Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear level density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Incompressibility of neutron-rich matter

The saturation properties of neutron-rich matter are investigated in a relativistic mean-field formalism using two accurately calibrated models: NL3 and FSUGold. The saturation properties--density, binding energy per nucleon, and incompressibility coefficient--are calculated as a function of the neutron-proton asymmetry {alpha}{identical_to}(N-Z)/A to all orders in {alpha}. Good agreement (at the 10% level or better) is found between these numerical calculations and analytic expansions that are given in terms of a handful of bulk parameters determined at saturation density. Using insights developed from the analytic approach and a general expression for the incompressibility coefficient of infinite neutron-rich matter, i.e., K{sub 0}({alpha})=K{sub 0}+K{sub {tau}}{alpha}{sup 2}+..., we construct a hybrid model with values for K{sub 0} and K{sub {tau}} as suggested by recent experimental findings. Whereas the hybrid model provides a better description of the measured distribution of isoscalar monopole strength in the Sn isotopes relative to both NL3 and FSUGold, it significantly underestimates the distribution of strength in {sup 208}Pb. Thus, we conclude that the incompressibility coefficient of neutron-rich matter remains an important open problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical Advice and Support for the Joint Integrated Non-Intrusive Inspection (JINII) Program Task 2.2 Transmission Digital Radiography (DR)

The Cargo Advanced Automated Radiography System (CAARS) program aims to utilize advanced radiographic systems to detect radiological and nuclear threats. Validation of initial design and testing concepts is a precondition for prototype system development and large-scale deployment. As expected, Depleted Uranium (DU) is a valid surrogate for Special Nuclear Materials (SNM) in CAARS Advanced Technology Demonstration (ATD) performance field-tests of transmission radiography systems. Dual-energy transmission measurements of DU are nearly identical to SNM, and are distinct from lower Z materials, provided the samples are matched to equal areal density. Results from an alternative method, using samples of equal thickness, showed sample discrimination by material density, rather than by atomic number (Z). The transmission measurements of DU and SNM were made with equipment that is nearly identical to current field systems. X-ray source beams at endpoint energies of 5.4 MeV and 9.6 MeV were used to measure transmission through the selected sample materials. The ratio of the x-ray linear attenuation coefficient times length ({micro}L) at 5.4 MeV, to {micro}L at 9.6 MeV is a metric for atomic number based discrimination of materials. The measured ratios were compared with computed values based on LLNL photon cross section data and LLNL developed models of x-ray detector characteristics. Measured ratios for DU differed from HEU by an average of 0.25%, and from WGPu by 0.08%, which is within the noise level of 0.4 to 0.5%. For comparison, measured ratios for Sn differed from HEU by 3.2%, and from WGPu by 3.6%, well beyond the measurement noise. Measured ratios for W differed from HEU by 0.01%, and from WGPu by 0.32%. The measured ratio values presented in Table 1 demonstrate the feasibility of using a threshold ratio to discriminate low-Z (Z < 72) from high-Z (Z {ge} 72) materials (as defined by CAARS specification). In the case of our test system, a threshold ratio of 1.08 would be suitable based on the measured results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

4 kW Test of Solid Oxide Electrolysis Stacks with Advanced Electrode-Supported Cells

A new test stand has been developed at the Idaho National Laboratory for multi-kW testing of solid oxide electrolysis stacks. This test stand will initially be operated at the 4 KW scale. The 4 kW tests will include two 60-cell stacks operating in parallel in a single hot zone. The stacks are internally manifolded with an inverted-U flow pattern and an active area of 100 cm2 per cell. Process gases to and from the two stacks are distributed from common inlet/outlet tubing using a custom base manifold unit that also serves as the bottom current collector plate. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. Treated metallic interconnects with integral flow channels separate the cells and electrode gases. Sealing is accomplished with compliant mica-glass seals. A spring-loaded test fixture is used for mechanical stack compression. Due to the power level and the large number of cells in the hot zone, process gas flow rates are high and heat recuperation is required to preheat the cold inlet gases upstream of the furnace. Heat recuperation is achieved by means of two inconel tube-in-tube counter-flow heat exchangers. A current density of 0.3 A/cm2 will be used for these tests, resulting in a hydrogen production rate of 25 NL/min. Inlet steam flow rates will be set to achieve a steam utilization value of 50%. The 4 kW test will be performed for a minimum duration of 1000 hours in order to document the long-term durability of the stacks. Details of the test apparatus and initial results will be provided.

08 HYDROGEN↗

The Decontamination, Decommissioning, and Demolition of the Engineering Test Reactor at the Idaho Cleanup Project

In September 2007, CH2M-WG Idaho completed the decontamination, decommissioning and demolition (D and D) of the Engineering Test Reactor (ETR) facility. The 50-year-old research reactor, located at the Idaho National Laboratory site, posed significant challenges involving regulations governing the demolition of a historical facility, the removal of a large amount of hazardous materials as well as issues associated with the removal and disposal of the 112-ton reactor vessel. Prior to commencing full scale D and D, hazardous constituents were removed including cadmium, PCB oils and electrical components, lead, asbestos and mercury among others. The reactor required isolation in order to be removed. Due to activated metal within the reactor vessel, dose rates in the core region were approximately 1100 R/hr. Subsequent dose rates outside the vessel varied from 60 mR to greater than 2 R. Due to the dose rates, the project team decided to fill the reactor vessel with grout to a level above the core region and below the discharge to the canal. To remove the reactor, access to the 17 mounting shoes was required. These shoes were encased in the high density concrete biological shield approximately 8 feet below grade. The project team used explosives to remove the biological shield. The demolition had to be controlled to prevent damaging the reactor vessel and to limit the seismic impact on a nearby operating reactor. Upon completion of the blast, the concrete was removed exposing the support shoes for the vessel. The reactor building was then demolished to accommodate the twin gantry system used to lift the reactor vessel. In September, the reactor vessel was lifted and placed onto a multi-axle trailer for transport to an onsite disposal facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observations and Lessons Learned from Testing of the Hanford Waste Treatment Plant Standard High Solids Vessel Design - 18635

The Hanford Waste Treatment and Immobilization Plant (WTP) recently completed qualification testing of the mixing system for the standard high solids vessel design the U.S. Department of Energy (DOE) proposed to replace several vessels in the design of the plant Pretreatment Facility. Testing was split into two phases. The first phase exercised the pulse jet mixer control system to ensure that the control software could accommodate fluids across the complete range of expected densities and viscosities within the vessel for all operational modes. The second phase of testing was focused on the mixing performance of the vessel, specifically, whether mixing was adequate to support the transfer, de-inventory, throughput, and sampling functions of the vessel. Key observations and lessons learned from testing include: - Successful transfer of waste within and beyond the design basis slurry solids concentration; - Successful resuspension and transfer of large, heavy particles; - Effective performance of multi-level bubblers for process control and monitoring; - Effective controls performance; - Reduction of sparger flowrate from nominal design flow; - Liquid blending within about 15 minutes; - Insights into sample representativeness and uniformity of transfers to inform process control strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of 4-Dimensional Computed Tomography Ventilation With Nuclear Medicine Ventilation-Perfusion Imaging: A Clinical Validation Study

Purpose: Four-dimensional computed tomography (4DCT) ventilation imaging provides lung function information for lung cancer patients undergoing radiation therapy. Before 4DCT-ventilation can be implemented clinically it needs to be validated against an established imaging modality. The purpose of this work was to compare 4DCT-ventilation to nuclear medicine ventilation, using clinically relevant global metrics and radiologist observations. Methods and Materials: Fifteen lung cancer patients with 16 sets of 4DCT and nuclear medicine ventilation-perfusion (VQ) images were used for the study. The VQ-ventilation images were acquired in planar mode using Tc-99m-labeled diethylenetriamine-pentaacetic acid aerosol inhalation. 4DCT data, spatial registration, and a density-change-based model were used to compute a 4DCT-based ventilation map for each patient. The percent ventilation was calculated in each lung and each lung third for both the 4DCT and VQ-ventilation scans. A nuclear medicine radiologist assessed the VQ and 4DCT scans for the presence of ventilation defects. The VQ and 4DCT-based images were compared using regional percent ventilation and radiologist clinical observations. Results: Individual patient examples demonstrate good qualitative agreement between the 4DCT and VQ-ventilation scans. The correlation coefficients were 0.68 and 0.45, using the percent ventilation in each individual lung and lung third, respectively. Using radiologist-noted presence of ventilation defects and receiver operating characteristic analysis, the sensitivity, specificity, and accuracy of the 4DCT-ventilation were 90%, 64%, and 81%, respectively. Conclusions: The current work compared 4DCT with VQ-based ventilation using clinically relevant global metrics and radiologist observations. We found good agreement between the radiologist's assessment of the 4DCT and VQ-ventilation images as well as the percent ventilation in each lung. The agreement lessened when the data were analyzed on a regional level. Our study presents an important step for the integration of 4DCT-ventilation into thoracic clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray crystal spectrometer for opacity measurements in the 8-18 A spectral range at the LULI laser facility

An x-ray crystal spectrometer was built in order to measure opacities in the 8-18 A spectral range with an average spectral resolution of <{lambda}/{delta}{lambda}>{approx}400. It has been successfully used at the LULI-2000 laser facility (See C. Sauteret, rapport LULI 2001, 88 (2002) at Ecole Polytechnique (France) to measure in the same experimental conditions the 2p-3d transitions of several elements with the neighboring atomic number Z: Fe, Ni, Cu, and Ge [G. Loisel et al., High Energy Density Phys. 5, 173 (2009)]. Hence, a spectrometer with a wide spectral range is needed. This spectrometer features two lines of sight. In this example, one line of sight looks through the sample and the other one is looking directly at the backlighter emission. Both are outfitted with a spherical condensing mirror. A TlAP crystal is used for spectral dispersion. Detection is made with an image plate Fuji BAS TR2025, which is sensitive to x rays. We present some experimental results showing the performances of this spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE EFFECTS OF THERMONUCLEAR REACTION RATE VARIATIONS ON {sup 26}Al PRODUCTION IN MASSIVE STARS: A SENSITIVITY STUDY

We investigate the effects of thermonuclear reaction rate variations on {sup 26}Al production in massive stars. The dominant production sites in such events were recently investigated by using stellar model calculations: explosive neon-carbon burning, convective shell carbon burning, and convective core hydrogen burning. Post-processing nucleosynthesis calculations are performed for each of these sites by adopting temperature-density-time profiles from recent stellar evolution models. For each profile, we individually multiplied the rates of all relevant reactions by factors of 10, 2, 0.5, and 0.1, and analyzed the resulting abundance changes of {sup 26}Al. In total, we performed {approx}900 nuclear reaction network calculations. Our simulations are based on a next-generation nuclear physics library, called STARLIB, which contains a recent evaluation of Monte Carlo reaction rates. Particular attention is paid to quantifying the rate uncertainties of those reactions that most sensitively influence {sup 26}Al production. For stellar modelers our results indicate to what degree predictions of {sup 26}Al nucleosynthesis depend on currently uncertain nuclear physics input, while for nuclear experimentalists our results represent a guide for future measurements. We also investigate equilibration effects of {sup 26}Al. In all previous massive star investigations, either a single species or two species of {sup 26}Al were taken into account, depending on whether thermal equilibrium was achieved or not. These are two extreme assumptions, and in a hot stellar plasma the ground and isomeric states may communicate via {gamma}-ray transitions involving higher-lying {sup 26}Al levels. We tabulate the results of our reaction rate sensitivity study for each of the three distinct massive star sites referred to above. It is found that several current reaction rate uncertainties influence the production of {sup 26}Al. Particularly important reactions are {sup 26}Al(n,p){sup 26}Mg, {sup 25}Mg({alpha},n){sup 28}Si, {sup 24}Mg(n,{gamma}){sup 25}Mg, and {sup 23}Na({alpha},p){sup 26}Mg. These reactions should be prime targets for future measurements. Overall, we estimate that the nuclear physics uncertainty of the {sup 26}Al yield predicted by the massive star models explored here amounts to about a factor of three. We also find that taking the equilibration of {sup 26}Al levels explicitly into account in any of the massive star sites investigated here has only minor effects on the predicted {sup 26}Al yields. Furthermore, we provide for the interested reader detailed comments regarding the current status of certain reactions, including {sup 12}C({sup 12}C,n){sup 23}Mg, {sup 23}Na({alpha},p){sup 26}Mg, {sup 25}Mg({alpha},n){sup 28}Si, {sup 26}Al {sup m}(p,{gamma}){sup 27}Si, {sup 26}Al(n,p){sup 26}Mg, and {sup 26}Al(n,{alpha}){sup 23}Na.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploration of the Equilibrium Operating Space For NSTX-Upgrade

This paper explores a range of high-performance equilibrium scenarios available in the NSTX-Upgrade device [J.E. Menard, submitted for publication to Nuclear Fusion]. NSTX-Upgrade is a substantial upgrade to the existing NSTX device [M. Ono, et al., Nuclear Fusion 40, 557 (2000)], with significantly higher toroidal field and solenoid capabilities, and three additional neutral beam sources with significantly larger current drive efficiency. Equilibria are computed with freeboundary TRANSP, allowing a self consistent calculation of the non-inductive current drive sources, the plasma equilibrium, and poloidal field coil current, using the realistic device geometry. The thermal profiles are taken from a variety of existing NSTX discharges, and different assumptions for the thermal confinement scalings are utilized. The no-wall and idealwall n=1 stability limits are computed with the DCON code. The central and minimum safety factors are quite sensitive to many parameters: they generally increases with large outer plasmawall gaps and higher density, but can have either trend with the confinement enhancement factor. In scenarios with strong central beam current drive, the inclusion of non-classical fast ion diffusion raises q min , decreases the pressure peaking, and generally improves the global stability, at the expense of a reduction in the non-inductive current drive fraction; cases with less beam current drive are largely insensitive to additional fast ion diffusion. The non-inductive current level is quite sensitive to the underlying confinement and profile assumptions. For instance, for B T =1.0 T and P inj =12.6 MW, the non-inductive current level varies from 875 kA with ITER-98y,2 thermal confinement scaling and narrow thermal profiles to 1325 kA for an ST specific scaling expression and broad profiles. This sensitivity should facilitate the determination of the correct scaling of transport with current and field to use for future fully non-inductive ST devices. Scenarios are presented which can be sustained for 8-10 seconds, or (20-30)τ CR , at β N =3.8-4.5, facilitating, for instance, the study of disruption avoidance for very long pulse. Scenarios have been documented which can operate with β T ~25% and equilibrated q min >1. The value of q min can be controlled at either fixed non-inductive fraction of 100% or fixed plasma current, by varying which beam sources are used, opening the possibility for feedback q min control. In terms of quantities like collisionality, neutron emission, non-inductive fraction, or stored energy, these scenarios represent a significant performance extension compared to NSTX and other present spherical torii.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AFIP6-MkII and RERTR-12 Porosity Data Collection and Analysis for Modeling and Simulation

Gathering data for the improvement of nuclear fuel modeling and simulation efforts is the primary driver for this work. Mechanistic models allow for a better understanding of the material on a micro- and macrostructural level while saving time and money over traditional experiment efforts. Historically, summarized data and correlations are the inputs for empirical material models and model validation. When improving these models for nuclear fuels with experimental results, there is a lack of reliable data readily available. Experiments - RERTR-12 and AFIP6-MkII - were conducted to understand the irradiation behavior of metallic U-10Mo monolithic fuels for use in extreme reactor environments such as research reactors like the Advanced Test Reactor (ATR) or the High Flux Isotope Reactor (HFIR). Microstructural characteristics of fission gas pores (FGP) in each experiment are collected using an automated image analysis technique developed at the University of Florida and presented here. A series of statistical tests are performed to explore the reliability of the results, as well as understand where the data is lacking and what future data collection is necessary to provide sufficient information to assist modeling efforts. The focus is on the porosity, pore size, and eccentricity of FGPs formed during irradiation in three AFIP6-MkII samples and one RERTR-12 sample. From the analysis, it is clear there are substantial impacts of fission density on the pore structure, but there also exist also underlying connections between each sample and the behavior observed in the pores. Further analyses of the pre- and post-irradiation microstructure are needed to improve the understanding of these connections. An early method for microstructural data analysis is presented within and is currently being expanded to include other microstructure data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strong evidence that the galactic bulge is shining in gamma rays

There is growing evidence that the Galactic Center Excess identified in the Fermi-LAT gamma-ray data arises from a population of faint astrophysical sources. We provide compelling supporting evidence by showing that the morphology of the excess traces the stellar over-density of the Galactic bulge. By adopting a template of the bulge stars obtained from a triaxial 3D fit to the diffuse near-infrared emission, we show that it is detected at high significance. The significance deteriorates when either the position or the orientation of the template is artificially shifted, supporting the correlation of the gamma-ray data with the Galactic bulge. In deriving these results, we have used more sophisticated templates at low-latitudes for the Fermi bubbles compared to previous work and the three-dimensional Inverse Compton (IC) maps recently released by the GALPROP team. Our results provide strong constraints on Millisecond Pulsar (MSP) formation scenarios proposed to explain the excess. We find that an admixture formation scenario, in which some of the relevant binaries are primordial and the rest are formed dynamically, is preferred over a primordial-only formation scenario at 7.6σ confidence level. Our detailed morphological analysis also disfavors models of the disrupted globular clusters scenario that predict a spherically symmetric distribution of MSPs in the Galactic bulge. For the first time, we report evidence of a high energy tail in the nuclear bulge spectrum that could be the result of IC emission from electrons and positrons injected by a population of MSPs and star formation activity from the same site.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of In-Can Melting Process Applied to Vitrification of High Activity Waste Solutions (HAWS): Glass characterizations and process tests results - 12442

The CEA has selected vitrification for specific High-Activity nuclear Waste Solutions (HAWS) containing large quantities of salts. This choice has led the CEA Marcoule to develop a compact 'in-can' batch melting process in which the melting pot is disposable and serves as the primary canister for the solidified glass. This process is particularly suitable for the treatment of small waste quantities (less than 10 m{sup 3} per year) and low flow rates (5 to 10 L/h) which do not justify the use of a Cold Crucible Induction Melter. The unit capacity is approximately one hundred kilograms of glass a week operating alternately between feeding during the day and surveillance at night. In order to be fully representative of the glove box to be implemented, a new nonradioactive pilot-scale unit in which the core process (furnace and dust scrubber) is completely enclosed with glove box simulation was built at CEA Marcoule in 2008. The equipment includes all the systems and components necessary to perform full-scale tests: feed system, furnace and complete off-gas treatment system. The nominal tests were performed in 2009 and 2010 to verify that no problems arose in vitrifying solutions under the specified conditions. Two different liquid feeds representatives of the current HAWS stored and future solutions were used. The transient runs were carried out in this facility in 2010. Their objectives were to validate the glass product with different operating conditions and to determine optimum parameters for transient phases such as decreased volatility during standby phases. Finally, all the material obtained under nominal conditions or different operating conditions (e.g. initial glass frit quantity, standby temperature or restart procedure of feeding after night surveillance) have been characterized and described. The impact of transient phases on the process is then discussed in terms of volatility, thermal balance, etc., and compared with nominal tests results. Off-gas treatment system (OGTS) assessments determined preliminary decontamination factors for the OGTS components and allowed comparison between the two types of solutions and for different operating parameters. Since 2005 CEA Marcoule has been developing an 'in-can melting' vitrification process for specific High Activity Nuclear Waste Solutions. The tests carried out to date have validated the feasibility of this process and confirmed the direct vitrification option in which the liquid and solid feed streams are supplied directly to a disposable melting pot. CEA Marcoule began process qualification testing in 2009 in a new facility using equipment representative of the devices that will be installed in a glove box. The nominal mode tests performed in 2009 and 2010 were used to determine nominal operating conditions for the process: - a nominal process temperature of 1100 deg. C; - a maximum glass production rate of 5 kg/h; - a liquid feed solution flow rate of 5 L/h or less if the glass production rate exceeds the preceding maximum value; - a liquid recycle rate of 0.5 L/h for a nominal solution feed rate 5 L/h. They also produced glass samples generally meeting our expectations, and allowed us to measure the characteristic properties (viscosity, density, thermal conductivity, chemical durability). The first test of transient operation in 2010 yielded glass consistent with expectations and showed that reducing the temperature had no significant effect on the volatility of the constituent elements. However, a significant impact on the release of elements at the beginning of the test was observed with a larger initial quantity of glass frit on startup. The process qualification program will now continue with tests of degraded operating modes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding of a Novel Irradiation-induced Nanostructuring Process in SiC layer of TRISO fuel particles via Transmission Electron Microscopy

Metallic fission products are found to transport through the SiC layer of the tristructural isotropic (TRISO) nuclear fuel particle and various studies have been undertaken to understand the transport behavior [1, 2]. While the grain boundaries in SiC acts as a primary pathway to dissipate fission products in the form of multi-phased complex compounds, intragranular fission product precipitation has always been observed. Research on neutron irradiation damage tolerance of silicon carbide (SiC) and its composites, used in TRISO fuel, light water reactors (LWR) fuel cladding etc., has traditionally ignored the irradiation-induced “polymorphism” of SiC. In the post-irradiation advanced microscopy effort at Idaho National Laboratory, it has been recently discovered that the intragranular precipitation of fission products in SiC layer of TRISO coated fuels takes place via a dual step nucleation mechanism that involves cubic (?) ?hexagonal (?) SiC polymorphic transition, and subsequent metamorphosis of ?-SiC into fission product precipitates, as shown in Figure 1 [3]. This precipitation behavior cannot be explained by any reported nucleation mechanism. The extent of this precipitation has been observed to be influenced by the nature of the neutron irradiation induced damage structures. These damage structures (e.g., defect morphology and density) are also indicative of the irradiation temperature and neutron fluence levels experimented by the individual TRISO particles. The distinction of neutron irradiation damage structures as a function of the fuel kernel type, burn up level and fabrication histories of TRISO coated particles from the Advanced Gas reactor (AGR-1 and AGR-2) experiments has been examined and compared. This discovery not only adds new fundamental understanding of physical behavior of polymorphic ceramics under irradiation, but also provides the following beneficial traits for high temperature applications. 1) Since the extent of precipitation of the desired phase is directly dependent on the amount of precursor phase, the volume fraction of desired phase can be easily controlled by irradiation parameters. This eliminates the conventional limitation of volume fraction of a desired phase in the system as outlined by the phase diagram of the specific system. 2) Most of the precipitate-strengthened materials for high temperature applications suffer from degradation of size and shape of precipitate upon prolonged thermal exposures. But, precipitates are confined to the shape and size of the morphological template of surrogate phase (e.g. a Pd silicide precipitate is confined by the ?-SiC as shown in Figure 1(c)) in the present nucleation pathway. Hence, there is no possibility of desired phase to undergo any morphological degradation at high temperature that eventually will extend the lifetime of these materials at high temperature.

42 ENGINEERING↗

Transitions in eigenvalue and wavefunction structure in (1+2)-body random matrix ensembles with spin

Finite interacting Fermi systems with a mean-field and a chaos generating two-body interaction are modeled by one plus two-body embedded Gaussian orthogonal ensemble of random matrices with spin degree of freedom [called EGOE(1+2)-s]. Numerical calculations are used to demonstrate that, as lambda, the strength of the interaction (measured in the units of the average spacing of the single-particle levels defining the mean-field), increases, generically there is Poisson to GOE transition in level fluctuations, Breit-Wigner to Gaussian transition in strength functions (also called local density of states) and also a duality region where information entropy will be the same in both the mean-field and interaction defined basis. Spin dependence of the transition points lambda{sub c}, lambda{sub F}, and lambda{sub d}, respectively, is described using the propagator for the spectral variances and the formula for the propagator is derived. We further establish that the duality region corresponds to a region of thermalization. For this purpose we compared the single-particle entropy defined by the occupancies of the single-particle orbitals with thermodynamic entropy and information entropy for various lambda values and they are very close to each other at lambda=lambda{sub d}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of a Polariton Condensate in Micropillars in a High Magnetic Field

The photoluminescence of a nonequilibrium polariton condensate in cylindrical and rectangular micropillars etched on the surface of a high-Q GaAs microcavity is investigated in magnetic fields of up to 12 T. The measurements are carried out under different levels of nonresonant optical pumping with nanosecond laser pulses for a wide range of cavity detuning. As far as nonresonant excitation produces a high density of excitons in a reservoir, it should be expected that the exciton–polariton interaction, which depends on the pump level, has a considerable effect on the Zeeman splitting and polarization of the condensate. However, measurements of the Zeeman splitting and polarization in high magnetic fields demonstrate that only minor changes take place up to the highest available pump levels. This means that, in the case under study, the effect of exciton–polariton interaction on the polariton system is insignificant. At the same time, the data obtained provide an estimate for the exciton density in the reservoir. In contrast to cylindrical micropillars, the photoluminescence of the condensate in rectangular micropillars consists of two perpendicularly linearly polarized lines which retain a high degree of linear polarization even in a field as high as 12 T. The Zeeman splitting in this case is nearly independent of the pump power. The degrees of both circular and linear polarization change with pump power, but these changes are noticeably smaller than the ones predicted theoretically. This indicates that the system of polaritons in micropillars deviates considerably from thermodynamic equilibrium.

36 MATERIALS SCIENCE↗

Special Application Thermoelectric Micro Isotope Power Sources

Promising design concepts for milliwatt (mW) size micro isotope power sources (MIPS) are being sought for use in various space and terrestrial applications, including a multitude of future NASA scientific missions and a range of military applications. To date, the radioisotope power sources (RPS) used on various space and terrestrial programs have provided power levels ranging from one-half to several hundred watts. In recent years, the increased use of smaller spacecraft and planned new scientific space missions by NASA, special terrestrial and military applications suggest the need for lower power, including mW level, radioisotope power sources. These power sources have the potential to enable such applications as long-lived meteorological or seismological stations distributed across planetary surfaces, surface probes, deep space micro-spacecraft and sub-satellites, terrestrial sensors, transmitters, and micro-electromechanical systems. The power requirements are in the range of 1 mW to several hundred mW. The primary technical requirements for space applications are long life, high reliability, high specific power, and high power density, and those for some special military uses are very high power density, specific power, reliability, low radiological induced degradation, and very low radiation leakage. Thermoelectric conversion is of particular interest because of its technological maturity and proven reliability. This paper summarizes the thermoelectric, thermal, and radioisotope heat source designs and presents the corresponding performance for a number of mW size thermoelectric micro isotope power sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose prescription complexity versus tumor control probability in biologically conformal radiotherapy

The technical feasibility and potential benefits of voxel-based nonuniform dose prescriptions for biologically heterogeneous tumors have been widely demonstrated. In some cases, an ''ideal'' dose prescription has been generated by individualizing the dose to every voxel within the target, but often this voxel-based prescription has been discretized into a small number of compartments. The number of dose levels utilized and the methods used for prescribing doses and assigning tumor voxels to different dose compartments have varied significantly. The authors present an investigation into the relationship between the complexity of the dose prescription and the tumor control probability (TCP) for a number of these methods. The linear quadratic model of cell killing was used in conjunction with a number of modeled tumors heterogeneous in clonogen density, oxygenation, or proliferation. Models based on simple mathematical functions, published biological data, and biological image data were investigated. Target voxels were assigned to dose compartments using (i) simple rules based on the initial biological distribution, (ii) iterative methods designed to maximize the achievable TCP, or (iii) methods based on an ideal dose prescription. The relative performance of the simple rules was found to depend on the form of heterogeneity of the tumor, while the iterative and ideal dose methods performed comparably for all models investigated. In all cases the maximum achievable TCP was approached within the first few (typically two to five) compartments. Results suggest that irrespective of the pattern of heterogeneity, the optimal dose prescription can be well approximated using only a few dose levels but only if both the compartment boundaries and prescribed dose levels are well chosen.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a Porcine Delayed Wound-Healing Model and Its Use in Testing a Novel Cell-Based Therapy

Purpose: A delayed full-thickness wound-healing model was developed and used for examining the capacity of adipose-derived stem cells (ASCs), either alone or in platelet-rich fibrin gels, to promote healing. Methods and Materials: Four pigs received electron beam radiation to the dorsal skin surface. Five weeks after radiation, subcutaneous fat was harvested from nonirradiated areas and processed to yield ASCs. Two weeks later, 28 to 30 full-thickness 1.5-cm{sup 2} wounds were made in irradiated and nonirradiated skin. Wounds were treated with either saline solution, ASCs in saline solution, platelet-rich plasma (PRP) fibrin gel, ASCs in PRP, or non-autologous green fluorescence protein-labeled ASCs. Results: The single radiation dose produced a significant loss of dermal microvasculature density (75%) by 7 weeks. There was a significant difference in the rate of healing between irradiated and nonirradiated skin treated with saline solution. The ASCs in PRP-treated wounds exhibited a significant 11.2% improvement in wound healing compared with saline solution. Enhancement was dependent on the combination of ASCs and PRP, because neither ASCs nor PRP alone had an effect. Conclusions: We have created a model that simulates the clinically relevant late radiation effects of delayed wound healing. Using this model, we showed that a combination of ASCs and PRP improves the healing rates of perfusion-depleted tissues, possibly through enhancing local levels of growth factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗