Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Interaction Between the Broad-Lined Type Ic Supernova 2012ap and Carriers of Diffuse Interstellar Bands

The diffuse interstellar bands (DIBs) are absorption features observed in optical and near-infrared spectra that are thought to be associated with carbon-rich polyatomic molecules in interstellar gas. However, because the central wavelengths of these bands do not correspond with electronic transitions of any known atomic or molecular species, their nature has remained uncertain since their discovery almost a century ago. Here we report on unusually strong DIBs in optical spectra of the broad- lined Type Ic supernova SN2012ap that exhibit changes in equivalent width over short (. 30 days) timescales. The 4428 A and 6283 A DIB features get weaker with time, whereas the 5780 A feature shows a marginal increase. These nonuniform changes suggest that the supernova is interacting with a nearby source of the DIBs and that the DIB carriers possess high ionization potentials, such as small cations or charged fullerenes. We conclude that moderate-resolution spectra of supernovae with DIB absorptions obtained within weeks of outburst could reveal unique information about the mass-loss environment of their progenitor systems and provide new constraints on the properties of DIB carriers.

broad↗

On the Detectability of CO Molecules in the Interstellar Medium via X-Ray Spectroscopy

We present a study of the detectability of CO molecules in the Galactic interstellar medium using high-resolution X-ray spectra obtained with the XMM-Newton Reflection Grating Spectrometer. We analysed 10 bright low mass X-ray binaries (LMXBs) to study the CO contribution in their line of sights. A total of 25 observations were fitted with the ISMabs X-ray absorption model which includes photoabsorption cross-sections for Oi, Oii, Oiii and CO. We performed a Monte Carlo (MC) simulation analysis of the goodness of fit in order to estimate the significance of the CO detection. We determine that the statistical analysis prevents a significant detection of CO molecular X-ray absorption features, except for the lines of sight towards XTE J1718-330 and 4U 1636-53. In the case of XTE J1817-330, this is the first report of the presence of CO along its line of sight. Our results reinforce the conclusion that molecules have a minor contribution to the absorption features in the O K-edge spectral region. We estimate a CO column density lower limit to perform a significant detection with XMM-Newton of N(CO) greater than 6 x 10(exp 16) per sq cm for typical exposure times.

ISM: structure↗

The OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS): Spectral Maps of the Asteroid Bennu

The OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) is a point spectrometer covering the spectral range of 0.4 to 4.3 microns (25,000-2300 cm−1). Its primary purpose is to map the surface composition of the asteroid Bennu, the target asteroid of the OSIRIS-REx asteroid sample return mission. The information it returns will help guide the selection of the sample site. It will also provide global context for the sample and high spatial resolution spectra that can be related to spatially unresolved terrestrial observations of asteroids. It is a compact, low-mass (17.8 kg), power efficient (8.8 W average), and robust instrument with the sensitivity needed to detect a 5% spectral absorption feature on a very dark surface (3% reflectance) in the inner solar system (0.89-1.35 AU). It, in combination with the other instruments on the OSIRIS-REx Mission, will provide an unprecedented view of an asteroid's surface.

Reuter, D. C.↗

The Effect of Physically Based Ice Radiative Processes on Greenland Ice Sheet Albedo and Surface Mass Balance in E3SM

Abstract A significant portion of surface melt on the Greenland Ice Sheet (GrIS) is due to dark ice regions in the ablation zone, where solar absorption is influenced by the physical properties of the ice, light absorbing constituents (LACs), and the overlying crustal surface or melt ponds. Earth system models (ESMs) typically prescribe the albedo of ice surfaces as a constant value in the visible and near‐infrared spectral regions. This work advances ESM ice radiative transfer modeling by (a) incorporating a physically based radiative transfer model (SNow, ICe and Aerosol Radiation model Adding‐Doubling Version 4; SNICAR‐ADv4) into the Energy Exascale Earth System Model (E3SM), (b) determining spatially and temporally varying bare ice physical properties over the GrIS ablation zone from satellite observations to inform SNICAR‐ADv4, and (c) assessing the impacts on simulated GrIS albedo and surface mass balance associated with modeling of more realistic bare ice albedo. GrIS‐wide bare ice albedo in E3SMv2 is overestimated by ∼4% in the visible and ∼7% in the near‐infrared wavelengths compared to the Moderate Resolution Imaging Spectroradiometer. Our bare ice physical property retrieval method found that LACs, ice crustal surfaces, and melt ponds reduce visible albedo by 30% in the bare ice region of the GrIS ablation zone. The realistic bare ice albedo reduces surface mass balance by ∼145 Gt, or 0.4 mm of sea‐level equivalent between 2000 and 2021 compared to the default E3SM. This work highlights the importance of simulating bare ice albedo accurately and realistically to improve our ability to quantify changes in the GrIS surface mass and radiative energy budgets.

58 GEOSCIENCES↗

Dependence of Dynamic Modeling Accuracy on Sensor Measurements, Mass Properties, and Aircraft Geometry

The NASA Generic Transport Model (GTM) nonlinear simulation was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of identified parameters in mathematical models describing the flight dynamics and determined from flight data. Measurements from a typical flight condition and system identification maneuver were systematically and progressively deteriorated by introducing noise, resolution errors, and bias errors. The data were then used to estimate nondimensional stability and control derivatives within a Monte Carlo simulation. Based on these results, recommendations are provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using additional flight conditions and parameter estimation methods, as well as a nonlinear flight simulation of the General Dynamics F-16 aircraft, were compared with these recommendations

Grauer, Jared A.↗

Jet energy scale and resolution measured in proton–proton collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

Jet energy scale and resolution measurements with their associated uncertainties are reported for jets using 36–81 fb -1 of proton–proton collision data with a centre-of-mass energy of √s=13 TeV collected by the ATLAS detector at the LHC. Jets are reconstructed using two different input types: topo-clusters formed from energy deposits in calorimeter cells, as well as an algorithmic combination of charged-particle tracks with those topo-clusters, referred to as the ATLAS particle-flow reconstruction method. The anti-k t jet algorithm with radius parameter R=0.4 is the primary jet definition used for both jet types. This result presents new jet energy scale and resolution measurements in the high pile-up conditions of late LHC Run 2 as well as a full calibration of particle-flow jets in ATLAS. Jets are initially calibrated using a sequence of simulation-based corrections. Next, several in situ techniques are employed to correct for differences between data and simulation and to measure the resolution of jets. The systematic uncertainties in the jet energy scale for central jets (|η|<1.2) vary from 1% for a wide range of high-p T jets (250 T <2000 GeV), to 5% at very low p T (20 GeV) and 3.5% at very high p T (>2.5 TeV). The relative jet energy resolution is measured and ranges from (24±1.5)% at 20 GeV to (6±0.5)% at 300 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fusion of laser and image sensory data for 3-D modeling of the free navigation space

A fusion technique which combines two different types of sensory data for 3-D modeling of a navigation space is presented. The sensory data is generated by a vision camera and a laser scanner. The problem of different resolutions for these sensory data was solved by reduced image resolution, fusion of different data, and use of a fuzzy image segmentation technique.

Mass, M.↗

An Iterated Global Mascon Solution with Focus on Land Ice Mass Evolution

Land ice mass evolution is determined from a new GRACE global mascon solution. The solution is estimated directly from the reduction of the inter-satellite K-band range rate observations taking into account the full noise covariance, and formally iterating the solution. The new solution increases signal recovery while reducing the GRACE KBRR observation residuals. The mascons are estimated with 10-day and 1-arc-degree equal area sampling, applying anisotropic constraints for enhanced temporal and spatial resolution of the recovered land ice signal. The details of the solution are presented including error and resolution analysis. An Ensemble Empirical Mode Decomposition (EEMD) adaptive filter is applied to the mascon solution time series to compute timing of balance seasons and annual mass balances. The details and causes of the spatial and temporal variability of the land ice regions studied are discussed.

Luthcke, S. B.↗

3D optical diagnostics for explosively driven deformation and fragmentation

High-speed, optical imaging diagnostics are presented for three-dimensional (3D) quantification of explosively driven metal fragmentation. At early times after detonation, Digital Image Correlation (DIC) provides non-contact measures of 3D case velocities, strains, and strain rates, while a proposed stereo imaging configuration quantifies in-flight fragment masses and velocities at later times. Experiments are performed using commercially obtained RP-80 detonators from Teledyne RISI, which are shown to create a reproducible fragment field at the benchtop scale. DIC measurements are compared with 3D simulations, which have been ‘leveled’ to match the spatial resolution of DIC. Overall, results demonstrate improved ability to identify predicted quantities-of-interest that fall outside of measurement uncertainty and shot-to-shot variability. Similarly, video measures of fragment trajectories and masses allow rapid experimental repetition and provide correlated fragment size-velocity measurements. Measured and simulated fragment mass distributions are shown to agree within confidence bounds, while some statistically meaningful differences are observed between the measured and predicted conditionally averaged fragment velocities. Together these techniques demonstrate new opportunities to improve future model validation.

42 ENGINEERING↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗

Structured ionized winds shooting out from a quasar at relativistic speeds

Evidence indicates that supermassive black holes (SMBHs) exist at the centres of most galaxies. Their mass correlates with the galactic bulge mass, suggesting a coevolution with their host galaxies, most likely through powerful winds. X-ray observations have detected highly ionized winds outflowing at sub-relativistic speeds from the accretion disks around SMBHs. However, the limited spectral resolution of present X-ray instruments has left the physical structure and location of the winds poorly understood, hindering accurate estimates of their kinetic power. Here, in this study, the first X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the luminous quasar PDS 456 is reported. The high-resolution spectrometer Resolve aboard XRISM enabled the discovery of five discrete velocity components outflowing at 20–30% of the speed of light. This demonstrates that the wind structure is highly inhomogeneous, which probably consists of up to a million clumps. The mass outflow rate is estimated to be 60–300 solar masses per year, with the wind kinetic power exceeding the Eddington luminosity limit. Compared with the galaxy-scale outflows, the kinetic power is more than three orders of magnitude larger, whereas the momentum flux is ten times larger. These estimates disfavour both energy-driven and momentum-driven outflow models. This suggests that such wind activity occurs in less than 10% of the quasar phase and/or that its energy/momentum is not efficiently transferred to the galaxy-scale outflows owing to the clumpiness of the wind and the interstellar medium.

Audard, Marc [Univ. of Geneva, Versoix (Switzerlan↗

Online collection of LC effluent as droplets for automatic injection into ICP-MS

A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.

GPEC↗

Integrated Pest Management (IPM) for Early Detection Algal Crop Protection. Final Report

During large-scale, outdoor algal biomass growth, production strain(s) are subject to attack by pathogens, predators, and non-productive competitors, compromising the biomass yield. The project team at UCSD developed and demonstrated the effectiveness of Volatile Organic Compound, VOC, analysis via mass spectrometry (MS) as an early detection system for the presence of production algal ponds infection. The MS detection can then trigger high-resolution melt analysis (HRMA) and enhanced quantitative PCR (qPCR) to identify predatory or pathogenic species precisely. This study gathered the foundational data informing how wholly automated systems monitor the health of production ponds. By detecting the presence of low molecular weight VOCs in the air space above ponds, the instrument was able to mimic “sniffing” the health of the algae pond. This early warning system will be free growers from time-consuming and costly regular surveillance of ponds with the current techniques, such as qPCR and flow-cam assays, which are slower, less sensitive, and not easily fully automated, resulting in increased production efficiency through the reduction of crop loss. This project demonstrated that Chemical Ionization Mass Spectrometry, CIMS, could serve as a real-time monitor of ponds health tracking up to 100 different VOCs simultaneously for continuous periods up to 60 days without interruption, signaling infection within an algal crop 24 to 36 hours prior to techniques such as qPCR and microscopy. While mass spectrometry is an expensive tool, this simple VOC sampling system proved not only to be sensitive and robust but could to multiplexed to monitor several ponds, lowering the overall cost serially. This technology demonstrated a reduction in biomass production cost by approximately 50% compared to growers not employing any detection methodology.

09 BIOMASS FUELS↗

Binary Black Hole Mergers and Recoil Kicks

Recent developments in numerical relativity have made it possible to follow reliably the coalescence of two black holes from near the innermost stable circular orbit to final ringdown. This opens up a wide variety of exciting astrophysical applications of these simulations. Chief among these is the net kick received when two unequal mass or spinning black holes merge. The magnitude of this kick has bearing on the production and growth of supermassive black holes during the epoch of structure formation, and on the retention of black holes in stellar clusters. Here we report the first accurate numerical calculation of this kick, for two nonspinning black holes in a 1.5:1 mass ratio, which is expected based on analytic considerations to give a significant fraction of the maximum possible recoil. We have performed multiple runs with different initial separations, orbital angular momenta, resolutions, extraction radii, and gauges. The full range of our kick speeds is 86-116 kilometers per second, and the most reliable runs give kicks between 86 and 97 kilometers per second. This is intermediate between the estimates from two recent post-Newtonian analyses and suggests that at redshifts z greater than 10, halos with masses less than 10(exp 9) M(sub SUN) will have difficulty retaining coalesced black holes after major mergers.

Centrella, Joan↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Isotopic analysis of plutonium measured with very thick absorbers and high-granularity spectra

FRAM is LANL-designed software designed to extract plutonium and uranium isotopic information from gamma ray spectra. This is an important capability for NEST and STAB; however, FRAM performance has been poor when applied to field data collected in these programs. FRAM Version 5 (commercially available) was fine-tuned and validated for laboratory quality measurements but not for measurements of the high-mass and heavily shielded SNM items encountered in NEST. FRAM is untested for spectra collected with high-granularity lower resolution instruments such as the new 8-MeV Detective-X favored by STAB or the new custom electrocooled systems coming into use for NEST. FRAM Version 6.1 (unreleased) has improvements in physics capabilities, and parameter sets may be adapted that are more specific to NEST and STAB, which is what we have attempted for this assignment. Thick shielding attenuates gamma rays profoundly, especially those at low energy, making them too weak to be measured. The missing low-energy peaks force the analysis to employ only the highest-energy peaks. We adapted FRAM 6.1 for analysis of plutonium spectra obtained with very thick Pb filters (a surrogate for NEST-type configurations). New parameter sets employing only very high energy peaks were created for the analysis. High granularity and low resolution make deconvolution of the 600-keV region particularly challenging, and we have worked to optimally extract information from this region. The results shown in this paper give high confidence that we are on the right track. We used a combination of real and synthetically-modified data. Remaining work includes testing the new software and parameters against genuine data collected with Detective-X and new NEST systems, but such datasets at the moment are unavailable. It also remains to develop and test parameter sets specific to uranium and the new detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Cadmium alters whole animal ionome and promotes the re-distribution of iron in intestinal cells of Caenorhabditis elegans

The chronic exposure of humans to the toxic metal cadmium (Cd), either occupational or from food and air, causes various diseases, including neurodegenerative conditions, dysfunction of vital organs, and cancer. While the toxicology of Cd and its effect on the homeostasis of biologically relevant elements is increasingly recognized, the spatial distribution of Cd and other elements in Cd toxicity-caused diseases is still poorly understood. Here, we use Caenorhabditis elegans as a non-mammalian multicellular model system to determine the distribution of Cd at the tissue and cellular resolution and its effect on the internal levels and the distribution of biologically relevant elements. Using inductively coupled plasma-mass spectrophotometry (ICP-MS), we show that exposure of worms to Cd not only led to its internal accumulation but also significantly altered the C. elegans ionome. Specifically, Cd treatment was associated with increased levels of toxic elements such as arsenic (As) and rubidium (Rb) and a decreased accumulation of essential elements such as zinc (Zn), copper (Cu), manganese (Mn), calcium (Ca), cobalt (Co) and, depending on the Cd-concentration used in the assay, iron (Fe). We regarded these changes as an ionomic signature of Cd toxicity in C. elegans. We also show that supplementing nematode growth medium with Zn but not Cu, rescues Cd toxicity and that mutant worms lacking Zn transporters CDF-1 or SUR-7, or both are more sensitive to Cd toxicity. Finally, using synchrotron X-Ray fluorescence Microscopy (XRF), we showed that Cd significantly alters the spatial distribution of mineral elements. The effect of Cd on the distribution of Fe was particularly striking: while Fe was evenly distributed in intestinal cells of worms grown without Cd, in the presence of Cd, Fe, and Cd co-localized in punctum-like structures in the intestinal cells. Together, this study advances our understanding of the effect of Cd on the accumulation and distribution of biologically relevant elements. Considering that C. elegans possesses the principal tissues and cell types as humans, our data may have important implications for future therapeutic developments aiming to alleviate Cd-related pathologies in humans.

59 BASIC BIOLOGICAL SCIENCES↗

Vibrationally inelastic low-energy CO/+/ - Ar collisions.

Examination of relative differential cross sections for inelastic scattering of CO(+) by Ar with a high-resolution ion-beam apparatus in which a CO(+) beam interacts with a neutral-Ar beam, and the energy, mass, and angular distribution of scattered ions are measured. Maxima in the inelastic energy-loss spectra occur at energies corresponding to CO(+) spectroscopic vibrational spacings. Weakly inelastic processes are observed below the threshold for vibrational energy loss, corresponding to rotational excitation with the relative importance of rotational transitions increasing with decreasing energy and scattering angle.

Petty, F.↗