Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

The Corrected Distortion model for Lagrangian spray simulation of transcritical fuel injection

In this work, we present a detailed implementation and validation of the droplet modeling framework proposed by Dahms and Oefelein (2016) into the engine commercial CFD software CONVERGE using the User Defined Function (UDF) interface. The model accounts for the nonlinear deformation and oscillation experienced by liquid spray droplet injected into high pressure and temperature. Lagrangian spray simulations of Engine Combustion Network (ECN) Spray A are performed. Model validation against standard experimental measurements of liquid velocity, vapor mixture fraction is conducted. To perform more rigorous model validation, new experimental measurements based on Diffused Back Illumination (DBI) are introduced. The new measurements are processed for Projected Liquid Volume (PLV), which offers as close as possible one-to-one model validation for liquid penetration while offering new insights into the spray physics. Comparison with a One-D model based on adiabatic mixing theory by Siebers (1999) and Desantes et al. (2007) are also conducted. Through these model validation exercises, it is shown that the new framework improves liquid-phase penetration predictions, following a tendency for enhanced evaporation, compared to the standard approach for both Reynolds Average Navier Stokes (RANS) and Large Eddy Simulation (LES). Additionally, at the liquid length, maximum mixture fraction values predicted by the new approach are in good agreement those of an adiabatic mixing model. Qualitative analysis of the spray behaviors during the early stage of the injection process reveals that the proposed framework predicts significant increase in droplet evaporation rate with lower drop drag compared to the current standard approach.

42 ENGINEERING↗

3D Simulations of gas injection on callovo-oxfordian claystone assuming spatial heterogeneity and anisotropy

A series of gas injection tests on Callovo-Oxfordian (COx) claystone from the Bure underground research laboratory (URL) in France were carried out at the British Geological Survey (BGS). The tests were performed using a triaxial apparatus specifically designed to capture small volumetric strains induced by the injected gas flow and consequent material dilatancy. The long-duration experiments were monitored throughout. Measurements also included pressure, stresses (axial and radial stresses prescribed for each test stage), rate of gas inflow, gas outflow volume as well as pore-pressures observed at various points of the sample. A coupled hydro-gas-mechanical 3D numerical model has been developed to simulate the tests. Initial permeability is assumed heterogeneous throughout the specimen and embedded fractures are incorporated in the formulation. Gas pressure-induced deformations during the test lead to variations of permeability due to changes in matrix porosity and, especially, fracture aperture as well as fracture orientation due to material anisotropy. A programme of sensitivity analyses involving the variation of different aspects and parameters of the model contributes to a better understanding of the phenomena and highlights its complexity. The model is able to reproduce the observed behaviour of the tests.

58 GEOSCIENCES↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Topical Anesthetic Cream on Pain During Periareolar Injection of Technetium Tc99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer: A Randomized Control Trial

Injection of Tc99m to localize nodes for sentinel lymph node biopsy is reported by patients as very painful. The purpose of this study was to determine if anesthetic cream reduces pain associated with periareolar injection of Tc99m and to help elucidate conflicting literature regarding the efficacy of anesthetic cream for this procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationships between fault characteristics and seismic responses in a large lab-scale tri-axial injection test conducted on a faulted Castlegate Sandstone

Here to investigate mechanisms causing microseismicity (M w < 2) at a CO 2 injection site, a large-scale triaxial block experiment was carried out on a faulted (saw-cut) cubic-meter of Castlegate Sandstone. The experiment consisted of injection tests at varying differential stresses, while monitoring and recording pore pressure and acoustic emissions (AEs). During the experiment, ~33,000 AEs and ~14 mm of horizontal displacement/slip, like a strike-slip fault movement, occurred. To understand the AE responses and ascertain fault characteristics near the located AEs, we modeled the topography of the fault surface, fault aperture, and fault-gouge thickness using pre- and post-experiment laser scans of the fault surface on each half of the block. Additionally, we characterized surface roughness parallel and perpendicular to slip. Models show crushing and flattening of the fault surfaces can be linked to the spatiotemporal distribution of AEs within 50 mm of the fault surface. Approximately 65% of AEs were in areas with small aperture (≤300 μm); thicker fault gouge was observed in adjacent areas with wider aperture and shows a two-fold reduction in grain size relative to unaltered Castlegate Sandstone. This work provides a conceptual understanding on fault surface evolution, which can be applied towards modeling of seismic slip.

58 GEOSCIENCES↗

A state of the art Lambertson septum magnet of the RHIC beam injection system

The beam injection system of the Relativistic Heavy Ion Collider (RHIC) is the last section of the beam transfer line which transports the beam from the Alternating Gradient Synchrotron (AGS) to RHIC and comes under the acronym AtR (AGS to RHIC). The Lambertson septum magnet is one of the magnetic elements of the RHIC injection system. This paper presents results from the 2D and 3D electromagnetic design of the RHIC Lambertson septum magnet which has unique design features to minimize the magnetic field at the circulated beam region including the fringe field regions at the entrance and exit of the magnet.

43 PARTICLE ACCELERATORS↗

Thermal loading analysis of the ring injection dump for the Spallation Neutron Source facility

The ring injection dump (RID) is the largest beam dump in the Spallation Neutron Source facility at Oak Ridge National Laboratory and accepts a fraction of the beam from the ring that is not captured in the ring during injection. Thermo-fluid modeling of the RID components was performed during the initial design by using the software ANSYS CFX to characterize the power rating for the RID. From the calculations, the power rating was lowered from 200 kW to 150 kW, at 1.3 GeV beam energy due to concerns regarding the heating of the concrete structure. The Proton Power Upgrade project scope included reevaluating the power limit to the RID in anticipation that increasing it would provide more operational flexibility. The focus was on the shielding because it was the limiting factor, and data collected from thermocouples installed on the structure were used to benchmark the analysis. A three-stage process was adopted in the latest study. First, the already existing steady-state calculations were validated and extended with the latest Monte Carlo N-Particle source term calculations. Second, transient calculations were conducted to capture the dynamic state of the system in response to the energy dumped to the RID during the following operational period of the beam from 2005–2019 (14 years), and sensitivity analyses of crucial parameters were performed to benchmark the model with reasonable accuracy. Finally, an idealized transient cycle analysis was conducted with realistic duty factors to predict the temperature distribution at higher beam powers. Overall, the results confirmed the accuracy of the original steady state model but allowed the development of a new validated transient model with higher accuracy for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗

Electrical injection and transport in Teflon-diluted hole transport materials

Diluting small molecule organic semiconductor hole transport materials with Teflon AF (TAF) dramatically increases their thermal/morphological stability while counterintuitively also increasing the current density in hole-only diodes. Here, we explore the origin of this current enhancement in co-evaporated blends of TAF and N,N'-Di(1-naphthyl)-N,N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine (NPD) and find that it results from improved hole injection and not from a mobility enhancement due to semiconductor dilution effects. Whereas electroabsorption measurements indicate that an interface dipole shift of up to 0.5 eV (depending on TAF concentration) aides hole injection at the indium-tin-oxide anode, time-of-flight and temperature-dependent current-voltage measurements show that the mobility of 25 vol% TAF:NPD blends decreases by roughly an order of magnitude relative to neat NPD despite having slightly lower energetic disorder. For comparison, diluting with 25 vol% high density polyethylene achieves a similar reduction in energetic disorder but only decreases the mobility by a factor of two. Furthermore, these results highlight the tradeoff between reducing energetic disorder and frustrating percolation in diluted organic semiconductors, and represent a step toward thermally-evaporated polymer-small molecule composites that maintain high mobility while offering improved morphological stability and lower refractive index for organic light emitting diodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma ion heating by cryogenic pellet injection

In this work, the injection of cryogenic pellets into a magnetically confined plasma is shown to be accompanied by a considerable transfer of thermal energy from the electrons in the background plasma to the ions. The resulting ion heating can be significant, particularly in plasmas with disparate electron and ion temperatures, and can affect the energy balance of the plasma. In recent Wendelstein 7-X experiments, this mechanism can account for a substantial fraction of the ion heating power during pellet injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, low pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.

Orton, Daniel J.↗

Injectable, Guest–Host Assembled Polyethylenimine Hydrogel for siRNA Delivery

While siRNA has immense potential for therapeutic applications, advancement is limited by poor delivery systems. Systemically, siRNAs are rapidly degraded, may have off-target silencing, and necessitate high working concentrations. To overcome this, we developed an injectable, guest–host assembled hydrogel between polyethylenimine (PEI) and polyethylene glycol (PEG) for local siRNA delivery. Guest–host modified polymers assembled with siRNAs to form polyplexes that had improved transfection and viability compared to PEI. At higher concentrations, these polymers assembled into shear-thinning hydrogels that rapidly self-healed. With siRNA encapsulation, the assemblies eroded as polyplexes which were active and transfected cells, observed by Cy3-siRNA uptake or GFP silencing in vitro. When injected into rat myocardium, the hydrogels localized polyplex release, observed by uptake of Cy5.5-siRNA and silencing of GFP for 1 week in a GFP-expressing rat. These results illustrate the potential for this system to be applied for therapeutic siRNA delivery, such as in cardiac pathologies.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Supercritical CO 2 Injection on the Shale Pore Structures and Mass Transport Rates

Characterizing the pore structures and transport properties of low-permeability shales is critical for evaluating these formations as potential seals or storage sites for geological CO 2 sequestration. Here, we use low-pressure gas adsorption in conjunction with nuclear magnetic resonance (NMR) to characterize the pore-size distribution of shales before and after injection of supercritical CO 2 . Nitrogen gas was used as the detecting phase for the adsorption experiments and pentane liquid was used for the NMR experiments. We also performed time-resolved NMR and gravimetric microbalance measurements to observe mass transport during desaturation. We use these data to estimate the self-diffusion coefficient of pentane and changes in the saturation state of the pore network. We analyzed samples with a range of compositions from the Wolfcamp shale before and after exposure to supercritical CO 2 for 3 days. Integrating the gas adsorption and NMR data shows how supercritical CO 2 injection alters the pore-size distribution for pore sizes <1 nm to 1 mm. Finally, our results provide insights on how the pore structure and mass transport properties of different shale lithologies may evolve during storage of supercritical CO 2 .

58 GEOSCIENCES↗

Photoinduced Charge Carrier Dynamics and Electron Injection Efficiencies in Au Nanoparticle-Sensitized TiO 2 Determined with Picosecond Time-Resolved X-ray Photoelectron Spectroscopy

Progress in the development of plasmon-enabled light-harvesting technologies requires a better understanding of their fundamental operating principles and current limitations. In this work, we employ picosecond time-resolved X-ray photoemission spectroscopy to investigate photoinduced electron transfer in a plasmonic model system composed of 20 nm sized gold nanoparticles (NPs) attached to a nanoporous film of TiO 2 . The measurement provides direct, quantitative access to transient local charge distributions from the perspectives of the electron donor (AuNP) and the electron acceptor (TiO 2 ). On average, approximately two electrons are injected per NP, corresponding to an electron injection yield per absorbed photon of 0.1%. Back electron transfer from the perspective of the electron donor is dominated by a fast recombination channel proceeding on a time scale of 60 ± 10 ps and a minor contribution that is completed after ~1 ns. The findings provide a detailed picture of photoinduced charge carrier generation in this NP–semiconductor junction, with important implications for understanding achievable overall photon-to-charge conversion efficiencies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Powerful Organic Molecular Oxidants and Reductants Enable Ambipolar Injection in a Large-Gap Organic Homojunction Diode

Doping has proven to be a critical tool for enhancing the performance of organic semiconductors in devices like organic light-emitting diodes. However, the challenge in working with high-ionization-energy (IE) organic semiconductors is to find p-dopants with correspondingly high electron affinity (EA) that will improve the conductivity and charge carrier transport in a film. Here, we use an oxidant that has been recently recognized to be a very strong p-type dopant, hexacyano-1,2,3-trimethylene-cyclopropane (CN6-CP). The EA of CN6-CP has been previously estimated via cyclic voltammetry to be 5.87 eV, almost 300 meV higher than other known high-EA organic molecular oxidants. We measure the frontier orbitals of CN6-CP using ultraviolet and inverse photoemission spectroscopy techniques and confirm a high EA value of 5.88 eV in the condensed phase. The introduction of CN6-CP in a film of large-band-gap, large-IE phenyldi(pyren-1-yl)phosphine oxide (POPy 2 ) leads to a significant shift of the Fermi level toward the highest occupied molecular orbital and a 2 orders of magnitude increase in conductivity. Using CN6-CP and n-dopant (pentamethylcyclopentadienyl)(1,3,5-trimethylbenzene)ruthenium (RuCp*Mes)2, we fabricate a POPy 2 -based rectifying p–i–n homojunction diode with a 2.9 V built-in potential. Blue light emission is achieved under forward bias. Furthermore, this effect demonstrates the dopant-enabled hole injection from the CN6-CP-doped layer and electron injection from the (RuCp*Mes) 2 -doped layer in the diode.

36 MATERIALS SCIENCE↗

Injection‐Induced Shear Slip and Permeability Enhancement in Granite Fractures

Abstract Shear stimulation, so‐called hydroshearing , is believed to reactivate critical or near‐critical preexisting fractures by pressurized fluid injection, causing them to slip and dilate for economic production from geothermal and unconventional petroleum reservoirs. However, little or no experiments have been conducted to directly probe the coupled hydromechanical responses and permeability evolution during fracture shearing. In this paper, we present the results of novel injection‐induced shear tests on cylindrical granite samples each containing a single tensile or saw cut fracture. The shear test on rough fractures demonstrates that retainable permeability enhancement can be achieved through dilatant shear slip. The characteristic stick‐slip behavior of the fracture during shearing is also observed. Fracture aperture controlled by effective normal stress dominates the fluid flow in stick state, while in slip state, the major contributor to production increase is the irreversible normal dilation caused by fracture shear slip. The experimental data show that depending on the fracture roughness, the fracture slip process includes two quasi‐static slip intervals with a slip velocity of ~10 −9 to ~10 −6 m/s and a dynamic slip interval with a slip velocity of ~10 −7 to ~10 −5 m/s. The fracture slip correlates well with the associated stress relaxation: a faster fracture slip induces a quicker stress relaxation, and vice versa. The influence of surface roughness on the hydromechanical responses during fracture shearing and the shear‐induced asperity degradation are also studied. The various experimental observations on rough and smooth fractures clearly indicate that the key component to shear stimulation is fracture self‐propping by asperities.

Ye, Zhi↗

Chemo‐mechanical Alterations Induced From CO 2 Injection in Carbonate‐Cemented Sandstone: An Experimental Study at 71 °C and 29 MPa

Abstract Carbon capture, utilization, and storage may lead to mechanical degradation of the subsurface reservoir from fluid‐rock interaction, which could lead to wellbore instability or reservoir compaction. To better understand potential relationship between mechanical degradation with various carbonate cement textures and compositions in sandstone reservoirs, six flow‐through experiments were conducted. Formation water (TDS = 5,390 mg/L) enriched with CO 2 flowed through two types of Pennsylvanian Morrow B Sandstone: an ankerite‐siderite‐cemented sandstone (disseminated cement texture) and a calcite‐cemented sandstone (poikilotopic cement texture). The experiments produced little change in permeability in the ankerite‐siderite‐cemented sandstone, but permeability increased up to more than 1 order of magnitude in the calcite‐cemented sandstone. Ultrasonic measurements and cylinder‐splitting tests (also known as Brazilian tests) suggested negligible mechanical degradation of the ankerite‐siderite‐cemented sandstone. Variable changes, with significant mechanical degradation in the static moduli, were observed in the calcite‐cemented sandstone. Thus, dissolution of the disseminated ankerite‐siderite cement (0.28–0.30%) had minimal impact on modifying the flow network and the mechanical integrity of the sandstone, whereas dissolution of the poikilotopic calcite cement (0.89–1.13%, quantified with fluid chemistry and visualized with X‐ray microcomputed tomography) impacted the mechanical strength of the sandstone by disconnecting framework grains. With the high water‐to‐rock mass ratios (7.3–8.2) and number of pore volumes (147–675) employed in these experiments, potential risks are most relevant to regions near injection wells. Ultimately, the chemo‐mechanical effects induced by CO 2 injection are strongly influenced by the cement texture and composition and the burial history of the reservoir rock.

Wu, Z.↗