs. This may contribute to the development of MGs with intended properties and behaviors, and allow new understandings on the structures and properties as well as their relationships in MGs.

42 ENGINEERING↗

A widely tunable 10-μm quantum cascade laser phase-locked to a state-of-the-art mid-infrared reference for precision molecular spectroscopy

We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-μm to the secondary frequency standard of this spectral region, a CO{sub 2} laser stabilized on a saturated absorption line of OsO{sub 4}. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH{sub 3} and methyltrioxorhenium, two species of interest for applications in precision measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs

We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗