Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical constants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Measurement of structure motion by means of a moving light sheet

The elaboration of an optical system which measures the displacement and velocity of large flexible space structures is reviewed. The motion-measuring system, comprised of a laser, optics, motorized mirror, two photodiodes and electronics, is designed to allow feedback for configuration control of flexible structures. A motor or scanner is employed to sweep the light sheet. The range of motion was shown to be 2 inches, and information was received at a rate of 30 Hz. The uncertainty in displacement measurement was better than +0.01 inch from a distance of 16 feet. The results are considered to be very good for two scanning light sheet systems. Higher sample rates and a more constant speed would improve the rotating mirror option, and the accuracy and range of the scanning mirror option could be upgraded as well. Both setups are shown to be viable noncontact measuring methods for the displacement and velocity of large space structures.

Tcheng, Ping↗

On the stability of irradiated accretion disks

The effects of external heating on the stability of hot accretion disks are studied in some detail. It is known that geometrically thin, optically thick, nonirradiated accretion disks have two distinct branches in the surface density mass-accretion rate plane: the upper branch is radiation pressure-dominated and is unstable against thermal and secular perturbations, while the lower one is gas-pressure-dominated and is stable. We show quite generally that, even when disks are strongly irradiated, the upper branch remains unstable and the lower branch remains stable; the lower branch, however, can become radiation pressure dominated, if the irradiating flux, F(irr), is kept constant. A stable, radiation pressure dominated state thus appears. If F(irr) changes in proportion to the mass-accretion rate through the disk, the instabilities associated with radiation pressure dominated disks cannot be removed. Some observational implications are discussed in the context of long-term variations of low-mass X-ray binaries.

Mineshige, Shin↗

A MEMS Micro-Translation Stage with Long Linear Translation

A MEMS Micro-Translation Stage (MTS) actuator concept has been developed that is capable of traveling long distances, while maintaining low power, low voltage, and accuracy as required by many applications, including optical coupling. The Micro-Translation Stage (MTS) uses capacitive electrostatic forces in a linear motor application, with stationary stators arranged linearly on both sides of a channel, and matching rotors on a moveable shuttle. This creates a force that allows the shuttle to be pulled along the channel. It is designed to carry 100 micron-sized elements on the top surface, and can travel back and forth in the channel, either in a stepping fashion allowing many interim stops, or it can maintain constant adjustable speeds for a controlled scanning motion. The MTS travel range is limited only by the size of the fabrication wafer. Analytical modeling and simulations were performed based on the fabrication process, to assure the stresses, friction and electrostatic forces were acceptable to allow successful operation of this device. The translation forces were analyzed to be near 0.5 micron N, with a 300 micron N stop-to-stop time of 11.8 ms.

Ferguson, Cynthia K.↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗

Accounting for the photochemical variation in stratospheric NO2 in the SAGE III/ISS solar occultation retrieval

The Stratospheric Aerosol and Gas Experiment (SAGE) III has been operating on the International Space Station (ISS) since mid-2017. Nitrogen dioxide (NO2) number density profiles are routinely retrieved from SAGE III/ISS solar occultation measurements in the middle atmosphere. Although NO2 density varies throughout the day due to photochemistry, the standard SAGE NO2 retrieval algorithm neglects these variations along the instrument’s line of sight by assuming that the number density has a constant gradient within a given vertical layer of the atmosphere. This assumption will result in a retrieval bias for a species like NO2 that changes rapidly across the terminator. In this work we account for diurnal variations in retrievals of NO2 from the SAGE III/ISS measurements, and we determine the impact of this algorithm improvement on the resulting NO2 number densities. The first step in applying the diurnal correction is to use publicly available SAGE III/ISS products to convert the retrieved number density profiles to optical depth profiles. The retrieval is then re-performed with a new matrix that applies photochemical scale factors for each point along the line of sight according to the changing solar zenith angle. In general NO2 that is retrieved by accounting for these diurnal variations is more than 10% lower than the standard algorithm below 30 km. This effect is greatest in winter at high latitudes and generally greater for sunrise occultations than sunset. Comparisons with coincident profiles from the Optical Spectrograph and InfraRed Imager System (OSIRIS) show that NO2 from SAGE III/ISS is generally biased high; however the agreement improves by up to 20% in the mid-stratosphere when diurnal variations are accounted for in the retrieval. We conclude that diurnal variations along the SAGE III/ISS line of sight are an important term to consider for NO2 analyses at altitudes below 30 km.

Stratospheric NO2↗

Combination of Counterion Size and Doping Concentration Determines the Electronic and Thermoelectric Properties of Semiconducting Polymers

In both chemical and electrochemical doping of organic semiconductors (OSCs), a counterion, either from the electrolyte or ionized dopant, balances the charge introduced to the OSC. Despite the large influence of this counterion on OSC optical and electronic response, there remains substantial debate on how a fundamental parameter, ion size, impacts these properties. Here, this work resolves much of this debate by accounting for two doping regimes. In the low-doping regime, the Coulomb binding energies between charge carriers on the OSC and the counterions are significant, and larger counterions lead to decreased Coulomb interactions, more delocalized charge carriers, and higher electrical conductivities. In the high-doping regime, the Coulomb binding energies become negligible due to the increased dielectric constant of the films and a smoothing of the energy landscape; thereby, the electrical conductivities depend primarily on the extent of morphological disorder in the OSC. Moreover, in regioregular poly(3-hexylthiophene), rr-P3HT, smaller counterions lead to greater bipolaron concentrations in the low-doping regime due to the increased Coulomb interactions. Emphasizing the impact of the counterion size, it is shown that larger counterions can lead to increased thermoelectric power factors for rr-P3HT.

36 MATERIALS SCIENCE↗

Estimation of mean electron energy in helium surface ionization waves on dielectric substrates

Abstract The determination of basic plasma parameters in atmospheric pressure discharges is critical to advancing their use in applications. Atmospheric pressure plasma jets have found use in the fields of medicine, agriculture, material modification and others. Atmospheric pressure plasma jets often generate plasma surface ionization waves (SIW) which interact with and propagate over surfaces. Electrical diagnostics are challenging in SIW due to high collision frequencies and small scale of the plasma discharge. This work employs a passive optical emission line ratio technique to estimate the mean electron energy in SIW over planar dielectric substrates. The method uses an intensity ratio of two helium triplet lines: He( 3 3 S ) at 706.5 nm and He( 3 3 D ) at 587.56 nm. A collisional-radiative model is used to correlate line ratio to mean electron energy and determine dependencies on electron density and He/air gas mixture. Mean electron energies ranging from 3–8 eV are determined in He/air mixtures and are found to remain constant as the surface wave propagates radially. This work provides a 2D, time-resolved, mean electron energy diagnostic for surface ionization wave propagation and validation of numerical modeling in atmospheric pressure systems with spatially varying He/air gas mixtures. The model in question is designed for use with any He line ratio in the n = 3 excitation level.

Morsell, Joshua (ORCID:0000000331073002)↗

A comparison of lidar inversion methods for cirrus applications

Several methods for inverting the lidar equation are suggested as means to derive the cirrus optical properties (beta backscatter, alpha extinction coefficients, and delta optical depth) at one wavelength. The lidar equation can be inverted in a linear or logarithmic form; either solution assumes a linear relationship: beta = kappa(alpha), where kappa is the lidar ratio. A number of problems prevent us from calculating alpha (or beta) with a good accuracy. Some of these are as follows: (1) the multiple scattering effect (most authors neglect it); (2) an absolute calibration of the lidar system (difficult and sometimes not possible); (3) lack of accuracy on the lidar ratio k (taken as constant, but in fact it varies with range and cloud species); and (4) the determination of boundary condition for logarithmic solution which depends on signal to noise ration (SNR) at cloud top. An inversion in a linear form needs an absolute calibration of the system. In practice one uses molecular backscattering below the cloud to calibrate the system. This method is not permanent because the lower atmosphere turbidity is variable. For a logarithmic solution, a reference extinction coefficient (alpha(sub f)) at cloud top is required. Several methods to determine alpha(sub f) were suggested. We tested these methods at low SNR. This led us to propose two new methods referenced as S1 and S2.

Elouragini, Salem↗

Magneto-optic superlattice thin films: Fabrication, structural and magnetic characterization

During this quarter studies were extended to determine the electronic contribution to the perpendicular interface anisotropy in Co-based multilayers. Using in situ Kerr effect measurements, the influences of different transition metals (TM = Ag, Au, Cu, and Pd) on the magnetic properties of single-crystal Co films grown on Pd (111) and Au (111) surfaces are investigated. Last quarter the discovery of a large peak in the perpendicular anisotropy when approximately one monolayer of Cu or Ag is deposited on the Co surface was reported. We now have added a computer-controlled stepper-motor drive to our MBE sample transfer mechanism. The motor allows us to move the sample at a constant velocity from behind a shutter during deposition. The film, therefore, is deposited as a wedge with a linear variation of thickness across the substrate. In this way, a continuous range of coverage on a single sample is studied. The stepper motor also provides the necessary control for precisely positioning the sample in the laser beam for Kerr effect measurements at the different coverages.

Falco, C. M.↗

The tongue of the ocean as a remote sensing ocean color calibration range

In general, terrestrial scenes remain stable in content from both temporal and spacial considerations. Ocean scenes, on the other hand, are constantly changing in content and position. The solar energy that enters the ocean waters undergoes a process of scattering and selective spectral absorption. Ocean scenes are thus characterized as low level radiance with the major portion of the energy in the blue region of the spectrum. Terrestrial scenes are typically of high level radiance with their spectral energies concentrated in the green-red regions of the visible spectrum. It appears that for the evaluation and calibration of ocean color remote sensing instrumentation, an ocean area whose optical ocean and atmospheric properties are known and remain seasonably stable over extended time periods is needed. The Tongue of the Ocean, a major submarine channel in the Bahama Banks, is one ocean are for which a large data base of oceanographic information and a limited amount of ocean optical data are available.

Strees, L. V.↗

Optical and electrical properties of thin superconducting films

Infrared spectroscopic techniques can provide a vital probe of the superconducting energy gap which is one of the most fundamental physical properties of superconductors. Currently, the central questions regarding the optical properties of superconductors are how the energy gap can be measured by infrared techniques and at which frequency the gap exists. An effective infrared spectroscopic method to investigate the superconducting energy gap, Eg, was developed by using the Bomem DA 3.01 Fourier Transformation Spectrophotometer. The reflectivity of a superconducting thin film of YBaCuO deposited on SrTiO3 was measured. A shoulder was observed in the superconducting state reflectance R(sub S) at 480/cm. This gives a value of Eg/kT(sub c) = 7.83, where k is the Boltzmann constant and T(sub c) is the superconducting transition temperature, from which, it is suggested that YBaCuO is a very strong coupling superconductor.

Covington, Billy C.↗

CNO abundances and temperature fluctuations in the Orion Nebula

The largest UV-optical data base to date of the Orion Nebula has been assembled, and the CNO abundances their distribution at a statistically significant number of positions to the north and west of the Trapezium and out to a distance of 5 arcmin has been examined. The forbidden O III temperature increases with distance from Theta1 Ori C while the forbidden N II temperature decreases with increasing distance. The density decreases as a function of increasing distance from Theta1 Ori C. The C/H, N/H, O/H, and C/O distributions are constant across the inner 5 arcmin of the northwestern quadrant of the nebula. The empirically determined mean C/H abundance calculated from UV lines is almost a factor of two lower in the number density than earlier estimates. Photoionization model calculations are consistent with a solar abundance for N/H and O/H.

Walter, Donald K.↗

Metrology Camera System Using Two-Color Interferometry

A metrology system that contains no moving parts simultaneously measures the bearings and ranges of multiple reflective targets in its vicinity, enabling determination of the three-dimensional (3D) positions of the targets with submillimeter accuracy. The system combines a direction-measuring metrology camera and an interferometric range-finding subsystem. Because the system is based partly on a prior instrument denoted the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor and because of its 3D capability, the system is denoted the MSTAR3D. Developed for use in measuring the shape (for the purpose of compensating for distortion) of large structures like radar antennas, it can also be used to measure positions of multiple targets in the course of conventional terrestrial surveying. A diagram of the system is shown in the figure. One of the targets is a reference target having a known, constant distance with respect to the system. The system comprises a laser for generating local and target beams at a carrier frequency; a frequency shifting unit to introduce a frequency shift offset between the target and local beams; a pair of high-speed modulators that apply modulation to the carrier frequency in the local and target beams to produce a series of modulation sidebands, the highspeed modulators having modulation frequencies of FL and FM; a target beam launcher that illuminates the targets with the target beam; optics and a multipixel photodetector; a local beam launcher that launches the local beam towards the multi-pixel photodetector; a mirror for projecting to the optics a portion of the target beam reflected from the targets, the optics being configured to focus the portion of the target beam at the multi-pixel photodetector; and a signal-processing unit connected to the photodetector. The portion of the target beam reflected from the targets produces spots on the multi-pixel photodetector corresponding to the targets, respectively, and the signal-processing unit centroids the spots to determine bearings of the targets, respectively. As the spots oscillate in intensity because they are mixed with the local laser beam that is flood illuminating the focal plane, the phase of oscillation of each spot is measured, the phase of sidebands in the oscillation of each spot being proportional to a distance to the corresponding target relative to the reference target A.

Dubovitsky, Serge↗

In-situ ATR-IR monitoring of hydrothermal carbonation of wollastonite

In-situ reaction monitoring allows for the development of reaction models for hydrothermal carbonation reactions, which have recently gained attention due to their importance in CO 2 sequestration and utilization. Here, we measured the carbonation kinetics of wollastonite (β- CaSiO 3 ) powder compacts under hydrothermal conditions (90°C and 2.4atm) with the help of optical fiber-based attenuated total reflectance infrared spectroscopy (ATR-IR). Further, the fiber probe was positioned at the target area to study the reaction chemistry at the desired region of the powder compact. Absorbances of solid reactants and products were monitored throughout the entire reaction in the 1000–1600cm -1 spectral range. ATR-IR enabled the detection of amorphous silica, which allowed all solid reactants (β-CaSiO 3 ) and products (CaCO 3 and SiO 2 ) to be monitored independently and simultaneously. A linear proportionality constant between absorbance and CaCO 3 phase concentration was determined and used to construct a reaction kinetics profile for carbonate formation, which revealed a rapid reaction onset, followed by two distinct slower decaying regimes.

42 ENGINEERING↗

Photomultiplier window materials under electron irradiation - Fluorescence and phosphorescence

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation have been investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV-grade, optical-grade, and electron-irradiated samples of MgF2 and LiF, and of CaF2, BaF2, sapphire, fused silica, and UV-transmitting glasses were obtained over the 200-650-nm spectral range. Fluorescence yields were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively. Optical-grade MgF2 and LiF, as well as electron-irradiated UV-grade samples of these two materials, show enhanced fluorescence due to color-center formation and associated emission bands in the blue and red wavelength regions. Large variations in fluorescence intensities were found in UV-grade sapphire samples of different origins, particularly in the red end of the spectrum, presumably due to various amounts of chromium-ion content. Phosphorescence decay with time is best described by a sum of exponential terms, with time constants ranging from a few minutes to several days.

Viehmann, W.↗

Integration and Testing of the Lunar Reconnaissance Orbiter Attitude Control System

Throughout the Lunar Reconnaissance Orbiter (LRO) Integration and Testing (I&T) phase of the project, the Attitude Control System (ACS) team completed numerous tests on each hardware component in ever more flight like environments. The ACS utilizes a select group of attitude sensors and actuators. This paper chronicles the evolutionary steps taken to verify each component was constantly ready for flight as well as providing invaluable trending experience with the actual hardware. The paper includes a discussion of each ACS hardware component, lessons learned of the various stages of I&T, a discussion of the challenges that are unique to the LRO project, as well as a discussion of work for future missions to consider as part of their I&T plan. LRO ACS sensors were carefully installed, tested, and maintained over the 18 month I&T and prelaunch timeline. Care was taken with the optics of the Adcole Coarse Sun Sensors (CSS) to ensure their critical role in the Safe Hold mode was fulfilled. The use of new CSS stimulators provided the means of testing each CSS sensor independently, in ambient and vacuum conditions as well as over a wide range of thermal temperatures. Extreme bright light sources were also used to test the CSS in ambient conditions. The integration of the two SELEX Galileo Star Trackers was carefully planned and executed. Optical ground support equipment was designed and used often to check the performance of the star trackers throughout I&T in ambient and thermal/vacuum conditions. A late discovery of potential contamination of the star tracker light shades is discussed in this paper. This paper reviews how each time the spacecraft was at a new location and orientation, the Honeywell Miniature Inertial Measurement Unit (MIMU) was checked for data output validity. This gyro compassing test was performed at several key testing points in the timeline as well as several times while LRO was on the launch pad. Sensor alignment tests were completed several times to ensure that hardware remained on a rigid platform.

Simpson, Jim↗

The application of far IR lasers to the investigation of the optical properties of materials

The effect of diffusion on the saturation and absorption properties of molecular gases is considered. The analysis starts with a simple derivation of the multi-level rate equations. Incorporating the diffusion term, calculations are carried out both for the homogeneous and inhomogeneous broadening cases. Both graphical and analytical solutions are obtained for the absorption coefficient and the saturation intensity. It is shown that the effect of diffusion is characterized by a diffusion function, which varies inversely with the radius of the beam at low pressures and small beam sizes. The analysis is done in terms of two parameters k1a and k2a, which are simple functions of the intensity of the beam I, the effective relaxation rate w, and the effective diffusion constant D the a is designated as the radius of the beam.

Stafsudd, O. M.↗

Quantum sensing of paramagnetic analytes by nanodiamonds in levitated microdroplets and aqueous solutions

Nanodiamonds (ND) hosting negatively charged nitrogen-vacancy (NV-) color centers have received attention for applications in magnetic field, electric field, chemical, and bio-sensing. The versatility of these probes is their excellent room-temperature optical and spin properties, along with their small size, functionalized surfaces and resistance to bleaching, making them ideal as nanoscopic sensors in picoliter volumes (e.g. single cells, but also microcompartments and aerosols). For quantitative ND-NV- sensing of paramagnetic analytes in such contexts, however, there remains an incomplete understanding of how factors related to the aqueous phase environment control detection efficiency. To address this, optically detected magnetic resonance (ODMR) is measured in bulk macroscale solutions and single levitated microdroplets as a function of Gd+3 concentration (340 nM to 1.5 mM), nanodiamond size, pH, competitor ions, and ligands. The ODMR response to [Gd+3] is found to be nonlinear, and pH, ND and sample volume dependent; indicating the detection of Gd+3 requires efficient adsorption of the analyte to the diamond surface. Langmuir adsorption isotherms embedded in a quantitative photophysical model links the ODMR response to adsorption thermodynamics of Gd+3. The equilibrium constant for Gd+3 adsorption to a carboxylated ND surface is determined to be (1 ± 0.5) x 105 M-1 corresponding to a free energy of adsorption of (-28 ± 1) kJ mol-1. These results provide general insight into how complex aqueous and microscale environments impact nanodiamond based quantum sensing modalities, and portend their application as quantitative chemical sensors in microenvironments.

Brown, Emily K↗