Feasibility Studies on a Hexagonal-Lattice Core for a World-Class Cold Neutron Source

Cold neutrons have kinetic energies less than 5 meV and wavelengths greater than 4 Α. They can be transported over tens of meters through super-reflecting neutron guides with minimal losses. Cold neutrons are used to investigate the structure of larger molecular systems such as biological materials, polymers and aggregates, due to their preferential interaction with light elements and general ignorance towards heavy ones. Intense beams of cold neutrons are obtained from slowing down a source of thermal energy neutrons - which may be from either a research reactor or spallation neutron source - through some cryogenic moderator such as liquid hydrogen or deuterium. The present reactor at the NIST Center for Neutron Research (NCNR) - NBSR - is such a cold neutron source (CNS) facility which provides cold neutron beams for over 2,000 scientists performing various experiments annually. Feasibility studies on a replacement reactor for the NBSR are underway at NCNR with the primary purpose of optimized cold neutron production. Low enriched uranium (LEU) fuel is required for the new reactor to conform to nuclear non-proliferation agreements. The low thermal power rate of 20 MW is taken as a priority with a fuel cycle length designated as 30 days. A horizontal split compact core with a large D{sub 2}O reflector tank is currently proposed and studied, with the expectation of achieving much better cold neutron performance than the present NIST reactor (NBSR). A preliminary core design has been completed using MCNP6 modeling and simulation. The physics performance characteristics of the proposed new core indicate that the new design is competitive with the most notable existing advanced cold neutron sources. In previous studies, only rectangular shaped fuel elements were considered because they have similar external dimensions as the NBSR fuel elements. However, from a compact core standpoint, a square lattice is not the most effective geometry for a tight configuration. Moreover, the previous studies also showed that the square lattice of the fuel elements left little room to accommodate vertical insertion blade-type control elements. As a result, all control blades had to reside in the D{sub 2}O reflector, which made the design cumbersome (in that case the control blades must penetrate the reflector tank) and neutronically uneconomical. In this summary, a preliminary feasibility study on a hexagonal core lattice is performed to render an alternative geometry for the new reactor (HEX core) to provide sufficient space for the control elements. The identical LEU fuel (U{sub 3}Si{sub 2}/Al) with U-235 enrichment 19.75% is used in the new design. The maximum thermal power and fuel management scheme remain the same as the previous investigations (three 30-day cycled batches for each batch of three fuel elements). The horizontal split compact core concept is also applied in the hexagonal lattice core design, with the objective of creating maximum thermal flux traps between the split core halves. A detailed description of the model for the hexagonal lattice core is presented in the following section. The HEX core design achieves a number of successes over the previous split-core design. Given that much of the motivation of this work was based on implementation of control blades into a concept which lacked them, it is notable that neutron economy was well-preserved in the process of achieving conservatively effective reactivity control; start-up k{sub eff} was in fact increased by 0.23% and peak thermal flux increased by ∼25%. A useful metric in determining the efficacy of resources towards creating an environment for the production of cold neutrons - dubbed the 'quality factor' (QF) - is the ratio of peak thermal neutron flux in a system to the total thermal power produced. Because HEX core's objectives are very focused in comparison to existing research reactors, it is fitting to pursue a design which out-performs all others in terms of some specific performance metric, namely this QF term. While HFIR remains the greatest cold neutron source in the world, it does so through use of HEU fuel (which will be replaced with LEU in the near future), and suffers a greater level of fast neutron contamination that is expected from the HEX design. The new core design achieves these successes due to the hexagonal lattice fuel arrangement, a 13.5% reduction in cladding mass, and a 13.1% reduction in fuel element volume. In spite of a 5.5% reduction in fuel mass, no compromises in reactor performance were noted. Provided the favorable characteristics shown of the control blade design, refueling intervals longer than the prescribed 30 days may be considered. It can be speculated that with these quantitative benefits, the overall capital and continuous costs of the HEX core design will be less than the previously proposed split-core concept.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental validation of an integrated modelling approach to neutron emission studies at JET

An integrated modelling methodology for the calculation of realistic plasma neutron sources for the JET tokamak has been developed. The computational chain comprises TRANSP plasma transport and DRESS neutron spectrum calculations, and their coupling to the MCNP neutron transport code, bridging plasma physics and neutronics. Here, we apply the developed methodology to the analysis of neutron emission properties of deuterium and helium plasmas at JET, and validate individual modelling steps against neutron diagnostic measurements. Two types of JET discharges are modelled—baseline-like and three-ion radio-frequency scenarios—due to their diversity in plasma heating, characteristics of the induced fast ion population, and the imprint of these on neutron emission properties. The neutron emission modelling results are quantitatively compared to the total neutron yield from fission chambers, neutron emissivity profiles from the neutron camera, neutron spectra from the time-of-flight spectrometer, and neutron activation measurements. The agreement between measured and calculated quantities is found to be satisfactory for all four diagnostic systems within the estimated experimental and computational uncertainties. Additionally, the effect of neutrons not originating from the dominating D(D, n) 3 He reactions is studied through modelling of triton burnup DT neutrons, and, in mixed D- 3 He plasmas, neutrons produced in the 9 Be(D, nγ) 10 B reaction on impurities. It is found that these reactions can contribute up to several percent to the total neutron yield and dominate the neutron activation of samples. Finally, the effect of MeV-range fast ions on the neutron activation of 115 In and 27 Al samples is measured and computationally validated.

integrated modelling↗

Current Status and Future Works of Neutron Scattering Laboratory at BATAN in Serpong

Current status of neutron beam instruments using neutrons produced by the Multi Purpose Research Reactor--30MWth (MPR 30, RSG GA Siwabessy) located in Serpong is presented. Description of the reactor as the neutron source is mentioned briefly. There are six neutron beam tubes coming from the beryllium reflector surrounding half of the reactor core providing neutrons in the experimental hall of the reactor (XHR). Four of them are dedicated to R and D in materials science using neutron scattering techniques. Neutron Radiography Facility (NRF), Triple Axis Spectrometer (TAS) and Residual Stress Measurement (RSM) Diffractometer are installed respectively at beam tubes S2, S4 and S6. The largest neutron beam tube (S5) is exploited to accommodate two neutron guide tubes that transfer the neutrons to a neighbouring building called neutron guide hall (NGH). There are three other neutron beam instruments installed in this building, namely Small Angle Neutron Scattering (SANS) Spectrometer (SMARTer), High Resolution SANS (HRSANS) Spectrometer and High Resolution Powder Diffractometer (HRPD). In the XHR, a Four Circle and Texture Diffractometer (FCD/TD) is attached to one of the neutron guide tubes. These seven instruments were installed to utilize the neutrons for materials science research, and recently the RSM diffractometer has shown its capabilities in identifying different amount of stress left due to different treatments of welding in fuel cladding, while the SANS spectrometer is now gaining capabilities in identifying different sizes and shapes of macromolecules in polymers as well as investigations of magnetic samples. In the mean time, non-destructive tests using the NRF is gathering more confidence from some latest real time measurements eventhough there are still some shortcomings in the components and their alignments. Future works including improvement of each facility and its components, even replacement of some parts are necessary and have to be carried out carefully. A plan for developing a neutron reflectometer at one of the neutron guide in the Neutron Guide Hall is also part of the near future activities.

36 MATERIALS SCIENCE↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-element Neutron Energy Spectrometer

In the area of nuclear radiological emergency response and preparedness applications, interest in neutron detection stems from several factors. Unlike gamma rays, which are abundant in nature and present serious difficulties in differentiating a signal from a changing background, whose values are location specific, neutrons are rare and nearly homogenous in spatial distribution. Additionally, many special nuclear materials (SNM) emit neutrons either directly by spontaneous fission or produce neutrons indirectly through (α, n) reactions in nearby light elements. Also of importance in detection scenarios is the fact that neutrons are not easily attenuated. Typically neutron detection is done by simply counting the low energy thermal neutrons by employing pressurized helium tubes operated at high voltages. Not much emphasis is put on determining the energy of the incident neutrons. However, critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the detection of an SNM, neutron energy information from an unknown source can be of paramount importance. We have modeled, designed, and prototyped multi-element neutron energy spectrometers that contain three to five pressurized helium tubes of dimensions 2" diam. x 10" in length. Each individual helium tube has a specific amount of high density plastic neutron moderators to slow down the incident energetic neutrons to an accurately estimated energy. A typical spectrometer is a set of moderator cylinders surrounding detectors that have high efficiency for detecting thermal neutrons. The larger the moderator, the higher the energy of incident neutrons for which the detector assembly has matched detection efficiency. If all the detectors are exposed to the same radiation field and the efficiency as a function of energy (response function) of each of the detectors is known, the neutron energy spectrum can be determined from the detector count rates. Monte Carlo simulation results of response function calculations for different arrays of helium tubes with varying amount of moderators will be shown. Experimental evidence of effectiveness of a set of moderated helium tubes to measure the hardness of the incident neutrons will be demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY07 LDRD Final Report Neutron Capture Cross-Section Measurements at DANCE

We have measured neutron capture cross sections intended to address defense science problems including mix and the Quantification of Margins and Uncertainties (QMU), and provide details about statistical decay of excited nuclei. A major part of this project included developing the ability to produce radioactive targets. The cross-section measurements were made using the white neutron source at the Los Alamos Neutron Science Center, the detector array called DANCE (The Detector for Advanced Neutron Capture Experiments) and targets important for astrophysics and stockpile stewardship. DANCE is at the leading edge of neutron capture physics and represents a major leap forward in capability. The detector array was recently built with LDRD money. Our measurements are a significant part of the early results from the new experimental DANCE facility. Neutron capture reactions are important for basic nuclear science, including astrophysics and the statistics of the {gamma}-ray cascades, and for applied science, including stockpile science and technology. We were most interested in neutron capture with neutron energies in the range between 1 eV and a few hundred keV, with targets important to basic science, and the s-process in particular. Of particular interest were neutron capture cross-section measurements of rare isotopes, especially radioactive isotopes. A strong collaboration between universities and Los Alamos due to the Academic Alliance was in place at the start of our project. Our project gave Livermore leverage in focusing on Livermore interests. The Lawrence Livermore Laboratory did not have a resident expert in cross-section measurements; this project allowed us to develop this expertise. For many radionuclides, the cross sections for destruction, especially (n,{gamma}), are not well known, and there is no adequate model that describes neutron capture. The modeling problem is significant because, at low energies where capture reactions are important, the neutron reaction cross sections show resonance behavior or follow 1/v of the incident neutrons. In the case of odd-odd nuclei, the modeling problem is particularly difficult because degenerate states (rotational bands) present in even-even nuclei have separated in energy. Our work included interpretation of the {gamma}-ray spectra to compare with the Statistical Model and provides information on level density and statistical decay. Neutron capture cross sections are of programmatic interest to defense sciences because many elements were added to nuclear devices in order to determine various details of the nuclear detonation, including fission yields, fusion yields, and mix. Both product nuclei created by (n,2n) reactions and reactant nuclei are transmuted by neutron capture during the explosion. Very few of the (n,{gamma}) cross sections for reactions that create products measured by radiochemists have ever been experimentally determined; most are calculated by radiochemical equivalences. Our new experimentally measured capture cross sections directly impact our knowledge about the uncertainties in device performances, which enhances our capability of carrying out our stockpile stewardship program. Europium and gadolinium cross sections are important for both astrophysics and defense programs. Measurements made prior to this project on stable europium targets differ by 30-40%, which was considered to be significantly disparate. Of the gadolinium isotopes, {sup 151}Gd is important for stockpile stewardship, and {sup 153}Gd is of high interest to astrophysics, and nether of these (radioactive) gadolinium (n,{gamma}) cross sections have been measured. Additional stable gadolinium isotopes, including {sup 157,160}Gd are of interest to astrophysics. Historical measurements of gadolinium isotopes, including {sup 152,154}Gd, had disagreements similar to the 30-40% disagreements found in the historical europium data. Actinide capture cross section measurements are important for both Stockpile Stewardship and for nuclear forensics. We focused on the {sup 242m}Am(n,{gamma}) measurement, as there was no existing capture measurement for this isotope. The cross-section measurements (cross section vs. E{sub n}) were made at the Detector for Advanced Neutron Capture Experiments. DANCE is comprised of a highly segmented array of barium fluoride (BaF{sub 2}) crystals specifically designed for neutron capture-gamma measurements, using small radioactive targets (less than one milligram). A picture of half the array, along with a photo of one crystal, is shown in Fig. 1. DANCE provides the world's leading capability for measurements of neutron capture cross sections with radioactive targets. The DANCE is a 4{pi} calorimeter and uses the intense spallation neutron source the Lujan Center at the Los Alamos National Laboratory. The detector array consists of 159 barium fluoride crystals arranged in a sphere around the target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of Multi-Step CADIS Parameter Sensitivity to Neutron Flux Spectrum in Shutdown Dose Rate Calculations

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final dose rate. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. For example, SDDR assessments are required throughout the biological shield (bio-shield) of the ITER experimental facility to evaluate the required waiting period after the shutdown of ITER and to identify the locations where human accessibility should be prohibited. The bio-shield is a large cylindrical concrete structure (30 m tall and 34 m in diameter) surrounding the very complex tokamak machine. Determining the effects on SDDR of important factors, such as the cross talk (interactions) between the different ports of ITER, is possible only through full-scale simulations that involve all the complex inner details of the ITER tokamak machine. These simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate the distribution of radioisotopes causing the SDDR. Determining a good importance function that can be used in biasing a neutron MC calculation for SDDR is complicated because it is difficult to explicitly express the SDDR response function, which depends on subsequent computational steps. The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method was developed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. The MS-CADIS method uses the CADIS method, which has been Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC0500OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for the United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). successfully used for more than a decade in radiation shielding applications to generate consistent source biasing and weight window (WW) variance reduction parameters to accelerate continuous-energy MC simulations. However, because MS-CADIS focuses on multi-step shielding calculations such as SDDR calculations, it develops an importance function for the initial radiation transport calculation (e.g., the neutron calculations in SDDR simulations) that represents the importance of particles to the final response of the overall simulation. To develop this importance function, the MS-CADIS method uses an adjoint calculation with a specific neutron adjoint source that represents the neutron's contribution to the final SDDR. Brute force calculation of the MS-CADIS neutron adjoint source requires a deterministic neutron transport calculation coupled with activation calculations in each element of the deterministic mesh. These calculations are needed to determine the MS-CADIS parameter for the neutron interactions that produce radioisotopes contributing to the SDDR. The MS-CADIS parameter is the microscopic cross section of the radioisotope-producing interaction, multiplied by the mass of this radioisotope existing at the end of the irradiation and decay scenario, and divided by the steady-state rate of the interaction. Because the activation calculations are performed for each radionuclide in each mesh element, implementation of the MS-CADIS method can be computationally expensive. However, these neutron transport and activation calculations are not needed if we assume that the radioisotopes are created due to single neutron interactions and their concentrations do not change as a result of burnup by neutron irradiation. The use of this approximation, which renders the MS-CADIS parameter independent of the neutron flux, seems reasonable in calculating the MS-CADIS importance function because this function is needed only to speed up the MC calculation, not to calculate the final SDDR. In this work, we investigate the validity of this approximation by investigating the behavior of the MS-CADIS parameter as a function of the neutron flux spectra in the Fusion Evaluated Nuclear Data Library (FENDL) Neutronics and Shielding Benchmark problem that contains representative isotopes and flux environments of fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

2022 American Conference on Neutron Scattering (ACNS 2022)

The 11th American Conference on Neutron Scattering (ACNS 2022) will be held on June 5-9, 2022, in Boulder, CO. The Conference will provide essential information on the breadth and depth of current neutron-related research worldwide. Hosted by the Neutron Scattering Society of America, this year’s Conference will feature a combination of invited and contributed talks, poster sessions, and tutorials. Topics of the conference are: Advances in Neutron Facilities, Instrumentation and Software: Developments in sources, instrumentation, sample environments and control software. Hard Condensed Matter: Magnetism, correlated metals, quantum/topological materials, superconductors, ferroelectrics, multiferroics, glasses, and disorder phenomena. Submissions outlining examples of neutron scattering in industrial and engineering applications involving hard condensed matter systems are also encouraged. Soft Matter: Neutron studies of soft materials and related fields including in situ and in operando studies. Polymers, surfactants, emulsions, gels, nanoparticles, colloidal suspensions and more. Submissions of computational studies or applications of machine learning beneficial to neutron scattering experiments, as well as examples of neutron scattering in industrial and engineering applications are strongly encouraged. Biology, Biophysics and Biotechnology: Neutron studies of biological and biologically relevant systems. Proteins, bio membranes, biological assemblies, natural materials, nucleic acids, drug-delivery platforms and biomedical systems. Submissions of computational studies or applications of machine learning beneficial to biological neutron scattering experiments, as well as examples of neutron scattering in applied research involving biological systems, are strongly encouraged. Materials Chemistry and Energy: Neutron-based studies of functional materials and materials for energy applications. Examples include porous materials such as metal organic frameworks (MOFs), zeolites; phosphors; novel pigments; electrolytes; catalysts; ionic conductors/cathode materials; photovoltaic materials (hybrid perovskites); thermoelectrics; magnetocalorics/electrocalorics. Structural Materials and Engineering: Neutron scattering studies of materials and engineering processes including structural materials, concrete and metals, as well as engineering processes including combustion, corrosion, additive manufacturing, and others. Neutron Physics: Fundamental physical studies of the neutron and related areas. Emerging Applications in Neutron Scattering: Machine Learning and Data Science: Advances in computing power have contributed to rapidly evolving machine learning and data science fields that can be leveraged to the benefit of the neutron scattering community. The purpose of this session is to highlight recent advances in machine learning and data science and to serve as the foundation of a parallel data and computation track highlighting computation advances and applications in neutron scattering throughout the conference.

36 MATERIALS SCIENCE↗

The 14 MeV Neutron Irradiation Facility in MARIA Reactor

The MARIA reactor with thermal neutron flux density up to 3x10{sup 14} cm{sup -2} s{sup -1} and a number of vertical channels is well suited to material testing by thermal neutron treatment. Beside of that some fast neutron irradiation facilities are operated in MARIA reactor as well. One of them is thermal to 14 MeV neutron converter launched in 2014. It is especially devoted to fusion devices material testing irradiation. The ITER and DEMO research thermonuclear facilities are to be run using the deuterium - tritium fusion reaction. Fast neutrons (of energy approximately 14 MeV) resulting from the reaction are essential to carry away the released thermonuclear energy and to breed tritium. However, constructional materials of which thermonuclear reactors are to be built must be specially selected to survive intense fluxes of fast neutrons. Strong sources of 14 MeV neutrons are needed if research on resistance of candidate materials to such fluxes is to be carried out effectively. Nuclear reactor-based converter capable to convert thermal neutrons into 14 MeV fast neutrons may be used to that purpose. The converter based on two stage nuclear reaction on lithium-6 and deuterium compounds leading to 14 MeV neutron production. The reaction chain is begun by thermal neutron capture by lithium-6 nucleus resulted in triton release. The neutron and triton transport calculations have been therefore carried-out to estimate the thermal to 14 MeV neutron conversion efficiency and optimize converter construction. The usable irradiation space of ca. 60 cm{sup 3} has been obtained. The released energy have been calculated. Heat transport has been asses to ensure proper device cooling. A set of thermocouples has been installed in converter to monitor its temperature distribution on-line. Influence of converter on reactor operation has been studied. Safety analyses of steady states and transients have been done. Performed calculations and analyses allow designing the converter and formulate its operation limits and conditions. During first tested operation of the converter the 14 MeV neutron flux density was estimated to 10{sup 9} cm{sup -2} s{sup -1}, whereas fast fission neutrons inside converter achieved 10{sup 12} cm{sup -2} s{sup -1}, and thermal neutrons were reduced down to 109 cm-2 s-1. Taking into account the feasibility of almost incessant converter operation for a number of months, its arisen as one of the most powerful (in terms of fluence), currently available 14 MeV neutron source. Such a converter currently under operation in the MARIA reactor core will be presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts associated to each detector type will play a major role in the selection of the detector types used for the SINRD measurement. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-90: Accuracy of Calibration of Lithium-6 and -7 Enriched LiF TLDs for Neutron Measurements in High Energy Radiotherapy

Purpose: To determine the potential error involved in the interpretation of neutron measurements from medical linear accelerators (linacs) using TLD-600H and TLD-700H if standard AmBe and {sup 252}Cf neutron sources are used for calibration without proper inclusion of neutron energy spectrum information. Methods: The Kerma due to neutrons can be calculated from the energy released by various nuclear interactions (elastic and inelastic scatter, (n,α), (n,p), (n,d), (n,t), (n,2n), etc.). The response of each TLD can be considered the sum of the neutron and gamma components; each proportional to the Kerma. Using the difference between the measured TLD responses and the ratio of the calculated Kerma for each material, the neutron component of the response can be calculated. The Monte Carlo code MCNP6 has been used to calculate the neutron energy spectra resulting from photonuclear interactions in a Varian 21EX linac. TLDs have been exposed to the mixed (γ-n) field produced by a linac and AmBe and {sup 252}Cf standard neutron sources. Results: For dosimetry of neutrons from AmBe or {sup 252}Cf sources, assuming TLD-700H insensitivity to neutrons will Result in 10% or 20% overestimation of neutron doses respectively.For dosimetry of neutrons produced in a Varian 21EX, applying a calibration factor derived from a standard AmBe or {sup 252}Cf source will Result in an overestimation of neutron fluence, by as much as a factor of 47.The assumption of TLD-700H insensitivity to neutrons produced by linacs leads to a negligible error due to the extremely high Kerma ratio (600H/700H) of 3000 for the assumed neutron spectrum. Conclusion: Lithium-enriched TLDs calibrated with AmBe and/or {sup 252}Cf neutron sources are not accurate for use under the neutron energy spectrum produced by a medical linear accelerator.

60 APPLIED LIFE SCIENCES↗

Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron Imaging at LANSCE—From Cold to Ultrafast

In recent years, neutron radiography and tomography have been applied at different beam lines at Los Alamos Neutron Science Center (LANSCE), covering a very wide neutron energy range. The field of energy-resolved neutron imaging with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as quantitative density measurements, was pioneered at the Target 1 (Lujan center), Flight Path 5 beam line and continues to be refined. Applications include: imaging of metallic and ceramic nuclear fuels, fission gas measurements, tomography of fossils and studies of dopants in scintillators. The technique provides the ability to characterize materials opaque to thermal neutrons and to utilize neutron resonance analysis codes to quantify isotopes to within 0.1 atom %. The latter also allows measuring fuel enrichment levels or the pressure of fission gas remotely. More recently, the cold neutron spectrum at the ASTERIX beam line, also located at Target 1, was used to demonstrate phase contrast imaging with pulsed neutrons. This extends the capabilities for imaging of thin and transparent materials at LANSCE. In contrast, high-energy neutron imaging at LANSCE, using unmoderated fast spallation neutrons from Target 4 [Weapons Neutron Research (WNR) facility] has been developed for applications in imaging of dense, thick objects. Using fast (ns), time-of-flight imaging, enables testing and developing imaging at specific, selected MeV neutron energies. The 4FP-60R beam line has been reconfigured with increased shielding and new, larger collimation dedicated to fast neutron imaging. The exploration of ways in which pulsed neutron beams and the time-of-flight method can provide additional benefits is continuing. We will describe the facilities and instruments, present application examples and recent results of all these efforts at LANSCE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphysics approach to plasma neutron source modelling at the JET tokamak

A novel multiphysics methodology for the computation of realistic plasma neutron sources has been developed. The approach is based on state-of-the-art plasma transport and neutron spectrum calculations, coupled with a Monte Carlo neutron transport code, bridging the gap between plasma physics and neutronics. In the paper two JET neutronics tokamak models are used to show the application of the developed plasma neutron sources and validate them. Diagnostic data for the record JET D discharge 92436 are used as input for the TRANSP code, modelling neutron emission in two external plasma heating scenarios, namely using only neutral beam injection and a combination of the latter and ion cyclotron resonance heating. Neutron spectra, based on plasma transport results, are computed using the DRESS code. The developed PLANET code package is employed to generate plasma neutron source descriptions and couple them with the MCNP code. The effects of using the developed sources in neutron transport calculations on the response of JET neutron diagnostic systems is studied and compared to the results obtained with a generic plasma neutron source. It is shown that, although there are significant differences in the emissivity profiles, spectra shape and anisotropy between the neutron sources, the integral response of the time-resolved ex-vessel neutron detectors is largely insensitive to source changes, with major relative deviations of up to several percent. However it is calculated that, because of the broadening of neutron spectra as a consequence of external plasma heating, larger differences may occur in activation of materials which have threshold reactions located at DD neutron peak energies. The PLANET plasma neutron source computational methodology is demonstrated to be suitable for detailed neutron source effect studies on JET during DT experiments and can be applied to ITER analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗