Excitation of vibrational quanta in furfural by intermediate-energy electrons

We report cross sections for electron-impact excitation of vibrational quanta in furfural, at intermediate incident electron energies (20, 30, and 40 eV). The present differential cross sections are measured over the scattered electron angular range 10°–90°, with corresponding integral cross sections subsequently being determined. Furfural is a viable plant-derived alternative to petrochemicals, being produced via low-temperature plasma treatment of biomass. Current yields, however, need to be significantly improved, possibly through modelling, with the present cross sections being an important component of such simulations. To the best of our knowledge, there are no other cross sections for vibrational excitation of furfural available in the literature, so the present data are valuable for this important molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theory of the electron sheath and presheath

Here, electron sheaths are commonly found near Langmuir probes collecting the electron saturation current. The common assumption is that the probe collects the random flux of electrons incident on the sheath, which tacitly implies that there is no electron presheath and that the flux collected is due to a velocity space truncation of the electron velocity distribution function (EVDF). This work provides a dedicated theory of electron sheaths, which suggests that they are not so simple. Motivated by EVDFs observed in particle-in-cell(PIC) simulations, a 1D model for the electron sheath and presheath is developed. In the model, under low temperature plasma conditions (T e >> T i ), an electron pressure gradient accelerates electrons in the presheath to a flow velocity that exceeds the electron thermal speed at the sheath edge. This pressure gradient generates large flow velocities compared to what would be generated by ballistic motion in response to the electric field. It is found that in many situations, under common plasma conditions, the electron presheath extends much further into the plasma than an analogous ion presheath. PIC simulations reveal that the ion density in the electron presheath is determined by a flow around the electron sheath and that this flow is due to 2D aspects of the sheath geometry. Simulations also indicate the presence of ion acoustic instabilities excited by the differential flow between electrons and ions in the presheath, which result in sheath edge fluctuations. The 1D model and time averaged PIC simulations are compared and it is shown that the model provides a good description of the electron sheath and presheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practicality of magnetic compression for plasma density control

Here, plasma densification through magnetic compression has been suggested for time-resolved control of the wave properties in plasma-based accelerators [P. F. Schmit and N. J. Fisch, Phys. Rev. Lett. 109, 255003 (2012)]. Using particle in cell simulations with real mass ratio, the practicality of large magnetic compression on timescales shorter than the ion gyro-period is investigated. For compression times shorter than the transit time of a compressional Alfven wave across the plasma slab, results show the formation of two counter-propagating shock waves, leading to a highly non-uniform plasma density profile. Furthermore, the plasma slab displays large hydromagnetic like oscillations after the driving field has reached steady state. Peak compression is obtained when the two shocks collide in the mid-plane. At this instant, very large plasma heating is observed, and the plasmaβ is estimated to be about 1. Although these results point out a densification mechanism quite different and more complex than initially envisioned, these features still might be advantageous in particle accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation metrics for turbulent plasma transport

Developing accurate models of plasma dynamics is essential for confident predictive modeling of current and future fusion devices. In modern computer science and engineering, formal verification and validation processes are used to assess model accuracy and establish confidence in the predictive capabilities of a given model. This paper provides an overview of the key guiding principles and best practices for the development of validation metrics, illustrated using examples from investigations of turbulent transport in magnetically confined plasmas. Particular emphasis is given to the importance of uncertainty quantification and its inclusion within the metrics, and the need for utilizing synthetic diagnostics to enable quantitatively meaningful comparisons between simulation and experiment. As a starting point, the structure of commonly used global transport model metrics and their limitations is reviewed. An alternate approach is then presented, which focuses upon comparisons of predicted local fluxes, fluctuations, and equilibrium gradients against observation. The utility of metrics based upon these comparisons is demonstrated by applying them to gyrokinetic predictions of turbulent transport in a variety of discharges performed on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)], as part of a multi-year transport model validation activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500–2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ~20 μm thickness have been performed. X-ray yields of up to ~1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ~100 μm FWHM, with ~350 ps pulse duration during the peak emission stage. Lastly, these results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instability of nonlinear Trivelpiece-Gould waves. II. Weakly trapped particles

This paper discusses a novel parametric instability mechanism caused by particles that are weakly trapped in the potential wells of a nonlinear “pump” wave. The pump wave is unstable to the growth of daughter waves with longer wavelength and nearly the same phase velocity as the pump. This induces adjacent potential peaks in the wave to slowly approach one-another, receding from other pairs of peaks. Particles that are weakly trapped between approaching peaks, with kinetic energies just below the potential maxima, are heated by compression and escape the well, and then become retrapped on the other side of the approaching peaks, where they amplify the compression by pushing the peaks together. The mechanism applies to low-collisionality plasmas supporting waves with near-acoustic dispersion relations such as ion sound waves, magnetized Langmuir waves, or Alfven waves. The theory is compared to particle in cell simulations of TrivelpieceGould (TG) traveling waves, as well as to experiments on pure ion plasmas that observe parametric instability in TG standing waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-induced fluorescence measurements of ion fluctuations in electron and ion presheaths

Electrostatic flow-driven instabilities have been predicted in the presheath region of low-temperature plasmas for both ion and electron rich sheaths. The ion-acoustic fluctuations that arise from these instabilities can influence transport through an enhanced collision rate. In this work, ion fluctuation spectra were measured using laser-induced fluorescence (LIF) in the presheath region for both sheath polarities. Furthermore, the non-invasive nature of LIF compared to that of probes is particularly valuable for these measurements because the sheath and presheath around a probe may generate their own flow-driven instabilities, which obscure the measurement. Measurements were made using a recently implemented field programmable gate array-based system able to measure ion fluctuation spectra up to 1 MHz using a two-point correlation function technique. Narrow bandwidth ion fluctuations were observed near 0:46 f pi (460 kHz) for both sheath polarities, where f pi is the ion plasma frequency. The observed fluctuations were significantly stronger in the electron sheath case and were observed over a larger volume of plasma. Fluctuations were measured in the ion sheath case at locations far enough from the sheath that linear theory predicts stability, suggesting that ion-acoustic instabilities generated in the relatively small unstable region near the boundary reflect from the sheath and perturb a much larger volume of the plasma. This is expected to affect probes with both ion and electron rich sheaths, meaning any dc biased probe may effectively act as an ion-acoustic wave antenna. These measurements are consistent with the recent theory and particle-in-cell results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Billion-pixel x-ray camera (BiPC-X)

The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 μm) enable billion-pixel x-ray cameras (BiPC-X) based on commercial complementary metal–oxide–semiconductor (CMOS) imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy x rays (<10 keV) and indirect detection of higher energies using scintillators. Modified Birks’s law is proposed for light yield non-proportionality in scintillators as a function of x-ray energy. Single x-ray sensitivity and spatial resolution have been validated experimentally using a laboratory x-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view or large x-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, x-ray free electron laser, and pulsed power facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lagrangian particle simulation of hydrogen pellets and SPI into runaway electron beam in ITER

Numerical studies of the ablation of pellets and shattered pellet injection (SPI) fragments into a runaway electron beam in ITER have been performed using a time-dependent pellet ablation code [Samulyak et al., Nucl. Fusion, 61(4), 046007 (2021)]. The code resolves detailed ablation physics near pellet fragments and large-scale expansion of ablated clouds. The study of a single-fragment ablation quantifies the influence of various factors, in particular, the impact ionization by runaway electrons and cross-field transport models, on the dynamics of ablated plasma and its penetration into the runaway beam. Simulations of SPI performed using different numbers of pellet fragments study the formation and evolution of the ablation clouds and their large-scale dynamics in ITER. In conclusion, the penetration depth of the ablation clouds is found to be of the order of 50 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-n Rydberg transition spectroscopy for heavy impurity transport studies in W7-X (invited)

Here, we present a novel spectroscopy approach to investigate impurity transport by analyzing line-radiation following high-n Rydberg transitions. While high-n Rydberg states of impurity ions are unlikely to be populated via impact excitation, they can be accessed by charge exchange (CX) reactions along the neutral beams in high-temperature plasmas. Hence, localized radiation of highly ionized impurities, free of passive contributions, can be observed at multiple wavelengths in the visible range. For the analysis and modeling of the observed Rydberg transitions, a technique for calculating effective emission coefficients is presented that can well reproduce the energy dependence seen in datasets available on the OPEN-ADAS database. By using the rate coefficients and comparing modeling results with the new high-n Rydberg CX measurements, impurity transport coefficients are determined with well-documented 2σ confidence intervals for the first time. This demonstrates that high-n Rydberg spectroscopy provides important constraints on the determination of impurity transport coefficients. By additionally considering Bolometer measurements, which provide constraints on the overall impurity emissivity and, therefore, impurity densities, error bars can be reduced even further.

Instruments & Instrumentation↗

Detection of atomic oxygen and its electronic coherence decays using time-resolved ultrafast coherent Raman scattering

We report the detection of atomic oxygen and quantitative measurements of its electronic Raman coherence decays in flames and low-temperature plasmas using time-resolved hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (CARS). Atomic oxygen was detected using the Raman transitions between the spin–orbit coupled triplet ground states. Atomic oxygen was generated in an H 2 /O 2 /Ar diffusion flame and an O 2 /Ar pulsed plasma discharge. Single exponential decays were observed for the O( 3 P 2 )–O( 3 P 1 ) Raman transition at 158.3 cm −1 and the O( 3 P 2 )–O( 3 P 0 ) Raman transition at 227 cm −1 . From the decay measurements, the atomic O Raman linewidths were obtained from 25 to 150 Torr in non-equilibrium plasma and at 760 Torr in a flame. Enhanced signal-to-noise ratios (SNRs) of atomic oxygen and atomic to molecular oxygen signal contrasts were obtained by taking advantage of electronic triplet coherence beating. Enhancement of up to seven times in the atomic O SNR was observed. Furthermore, we also found that the dephasing rates of O 2 (v = 0–3, N = 37) were similar, which provides evidence for the assumption that vibrational excitation does not influence the dephasing of diatomic molecular rotational CARS transitions.

Atomic and molecular spectroscopy↗

A STUDY OF THE LOW-MASS X-RAY BINARY DIP SOURCES XB 1916 - 053, XB 1323 - 619, X 1624 - 490 AND 4U 1746 - 371 OBSERVED WITH INTEGRAL

We detect dipping activity/modulations in the light curve of the four low-mass X-ray binaries in the 3-10 keV and 20-40 keV energy ranges. The spectral parameters derived from the fits to the International Gamma-Ray Astrophysics Laboratory data are consistent with hot coronal structures in these systems where we find a range of plasma temperatures 3.0-224.9 keV. The unabsorbed X-ray to soft gamma-ray fluxes between 4 keV and 200 keV are 5.9 x 10{sup -10} erg s{sup -1} cm{sup -2} for XB 1916 - 053, 3.3 x 10{sup -10} erg s{sup -1} cm{sup -2} for XB 1323 - 619, 21.6 x 10{sup -10} erg s{sup -1} cm{sup -2} for X 1624 - 490, and 11.0 x 10{sup -10} erg s{sup -1} cm{sup -2} for 4U 1746 - 371. The optical depth to Compton scattering, {tau}, varies in a range 4.4-0.002 consistent with electron densities n {sub e} < 1.4 x 10{sup 15} cm{sup -3}. In general, we find no significant difference in the dip and non-dip spectra in the ISGRI energy range (above 20 keV) for all the four sources. We only detect absorption differences between dipping and non-dipping intervals for XB 1916 - 053 and X 1624 - 490 in the JEM-X energy range. Fits in the 4-200 keV range including an additional photoionized absorber model for the two sources show that XB 1916 - 053 has the highest ionized absorber among the two.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY EMISSION FROM THE FU ORIONIS STAR V1735 CYGNI

The variable star V1735 Cyg (=Elias 1-12) lies in the IC 5146 dark cloud and is a member of the class of FU Orionis objects whose dramatic optical brightenings are thought to be linked to episodic accretion. We report the first X-ray detections of V1735 Cyg and a deeply embedded class I protostar lying 24'' to its northeast. X-ray spectra obtained with EPIC on XMM-Newton reveal very high-temperature plasma (kT > 5 keV) in both objects, but no large flares. Such hard X-ray emission is not anticipated from accretion shocks and is a signature of magnetic processes. We place these new results into the context of what is presently known about the X-ray properties of FU Orionis stars and other accreting young stellar objects.

99 GENERAL AND MISCELLANEOUS↗

THE ACCRETION DISK CORONA AND DISK ATMOSPHERE OF 4U 1624-490 AS VIEWED BY THE CHANDRA-HIGH ENERGY TRANSMISSION GRATING SPECTROMETER

We present a detailed spectral study (photoionization modeling and variability) of the 'Big Dipper' 4U 1624-490 based on a Chandra-High Energy Transmission Grating Spectrometer (HETGS) observation over the {approx}76 ks binary orbit of 4U 1624-490 . While the continuum spectrum can be modeled using a blackbody plus power law, a slightly better fit is obtained using a single {gamma} = 2.25 power-law partially (71%) covered by a local absorber of column density N{sub H,Local}=8.1{sub -0.6}{sup +0.7}x10{sup 22} cm{sup -2}. The data show a possible quasi-sinusoidal modulation with period 43{sup +13} {sub -9} ks that might be due to changes in local obscuration. Photoionization modeling with the XSTAR code and variability studies of the observed strong Fe XXV and Fe XXVI absorption lines point to a two-temperature plasma for their origin: a highly ionized component of ionization parameter {xi}{sub hot} {approx} 10{sup 4.3} erg cm s{sup -1} (T {approx} 3.0 x 10{sup 6} K) associated with an extended accretion disk corona of radius R {approx} 3 x 10{sup 10} cm, and a less-ionized more variable component of {xi} {approx} 10{sup 3.4} erg cm s{sup -1} (T {approx} 1.0 x 10{sup 6} K) and {xi}{approx}10{sup 3.1} erg cm s{sup -1} (T {approx} 0.9 x 10{sup 6} K) coincident with the accretion disk rim. We use this, with the observed Fe XXV and Fe XXVI absorption line variations (in wavelength, strength, and width) to construct a viewing geometry that is mapped to changes in plasma conditions over the 4U 1624-490 orbital period.

79 ASTRONOMY AND ASTROPHYSICS↗

STATE TRANSITIONS IN LOW-MASS X-RAY BINARIES

We investigate the model of disk/coronal accretion into a black hole. We show that the inner regions of an accretion disk in X-ray binaries can transform from a cool standard disk to an advection-dominated flow through the known properties of Coulomb interaction in a two-temperature plasma, viscous heating, radiative processes, and thermal conduction. A hot, diffuse corona covering the disk is powered by accretion, but it exchanges mass with the underlying cold disk. If the accretion rate in the system is low enough, we show that the corona evaporates the disk away, leaving an advective flow to continue toward the hole. In the soft/hard transition commonly seen in X-ray binaries, we show that this advective flow can recondense back onto the underlying disk if the change in the system's accretion rate is slow enough due to thermal conduction. Unabsorbed spectra are produced to test against observations as well as prediction of the location of truncation radii of the accretion disk.

79 ASTRONOMY AND ASTROPHYSICS↗

PHYSICAL CONDITIONS IN A CORONAL MASS EJECTION FROM HINODE, STEREO, AND SOHO OBSERVATIONS

In the present work, we analyze multiwavelength observations from Hinode, Solar and Heliospheric Observatory (SOHO), and STEREO of the early phases of a coronal mass ejection (CME). We use Hinode/EIS and SOHO/UVCS high-resolution spectra to measure the physical properties of the CME ejecta as a function of time at 1.1 and 1.9 solar radii. Hinode/XRT images are used in combination with EIS spectra to constrain the high temperature plasma properties of the ejecta. SECCHI/EUVI, SECCHI/COR 1, SOHO/EIT, and SOHO/LASCO images are used to measure the CME trajectory, velocity, and acceleration. The combination of measurements of plane of the sky velocities from two different directions allows us to determine the total velocity of the CME plasma up to 5 solar radii. Plasma properties, dynamical status, thermal structure, and brightness distributions are used to constrain the energy content of the CME plasma and to determine the heating rate. We find that the heating is larger than the kinetic energy, and compare it to theoretical predictions from models of CME plasma heating and acceleration.