Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “New”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

New supersymmetric quartet of nuclei: {sup 192,193}Os-{sup 193,194}Ir

We present evidence for the existence of a new supersymmetric quartet of nuclei in the A{approx}190 mass region. The analysis is based on new experimental information on the odd-odd nucleus {sup 194}Ir from transfer and neutron capture reactions. The new data allow the identification of a new supersymmetric quartet, consisting of the {sup 192,193}Os and {sup 193,194}Ir nuclei. We make explicit predictions for {sup 193}Os, and suggest that its spectroscopic properties be measured in dedicated experiments. Finally, we study correlations between different transfer reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)

Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e {mu}A of {sup 129}Xe{sup 43+}, 22 e {mu}A of {sup 209}Bi{sup 41+}, and 1.5 e {mu}A of {sup 209}Bi{sup 50+}. To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e {mu}A of {sup 129}Xe{sup 27+} and 152 e {mu}A of {sup 129}Xe{sup 30+}, although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and {sup 129}Xe{sup 27+}, {sup 78}Kr{sup 19+}, {sup 209}Bi{sup 31+}, and {sup 58}Ni{sup 19+} beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.

43 PARTICLE ACCELERATORS↗

Fermion Mass Hierarchy and New Physics at the TeV Scale

In this talk, I present a new framework to understand the long-standing fermion mass hierarchy puzzle. We extend the Standard Model gauge symmetry by an extra local U(1){sub S} symmetry, broken spontaneously at the electroweak scale. All the SM particles are singlet with respect to this U(1){sub S}. We also introduce additional flavor symmetries, U(1){sub F}'s, with flavon scalars F{sub i}, as well as vectorlike quarks and leptons at the TeV scale. The flavon scalars have VEV in the TeV scale. Only the top quark has the usual dimension four Yukawa coupling. EW symmetry breaking to all other quarks and leptons are propagated through the messenger field, S through their interactions involving the heavy vector-like fermions and S, as well as through their interactions involving the vector-like fermions and F{sub i}. In addition the explaining the hierarchy of the charged fermion masses and mixings, the model has several interesting predictions for Higgs decays, flavor changing neutral current processes in the top and the b quark decays, decays of the new singlet scalars to the new Z' boson, as well as productions of the new vectorlike quarks. These predictions can be tested at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)

Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose ''burning plasmas.'' D-T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1-18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions.A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of new laser-based alignment system at the KEK B-factory injector linear accelerator

A new laser-based alignment system for the precise alignment of accelerator components along an ideal straight line at the KEK B-factory injector linear accelerator (linac) is under development. This system is strongly required in the next generation of B-factories for the stable acceleration of high-brightness electron and positron beams with high bunch charges and also for maintaining the stability of injection beams with high quality. A new laser optics for the generation of a so-called Airy beam has been developed for the laser-based alignment system. The laser propagation characteristics both in vacuum and at atmospheric pressure have been systematically investigated in an 82-m-long straight section of the injector linac. The laser-based alignment measurements based on the new laser optics have been carried out with a measurement resolution of {+-}0.1 mm level by using an existing laser detection electronics. The horizontal and vertical displacements from a reference laser line measured using this system are in good agreement with those measured using a standard telescope-based optical alignment technique. In this report, we describe the experimental study in detail along with the basic designs and the recent developments in the new laser-based alignment system.

43 PARTICLE ACCELERATORS↗

Studying the Atomic Nucleus - A New Era in Nuclear Structure Studies

The study of atomic nuclei is part of the fascinating quest to understand the fundamental nature and origins of matter. This field, nuclear structure, is undergoing a revolutionary transformation that is breaking cherished paradigms, opening new vistas of nuclear matter for study, and which has the promise of leading to a new comprehensive understanding. The advent of new facilities for the production and study of exotic nuclei provides access to an entirely new territory of nuclei, and advances in extreme computing are enabling similar advances in the theory of atomic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutrino-Nucleus Reactions at MeV Region based on New Shell-Model Hamiltonians

Neutrino-nucleus reactions at MeV region are evaluated by using new shell model Hamiltonians, which are found to improve the description of spin degrees of freedom in nuclei as well as shell evolutions. The light element synthesis by neutrino processes in supernova explosions is discussed with the use of the new reaction cross sections for {sup 12}C and {sup 4}He. Possible constraints on the mixing angle {theta}{sub 13} and the neutrino mass hierarchy are pointed out to be imposed by the production yields of {sup 7}Li and {sup 11}B. Spin-dipole transition strengths in {sup 16}O and neutrino-induced reactions on {sup 16}O are investigated with the new improved Hamiltonian. The Gamow-Teller transition strength in {sup 56}Ni for the new Hamiltonian, which is more fragmented compared to previous calculations, is found to lead to the enhancement of the production yield of {sup 55}Mn in population III stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a mirror-based endoscope for divertor spectroscopy on JET with the new ITER-like wall (invited)

A new endoscope with optimised divertor view has been developed in order to survey and monitor the emission of specific impurities such as tungsten and the remaining carbon as well as beryllium in the tungsten divertor of JET after the implementation of the ITER-like wall in 2011. The endoscope is a prototype for testing an ITER relevant design concept based on reflective optics only. It may be subject to high neutron fluxes as expected in ITER. The operating wavelength range, from 390 nm to 2500 nm, allows the measurements of the emission of all expected impurities (W I, Be II, C I, C II, C III) with high optical transmittance ({>=}30% in the designed wavelength range) as well as high spatial resolution that is {<=}2 mm at the object plane and {<=}3 mm for the full depth of field ({+-}0.7 m). The new optical design includes options for in situ calibration of the endoscope transmittance during the experimental campaign, which allows the continuous tracing of possible transmittance degradation with time due to impurity deposition and erosion by fast neutral particles. In parallel to the new optical design, a new type of possibly ITER relevant shutter system based on pneumatic techniques has been developed and integrated into the endoscope head. The endoscope is equipped with four digital CCD cameras, each combined with two filter wheels for narrow band interference and neutral density filters. Additionally, two protection cameras in the {lambda} > 0.95 {mu}m range have been integrated in the optical design for the real time wall protection during the plasma operation of JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia

The original main control system of the 36 meter small‐angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two‐directional movement of a neutron beam stopper, forward‐backward movement of a 2D position sensitive detector (2D‐PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user‐friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new bidirectional generalization of (2+1)-dimensional matrix k-constrained Kadomtsev-Petviashvili hierarchy

We introduce a new bidirectional generalization of (2+1)-dimensional k-constrained Kadomtsev-Petviashvili (KP) hierarchy ((2+1)-BDk-cKPH). This new hierarchy generalizes (2+1)-dimensional k-cKP hierarchy, (t{sub A}, τ{sub B}) and (γ{sub A}, σ{sub B}) matrix hierarchies. (2+1)-BDk-cKPH contains a new matrix (1+1)-k-constrained KP hierarchy. Some members of (2+1)-BDk-cKPH are also listed. In particular, it contains matrix generalizations of Davey-Stewartson (DS) systems, (2+1)-dimensional modified Korteweg-de Vries equation and the Nizhnik equation. (2+1)-BDk-cKPH also includes new matrix (2+1)-dimensional generalizations of the Yajima-Oikawa and Melnikov systems. Binary Darboux Transformation Dressing Method is also proposed for construction of exact solutions for equations from (2+1)-BDk-cKPH. As an example the exact form of multi-soliton solutions for vector generalization of the DS system is given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new Bi{sub 0.5}Na{sub 0.5}TiO{sub 3} based lead-free piezoelectric system with calculated end-member Bi(Zn{sub 0.5}Hf{sub 0.5})O{sub 3}

The phase structure, dielectric and piezoelectric properties of a new lead-free piezoelectric system (1 − x)Bi{sub 0.5}Na{sub 0.5}TiO{sub 3}–xBi(Zn{sub 0.5}Hf{sub 0.5})O{sub 3} [(1 − x)BNT–xBZH, x = 0, 0.01, 0.02, 0.03, and 0.04] were investigated. The structure of Bi(Zn{sub 0.5}Hf{sub 0.5})O{sub 3} was calculated using first-principles method and (1 − x)BNT–xBZH ceramics were fabricated by conventional solid-state process. At room temperature, a morphotropic phase boundary (MPB) from rhombohedral to pseudocubic is identified near x = 0.02 by the analysis of X-ray diffraction patterns. The ceramics with MPB near room temperature exhibit excellent electrical properties: the Curie temperature, maximum polarization, remnant polarization, and coercive field are 340 °C, 56.3 μC/cm{sup 2}, 43.5 μC/cm{sup 2}, and 5.4 kV/mm, respectively, while the maximum positive bipolar strain and piezoelectric coefficient are 0.09% and 92 pC/N, respectively. In addition, a linear relationship between the MPB phase boundary composition and the calculated tetragonality of non-BNT end-member was demonstrated. Thus, this study not only shows a new BNT-based lead-free piezoelectric system but also suggest a new way to predict the composition at MPB a priori when designing new lead-free piezoelectric system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New metal-organic nanomaterials synthesized by laser irradiation of organic liquids

A new type of metal-organic composition consisting of clusters of nanoparticles has been synthesised by laser irradiation of metallocene/benzene solutions. The metallocene molecules in this reaction become the source of the metal. Exposure to high-energy femtosecond laser pulses dehydrogenate benzene molecules and initiate the high-temperature high-pressure conditions that results in the synthesis of new materials. Irradiation experiments have been carried out on ferrocene/benzene and on other solutions. With ferrocene the synthesis of a new compound has been confirmed by X-ray powder diffraction as the peaks detected do not correspond to any known substance in the Crystallography Open Database. Theoretical simulation of the periodic structure of this new carbide predicts that it has hexagonal symmetry and a unit cell with a = 3.2A and c =2.8A. The exact structure is still uncertain but may be determined from scanning tunneling microscope (STM) studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New compact hohlraum configuration research at the 1.7 MA Z-pinch generator

A new compact Z-pinch x-ray hohlraum design with parallel-driven x-ray sources was experimentally demonstrated in a full configuration with a central target and tailored shine shields (to provide a symmetric temperature distribution on the target) at the 1.7 MA Zebra generator. This presentation reports on the joint success of two independent lines of research. One of these was the development of new sources – planar wire arrays (PWAs). PWAs turned out to be a prolific radiator. Another success was the drastic improvement in energy efficiency of pulsed-power systems, such as the Load Current Multiplier (LCM). The Zebra/LCM generator almost doubled the plasma load current to 1.7 MA. The two above-mentioned innovative approaches were used in combination to produce a new compact hohlraum design for ICF, as jointly proposed by SNL and UNR. Good agreement between simulated and measured radiation temperature of the central target is shown. Experimental comparison of PWAs with planar foil liners (PFL) - another viable alternative to wire array loads at multi-MA generators show promising data. Results of research at the University of Nevada Reno allowed for the study of hohlraum coupling physics at University-scale generators. The advantages of new hohlraum design applications for multi-MA facilities with W or Au double PWAs or PFL x-ray sources are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shear deformable deformation of carbon nanotubes based on a new analytical nonlocal Timoshenko beam nodel

According to Hamilton’s principle, a new mathematical model and analytical solutions for nonlocal Timoshenko beam model (ANT) is established based on nonlocal elastic continuum theory when shear deformation and nonlocal effect are considered. The new ANT equilibrium equations and boundary conditions are derived for bending analysis of carbon nanotubes (CNTs) with simply supported, clamped and cantilever. The ANT deflection solutions demonstrate that the CNT stiffness is enhanced by the presence of nonlocal stress effects. Furthermore, the new ANT model concluded verifiable bending behaviors for a cantilever CNT with point load at the free end, which depends on the strength of nonlocal stress. Therefore, this new model will gives a better prediction for mechanical behaviors of nanostructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ten new predicted covalent organic frameworks with strong optical response in the visible and near infrared

We use density functional theory to predict and evaluate 10 novel covalent organic frameworks (COFs), labeled (X{sub 4}Y)(BDC){sub 3}, (X = C/Si; Y = C, Si, Ge, Sn, and Pb), with topology based on metal organic framework isoreticular metal-organic framework (IRMOF-1), but with new elements substituted for the corner atoms. We show that these new materials are stable structures using frequency calculations. For two structures, (C{sub 4}C and Si{sub 4}C) molecular dynamics simulations were performed to demonstrate stability of the systems up to 600 K for 10 ps. This demonstrates the remarkable stability of these systems, some of which may be experimentally accessible. For the C{sub 4}C material, we also explored the stability of isolated corners and linkers and vacuum and started to build the structure from these pieces. We discuss the equilibrium lattice parameters, formation enthalpies, electronic structures, chemical bonding, and mechanical and optical properties. The predicted bulk moduli of these COFs range from 18.9 to 23.9 GPa, larger than that of IRMOF-1 (ca. 15.4 GPa), and larger than many existing 3D COF materials. The band gaps range from 1.5 to 2.1 eV, corresponding to 600–830 nm wavelength (orange through near infrared). The negative values of the formation enthalpy suggest that they are stable and should be experimentally accessible under suitable conditions. Seven materials distort the crystal structure to a lower space group symmetry Fm-3, while three materials maintain the original Fm-3m space group symmetry. All of the new materials are highly luminescent. We hope that this work will inspire efforts for experimental synthesis of these new materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new smoothing function to introduce long-range electrostatic effects in QM/MM calculations

A new method to account for long range electrostatic contributions is proposed and implemented for quantum mechanics/molecular mechanics long range electrostatic correction (QM/MM-LREC) calculations. This method involves the use of the minimum image convention under periodic boundary conditions and a new smoothing function for energies and forces at the cutoff boundary for the Coulomb interactions. Compared to conventional QM/MM calculations without long-range electrostatic corrections, the new method effectively includes effects on the MM environment in the primary image from its replicas in the neighborhood. QM/MM-LREC offers three useful features including the avoidance of calculations in reciprocal space (k-space), with the concomitant avoidance of having to reproduce (analytically or approximately) the QM charge density in k-space, and the straightforward availability of analytical Hessians. The new method is tested and compared with results from smooth particle mesh Ewald (PME) for three systems including a box of neat water, a double proton transfer reaction, and the geometry optimization of the critical point structures for the rate limiting step of the DNA dealkylase AlkB. As with other smoothing or shifting functions, relatively large cutoffs are necessary to achieve comparable accuracy with PME. For the double-proton transfer reaction, the use of a 22 Å cutoff shows a close reaction energy profile and geometries of stationary structures with QM/MM-LREC compared to conventional QM/MM with no truncation. Geometry optimization of stationary structures for the hydrogen abstraction step by AlkB shows some differences between QM/MM-LREC and the conventional QM/MM. These differences underscore the necessity of the inclusion of the long-range electrostatic contribution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Double crystal monochromator controlled by integrated computing on BL07A in New SUBARU, Japan

The BL07A beamline in New SUBARU, University of Hyogo, has been used for many studies of new materials. A new double crystal monochromator controlled by integrated computing was designed and installed in the beamline in 2014. In this report we will discuss the unique features of this new monochromator, MKZ-7NS. This monochromator was not designed exclusively for use in BL07A; on the contrary, it was designed to be installed at low cost in various beamlines to facilitate the industrial applications of medium-scale synchrotron radiation facilities. Thus, the design of the monochromator utilized common packages that can satisfy the wide variety of specifications required at different synchrotron radiation facilities. This monochromator can be easily optimized for any beamline due to the fact that a few control parameters can be suitably customized. The beam offset can be fixed precisely even if one of the two slave axes is omitted. This design reduces the convolution of mechanical errors. Moreover, the monochromator’s control mechanism is very compact, making it possible to reduce the size of the vacuum chamber can be made smaller.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light leptonic new physics at the precision frontier

Precision probes of new physics are often interpreted through their indirect sensitivity to short-distance scales. In this proceedings contribution, we focus on the question of which precision observables, at current sensitivity levels, allow for an interpretation via either short-distance new physics or consistent models of long-distance new physics, weakly coupled to the Standard Model. The electroweak scale is chosen to set the dividing line between these scenarios. In particular, we find that inverse see-saw models of neutrino mass allow for light new physics interpretations of most precision leptonic observables, such as lepton universality, lepton flavor violation, but not for the electron EDM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗