Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Characterization of Structural and Pigmentary Colors in Common Emigrant (Catopsilia Pomona) Butterfly

Study of structural colors in case of insects and butterflies is important for their biomimic and biophotonics applications. Structural color is the color which is produced by physical structures and their interaction with light while pigmentary color is produced by absorption of light by pigments. Common Emigrant butterfly is widely distributed in India. It is of moderate size with wing span of about 60-80 mm. The wings are broadly white with yellow or sulphur yellow coloration at places as well as few dark black patches. It belongs to family Pieridae. A study of structural color in case of Common Emigrant butterfly has been carried out in the present work. The characterization of wing color was performed using absorption spectroscopy. Scanning electron microscopic study of the wings of Common Emigrant butterfly showed that three different types of scales are present on the wing surface dorsally. Diffracting structures are present in certain parts of the surfaces of the various scales. Bead like structures are embedded in the intricate structures of the scales. Absorption spectra revealed that a strong absorption peak is seen in the UV-range. Crystalline structure of beads was confirmed by the X-ray diffraction analysis.

60 APPLIED LIFE SCIENCES↗

Correlation between structural and opto-electronic characteristics of crystalline Si microhole arrays for photonic light management

By employing electron paramagnetic resonance spectroscopy, transmission electron microscopy, and optical measurements, we systematically correlate the structural and optical properties with the deep-level defect characteristics of various tailored periodic Si microhole arrays, which are manufactured in an easily scalable and versatile process on nanoimprinted sol-gel coated glass. While tapered microhole arrays in a structured base layer are characterized by partly nanocrystalline features, poor electronic quality with a defect concentration of 10{sup 17} cm{sup −3} and a high optical sub-band gap absorption, planar polycrystalline Si layers perforated with periodic arrays of tapered microholes are composed of a compact crystalline structure and a defect concentration in the low 10{sup 16} cm{sup −3} regime. The low defect concentration is equivalent to the one in planar state-of-the-art solid phase crystallized Si films and correlates with a low optical sub-band gap absorption. By complementing the experimental characterization with 3-dimensional finite element simulations, we provide the basis for a computer-aided approach for the low-cost fabrication of novel high-quality structures on large areas featuring tailored opto-electronic properties.

36 MATERIALS SCIENCE↗

Investigation of size dependent structural and optical properties of thin films of CdSe quantum dots

Research highlights: {yields} CdSe q-dots have been synthesized using simple chemical synthesis route. {yields} Thin film of CdSe quantum dots exhibited self-organized growth. {yields} Size dependent blue shift observed in the absorption edge of CdSe nanocrystallites. {yields} PL emission band corresponds to band edge luminescence and defect luminescence. {yields} Organized growth led to enhancement in luminescence yield of smaller size Q-dots. -- Abstract: Cadmium selenide (CdSe) quantum dots were grown on indium tin oxide substrate using wet chemical technique for possible application as light emitting devices. The structural, morphological and luminescence properties of the as deposited thin films of CdSe Q-dot have been investigated, using X-ray diffraction, transmission electron microscopy, atomic force microscopy and optical and luminescence spectroscopy. The quantum dots have been shown to deposit in an organized array on ITO/glass substrate. The as grown Q-dots exhibited size dependent blue shift in the absorption edge. The effect of quantum confinement also manifested as a blue shift of photoluminescence emission. It is shown that the nanocrystalline CdSe exhibits intense photoluminescence as compared to the large grained polycrystalline CdSe films.

36 MATERIALS SCIENCE↗

Microstructure Experiments-Enabled MARMOT Simulations of SiC/SiC-based Accident Tolerant Nuclear Fuel System

We have undertaken an experimental-computational project that addresses a few key technology gaps associated with the use of SiC/SiC composites for light water reactor fuel cladding. Two principal endeavors in this project are to assess the irradiation-induced microstructural changes and swelling in SiC/SiC composites, and to characterize and model the porous oxide surface layer (when exposed to steam) along SiC recession that is detrimental to the clad integrity under accident conditions. The project tasks are: (i) ion irradiation and characterization (University of Tennessee, Knoxville), (ii) mechanical tests and analysis (University of South Carolina), (iii) steam exposure tests (Oak Ridge National Laboratory), (iv) electron microscopy and spectroscopic characterization (NC State University), (v) x-ray microscopy and reconstruction (University of South Carolina and NC State University), (vi) phase field modeling and simulations (NC State University and Idaho National Laboratory). The effects of 10 MeV Au ion irradiation at 350°C on the microstructure evolution in SiC/SiC composites are investigated at doses up to 400 displacements per atom (dpa) at the University of Tennessee, Knoxville. Atomic force microscopy and optical profilometry reveal irradiation induced axial and radial shrinkage of the fibers for doses greater than 10 dpa. Based on detailed electron microscopy characterization, the primary cause of the fiber shrinkage is attributed to irradiation-induced loss of carbon packets. Additionally, the multilayer PyC interface is observed to portray high resistance to irradiation damage. The mechanical response and failure mechanisms of un-irradiated samples is also assessed through loading tests and X-ray imaging at the University of South Carolina. Steam exposure tests are performed at the Oak Ridge National Laboratory in a facility that represents a reactor pressure vessel under a loss-of-coolant-accident scenario. The samples that are analyzed methodically in this report are tested for 32/31 hours at 1200°C with a velocity of 0.25 cm/s for the pressures: 0.1 MPa, 0.45 MPa, 0.92 MPa and 1.38 MPa. Scanning/transmission electron microscopy analysis conducted at the NC State University (NCSU) shows that the oxide layer thickness increases with the steam pressure. While the oxide layer is crystalline (α- cristobalite) for the pressures 0.45 MPa, 0.92 MPa and 1.38 MPa, the layer is amorphous at 0.1 MPa. Results from Raman spectroscopy have also confirmed the formation of α-cristobalite phase of SiO₂. The abrupt increase in the integrated Raman intensity ratio between steam pressures 0.1 and 0.45 MPa suggests the onset of accelerated crystallization. Non-destructive three dimensional X-ray microscopy/tomography (XCT) and computational image processing techniques are employed by the University of South Carolina to probe the porous oxidation features on SiC samples at varying pressures. Interestingly, most pores are observed to be located away from the surface as well as the oxide-SiC interface. The average oxide layer thickness assessed from the XCT analysis is seen to be in excellent agreement with the values determined through scanning electron microscopy analysis for the highest pressures where the oxide layer is relatively more uniform. A phase-field model developed by the NC State University and Idaho National Laboratory for simulating oxidation of SiC by steam captures the paralinear kinetics of SiC oxidation with a high degree of fidelity. Results from quasi-one-dimensional and two dimensional simulations show that the pores with oxidizing species lead to a higher volatilization rate. These simulations indicate that the enhanced apparent volatilization rates at higher pressures observed in experiments can be rationalized by the increased volatilization from the pores. The project team has also successfully developed the capability to import images from experiments for realistic evolution of the oxidizing microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Super-resolution microscopy reveals structural diversity in molecular exchange among peptide amphiphile nanofibres

The dynamic behaviour of supramolecular systems is an important dimension of their potential functions. Here, we report on the use of stochastic optical reconstruction microscopy to study the molecular exchange of peptide amphiphile nanofibres, supramolecular systems known to have important biomedical functions. Solutions of nanofibres labelled with different dyes (Cy3 and Cy5) were mixed, and the distribution of dyes inserting into initially single-colour nanofibres was quantified using correlative image analysis. Our observations are consistent with an exchange mechanism involving monomers or small clusters of molecules inserting randomly into a fibre. Different exchange rates are observed within the same fibre, suggesting that local cohesive structures exist on the basis of beta-sheet discontinuous domains. The results reported here show that peptide amphiphile supramolecular systems can be dynamic and that their intermolecular interactions affect exchange patterns. Lastly, this information can be used to generate useful aggregate morphologies for improved biomedical function.

36 MATERIALS SCIENCE↗

Seeing is believing: visualization of antiferromagnetic domains

Abstract Understanding and utilizing novel antiferromagnetic (AFM) materials has been recently one of the central issues in condensed matter physics, as well as in materials science and engineering. The relevant contemporary topics include multiferroicity, topological magnetism and AFM spintronics. The ability to image magnetic domains in AFM materials is of key importance for the success of these exciting fields. While imaging techniques of magnetic domains on the surfaces of ferro-(ferri)magnetic materials with, for example, magneto-optical Kerr microscopy and magnetic force microscopy have been available for a number of decades, AFM domain imaging is a relatively new development. We review various experimental techniques utilizing scanning, optical, and synchrotron X-ray probes to visualize AFM domains and domain walls, and to unveil their physical properties. We also discuss the existing challenges and opportunities in these techniques, especially with further increase of spatial and temporal resolution.

36 MATERIALS SCIENCE↗

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

Unit-density SU(3) Fermi-Hubbard model with spin-flavor imbalance

The advent of ultracold alkaline-earth atoms in optical lattices has established a platform for investigating correlated quantum matter with SU⁡(𝑁) symmetry, offering highly tunable model parameters that allow experiments to access phenomena that are unavailable in conventional materials. Understanding the ground-state physics of SU⁡(𝑁) Fermi-Hubbard models away from the Heisenberg limit and from the spin-flavor balanced setting is important, as examining the flavor imbalance reveals new physics in Fermi-Hubbard models and shows how SU⁡(𝑁) phases react to practical experimental imperfections in optical lattices. Here, in this study, mean-field phase diagrams are presented for the unit-density SU(3) Fermi-Hubbard model at two sets of flavor densities, ($\frac{1}{3}$ − 𝛿, $\frac{1}{3}$ + 𝛿, $\frac{1}{3}$) and ($\frac{1}{4}$ − 𝛿, $\frac{1}{4}$ +𝛿, $\frac{1}{2}$), with the flavor imbalance introduced as 𝛿. Novel phases are identified at moderate interaction strengths for both densities, and their robustness is investigated in the presence of flavor imbalance. Furthermore, we provide microscopic explanations of the phases found and their stability. Analysis of thermal ensembles of random mean-field solutions indicate that, at temperatures accessible in state-of-the-art cold atom experiments, some spin orders are hard for conventional scattering or local observable measurements to detect, but can be more accessible with quantum gas microscopy in optical lattice experiments. This work also shows that nesting and Mottness, intertwined in the usual SU(2) Hubbard model in stark contrast to generic materials, can be tuned in the SU(3) model and play distinct roles. The resulting phase diagrams not only deepen our understanding of SU⁡(𝑁) Fermi-Hubbard models but also inform future experimental search for new phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amorphous Quantum Nanomaterials

In quantum materials macroscopic behavior is governed in non-trivial ways by quantum phenomena. This is usually achieved by exquisite control over atomic positions in crystalline solids. Here we demonstrate that the use of disordered glassy materials provides unique opportunities to tailor quantum material properties. By borrowing ideas from single molecule spectroscopy, we isolate single delocalized π-electron dye systems in relatively rigid ultrasmall (<10nm diameter) amorphous silica nanoparticles. We demonstrate that chemically tuning the local amorphous silica environment around the dye over a range of compositions enables exquisite control over dye quantum behavior, leading to efficient probes for photodynamic therapy (PDT) and stochastic optical reconstruction microscopy (STORM). Results suggest that efficient fine-tuning of light-induced quantum behavior mediated via effects like spin-orbit coupling can be effectively achieved by systematically varying averaged local environments in glassy amorphous materials as opposed to tailoring well-defined neighboring atomic lattice positions in crystalline solids. Finally, resulting nanoprobes have required features proven to enable clinical translation.

36 MATERIALS SCIENCE↗

Electro-chemo-mechanical evolution of sulfide solid electrolyte/Li metal interfaces: operando analysis and ALD interlayer effects

Sulfide solid electrolytes (SE) show promise for high-performance solid-state batteries because of their high ionic conductivity and ease of processing. However, sulfide electrolytes have suffered from chemical and electrochemical instability against Li metal anodes. In this paper, we use a suite of in situ/operando microscopy and spectroscopy techniques to demonstrate that Al 2 O 3 interlayers deposited using atomic layer deposition (ALD) delay degradation at the Li/LGPS interface by modifying the solid electrolyte interphase (SEI) chemistry and morphology. Optical and scanning electron microscopy are used to rationalize the electrochemical response of the system, which is attributed to a delayed onset of mechanical degradation at the interface when ALD interlayers are used. Operando X-ray photoelectron spectroscopy demonstrates that the dynamic evolution of SEI chemistry is impacted by the presence of the ALD interlayer. In situ Auger spectroscopy and operando optical microscopy provide visual evidence of spatial heterogeneity of Li plating, which is attributed to the chemo-mechanical degradation of the ALD interphase. The implications of these observations provide valuable insights toward the development of robust interlayers for solid-state batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm (figures I and 2). The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Using an array of ion-specific electrodes (ISEs), cyclic voltammetry, and electrochemical techniques, the chemistry cells will wet soil samples for measurement of basic soil properties of pH, redox potential, and conductivity. Total dissolved material, as well as targeted ions will be detected to the ppm level, including important exobiological ions such as Na, K+, Ca++, Mg++, NH4+, Cl, S04-, HC03, as well as more toxic ions such as Cu++, Pb++, Cd++, Hg++, and C104-. MECA's microscopy station combines optical and atomic-force microscopy (AFM) to image dust and soil particles from millimeters to nanometers in size. Illumination by red, green, and blue LEDs is augmented by an ultraviolet LED intended to excite fluorescence in the sample. Substrates were chosen to allow experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. To aid in the detection of potentially dangerous quartz dust, an abrasion tool measures sample hardness relative to quartz and a hard glass (Zerodur).

Meloy, Thomas P.↗

Mars Environmental Compatibility Assessment (MECA): Identifying the Hazards of the Martian Soil

Sometime in the next decade NASA will decide whether to send a human expedition to explore the planet Mars. The Mars Environmental Compatibility Assessment (MECA) has been selected by NASA to evaluate the Martian environment for soil and dust hazards to human exploration. The integrated MECA payload contains three elements: a wet-chemistry laboratory, a microscopy station, and enhancements to a lander robot-arm system incorporating arrays of material patches and an electrometer to identify triboelectric charging during soil excavation. The wet-chemistry laboratory will evaluate samples of Martian soil in water to determine the total dissolved solids, redox potential, pH, and quantify the concentration of many soluble ions using ion-selective electrodes. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. MECA's microscopy station combines optical and atomic-force microscopy with a robot-arm camera to provide imaging over nine orders of magnitude, from meters to nanometers. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined on the microscope stage using an ar-ray of sample receptacles and collection substrates, and an abrasion tool,. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Although selected by NASA's Human Exploration and Development of Space Enterprise, the MECA instrument suite also has the capability to address basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogical, petrological, and reactivity of Martian surface materials should be constrained: the NMCA experiment will shed light on these quantities through its combination of chemistry and microscopy. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond.

Meloy, T. P.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Optical interference for the guidance of cryogenic focused ion beam milling beyond the axial diffraction limit

Cryogenic focused ion beam (Cryo-FIB) milling has become a standard step in the cryogenic electron tomography (Cryo-ET) workflow and is required to thin cells to electron-semitransparency. However, this destructive process removes the vast majority of the cellular material and raises a critical question: what thin section should be preserved for Cryo-ET analysis? Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labeled structures with accuracy beyond the diffraction limit. Here we demonstrate this approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of amorphous ice. We then apply the approach to capture virions inside host cells. Successful targeting is confirmed by Cryo-ET revealing clusters of virions in intracellular vesicles. The method does not require any fluorescent fiducials or axial registration and can be performed on any fluorescently labeled structure that is visible in widefield fluorescence microscopy.

Cryoelectron microscopy↗

Preparation and characterization of bifunctional dendrimer modified Fe{sub 3}O{sub 4}/CdTe nanoparticles with both luminescent and superparamagnetic properties

Highlights: • The fluorescent superparamagnetic dendrimeric Fe{sub 3}O{sub 4}/CdTe nanoparticles are synthesized in this paper. • The synthesized nanocomposites maintain excellent magnetic properties. • The synthesized nanocomposites maintain highly luminescent markers with narrow emission bands. - Abstract: Magnetic nanoparticles Fe{sub 3}O{sub 4} were prepared by hydrothermal coprecipitation of ferric and ferrous ions using NaOH. The surface modification of Fe{sub 3}O{sub 4} nanoparticle by dendrimers has rendered the nanoparticle surface with enriched amine groups which facilitated the adsorption and conjugation of thioglycolic acid (TGA) modified CdTe quantum dots to form a stable hybrid nanostructure. Three generations (first generation: G0F, second generation: G1F, third generation: G3F) of bifunctional dendrimeric Fe{sub 3}O{sub 4}/CdTe nanoparticles were successfully prepared using this technique and characterized by microscopy. The optical and magnetic properties of the dendrimeric Fe{sub 3}O{sub 4}/CdTe nanoparticle were also investigated. The microscopic study reveals 3 different sizes for 3 generations, 16 nm (G0F), 31 nm (G1F) and 47 nm (G3F). Among three generations of nanoparticles, the G1F has the best optical property with a luminescent quantum yield of 25.6% and the G0F has the best magnetic property with a saturation magnetization of 19.3 emμ/g.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗