Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Design of the Multi-Ion Injector Linac for the JLAB EIC (JLEIC)

An Electron Ion Collider (EIC) is the highest priority for future U.S. accelerator-based nuclear physics facility following the completion of the Facility for Rare Isotope Beams (FRIB). Two laboratories are competing to host the future EIC: Brookhaven National Lab. (BNL) and Jefferson Lab. (JLab). The baseline design of JLab's Electron Ion Collider (JLEIC) ion complex comprises a pulsed superconducting (SC) linac injector capable of accelerating all ions from protons to lead, where proton and light ion beams can be polarized. After reviewing the design requirements for the injector linac, important design choices such as the room-temperature (RT) section design, the transition energy between the RT and SC sections and the stripping energy for heavy ions will be discussed. The design of the different linac sections will be presented as well as the results of end-to-end beam dynamics simulations for polarized deuterons and unpolarized lead ions.

Mustapha, B.↗

Optimized pulsed sideband cooling and enhanced thermometry of trapped ions

Resolved sideband cooling is a standard technique for cooling trapped ions below the Doppler limit to near their motional ground state. Yet the most common methods for sideband cooling implicitly rely on low Doppler-cooled temperatures and tightly confined ions and they cannot be optimized for different experimental conditions. Here we introduce a framework which calculates the fastest possible pulsed sideband cooling sequence for a given number of pulses and set of experimental parameters and we verify its improvement compared to traditional methods using a trapped 171 Yb + ion. After extensive cooling, we find that the ion motional distribution is distinctly nonthermal and thus not amenable to standard thermometry techniques. We therefore develop and experimentally validate an improved method to measure ion temperatures after sideband cooling. These techniques will enable more efficient cooling and thermometry within trapped-ion systems, especially those with high initial temperatures or spatially extended ion wave packets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of spontaneous emission in trapped-ion multiqubit gates at high magnetic fields

Penning traps have been used for performing quantum simulations and sensing with hundreds of ions and provide a promising route toward scaling up trapped ion quantum platforms because of the ability to trap and control hundreds or thousands of ions in two- and three-dimensional crystals. In both Penning traps and the more common RF Paul traps, lasers are often used to drive multi-qubit entangling operations. A leading source of decoherence in these operations is off resonant spontaneous emission. While many trapped ion quantum computers or simulators utilize clock qubits, other systems, especially those with high magnetic fields such as Penning traps, rely on Zeeman qubits, which require a more complex calculation of this decoherence. We therefore examine theoretically the impacts of spontaneous emission on quantum gates performed with trapped-ion ground state Zeeman qubits in a high magnetic field. In particular, we consider two types of gates—light-shift ($\hat{σ}^z_i$ $\hat{σ}^z_j$) gates and Mølmer-Sørensen ($\hat{σ}^x_i$ $\hat{σ}^x_j$) gates—obtained with laser beams directed approximately perpendicular to the magnetic field (the quantization axis) and compare the decoherence errors in each. Within each gate type, we also compare different operating points with regards to the detunings, polarizations, and required intensity of the laser beams used to drive the gates. Here, we show that both gates can have similar performance at their optimal operating conditions at high magnetic fields and examine the experimental feasibility of various operating points. By examining the magnetic field dependence of each gate, we demonstrate that, when the P state fine structure splitting is large compared to the Zeeman splittings, the theoretical performance of the Mølmer-Sørensen gate is significantly better than that of the light-shift gate. Additionally, for the light-shift gate, we make an approximate comparison between the fidelities that can be achieved at high fields with the fidelities of state-of-the-art two-qubit trapped ion quantum gates. We show that, with regards to spontaneous emission, the achievable fidelity of the current NIST configuration is about an order of magnitude below that of the best low-field gates, but we also discuss several alternative configurations with potential error rates that are comparable with those for state-of-the art trapped ion gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast ground-state-to-ground-state separation of small ion crystals

Rapid separation of linear crystals of trapped ions into different subsets is critical for realizing trapped ion quantum computing architectures where ions are rearranged in trap arrays to achieve all-to-all connectivity between qubits. Here we introduce a general theoretical framework that can be used to describe the separation of same-species and mixed-species crystals into smaller subsets. The framework relies on an efficient description of the evolution of Gaussian motional states under quadratic Hamiltonians that only requires a special solution of the classical equations of motion of the ions to describe their quantum evolution under the influence of a time-dependent applied potential and the ions' mutual Coulomb repulsion. We provide time-dependent applied potentials suitable for separation of a mixed-species three-ion crystal on timescales similar to that of free expansion driven by Coulomb repulsion, with all modes along the crystal axis starting and ending close to their ground states. Three separately confined mixed-species ions can be combined into a crystal held in a single well without energy gain by time-reversal of this separation process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion acceleration from microstructured targets irradiated by high-intensity picosecond laser pulses

Structures on the front surface of thin foil targets for laser-driven ion acceleration have been proposed to increase the ion source maximum energy and conversion efficiency. While structures have been shown to significantly boost the proton acceleration from pulses of moderate-energy fluence, their performance on tightly focused and high-energy lasers remains unclear. Here, we report the results of laser-driven three-dimensional (3D)-printed microtube targets, focusing on their efficacy for ion acceleration. Using the high-contrast (~10 12) PHELIX laser (150 J, 10 21 W / cm 2 ), we studied the acceleration of ions from 1-μm-thick foils covered with micropillars or microtubes, which we compared with flat foils. The front-surface structures significantly increased the conversion efficiency from laser to light ions, with up to a factor of 5 higher proton number with respect to a flat target, albeit without an increase of the cutoff energy. An optimum diameter was found for the microtube targets. Our findings in this work are supported by a systematic particle-in-cell modeling investigation of ion acceleration using 2D simulations with various structure dimensions. Simulations reproduce the experimental data with good agreement, including the observation of the optimum tube diameter, and reveal that the laser is shuttered by the plasma filling the tubes, explaining why the ion cutoff energy was not increased in this regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling electrokinetic flows with the discrete ion stochastic continuum overdamped solvent algorithm

In this article we develop an algorithm for the efficient simulation of electrolytes in the presence of physical boundaries. In previous work the discrete ion stochastic continuum overdamped solvent (DISCOS) algorithm was derived for triply periodic domains, and was validated through ion-ion pair correlation functions and Debye-Hückel-Onsager theory for conductivity, including the Wien effect for strong electric fields. In extending this approach to include an accurate treatment of physical boundaries we must address several important issues. First, the modifications to the spreading and interpolation operators necessary to incorporate interactions of the ions with the boundary are described. Next we discuss the modifications to the electrostatic solver to handle the influence of charges near either a fixed potential or dielectric boundary. An additional short-ranged potential is also introduced to represent interaction of the ions with a solid wall. Finally, the dry diffusion term is modified to account for the reduced mobility of ions near a boundary, which introduces an additional stochastic drift correction. Herein, several validation tests are presented confirming the correct equilibrium distribution of ions in a channel. Additionally, the methodology is demonstrated using electro-osmosis and induced-charge electro-osmosis, with comparison made to theory and other numerical methods. Notably, the DISCOS approach achieves greater accuracy than a continuum electrostatic simulation method. We also examine the effect of under-resolving hydrodynamic effects using a “dry diffusion” approach, and find that considerable computational speedup can be achieved with a negligible impact on accuracy.

97 MATHEMATICS AND COMPUTING↗

Measurements of ion-electron energy-transfer cross section in high-energy-density plasmas

Here, we report on measurements of the ion-electron energy-transfer cross section utilizing low-velocity ion stopping in high-energy-density plasmas at the OMEGA laser facility. These measurements utilize a technique that leverages the close relationship between low-velocity ion stopping and ion-electron equilibration. Shock-driven implosions of capsules filled with D 3 He gas doped with a trace amount of argon are used to generate densities and temperatures in ranges from 1 × 10 23 to 2 × 10 24 cm –3 and from 1.4 to 2.5 keV, respectively. The energy loss of 1-MeV DD tritons and 3.7-MeV D 3 He alphas that have velocities lower than the average velocity of the thermal electrons is measured. The energy loss of these ions is used to determine the ion-electron energy-transfer cross section, which is found to be in excellent agreement with quantum-mechanical calculations in the first Born approximation. This result provides an experimental constraint on ion-electron energy transfer in high-energy-density plasmas, which impacts the modeling of alpha heating in inertial confinement fusion implosions, magnetic-field advection in stellar atmospheres, and energy balance in supernova shocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular dynamics study of silicon atomic layer etching by chlorine gas and argon ions

Classical molecular dynamics (MD) is used to simulate atomic layer etching processes of silicon by alternating exposure to chlorine gas and argon ions. In order to validate our model, a rigorous comparison is done with ion beam experiments found in the literature [Park et al., Jpn. J. Appl. Phys. 44, 389 (2005)]. Here it is shown that the etch per cycle (EPC) as a function of argon ion energy from simulations is in quantitative agreement with experimental results if the correct argon ion fluence is used in the simulations. The EPC as a function of ion irradiation time and amount of chlorine exposure also show good agreement with the experiment. The MD simulations also show the formation of an amorphous silicon region with chlorine atoms mixed uniformly throughout following ion bombardment. Finally, the etch products during the ion irradiation step are analyzed and discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Phase composition of polycrystalline HfNx (0.45 ≤ x ≤ 1.60) and effects of low-energy ion irradiation on microstructure, texture, and physical properties

We have investigated the phase composition of HfNx as a function of x and the effects of low-energy ion irradiation on the microstructure and physical properties of polycrystalline layers grown on SiO2 at 350 °C by ultrahigh vacuum reactive dc magnetron sputtering of Hf in mixed N2/Ar discharges. X-ray diffraction and Rutherford backscattering spectrometry results show that the phases obtained in polycrystalline HfNx layers with increasing x are hcp-structure α-Hf:N (x ≲ 0.6); multiphase mixtures consisting of α-Hf, NaCl-structure δ-HfN, rhombohedral ɛ-Hf3N2, and/or ζ-Hf4N3 (0.6 ≲ x ≲ 0.9); δ-HfN single phase (0.9 ≲ x ≲ 1.3); and mixtures of δ-HfN and higher nitrides (x ≳ 1.3). HfNx layers with 0.9 ≲ x ≲ 1.2 grown under mild ion irradiation (incident ion energy Ei ≃ 7 eV and ion-to-Hf flux ratios Ji/JHf = 1−3) are underdense with mixed orientation, low in-plane stress, and rough surface morphology due to limited adatom mobilities resulting in kinetic roughening and atomic shadowing during film growth. However, the use of intense ion irradiation (Ei = 25 eV and Ji/JHf = 4−20) results in HfNx layers, which are fully dense with strongly 111-oriented texture, compressive in-plane stress, and smooth surfaces due to ion irradiation enhanced adatom surface mobilities. In addition, the latter films have lower resistivity and higher hardness. For stoichiometric δ-HfN layers, ρ decreases from 69.7 to 35.2 μΩ cm and H increases from 22.1 to 27.4 GPa, with increasing ion-irradiation intensity. However, for HfNx layers with 1.2 ≲ x ≲ 1.6, the correspondingly higher steady state atomic N surface coverages during deposition alter growth kinetics in favor of 001 texture with a fully dense structure and compressive in-plane stress.

Materials Science↗

Direct quantification of ion composition and mobility in organic mixed ionic-electronic conductors

Ion transport in organic mixed ionic-electronic conductors (OMIECs) is crucial due to its direct impact on device response time and operating mechanisms but is often assessed indirectly or necessitates extra assumptions. Operando x-ray fluorescence (XRF) is a powerful, direct probe for elemental characterization of bulk OMIECs and was used to directly quantify ion composition and mobility in a model OMIEC, poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) (PEDOT:PSS), during device operation. The first cycle revealed slow electrowetting and cation-proton exchange. Subsequent cycles showed rapid response with minor cation fluctuation (~5%). Comparison with optical-tracked electrochromic fronts revealed mesoscale structure–dependent proton transport. The calculated effective ion mobility demonstrated thickness-dependent behavior, emphasizing an interfacial ion transport pathway with a higher mobile ion density. The decoupling of interfacial effects on bulk ion mobility and the decoupling of cation and proton migration elucidate ion transport in conventional and emerging OMIEC-based devices and has broader implications for other ionic conductors writ large.

42 ENGINEERING↗

Ion Pairing, Clustering and Transport in a LiFSI-TMP Electrolyte as Functions of Salt Concentration using Molecular Dynamics Simulations

Battery capacity is highly related to ion-pairing mechanisms in electrolytes, since a cluster formation can lead to dead Li formation, reducing the number of charge carriers and leading to capacity fading. We use molecular dynamics simulations to model an electrolyte comprising trimethyl phosphate (TMP) solvent and a lithium bis(fluorosulfonyl)imide (LiFSI) salt, exploring effects of salt concentration on solvation and ion-transport. We simulate the LiFSI-TMP electrolyte for salt concentrations of 0.7, 1.43 and 3.82 molar. A statistical analysis was performed to study ion-pairing, clustering, diffusivity, conductivity, and coordination of Li-ions, providing insights into relations between molecular structures and transport properties. Molecular structure of ionic components changes as concentration increases, from a predominant solvent separated ion pair (SSIP) and contact ion pair (CIP) to aggregate salt (AGG) and ionic cluster formation. Given the formation of the ionic cluster, the diffusion mechanism followed by Li-ions changes from a hopping/exchange to a vehicular mechanism as concentration increases; this is reflected in a decrease of ionic conductivities. Ionicity was also calculated to reveal how the ionic motion changes from an uncorrelated to a correlated one as the salt concentration increases. Furthermore, we also compared our results with experimental calculations performed for similar electrolyte systems

25 ENERGY STORAGE↗

Exploring the Storage Mechanism of Alkali Ions in Non-Graphitic Hard Carbon Anodes

This study aims to develop high-capacity hard carbon anode materials for alkali-ion batteries by controlling the microstructures of non-graphitic hard carbon through an annealing protocol and investigating the effects on the alkali-ion storage mechanisms using physical, chemical, and electrochemical analytical techniques. The hard carbon materials were synthesized at temperatures ranging from 900 °C to 1600 °C. Those synthesized at 1100 °C with high surface area and abundant defects exhibited the highest reversible capacity in Li- and K-ion systems, with the storage dominated by surface-adsorption mechanisms. In contrast, the hard carbon compounds prepared at 1400 °C with numerous curve-featured pores delivered the highest reversible capacity in the Na-ion system, indicating that these pores are the preferred Na-ion storage sites, particularly in low-voltage plateau regions. This study provides a comprehensive understanding of the relationship between microstructures and alkali-ion storage mechanisms in non-graphitic hard carbon and highlights the importance of tailoring the microstructures of hard carbon to achieve high specific capacity for the desired alkali-ion species.

25 ENERGY STORAGE↗

Exposure to multiple ion beams, broadly representative of galactic cosmic rays, causes perivascular cardiac fibrosis in mature male rats

Long-duration space exploratory missions to the Earth’s moon and the planet Mars are actively being planned. Such missions will require humans to live for prolonged periods beyond low earth orbit where astronauts will be continuously exposed to high energy galactic cosmic rays (GCRs). A major unknown is the potential impact of GCRs on the risks of developing degenerative cardiovascular disease, which is a concern to NASA. A ground-based rat model has been used to provide a detailed characterization of the risk of long-term cardiovascular disease from components of GCRs at radiation doses relevant to future human missions beyond low earth orbit. Six month old male WAG/RijCmcr rats were irradiated at a ground-based charged particle accelerator facility with high energy ion beams broadly representative of GCRs: protons, silicon and iron. Irradiation was given either as a single ion beam or as a combination of three ion beams. For the doses used, the single ion beam studies did not show any significant changes in the known cardiac risk factors and no evidence of cardiovascular disease could be demonstrated. In the three ion beam study, the total cholesterol levels in the circulation increased modestly over the 270 day follow up period, and inflammatory cytokines were also increased, transiently, 30 days after irradiation. Perivascular cardiac collagen content, systolic blood pressure and the number of macrophages found in the kidney and in the heart were each increased 270 days after irradiation with 1.5 Gy of the three ion beam grouping. These findings provide evidence for a cardiac vascular pathology and indicate a possible threshold dose for perivascular cardiac fibrosis and increased systemic systolic blood pressure for complex radiation fields during the 9 month follow up period. The development of perivascular cardiac fibrosis and increased systemic systolic blood pressure occurred at a physical dose of the three ion beam grouping (1.5 Gy) that was much lower than that required to show similar outcomes in earlier studies with the same rat strain exposed to photons. Further studies with longer follow up periods may help determine whether humans exposed to lower, mission-relevant doses of GCRs will develop radiation-induced heart disease.

60 APPLIED LIFE SCIENCES↗

A Magnetized Electron Source For Ion Beam Cooling

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility would augment the existing ion/proton facility with an electron accelerator. Thomas Jefferson National Accelerator Facility (JLab) plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require cooling of the ion beams in order to reach the luminosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunched-beam cooling, while JLab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions, such as flat beam klystrons and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high-performance injectors for electron cooling is limited, the market for high-frequency RF sources and compact X-ray systems is con- siderable. Thus, the design methodologies developed in this project have a wide range of applicability. In Phase I of this SBIR project, Xelera Research LLC performed simulations and calcu- lations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and tech- niques that are applicable not only to specific machine designs but to other applications requiring magnetized injectors as well. In this Phase II SBIR project, Xelera Research LLC, in collaboration with a team at JLab, designed, built, and tested a thermionic elec- tron source for driving a magnetized electron cooler in a future electron-ion collider project. This device was delivered to JLab in July 2019 and achieved first beam in December 2019.

43 PARTICLE ACCELERATORS↗

Microstructural Simulation of Ion-Irradiated Natural Rocks and Minerals

This report details the contribution of Oak Ridge National Laboratory to the Nuclear Energy University Program (NEUP) project, "Rapid Characterization of Concrete Mineralogy using Multi-Scale Tools" led by the University of Illinois at Urbana-Champaign. To support the subsequent license renewal (SLR) of the US nuclear power plants (NPPs) fleet, the performance of concrete-forming aggregates against neutron irradiation needs to be assessed. Ion irradiation is proposed as a rapid, cost-effective surrogate method to full neutron irradiation testing. To complement the characterization of ion-irradiated rock specimens, ORNL has run finite-elements and fast-Fourier transform (FFT-based) simulations using the codes MARS and Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC). The main conclusion of this analysis is that the apparent post–ion-irradiation step-height underestimates the accumulated free radiation-induced volumetric expansion (RIVE) in the ion-implanted depth by about 15% at full amorphization and about 25% toward the beginning of the ion irradiation experiment. The discrepancy is explained by the fact that the step height is proportional to the sum of the RIVE (i.e., one third of the RIVE) and the irradiation-assisted plastic strains in the vertical direction (lower than two thirds of the RIVE). Because of the large lateral compressive stresses caused by the restraining effect of the unirradiated substrate, the stress field in the mineral grains and at the grain boundary (GB) in the ion-implanted layer is much different than the comparable stress field occurring during neutron irradiation. Hence, the mismatch RIVE causing cracks in the rock-forming minerals leads to different cracking patterns. Ion irradiation continues to be used as a rapid technique to assess the RIVE potential of rocks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Species mix & distribution function dependence of energetic-ion driven magnetospheric instabilities on DIII-D (Final Report)

Energetic ions drive a rich variety of instabilities in the complex multi-species plasma of Earth’s magnetosphere. This experiment exploited the highly flexible, high power particle beam injection capability and sophisticated diagnostic suite of the DIII-D tokamak to advance understanding of two particular instabilities of significant interest to the magnetospheric research community that have closely-related counterparts in beam-heated tokamak plasmas: electromagnetic ion cyclotron waves (EMIC) [1], observed at frequencies somewhat below the ion cyclotron frequencies of bulk ion species, and equatorial noise [2], observed at energetic-ion cyclotron harmonics. In the magnetic fusion energy domain, such waves are called ICE (Ion Cyclotron Emission). Recent substantial advances in diagnostic capability in the ion cyclotron range of frequencies in DIII-D, including measurement of wave polarization, spa)al structure and amplitude created an exciting opportunity to challenge and drive advances in theoretical understanding of these phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗