Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement Science Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Optical Properties of Airborne Soil Organic Particles

Recently, airborne soil organic particles (ASOP) were reported as a type of solid organic particles emitted after water droplets impacted wet soils. Chemical constituents of ASOP are macromolecules such as polysaccharides, tannins, and lignin (derived from degradation of plants and biological organisms). Optical properties of ASOP were inferred from the quantitative analysis of the electron energy-loss spectra acquired over individual particles in the transmission electron microscope. The optical constants of ASOP are further compared with those measured for laboratory generated particles composed of Suwanee River Fulvic Acid (SRFA) reference material, which was used as a laboratory surrogate of ASOP. The particle chemical compositions were analyzed using energy dispersive x-ray spectroscopy, electron energy-loss spectroscopy, and synchrotron-based scanning transmission x-ray microscopy with near edge x-ray absorption fine structure spectroscopy. ASOP and SRFA exhibit similar carbon composition, but SRFA has minor contributions of S and Na. When ASOP are heated to 350 °C their absorption increases as a result of their pyrolysis and partial volatilization of semi-volatile organic constituents. The retrieved refractive index (RI) at 532 nm of SRFA particles, ASOP, and heated ASOP were 1.22-62 0.07i, 1.29-0.07i, and 1.90-0.38i, respectively. Compared to RISRFA, RIASOP has a higher real part but similar imaginary part. These measurements of ASOP optical constants suggest that they have properties characteristic of atmospheric brown carbon and therefore their potential effects on the radiative forcing of climate need to be assessed in atmospheric models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ballistic penetration test results for Ductal and ultra-high performance concrete samples.

This document provides detailed test results of ballistic impact experiments performed on several types of high performance concrete. These tests were performed at the Sandia National Laboratories Shock Thermodynamic Applied Research Facility using a 50 caliber powder gun to study penetration resistance of concrete samples. This document provides test results for ballistic impact experiments performed on two types of concrete samples, (1) Ductal{reg_sign} concrete is a fiber reinforced high performance concrete patented by Lafarge Group and (2) ultra-high performance concrete (UHPC) produced in-house by DoD. These tests were performed as part of a research demonstration project overseen by USACE and ERDC, at the Sandia National Laboratories Shock Thermodynamic Applied Research (STAR) facility. Ballistic penetration tests were performed on a single stage research powder gun of 50 caliber bore using a full metal jacket M33 ball projectile with a nominal velocity of 914 m/s (3000 ft/s). Testing was observed by Beverly DiPaolo from ERDC-GSL. In all, 31 tests were performed to achieve the test objectives which were: (1) recovery of concrete test specimens for post mortem analysis and characterization at outside labs, (2) measurement of projectile impact velocity and post-penetration residual velocity from electronic and radiographic techniques and, (3) high-speed photography of the projectile prior to impact, impact and exit of the rear surface of the concrete construct, and (4) summarize the results.

36 MATERIALS SCIENCE↗

Parallax diagnostics of radiation source geometric dilution for iron opacity experiments

Experimental tests are in progress to evaluate the accuracy of the modeled iron opacity at solar interior conditions [J. E. Bailey et al., Phys. Plasmas 16, 058101 (2009)]. The iron sample is placed on top of the Sandia National Laboratories z-pinch dynamic hohlraum (ZPDH) radiation source. The samples are heated to 150–200 eV electron temperatures and 7× 10{sup 21}–4× 10{sup 22} cm{sup −3} electron densities by the ZPDH radiation and backlit at its stagnation [T. Nagayama et al., Phys. Plasmas 21, 056502 (2014)]. The backlighter attenuated by the heated sample plasma is measured by four spectrometers along ±9° with respect to the z-pinch axis to infer the sample iron opacity. Here, we describe measurements of the source-to-sample distance that exploit the parallax of spectrometers that view the half-moon-shaped sample from ±9°. The measured sample temperature decreases with increased source-to-sample distance. This distance must be taken into account for understanding the sample heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Site Environmental Report for 2010 Sandia National Laboratories, California.

Sandia National Laboratories, California (SNL/CA) is a government-owned/contractor-operated laboratory. Sandia Corporation, a Lockheed Martin Company, manages and operates the laboratory for the Department of Energy's National Nuclear Security Administration (NNSA). The NNSA Sandia Site Office administers the contract and oversees contractor operations at the site. This Site Environmental Report for 2010 was prepared in accordance with DOE Order 231.1A (DOE 2004a). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2010. General site and environmental program information is also included. The Site Environmental Report is divided into ten chapters. Chapter 1, the Executive Summary, highlights compliance and monitoring results obtained in 2010. Chapter 2 provides a brief introduction to SNL/CA and the existing environment found on site. Chapter 3 summarizes SNL/CA's compliance activities with the major environmental requirements applicable to site operations. Chapter 4 presents information on environmental management, performance measures, and environmental programs. Chapter 5 presents the results of monitoring and surveillance activities in 2010. Chapter 6 discusses quality assurance. Chapters 7 through 9 provide supporting information for the report and Chapter 10 is the report distribution list.

54 ENVIRONMENTAL SCIENCES↗

Development of Analytical Protocols For Organics and Isotopes Analysis on the 2009 MARS Science Laboratory.

The Mars Science Laboratory, under development for launch in 2009, is designed explore and quantitatively asses a local region on Mars as a potential habitat for present or past life. Its ambitious goals are to (1) assess the past or present biological potential of the target environment, (2) to characterize the geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The planned capabilities of the rover payload will enable a comprehensive search for organic molecules, a determination of definitive mineralogy of sampled rocks and fines, chemical and isotopic analysis of both atmospheric and solid samples, and precision isotope measurements of several volatile elements. A range of contact and remote surface and subsurface survey tools will establish context for these measurements and will facilitate sample identification and selection. The Sample Analysis at Mars (SAM) suite of MSL addresses several of the mission's core measurement goals. It includes a gas chromatograph, a mass spectrometer, and a tunable laser spectrometer. These instruments will be designed to analyze either atmospheric samples or gases extracted from solid phase samples such as rocks and fines. We will describe the range of measurement protocols under development and study by the SAM engineering and science teams for use on the surface of Mars.

Mahaffy, P. R.↗

Middle UV to Near-IR Spectrum of Electron-Excited SO2

We investigated the electron impact-induced fluorescence spectrum of SO2 to provide excitation cross sections for modeling Io's mission spectrum and analyzing Cassini Imaging Science Subsystem observations. The electron-excited middle-ultraviolet visible optical near-infrared (VOIR) emission spectrum of SO2 gas was generated in the laboratory and studied from 2000 to 11,000 A at a resolution of (Delta)(lamda) approximately 2.5 A full width at half maximum (FWHM). The VOIR laboratory spectrum longward of 6000 A consists entirely of S I, II and O I, II multiplets for electron impact energies above approximately 15 eV. Between 2000 and 6000 A, we find previously identified molecular bands from both SO and SO2. This work represents a significant improvement in spectral resolution over our earlier work done at 18 A FWHM. From a measurement of the medium-resolution spectrum, we provide detailed 25- and 100-eV emission cross sections for spectral features from 2000 to 11,000 A . On the basis of these data, we suggest future ground-based and satellite telescopic observations in the VOIR that are of promise for understanding Io's atmosphere.

sulpher dioxide↗

Radiometric Calibration of A Non-Imaging Airborne Spectrometer To Measure the Greenland Ice Sheet Surface

Methods to radiometrically calibrate a non-imaging airborne visible-to-shortwave infrared (VSWIR) spectrometer to measure the Greenland ice sheet surface are presented. Airborne VSWIR measurement performance for bright Greenland ice and dark bare rock/soil targets is compared against the MODerate resolution atmospheric TRANsmission (MODTRAN ® ) radiative transfer code (version 6.0), and a coincident Landsat 8 Operational Land Imager (OLI) acquisition on 29 July 2015 during an in-flight radiometric calibration experiment. Airborne remote sensing flights were carried out in northwestern Greenland in preparation for the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2) laser altimeter mission. A total of nine science flights were conducted over the Greenland ice sheet, sea ice, and open-ocean water. The campaign's primary purpose was to correlate green laser pulse penetration into snow and ice with spectroscopic-derived surface properties. An experimental airborne instrument configuration that included a nadir-viewing (looking downward at the surface) non-imaging Analytical Spectral Devices (ASD) Inc. spectrometer that measured upwelling VSWIR (0.35 to 2.5 µm) spectral radiance (Wm −2 sr −1 µm −1 ) in the two-color Slope Imaging Multi-polarization Photon-Counting Lidar's (SIMPL) ground instantaneous field of view, and a zenith-viewing (looking upward at the sky) ASD spectrometer that measured VSWIR spectral irradiance (W m −2 nm −1 ) was flown. National Institute of Standards and Technology (NIST) traceable radiometric calibration procedures for laboratory, in-flight, and field environments are described in detail to achieve a targeted VSWIR measurement requirement of within 5 % to support calibration/validation efforts and remote sensing algorithm development. Our MODTRAN predictions for the 29 July flight line over dark and bright targets indicate that the airborne nadir-viewing spectrometer spectral radiance measurement uncertainty was between 0.6 % and 4.7 % for VSWIR wavelengths (0.4 to 2.0 µm) with atmospheric transmittance greater than 80 %. MODTRAN predictions for Landsat 8 OLI relative spectral response functions suggest that OLI is measuring 6 % to 16 % more top-of-atmosphere (TOA) spectral radiance from the Greenland ice sheet surface than was predicted using apparent reflectance spectra from the nadir-viewing spectrometer. While more investigation is required to convert airborne VSWIR spectral radiance into atmospherically corrected airborne surface reflectance, it is expected that airborne science flight data products will contribute to spectroscopic determination of Greenland ice sheet surface optical properties to improve understanding of their potential influence on ICESat-2 measurements.

Christopher J. Crawford↗

Valence-to-core X-ray emission spectroscopy of titanium compounds using energy dispersive detectors

X-ray emission spectroscopy (XES) of transition metal compounds is a powerful tool for investigating the spin and oxidation state of the metal centers. Valence-to-core (vtc) XES is of special interest, as it contains information on the ligand nature, hybridization, and protonation. To date, most vtc-XES studies have been performed with high-brightness sources, such as synchrotrons, due to the weak fluorescence lines from vtc transitions. Here, we present a systematic study of the vtc-XES for different titanium compounds in a laboratory setting using an X-ray tube source and energy dispersive microcalorimeter sensors. With a full-width at half-maximum energy resolution of approximately 4 eV at the Ti Kβ lines, we measure the XES features of different titanium compounds and compare our results for the vtc line shapes and energies to previously published and newly acquired synchrotron data as well as to new theoretical calculations. Finally, we report simulations of the feasibility of performing time-resolved vtc-XES studies with a laser-based plasma source in a laboratory setting. Our results show that microcalorimeter sensors can already perform high-quality measurements of vtc-XES features in a laboratory setting under static conditions and that dynamic measurements will be possible in the future after reasonable technological developments.

36 MATERIALS SCIENCE↗

International cooperation in age-dating uranium standards for nuclear forensics using the 231 Pa/ 235 U radiochronometer

During 2017–2018 Los Alamos National Laboratory, Lawrence Livermore National Laboratory and the China Institute of Atomic Energy collaborated in an interlaboratory 231 Pa/ 235 U radiochronometry exercise. The laboratories used different analytical methods to obtain a consensus model purification date for CRM U010 of December 28, 1958 ± 198 days and for CRM U850 of May 20, 1958 ± 363 days. These results agree with previously reported model dates using the 230 Th/ 234 U radiochronometer as well as the production histories of these materials. The concordance of interlaboratory data here confirms the ability of laboratories to make reproducible radiochronometry measurements using distinct analytical approaches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First real-time detection of surface dust in a tokamak

The first real-time detection of surface dust inside a tokamak was made using an electrostatic dust detector. A fine grid of interlocking circuit traces was installed in the NSTX vessel and biased to 50 V. Impinging dust particles created a temporary short circuit and the resulting current pulse was recorded by counting electronics. The techniques used to increase the detector sensitivity by a factor of x10 000 to match NSTX dust levels while suppressing electrical pickup are presented. The results were validated by comparison to laboratory measurements, by the null signal from a covered detector that was only sensitive to pickup, and by the dramatic increase in signal when Li particles were introduced for wall conditioning purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of High Coercitivity PrFeB Magnets at the Louis Neel Lab

Magnetization curves of newly developed high coercivity PrFeB magnets have been measured at various temperatures down to 40K. The measurement was carried out at the Lous Néel Laboratory in Grenoble, France using its 11T superconducting magnetometer. It has been shown that no significant gain in performance can be achieved below 77K where one can expect 16% gain in the remanence compared to that at a room temperature.

36 MATERIALS SCIENCE↗

An Analytical Model of Erosive Wear of BioMass Comminution Components

An analytical erosion model that relates critical process parameters (speed and impingement angle) to critical material attributes of inorganic mineral species in feedstock (density, size, aspect ratio) and substrate (hardness, toughness, and fatigue ductility) was applied to model wear in pretreatment milling operations. Results of the model were compared to experimental measurements of wear produced using the Accelerated Wear Test (AWT) rig at Idaho National Laboratory (INL). Results showed that there is good agreement between predicted and measured performance, and that a quality-by-design (QbD) tool can be developed to predict component reliability based on scientific engineering principles in lieu of trial-and-error approaches.

09 BIOMASS FUELS↗

CERBERUS: A Multi-Purpose Spectrometer and Alignment Station at SNS

In order to maximally utilize the existing beam ports at the Spallation Neutron Source, development and installation of a new neutron instrument is proposed at beam port 16a within building 8700 at Oakridge National Laboratory. Said instrument will provide nominally equal neutron beam access for three main science purposes; (1) as an alignment station for proposed single-crystal spectrometer samples to be run across the facility, (2) as a Near-Infrared (>100meV) filter analyzer spectrometer, nearly identical to that which was previously housed at the Lujan Center in Los Alamos, and (3) as a high-throughput nuclear cross-section measurement station. These three experimental applications would require no substantial technical developments, are complimentary in their technical requirements, and provide a worth-while capability that is infinitely beyond the current use of the 16a beam port at the First Target Station within the SNS complex. All three methods would enhance the facility’s science contributions, while accommodating two niche experiment methods that may not be strong enough to stand on their own.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GROWdb US River Systems - Samples

GROW Overview We developed the Genome Resolved Open Watersheds database (GROWdb), which aims to increase genomic sampling and understanding of global river microbiomes. An emphasis of GROWdb is to create a publicly available and ever-expanding microbial genome database that is focused on rivers while being interoperable with databases from other ecosystems. GROWdb is based on a network-of-networks approach to move beyond a small collection of well-studied rivers, towards a spatially distributed, global network of systematic observations. GROWdb represents the first microbial, river-focused resource parsed at various scales from genes to MAGs to community level including expression and potential based measurements that will be of interest to microbiologists, ecologists, geochemists, hydrologists, and modelers. Dataset Acknowledgement GROWdb contains data from various research campaigns, please acknowledge the following data generators, as appropriate: WHONDRS derived genomes or samples - include this statement in your acknowledgements: “This study used data from the Worldwide Hydrobiogeochemistry Observation Network for Dynamic River Systems (WHONDRS) under the River Corridor Science Focus Area (SFA) at the Pacific Northwest National Laboratory (PNNL) that was generated at the U.S. Department of Energy (DOE) Joint Genome Institute User Facility. PNNL is operated by Battelle Memorial Institute for the U.S. DOE under Contract No. DE-AC05-76RL01830. The SFA is supported by the U.S. DOE, Office of Biological and Environmental Research (BER), Environmental System Science (ESS) Program.” Total Samples loaded onto this Narrative: 178 Note: Not all GROW samples may be loaded into KBase Data Availability The data underlying GROWdb are accessible across various platforms to ensure all levels of data structure are widely available. First, all reads and MAGs are publicly hosted on National Center for Biotechnology (NCBI) under Bioproject PRJNA946291. Second, all data related data presented here including MAG annotations, extended data tables, phylogenetic tree files, antibiotic resistance gene database files, and MAG abundance tables are available in Zenodo (link). Beyond the flat database files listed above, our aim for GROWdb was to maximize data use by making the data available in searchable and interactive platforms including the National Microbiome Data Collaborative (NMDC) data portal, the Department of Energy’s Systems Biology Knowledgebase (KBase), and a GROW specific user interface released here, GROWdb Explorer. Each platform provides different ways to interact with GROWdb: NMDC GROWdb formed a pilot project for the NMDC. Specifically, individual GROWdb datasets (metagenomes, metatranscriptomes, etc) are easily accessible and searchable through the NMDC data portal, where they are systematically connected to each other and to a rich suite of sample information and standard analysis results, following Findable, Accessible, Interoperable, and Reusable (FAIR) data practices. KBase GROWdb is publicly available within KBase, including samples (this Narrative), MAGs, and corresponding genome scale metabolic models. Access within KBase allows for immediate access and reuse of data, including comparison to private data using KBase’s 500+ analysis tools. Other linked narratives in KBase: GROW Metagenome Assembled Genomes (MAGs) GROW Metabolic Models GROWdb Explorer GROWdb data is also explorable through a graphical user interface built through the Colorado State University Geospatial Centroid (https://geocentroid.shinyapps.io/GROWdatabase/), allowing users to search and graph microbial and spatial data simultaneously. In summary, this microbial genome resource represents the first publicly available genome collection from rivers and offers data that can be leveraged across microbiome studies. GROWdb is an expanding repository to incorporate and unify global river multi-omic data for the future.

59 BASIC BIOLOGICAL SCIENCES↗

A mission and system design option for the Orbiting Stellar Interferometer

The Orbiting Stellar Interferometer (OSI) is a proposed space-based observatory that will open exciting new vistas in astronomy and address fundamental scientific questions by making extremely accurate (3 to 30 microarcsecond) astrometric measurements of the positions of stars, quasars, and other astronomical objects as faint as magnitude 20. In addition, it will be able to image objects with a resolution of about 13 milliarcseconds. Using the lessons learned from the development of a point design for OSI, the Jet Propulsion Laboratory has developed a new conceptual design, with emphasis on reducing its cost and complexity while maximizing the return of valuable science.

Rayman, M. D.↗

DRAGONS-A Micrometeoroid and Orbital Debris Impact Sensor on the ISS

The Debris Resistive/Acoustic Grid Orbital Navy-NASA Sensor (DRAGONS) is intended to be a large area impact sensor for in situ measurements of micrometeoroids and orbital debris (MMOD) in the sub-millimeter to millimeter size regime in the near Earth space environment. These MMOD particles are too small to be detected by ground-based radars and optical telescopes, but still large enough to be a serious threat to human space activities and robotic missions in the low Earth orbit (LEO) region. The nominal detection area of DRAGONS is 1 sq m, consisting of four 0.5 m × 0.5 m independent panels, but the dimensions of the panels can easily be modified to accommodate different payload constraints. The approach of the DRAGONS design is to combine three particle impact detection concepts to maximize information that can be extracted from each detected impact. The first is a resistive grid consisting of 75-micrometer-wide resistive lines, coated in parallel and separated by 75 micrometer gaps on a 25-micrometer thin film. When a particle a few hundred micrometers or larger strikes the grid, it would penetrate the film and sever some resistive lines. The size of the damage area can be estimated from the increased resistance. The second concept is based on polyvinylidene fluoride (PVDF) acoustic impact sensors. Multiple PVDF sensors are attached to the thin film to provide the impact timing information. From the different signal arrival times at different acoustic sensors, the impact location can be calculated via triangulation algorithms. The third concept employs a dual-layer film system where a second 25-micrometer film is placed 15 cm behind the resistive-grid film. Multiple PVDF acoustic sensors are also attached to the second film. The combination of impact timing and location information from the two films allows for direct measurements of the impact direction and speed. The DRAGONS technology development has been funded by several NASA organizations since 2002, first by the NASA Science Mission Directorate and the NASA Exploration Systems Mission Directorate, then by the NASA JSC Innovative Research and Development Program and the NASA Orbital Debris Program Office. The NASA Orbital Debris Program Office leads the effort with collaboration from the U.S. Naval Academy, Naval Research Laboratory, University of Kent at Canterbury in Great Britain, and Virginia Tech. The project recently reached a major milestone when DRAGONS was approved for a technology demonstration mission by the International Space Station (ISS) Program in October 2014. The plan is to deploy a 1 sq m DRAGONS on the ISS with the detection surface facing the ram-direction for 2 to 3 years. The tentative launch schedule is in early 2017. This mission will collect data on orbital debris in the sub-millimeter size regime to better define the small orbital debris environment at the ISS altitude. The mission will also advance the DRAGONS Technology Readiness Level to 9 and greatly enhance the opportunities to deploy DRAGONS on other spacecraft to high LEO orbits in the future.

Liou, J.-C.↗

Quantum Speedup for Aeroscience and Engineering

Algorithms and hardware for quantum computing (QC) are reaching a critical stage in their development and have the potential to generate a paradigm shift in computing capability across a range of fields. Opportunities are growing for genuine impact of these systems over a timescale of 10-15 years, and there has been significant investment both from government agencies and private industry in its development. However, utilization of quantum phenomena is extraordinarily challenging due to its delicate nature and difficulties in measurement and control. A clear path exists toward demonstrating the advantages of QC over existing high-performance computing for some physics and materials science problems but addressing practical computational challenges in other fields, though promising, is at an early stage of development. Reaching the next level of development will require strategic coordination between physicists, computer & information scientists, mathematicians, and engineers, in order to transition this technology from the laboratory to robust and scalable computations for practical problems, especially those of interest to the aeroscience and engineering community. This community has been relying on high-performance computing heavily and will surely want to be informed of the developments in QC. This survey introduces the background and current state of the art in QC, as well as its perceived opportunities and challenges.

Peyman Givi↗