Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Calibration standards and field instruments for the precision measurement of insolation

The paper describes the development of an absolute calibration standard for irradiance measurements. This field instrument, designated the Kendall Radiometer System Mark 3, is identical to the PACRAD (Primary Absolute Cavity Radiometer) except for a modification to ensure all weather operation. Two Mark 3 radiometers have been in operation at the JPL's Goldstone Deep Space Communications Complex for over two years and are continuing to provide data which are within plus or minus 1% of the absolute value. A calibration stability analysis is presented for the two instruments.

Reid, M. S.↗

Maintaining calibration of long term satellite monitoring devices as performed on the ozone sensing BUV instruments

Several potential calibration updating techniques for satellite-borne instruments for monitoring the stratosphere are reviewed. The Nimbus 4 BUV instrument was checked against an Atmosphere Explorer 5 BUV launched in November 1975. The problems encountered in this exercise are discussed and generalized to establish an initial checklist for future calibration experiments of satellite sensors using Shuttle-borne sensors.

Guenther, B.↗

The airborne Laser Absorption Spectrometer - A new instrument of remote measurement of atmospheric trace gases

The Laser Absorption Spectrometer is a portable instrument developed by JPL for remote measurement of trace gases from an aircraft platform. It contains two carbon dioxide lasers, two optical heterodyne receivers, appropriate optics to aim the lasers at the ground and detect the backscattered energy, and signal processing and recording electronics. Operating in the differential-absorption mode, it is possible to monitor one atmospheric gas at a time and record the data in real time. The system can presently measure ozone, ethylene, water vapor, and chlorofluoromethanes with high sensitivity. Airborne measurements were made in early 1977 from the NASA/JPL twin-engine Beechcraft and in May 1977 from the NASA Convair 990 during the ASSESS-II Shuttle Simulation Study. These flights resulted in measurements of ozone concentrations in the lower troposphere which were compared with ground-based values provided by the Air Pollution Control District. This paper describes the details of the instrument and results of the airborne measurements.

Shumate, M. S.↗

Ultraviolet astronomy instrumentation for sounding rocket and Shuttle/Spacelab missions

The paper deals with an electrographic Schmidt camera for wide-field imaging and objective-spectrographic sky surveys, and with a nebula spectrograph designed to obtain slit spectra of nebulae and other diffuse sources. Each of these ultraviolet astronomy instruments has been successfully used in sounding rocket flights. It is seen that, with some minor modifications, both instruments should be readily adaptable to Spacelab missions.

Carruthers, G. R.↗

Measurement of the polarization effects of an instrument using partially polarized light

Accuracy of a radiometer is adversely affected by scene polarization if the receiving optical system is sensitive to polarization. It is therefore necessary to specify and measure the sensitivity of the system to polarized light. The Mueller-Stokes matrix of an instrument may be determined experimentally and used to predict the effects of the instrument on any beam. The specification of a maximum polarization sensitivity stated in terms of the degree of polarization produced in an unpolarized beam can be experimentally verified even though an unpolarized beam is not available in the laboratory for direct measurement.

Howell, B. J.↗

A flexible CAMAC based data system for Space Shuttle scientific instruments

An effort has been made within NASA to produce a low-cost modular system for implementation of Shuttle payloads based on the CAMAC standards for packaging and data transfer. A key element of such a modular system is a means for controlling the data system, collecting and processing the data for transmission to the ground, and issuing commands to the instrument either from the ground or based on the data collected. A description is presented of such a means based on a network of digital processors and CAMAC crate controllers, which allows for the implementation of instruments ranging from those requiring only a single CAMAC crate of functional modules and no data processing to ones requiring multiple crates and multiple data processors.

Ehrmann, C. H.↗

Correction of instrumental distortion by analytical deconvolution of data

A general analytical theorem developed by van de Hulst (1946) for inverting the convolution integral is reviewed and illustrated both with synthetic data and with experimental data from time-of-flight measurements. If the undesired influence of an instrument used in an experimental measurement can be represented by the convolution integral, the original undistorted or true distribution may sometimes be recovered in postprocessing the data by means of deconvolution. Analytical deconvolution is achieved by using the coefficients from a power series representation of the distorted output distribution and a set of 'solving polynomials' which may be readily derived from the response function of the instrument.

Morton, D. C.↗

Single pilot scanning behavior in simulated instrument flight

A simulation of tasks associated with single pilot general aviation flight under instrument flight rules was conducted as a baseline for future research studies on advanced flight controls and avionics. The tasks, ranging from simple climbs and turns to an instrument landing systems approach, were flown on a fixed base simulator. During the simulation the control inputs, state variables, and the pilots visual scan pattern including point of regard were measured and recorded.

Pennington, J. E.↗

Analysis of Lunar Seismic Signals: Determination of Instrumental Parameters and Seismic Velocity Distributions

Inverse filters were designed to correct the effect of instrumental response, coupling of the seismometer to the ground, and near surface structures. The least squares technique was used to determine the instrumental constants and the transfer functions of the long period lunar seismographs. The influence of noise and the results of these calculations are discussed.

Horvath, P.↗

Preliminary investigation of pilot scanning techniques of dial pointing instruments

Two pilots' methods of looking at instruments with needle pointers in a fixed base helicopter simulation were observed. A total of 45 runs were analyzed for each pilot. The data indicated that two apparently different techniques were being used; one looking at the needle point, the other looking at a fixed spot on the instrument and reading the needle direction parafoveally. The latter technique is found to be somewhat faster with both pilots accomplishing the flying task.

Harris, R. L., Sr.↗

Impact of new instrumentation on advanced turbine research

A description is presented of an orderly test program that progresses from the simplest stationary geometry to the more complex, three dimensional, rotating turbine stage. The instrumentation requirements for this evolution of testing are described. The heat transfer instrumentation is emphasized. Recent progress made in devising new measurement techniques has greatly improved the development and confirmation of more accurate analytical methods for the prediction of turbine performance and heat transfer. However, there remain challenging requirements for novel measurement techniques that could advance the future research to be done in rotating blade rows of turbomachines.

Graham, R. W.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Those aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described with emphasis on the instrumentation and data acquisition system used in the Langley 0.3 m transonic cryogenic tunnel. Typical calibration results obtained in a 20 by 60 cm two dimensional test section are included.

Ladson, C. L.↗

The High Visible Resolution (HVR) instrument of the spot ground observation satellite

Two identical high resolution cameras, capable of attaining a track width of 116 km in an almost vertical line of sight from the two 60 km images of each instrument, will be carried on the initial mission of the space observation of Earth satellite (SPOT). Specifications for the instrument, including the telescope and CCD devices are summarized. The present status of development is described including the optical characteristics, structure and thermal control, detector assembly, electronic equipment, and calibration. SPOT mission objectives include the developments relating to soil use, the exploration of EART Earth resources, the discrimination of plant species, and cartography.

Otrio, G.↗

A pilot's assessment of helicopter handling-quality factors common to both agility and instrument flying tasks

A series of simulation and flight investigations were undertaken to evaluate helicopter flying qualities and the effects of control system augmentation for nap-of-the-Earth (NOE) agility and instrument flying tasks. Handling quality factors common to both tasks were identified. Precise attitude control was determined to be a key requirement for successful accomplishment of both tasks. Factors that degraded attitude controllability were improper levels of control sensitivity and damping, and rotor system cross coupling due to helicopter angular rate and collective pitch input. Application of rate command, attitude command, and control input decouple augmentation schemes enhanced attitude control and significantly improved handling qualities for both tasks. The NOE agility and instrument flying handling quality considerations, pilot rating philosophy, and supplemental flight evaluations are also discussed.

Gerdes, R. M.↗

Atmospheric lidar multi-user instrument system definition study

A spaceborne lidar system for atmospheric studies was defined. The primary input was the Science Objectives Experiment Description and Evolutionary Flow Document. The first task of the study was to perform an experiment evolutionary analysis of the SEED. The second task was the system definition effort of the instrument system. The third task was the generation of a program plan for the hardware phase. The fourth task was the supporting studies which included a Shuttle deficiency analysis, a preliminary safety hazard analysis, the identification of long lead items, and development studies required. As a result of the study an evolutionary Lidar Multi-User Instrument System (MUIS) was defined. The MUIS occupies a full Spacelab pallet and has a weight of 1300 kg. The Lidar MUIS laser provides a 2 joule frequency doubled Nd:YAG laser that can also pump a tuneable dye laser wide frequency range and bandwidth. The MUIS includes a 1.25 meter diameter aperture Cassegrain receiver, with a moveable secondary mirror to provide precise alignment with the laser. The receiver can transmit the return signal to three single and multiple photomultiple tube detectors by use of a rotating fold mirror. It is concluded that the Lidar MUIS proceed to program implementation.

Greco, R. V.↗

Infrared radiometer for the Pioneer Venus orbiter. I - Instrument description

A ten-channel IR radiometer for the Pioneer Venus orbiter is described. The experimental techniques used and the design of the instrumentation by which they were implemented are considered. Emphasis is placed on temperature sounding, limb sounding, limb darkening, zenith scanning, cloud top temperature, spectral albedo and water vapor measurements. Instrumentation description is also given including optics, detectors, and electronics. Attention is given to data acquisition and handling, calibration, and in-flight performance.

Taylor, F. W.↗

Space telescope scientific instruments

The paper describes the Space Telescope (ST) observatory, the design concepts of the five scientific instruments which will conduct the initial observatory observations, and summarizes their astronomical capabilities. The instruments are the wide-field and planetary camera (WFPC) which will receive the highest quality images, the faint-object camera (FOC) which will penetrate to the faintest limiting magnitudes and achieve the finest angular resolution possible, and the faint-object spectrograph (FOS), which will perform photon noise-limited spectroscopy and spectropolarimetry on objects substantially fainter than those accessible to ground-based spectrographs. In addition, the high resolution spectrograph (HRS) will provide higher spectral resolution with greater photometric accuracy than previously possible in ultraviolet astronomical spectroscopy, and the high-speed photometer will achieve precise time-resolved photometric observations of rapidly varying astronomical sources on short time scales.

Leckrone, D. S.↗

Solar rotation measurements at Mount Wilson. I - Analysis and instrumental effects

We examine the background velocity fields of the sun as observed at Mount Wilson. The method of velocity reduction of the full-disk Mount Wilson data is outlined. We describe a number of tests that have been carried out in order to find an instrumental origin for short-term rotation variations and a large-scale background line-shift - the ears. No instrumental cause can be found for this ear effect, although such a cause cannot yet be ruled out.

Howard, R.↗