Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Development of a flexible optical fiber based high resolution integrated PET/MRI system

Purpose: The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET/MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce the problem, the authors newly developed flexible optical fiber bundle based block detectors and employed them for a high resolution integrated PET/MRI system. Methods: The flexible optical fiber bundle used 0.5 mm diameter, 80 cm long double clad fibers which have dual 12 mm Multiplication-Sign 24 mm rectangular inputs and a single 24 mm Multiplication-Sign 24 mm rectangular output. In the input surface, LGSO scintillators of 0.025 mol.% (decay time: {approx}31 ns: 0.9 mm Multiplication-Sign 1.3 mm Multiplication-Sign 5 mm) and 0.75 mol.% (decay time: {approx}46 ns: 0.9 mm Multiplication-Sign 1.3 mm Multiplication-Sign 6 mm) were optically coupled in depth direction to form depth-of-interaction detector, arranged in 11 Multiplication-Sign 13 matrix and optically coupled to the fiber bundle. The two inputs of the bundle are bent for 90 Degree-Sign , bound to one, and are optically coupled to a Hamamatsu 1-in. square position sensitive photomultiplier tube. Results: Light loss due to the fiber bundle could be reduced and the performance of the block detectors was improved. Eight optical fiber based block detectors (16 LGSO blocks) were arranged in a 56 mm diameter ring to form a PET system. Spatial resolution and sensitivity were 1.2 mm full-width at half-maximum and 1.2% at the central field-of-view, respectively. Sensitivity change was less than 1% for 2 Degree-Sign C temperature changes. This PET system was integrated with a 0.3 T permanent magnet MRI system which has 17 cm diameter hole at the yoke area for insertion of the PET detector ring. There was no observable interference between PET and MRI. Simultaneous imaging of PET and MRI was successfully performed for small animal studies. Conclusions: The authors confirmed that the developed high resolution PET/MRI system is promising for molecular imaging research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The chiral magnetic effect: Beam-energy and system-size dependence

We consider the energy dependence of the local P and CP violation in AuAu and CuCu collisions over a large energy range within a simple phenomenological model. It is expected that at LHC the chiral magnetic effect will be about 20 times weaker than at RHIC. At lower energy range this effect should vanish sharply at energy somewhere above the top SPS one. To elucidate CME background effects a transport model including magnetic field evolution is put forward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic properties of the low-dimensional Ba M 2 Si 2 O 7 system ( M = Cu , Co , Mn )

Here, we explored the magnetic properties of the low-dimensional Ba M 2 Si 2 O 7 (M = Cu, Co, and Mn) system using both experimental measurements and theoretical calculations. Magnetization, specific heat, and single crystal neutron diffraction measurements have been performed on single crystal Ba M 2 Si 2 O 7 . The spin structure was determined and a magnetic phase diagram with applied field along the b axis was constructed, which contains a spin flop transition around 6 T. Magnetization and specific heat measurements confirmed the presence of weak ferromagnetism in Ba M 2 Si 2 O 7 . Furthermore, we performed local-spin density approximation with on-site Coulomb energy (LSDA+U) calculations for the Ba M 2 Si 2 O 7 (M = Cu, Co, and Mn) system. Due to the first-principles calculations, the origin of the magnetic differences of the three materials is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE MAGNETIC FIELD IN THE CLASS 0 PROTOSTELLAR DISK OF L1527

We present subarcsecond (∼0.''35) resolved observations of the 1.3 mm dust polarization from the edge-on circumstellar disk around the Class 0 protostar L1527. The inferred magnetic field is consistent with a dominantly toroidal morphology; there is no significantly detected vertical poloidal component to which observations of an edge-on disk are most sensitive. This suggests that angular momentum transport in Class 0 protostars (when large amounts of material are fed down to the disk from the envelope and accreted onto the protostar) is driven mainly by magnetorotational instability rather than magnetocentrifugal winds at 50 AU scales. In addition, with the data to date there is an early, tentative trend that R > 30 AU disks have so far been found in Class 0 systems with average magnetic fields on the 1000 AU scale strongly misaligned with the rotation axis. The absence of such a disk in the aligned case could be due to efficient magnetic braking that disrupts disk formation. If this is the case, this implies that candidate Class 0 disk systems could be identified by the average magnetic field direction at ∼1000 AU spatial scales.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-H-BRA-02: The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System

Purpose: To develop a method for isolating the MRI magnetic field from field-sensitive linear accelerator components at distances close to isocenter. Methods: A MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. In order to accomplish this, the magnetron, port circulator, radiofrequency waveguide, gun driver, and linear accelerator needed to be placed in locations with low magnetic fields. The system was also required to be compact, so moving these components far from the main magnetic field and isocenter was not an option. The magnetic field sensitive components (exclusive of the waveguide) were placed in coaxial steel sleeves that were electrically and mechanically isolated and whose thickness and placement were optimized using E&M modeling software. Six sets of sleeves were placed 60° apart, 85 cm from isocenter. The Faraday effect occurs when the direction of propagation is parallel to the magnetic RF field component, rotating the RF polarization, subsequently diminishing RF power. The Faraday effect was avoided by orienting the waveguides such that the magnetic field RF component was parallel to the magnetic field. Results: The magnetic field within the shields was measured to be less than 40 Gauss, significantly below the amount needed for the magnetron and port circulator. Additional mu-metal was employed to reduce the magnetic field at the linear accelerator to less than 1 Gauss. The orientation of the RF waveguides allowed the RT transport with minimal loss and reflection. Conclusion: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of creating low magnetic field environments for the magnetic-field sensitive components, has been solved. The measured magnetic fields are sufficiently small to enable system integration. This work supported by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Intricate Magnetic Landscape in Antiferromagnetic Kagome Metal TbTi 3 Bi 4 and Interplay with Ln 2– x Ti 6+ x Bi 9 (Ln: Tb···Lu) Shurikagome Metals

Here we present the discovery and characterization of the kagome metal TbTi 3 Bi 4 in tandem with a new series of compounds, the Ln 2–x Ti 6+x Bi 9 (Ln: Tb–Lu) shurikagome metals. We previously reported on the growth of the LnTi 3 Bi 4 (Ln: La–Gd 3+ , Eu 2+ , Yb 2+ ) family, a chemically diverse and exfoliable series of kagome metals with complex and highly anisotropic magnetism. However, unlike the La–Gd analogs, TbTi 3 Bi 4 cannot be synthesized by our previous methodology due to phase competition with crystals of Ln 2–x Ti 6+x Bi 9 (x ~ 1.7–1.2). Here we discuss the phase competition between the LnTi 3 Bi 4 and Ln 2–x Ti 6+x Bi 9 families, helping to frame the difficulty in synthesizing LnTi 3 Bi 4 compounds with small Ln species and providing a strategy to circumvent the formation of Ln 2–x Ti 6+x Bi 9 . Detailed characterization of the magnetic and electronic transport properties on single crystals of TbTi 3 Bi 4 reveals a highly complex landscape of magnetic phases arising from an antiferromagnetic ground state. A series of metamagnetic transitions creates at least 5 unique magnetic phase pockets, including a 1/3 and 2/3 magnetization plateau. Further, the system exhibits an intimate connection between the magnetism and magnetotransport, exhibiting sharp switching from positive (+40%) to negative magnetoresistance (–50%). Like the LnTi 3 Bi 4 kagome metals, the Ln 2–x Ti 6+x Bi 9 family exhibits quasi-2D networks of titanium and chains of rare earth. Finally, we present the structures and some basic magnetic properties of the Ln 2–x Ti 6+x Bi 9 family alongside our characterization of the newly discovered TbTi 3 Bi 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The XY model with Dzyaloshinskii-Moriya interaction

One can get spin-orbit interaction of the magnetic ions, besides the strong Heisenberg interaction, known as the Dzyaloshinskii-Moriya (DM) interaction. We show the effect of the DM interaction on the excitation spectrum. We also show here the magnetic Susceptibility and ferroelectric polarization of the system in a longitudinal magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetism and magnetoelastic effect in the two-dimensional van der Waals multiferroic CuCrP 2 ⁢S 6

Here, we report a magnetic and neutron diffraction study on the ground state magnetism and field evolution of single-crystal van der Waals multiferroic CuCrP 2 ⁢S 6 . The ordered moments align along the 𝑏 axis in the "𝐴-type" antiferromagnetic configuration with a spin-flop transition along the same direction. Field application along 𝑎 introduces a smooth transition to a fully polarized ferromagnetic state via in-plane spin rotation. These findings resolve the ambiguity of the ground state magnetization direction in CuCrP 2 ⁢S 6 and uncover its field responses, providing a firm basis for future magnetoelectric study. A magnetoelastic coupling effect connecting the interlayer spacing and the magnetic order was further revealed, highlighting the out-of-plane strain as an effective control knob for tuning magnetism both in this system and in related van der Waals magnets.

Guo, Jiasen [Oak Ridge National Laboratory (ORNL),↗

Impact of nanostructuring on the magnetic and magnetocaloric properties of microscale phase-separated La 5/8–y Pr y Ca 3/8 MnO₃ manganites

Bulk manganites of the form La 5/8–y Pr y Ca 3/8 MnO₃ (LPCMO) exhibit a complex phase diagram due to coexisting charge-ordered antiferromagnetic (CO/AFM), charge-disordered paramagnetic (PM), and ferromagnetic (FM) phases. Because phase separation in LPCMO occurs on the microscale, reducing particle size to below this characteristic length is expected to have a strong impact on the magnetic properties of the system. Through a comparative study of the magnetic and magnetocaloric properties of single-crystalline (bulk) and nanocrystalline LPCMO (y=3/8) we show that the AFM, CO, and FM transitions seen in the single crystal can also be observed in the large particle sizes (400 and 150 nm), while only a single PM to FM transition is found for the small particles (55 nm). Magnetic and magnetocaloric measurements reveal that decreasing particle size affects the balance of competing phases in LPCMO and narrows the range of fields over which PM, FM, and CO phases coexist. The FM volume fraction increases with size reduction, until CO is suppressed below some critical size, ~100 nm. With size reduction, the saturation magnetization and field sensitivity first increase as long-range CO is inhibited, then decrease as surface effects become increasingly important. The trend that the FM phase is stabilized on the nanoscale is contrasted with the stabilization of the charge-disordered PM phase occurring on the microscale, demonstrating that in terms of the characteristic phase separation length, a few microns and several hundred nanometers represent very different regimes in LPCMO.

Bingham, N. S.↗

SU-E-T-594: Preliminary Active Scanning Results of KHIMA

Purpose: To verify the design criteria on heavy ion beam irradiation, developing a proto type active scanning system was purposed. The active scanning system consists of scanning magnet, power supplies, beam monitors, energy modulation system, and irradiation control system. Methods: Each components of the active scanning system was designed for carbon beam first. For the fast ramping a laminated yoke was purposed. To measure incoming dose and profile, a plate and strip type of ion chambers were designed. Also, ridge filter and range shifter was manufactured. And, the scanning system was modified to adopt 45 MeV of proton beam because of the absence of carbon ion beam in Korea. The system was installed in a beam line at MC-50, KIRAMS. Also, the irradiation control system and planning software was provided. Results: The scanning experiment was performed by drawing KHIMA logo on GaF film. The logo was scanned by 237 scanning points through time normalized intensity modulation. Also, a grid points scanning was performed to measure the scanning resolution and intensity resolution. Conclusion: A prototype active scanning system was successfully designed and manufactured. Also, an initial experiment to print out a drawing on GaF film through the scanning system was completed. More experiments would be required to specify the system performance.

60 APPLIED LIFE SCIENCES↗

Topological Materials with Complex Long-Range Order

The overarching vision of this proposal is to understand exotic metallic behavior in frustrated quantum magnets. This problem is at the core of understanding a number of mysteries in the study of itinerant magnetism, and of high temperature superconductivity. The central challenge is that magnetic order is generally understood by localized magnetic moments. In these systems the mobile electrons form an ordered magnetic state, sometime breaking sharp symmetry, sometimes forming incommensurate order, and other times forming a spin liquid. The present research focuses on finding complex magnets that are in close proximity to a sea of metallic, itinerant electrons.

36 MATERIALS SCIENCE↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical trapping and manipulation of single particles for MDP

This two-year project, conducted under Grant Number DE-SC0021030, focused on the development and application of advanced optical trapping and manipulation technologies to study magnetized dusty plasma (MDP) systems and enhance diagnostic capabilities at the Magnetized Dusty Plasma Experiment (MDPX) facility at Auburn University. The central objective was to enable precise, non-invasive control and measurement of single particles within plasma environments, thereby addressing key limitations in existing plasma diagnostic techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of guide field on magnetic reconnection during island coalescence

A number of studies have considered how the rate of magnetic reconnection scales in large and weakly collisional systems by the modelling of long reconnecting current sheets. However, this set-up neglects both the formation of the current sheet and the coupling between the diffusion region and a larger system that supplies the magnetic flux. Recent studies of magnetic island merging, which naturally include these features, have found that ion kinetic physics is crucial to describe the reconnection rate and global evolution of such systems. In this paper, the effect of a guide field on reconnection during island merging is considered. In contrast to the earlier current sheet studies, we identify a limited range of guide fields for which the reconnection rate, outflow velocity, and pile-up magnetic field increase in magnitude as the guide field increases. The Hall-MHD fluid model is found to reproduce kinetic reconnection rates only for a sufficiently strong guide field, for which ion inertia breaks the frozen-in condition and the outflow becomes Alfvénic in the kinetic system. The merging of large islands occurs on a longer timescale in the zero guide field limit, which may in part be due to a mirror-like instability that occurs upstream of the reconnection region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of compact linear accelerator in KBSI

The compact linear accelerator using a 28 GHz ECRIS is under construction in KBSI, South Korea. The main capability of this facility is the production of fast neurons for the neutron radiography. The designing of a superconducting magnet, microwave transmission system, beam extraction, and plasma chamber of ECRIS were finished. The nominal axial design fields of the magnets are 3.6 T at injection and 2.2 T at extraction; the nominal radial design field strength at the plasma chamber wall is 2.1 T. We already installed 10 kW, 28 GHz gyrotron, and tested a microwave power from gyrotron using a dummy load. The current status will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Artificial spin ice phase-change memory resistors

Abstract We present a proposal for realization of an electrical memory reminiscent of a memristor in connected Kagome artificial spin ice. We show that current flowing through the system alters the magnetic ensemble, which in turns controls the overall resistance thus leaving memory of current passage in the system. This introduces a current-dependent effect for a dynamic resistive state. We simulate a spin-induced thermal phase-change mechanism, and an athermal domain-wall spin inversion. In both cases we observe electrical memory behavior with an I – V hysteretic pinched loop, typical of memristors. These results can be extended to the more complex geometries in which artificial spin ice can be designed to engineer the hysteresis curve.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAGNETIC FIELD MAPPING OF A LARGE-GRAIN 1.3 GHz SINGLE-CELL CAVITY

A new magnetic field mapping system for 1.3 GHz single- cell cavities was developed in order to reveal the impact of ambient magnetic field and temperature gradients during cool-down on the flux trapping phenomenon. Measurements were done at 2 K for different cool-down conditions of a large-grain cavity before and after 120 °C bake. The fraction of applied magnetic field trapped in the cavity walls was ? 50% after slow cool-down and ? 20% after fast cool-down. The results showed a weak correlation between between trapped flux locations and hot-spots causing the high-field Q-slope. The results also showed an increase of the trapped flux at the quench location, after quenching, and a local redistribution of trapped flux with increasing RF field.

Ciovati, Gianluigi↗