Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MarCo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases

Intensity-modulated radiotherapy (IMRT) allowed the simultaneous delivery of different doses to different target volumes within a single fraction, an approach called simultaneous integrated boost (SIB). As consequence, the fraction dose to the boost volume can be increased while keeping low doses to the elective volumes, and the number of fractions and overall treatment time will be reduced, translating into better radiobiological effectiveness. In recent years, volumetric-modulated arc therapy (VMAT) has been shown to provide similar plan quality with respect to fixed-field IMRT but with large reduction in treatment time and monitor units (MUs) number. However, the feasibility of VMAT when used with SIB strategy has few investigations to date. We explored the potential of VMAT in a SIB strategy for complex cancer sites. A total of 15 patients were selected, including 5 head-and-neck, 5 high-risk prostate, and 5 rectal cancer cases. Both a double-arc VMAT and a 7-field IMRT plan were generated for each case using Oncentra MasterPlan treatment planning system for an Elekta Precise linac. Dosimetric indexes for targets and organs at risk (OARs) were compared based on dose-volume histograms. Conformity index, homogeneity index, and dose-contrast index were used for target analyses. The equivalent uniform doses and the normal tissue complication probabilities were calculated for main OARs. MUs number and treatment time were analyzed to score treatment efficiency. Pretreatment dosimetry was performed using 2-dimensional (2D)-array dosimeter. SIB-VMAT plans showed a high level of fluence modulation needed for SIB treatments, high conformal dose distribution, similar target coverage, and a tendency to improve OARs sparing compared with the benchmark SIB-IMRT plans. The median treatment times reduced from 13 to 20 minutes to approximately 5 minutes for all cases with SIB-VMAT, with a MUs reduction up to 22.5%. The 2D-array ion-chambers' measurements reported an agreement of more than 95% for a criterion of 3% to 3 mm. SIB-VMAT was able to combine the advantages of conventional SIB-IMRT with its highly conformal dose distribution and OARs sparing and the advantages of 3D-conformal radiotherapy with its fast delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom

In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three “boxes” are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This “in-house build” phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of dose recalculation vs dose deformation in a commercial platform for deformable image registration with a computational phantom

Deformable image registration (DIR) is an important tool for mapping both dose and contours of a new set of planning images when recurrent, that is, adaptive radiotherapy, or further treatment, that is, re-treatment, is required. The aim of this study was to evaluate the need for plan recalculation in deformed anatomies and to develop a reliable workflow for validating the DIR algorithm to be applied to dose warping such as dose accumulation (DA) for adaptive radiation therapy, and dose summation (DS) in the case of re-treatment. A set of 3 computational phantoms was developed to validate the application of B-Spline-based registrations for dose mapping among the various computed tomography image data sets. Two different versions were defined for each phantom to simulate clinical needs: adaptive radiotherapy and re-treatment; a DIR was performed to obtain a displacement vector field (DVF) for dose applications. Comparison of calculated and deformed doses was carried out by means of known markers inside the virtual phantoms. The differences were evaluated using a 3% dose index as acceptance criteria. A paired Wilcoxon signed-rank test was carried out to test the statistical significance of differences within the markers. Significant differences were only observed for the deformed dose in the DA test; no significant differences were observed for recalculated dose values in the DA and DS tests. The dose index is in accordance with these results. The warping dose process obtained by registering various sets of images was validated; a recalculation approach seems to be more accurate for DA purposes and image-guided adaptive radiation therapy (IGART) applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surprising olefin/paraffin separation performance recovery of highly aged carbon molecular sieve hollow fiber membranes by a super-hyperaging treatment

Carbon molecular sieve (CMS) hollow fibers derived from 6FDA 1 :BPDA 1 /DAM 2 , a well-studied polyimide precursor with attractive propylene/propane separation performance, were purposely treated to simulate long time aging under storage conditions. A simple, efficient post-aging thermal-treatment regeneration termed “super-hyperaging” is shown here to recover C 3 H 6 permeance with satisfactory C 3 H 6 /C 3 H 8 selectivity. A super-hyperaging temperature around 280 °C in air is shown to provide an optimum tradeoff in permeance and selectivity for highly aged samples. The regenerated CMS membrane displays performance well beyond the polymer permeance-selectivity tradeoff upper bound, and a hypothetical mechanism for the super-hyperaging recovery of aged CMS fibers is discussed in this work.

Recovery↗

Microbial assimilation of lignin-derived aromatic compounds and conversion to value-added products

Lignin is an abundant and sustainable source of aromatic compounds that can be converted to value-added products. However, lignin is underutilized, since depolymerization produces a complex mixture of aromatic compounds that is difficult to convert to a single product. Microbial conversion of mixed aromatic substrates provides a potential solution to this conversion challenge. Recent advances have expanded the range of lignin-derived aromatic substrates that can be assimilated and demonstrated efficient conversion via central metabolism to new potential products. Here, the development of additional non-model microbial hosts and genetic tools for these hosts have accelerated engineering efforts. However, yields with real depolymerized lignin are still low, and additional work will be required to achieve viable conversion processes.

59 BASIC BIOLOGICAL SCIENCES↗

Role of p-GaN layer thickness in the degradation of InGaN-GaN MQW solar cells under 405 nm laser excitation

GaN-based solar cells with InGaN multiple quantum wells (MQWs) are promising devices for application in space environment, concentrator solar systems, wireless power transmission and multi-junction solar cells. It is therefore important to understand their degradation kinetics when submitted to high-temperature and high-intensity stress. We submitted three samples of GaN-InGaN MQW solar cells with p-AlGaN electron-blocking-layer with different thickness of the p-GaN layer to constant power stress at 310 W/cm 2 , 175 °C for several hundred hours. The main degradation modes are a reduction of open-circuit voltage, short-circuit current, external quantum efficiency, power conversion efficiency and electroluminescence. In particular, we observed that a thinner p-GaN layer results in a stronger degradation observed on the cell operating parameters. The analysis of the dark I-V characteristics showed an increase in low-forward bias current and the analysis of electroluminescence showed a decrease in the electroluminescene emitted by the (forward biased) cell, as a consequence of stress. This work highlights that the cause of degradation is possibly related to a diffusion mechanism, which results in an increase of defect density in the active region. Finally, the impurities involved in the diffusion processes possibly originate from the p-side of the devices, therefore a thicker p-GaN layer reduces the amount of defects reaching the active region.

14 SOLAR ENERGY↗

Multidomain Convergence of Argonaute during RISC Assembly Correlates with the Formation of Internal Water Clusters

Despite the relevance of Argonaute proteins in RNA silencing, little is known about the structural steps of small RNA loading to form RNA-induced silencing complexes (RISCs). We report the 1.9 Å crystal structure of human Argonaute4 with guide RNA. Comparison with the previously determined apo structure of Neurospora crassa QDE2 revealed that the PIWI domain has two subdomains. Binding of guide RNA fastens the subdomains, thereby rearranging the active-site residues and increasing the affinity for TNRC6 proteins. We also identified two water pockets beneath the nucleic acid-binding channel that appeared to stabilize the mature RISC. Indeed, mutating the water-pocket residues of Argonaute2 and Argonaute4 compromised RISC assembly. Simulations predict that internal water molecules are exchangeable with the bulk solvent but always occupy specific positions at the domain interfaces. These results suggest that after guide RNA-driven conformational changes, water-mediated hydrogen-bonding networks tie together the converged domains to complete the functional RISC structure.

59 BASIC BIOLOGICAL SCIENCES↗

Depth-resolved residual stress analysis of thin coatings by a new FIB-DIC method

A new methodology for the measurement of depth sensitive residual stress profiles of thin coatings with sub-micrometer resolution is presented. The two step method consists of incremental focused ion beam (FIB) ring-core milling, combined with high-resolution in situ SEM-FEG imaging of the relaxing surface and a full field strain analysis by digital image correlation (DIC). The through-thickness profile of the residual stress can be obtained by comparison of the experimentally measured surface strain with finite element modeling using Schajer's integral method. In this work, a chromium nitride (CrN) CAE-PVD 3.0 {mu}m coating on steel substrate, and a gold MS-PVD 1.5 {mu}m on silicon were selected for the experimental implementation. Incremental FIB milling was conducted using an optimized milling strategy that produces minimum re-deposition over the sample surface. Results showed an average residual stress of {sigma} = -5.15 GPa in the CrN coating and {sigma} = +194 MPa in the Au coating. These values are in reasonable agreement with estimates obtained by other conventional techniques. The depth profiles revealed an increasing residual stress from surface to the coating/surface interface for both coatings. This observation is likely related to stress relaxation during grain growth, which was observed in microstructural cross sections, as predicted by existing models for structure-stress evolution in PVD coatings. A correlation between the observed stress gradients and the in-service mechanical behavior of the coatings is proposed. Finally, critical aspects of the technique and the influence of microstructure and elastic anisotropy on stress analysis are analyzed and discussed.

36 MATERIALS SCIENCE↗

NASICON-type Na 3 Fe 2 (PO 4 ) 3 as a low-cost and high-rate anode material for aqueous sodium-ion batteries

Aqueous sodium-ion batteries are attractive battery alternatives for stationary energy storage due to their inherently low cost and high safety. The development of advanced electrode materials with excellent performance and low cost is crucial for the success of aqueous Na-ion batteries. Albeit the high capacity and stable cycling of the leading anode of NaTi 2 (PO 4 ) 3 , the high price of titanium element and the low Na-insertion potential close to the hydrogen evolution reaction may plague its application. Here we introduced a NASICON-type Na 3 Fe 2 (PO 4 ) 3 as a promising anode alternative for aqueous Na-ion batteries. Synchrotron X-ray diffraction and spectroscopy confirm its phase and atomic structure. Electrochemical characterization and X-ray photoelectron spectroscopy reveal the reversible Na+ insertion in Na 3 Fe 2 (PO 4 ) 3 due to the Fe 3+ /Fe 2+ redox couple, which renders a specific capacity of ~60 mAh g -1 and excellent cycling of 1000 cycles at 10C rate. A Super high rate of 100C was also achieved for this anode with a capacity retention of 61% after 1000 cycles. In addition, the Na 3 Fe 2 (PO 4 ) 3 anode is paired with a Prussian white analogue of Na 2 Mn[Fe(CN) 6 ] into a full cell, exhibiting promising cell performance and material sustainability. Furthermore, our work underlines the importance of fabricating aqueous batteries on the basis of the Earth-abundant, cost-effective, and non-toxic elements.

25 ENERGY STORAGE↗

ENDF/B-VII.1 Nuclear Data for Science and Technology: Cross Sections, Covariances, Fission Product Yields and Decay Data

The ENDF/B-VII.1 library is our latest recommended evaluated nuclear data file for use in nuclear science and technology applications, and incorporates advances made in the five years since the release of ENDF/B-VII.0. These advances focus on neutron cross sections, covariances, fission product yields and decay data, and represent work by the US Cross Section Evaluation Working Group (CSEWG) in nuclear data evaluation that utilizes developments in nuclear theory, modeling, simulation, and experiment. The principal advances in the new library are: (1) An increase in the breadth of neutron reaction cross section coverage, extending from 393 nuclides to 423 nuclides; (2) Covariance uncertainty data for 190 of the most important nuclides, as documented in companion papers in this edition; (3) R-matrix analyses of neutron reactions on light nuclei, including isotopes of He, Li, and Be; (4) Resonance parameter analyses at lower energies and statistical high energy reactions for isotopes of Cl, K, Ti, V, Mn, Cr, Ni, Zr and W; (5) Modifications to thermal neutron reactions on fission products (isotopes of Mo, Tc, Rh, Ag, Cs, Nd, Sm, Eu) and neutron absorber materials (Cd, Gd); (6) Improved minor actinide evaluations for isotopes of U, Np, Pu, and Am (we are not making changes to the major actinides {sup 235,238}U and {sup 239}Pu at this point, except for delayed neutron data and covariances, and instead we intend to update them after a further period of research in experiment and theory), and our adoption of JENDL-4.0 evaluations for isotopes of Cm, Bk, Cf, Es, Fm, and some other minor actinides; (7) Fission energy release evaluations; (8) Fission product yield advances for fission-spectrum neutrons and 14 MeV neutrons incident on {sup 239}Pu; and (9) A new decay data sublibrary. Integral validation testing of the ENDF/B-VII.1 library is provided for a variety of quantities: For nuclear criticality, the VII.1 library maintains the generally-good performance seen for VII.0 for a wide range of MCNP simulations of criticality benchmarks, with improved performance coming from new structural material evaluations, especially for Ti, Mn, Cr, Zr and W. For Be we see some improvements although the fast assembly data appear to be mutually inconsistent. Actinide cross section updates are also assessed through comparisons of fission and capture reaction rate measurements in critical assemblies and fast reactors, and improvements are evident. Maxwellian-averaged capture cross sections at 30 keV are also provided for astrophysics applications. We describe the cross section evaluations that have been updated for ENDF/B-VII.1 and the measured data and calculations that motivated the changes, and therefore this paper augments the ENDF/B-VII.0 publication 'ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and Technology,' Nuclear Data Sheets 107, 2931 (2006).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation and Testing of ENDF/B-VII Decay Data

The nuclear decay library developed for the ORIGEN code was upgraded from ENDF/B-VI.8 to -VII.0 and released in the SCALE nuclear modeling and simulation code system in 2011. Experience with the ENDF/B-VII.0 library identified serious errors and performance issues in the evaluated decay sublibrary. Initially, errors were identified in the decay scheme for the 238U series, leading to large discrepancies in the gamma emission rate for uranium. Further testing of the fission product decay data revealed significant performance issues with ENDF/B-VII.0 relative to the previous release of ENDF/B-VI. To address the performance issues, the decay data library in SCALE was upgraded to ENDF/B-VII.1 and released as an update for users in 2013. This paper describes the practical impact of the ENDF/B-VII.0 decay data performance issues on common code applications, and the validation and testing performed on the updated ORIGEN libraries developed from the ENDF/B-VII.1 sublibrary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural Determinants of Cadherin-23 Function in Hearing and Deafness

The hair-cell tip link, a fine filament directly conveying force to mechanosensitive transduction channels, is composed of two proteins, protocadherin-15 and cadherin-23, whose mutation causes deafness. However, their molecular structure, elasticity, and deafness-related structural defects are unknown. We present crystal structures of the first and second extracellular cadherin repeats of cadherin-23. Overall, structures show typical cadherin folds, but reveal an elongated N terminus that precludes classical cadherin interactions and contributes to an N-terminal Ca{sup 2+}-binding site. The deafness mutation D101G, in the linker region between the repeats, causes a slight bend between repeats and decreases Ca{sup 2+} affinity. Molecular dynamics simulations suggest that cadherin-23 repeats are stiff and that either removing Ca{sup 2+} or mutating Ca{sup 2+}-binding residues reduces rigidity and unfolding strength. The structures define an uncharacterized cadherin family and, with simulations, suggest mechanisms underlying inherited deafness and how cadherin-23 may bind with itself and with protocadherin-15 to form the tip link.

36 MATERIALS SCIENCE↗