Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

Effective control of ion fluxes over large areas by magnetic fields: From narrow beams to highly uniform fluxes

An effective control of the ion current distribution over large-area (up to 10{sup 3} cm{sup 2}) substrates with the magnetic fields of a complex structure by using two additional magnetic coils installed under the substrate exposed to vacuum arc plasmas is demonstrated. When the magnetic field generated by the additional coils is aligned with the direction of the magnetic field generated by the guiding and focusing coils of the vacuum arc source, a narrow ion density distribution with the maximum current density 117 A m{sup -2} is achieved. When one of the additional coils is set to generate the magnetic field of the opposite direction, an area almost uniform over the substrate of 10{sup 3} cm{sup 2} ion current distribution with the mean value of 45 A m{sup -2} is achieved. Our findings suggest that the system with the vacuum arc source and two additional magnetic coils can be effectively used for the effective, high throughput, and highly controllable plasma processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ptychography with broad-bandwidth radiation

Ptychography, a scanning Coherent Diffractive Imaging (CDI) technique, has quickly gained momentum as a robust method to deliver quantitative images of extended specimens. A current conundrum for the development of X-ray CDI is the conflict between a need for higher flux to reach higher resolutions and the requirement to strongly filter the incident beam to satisfy the tight coherence prerequisite of the technique. Latest developments in algorithmic treatment of ptychographic data indicate that the technique is more robust than initially assumed, so that some experimental limitations can be substantially relaxed. Here, we demonstrate that ptychography can be conducted in conditions that were up to now considered insufficient, using a broad-bandwidth X-ray beam and an integrating scintillator-based detector. Our work shows the wide applicability of ptychography and paves the way to high-throughput, high-flux diffractive imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Warm Electron Beam Ion Trap (WEBIT): An instrument for ground calibration of space-borne x-ray spectrometers

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve’s instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

47 OTHER INSTRUMENTATION↗

Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution

Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.

60 APPLIED LIFE SCIENCES↗

Enabling Low-Overhead HT-HPC Workflows at Extreme Scale using GNU Parallel

GNU Parallel is a versatile and powerful tool for process parallelization widely used in scientific computing. This paper demonstrates its effective application in high-performance computing (HPC) environments, particularly focusing on its scalability and efficiency in executing large-scale high-throughput high-performance computing (HT-HPC) workflows. Through real-world examples, we highlight GNU Parallel’s performance across various HPC workloads, including GPU computing, container-based workloads, and node-local NVMe storage. Our results on two leading supercomputers, OLCF’s Frontier and NERSC’s Perlmutter, showcase GNU Parallel’s rapid process dispatching ability and its capacity to maintain low overhead even at extreme scales. We explore GNU Parallel’s application in massive parallel file transfers using a scheduled Data Transfer Node (DTN) cluster, emphasizing its broad utility in diverse scientific workflows. Beyond its direct application as a viable workflow manager, GNU Parallel can be employed in conjunction with other workflow systems as a "last-mile" parallelizing driver and as a quick prototyping tool to design and extract parallel profiles from application executions. We then argue that the potential for GNU Parallel to transform workflow management at extreme scales is substantial, paving the way for more efficient and effective scientific discoveries.

Maheshwari, Ketan↗

Strategic Buffer Layer Development for YBCO Coated Conductors

We have developed a simplified buffer layer architecture for the rolling-assisted biaxially textured substrates (RABiTS) template approach. The overall purpose of this research is to enable potentially a low-cost, high throughput and high yield manufacturing processes for buffer fabrication and to gain fundamental understanding of the growth of buffer layers for RABiTS templates. This understanding is critical to the development of a reliable, robust, and long-length manufacturing process for second generation wires. In this study, efforts are being made to either reduce the number of vacuum deposited layers or to replace one or more of these vacuum deposited layers with a solution based layer. We have chosen Gd{sub 2}O{sub 3} - ZrO{sub 2} system as a potential barrier layer for this study. We have deposited epitaxial Gadolinia Stabilized Zirconia (GSZ) (Zr{sub 1-x}Gd{sub x}O{sub y}; x = 0-1) films on 30-nm thick e-beam evaporated Y{sub 2}O{sub 3} seeded Ni-W (3 at. %) (Ni-3W) substrates using a metal-organic decomposition (MOD) process. Detailed X-ray studies indicated that all of the MOD-GSZ layers were cube textured and both in-plane and out-of-plane lattice parameters increases linearly with increasing the Gd content. We have also developed process conditions for reactively sputter deposited epitaxial Gd{sub 2}Zr{sub 2}O{sub 7} (Gadolinium Zirconium Oxide (GZO); Zr{sub 1-x}Gd{sub x}O{sub y} (x = 0.5)) films on the e-beam evaporated Y{sub 2}O{sub 3}/Ni - 3W substrates. YBCO films with a critical current density J{sub c} of 2.14 times 10{sup 6} A/cm{sup 2} and 1.4 times 10{sup 6} A/cm{sup 2} at 77 K and self-field were grown on the newly developed architectures of Gd{sub 2}Zr{sub 2}O{sub 7}/Y{sub 2}O{sub 3}/Ni - 3W and Zr{sub 1-x}Gd{sub x}O{sub y} (x = 0.2)/Y{sub 2}O{sub 3}/Ni - 3W substrates, respectively using a pulsed laser deposition (PLD) process. This work promises a route for producing cost-effective simplified buffer architectures for the RABiTS-based YBCO coated conductors.

36 MATERIALS SCIENCE↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid solution centrifugation for safe, scalable, and efficient isotope separation

A general method of separating isotopes by centrifuging dissolved chemical compounds in a liquid is introduced. This technique can be applied to almost all elements and leads to large separation factors. The method has been demonstrated in several isotopic systems including Ca, Mo, O, and Li with single-stage selectivities of 1.046 to 1.067 per neutron mass difference (e.g., 1.43 in 40 Ca/ 48 Ca), which are beyond the capabilities of various conventional methods. Equations are derived to model the process, and the results agree with those of the experiments. The scalability of the technique has been demonstrated by a three-stage enrichment of 48 Ca with a total 40 Ca/ 48 Ca selectivity of 2.43, and the scalability is more broadly supported through analogies to gas centrifuge, whereby countercurrent centrifugation can further multiply the separation factor by 5 to 10 times per stage in a continuous process. Optimal centrifuge conditions and solutions can achieve both high-throughput and highly efficient isotope separation.

07 ISOTOPE AND RADIATION SOURCES↗

Xi-CAM v1.2.3

Xi-CAM aims to provide a community driven platform for multimodal analysis in synchrotron science. The platform core provides a robust plugin infrastructure for extensibility, allowing continuing development to simply add further functionality. Current modules include tools for characterization with (GI)SAXS, Tomography, and XAS. This will continue to serve as a development base as algorithms for multimodal analysis develop. Seamless remote data access, visualization and analysis are key elements of Xi-CAM, and will become critical to synchrotron data infrastructure as expectations for future data volume and acquisition rates rise with continuously increasing throughputs. The highly interactive design elements of Xi-cam will similarly support a generation of users which depend on immediate data quality feedback during high-throughput or burst acquisition modes.

Pandolfi, Ronald↗

pnnl/ZebrafishBMD

ZebrafishBMD: A software tool to perform benchmark dose calculations using toxicity screening data of high-throughput zebrafish assays. High-content imaging of larval zebrafish behavior can be used as a screening approach to rapidly evaluate the relative potential for chemicals to cause toxicity. However, most statistical methods applied to these data transform movement values to incidence-based “hits” and calculate lowest effect levels (LELs), which loses individual fish resolution of behavior and defies hazard ranking due to reliance on applied dose levels. We developed a parallelizable workflow to calculate benchmark dose (BMD) values from dynamic, high-content zebrafish behavior data that scales for high throughput chemical screening. To capture the zebrafish movement response from light to dark stimulus, we summarized time-dependent data using both area under the curve and the immediate change at the transition point into two novel metrics that characterized abnormal behavior as a function of chemical concentration. The BMD workflow was applied to calculate BMD10 values of 1,060 ToxCast chemicals for 24 zebrafish endpoints, including behavior, mortality and morphology. ZebrafishBMD implements the BMD workflow and provides Matlab scripts to read the data (stored in a specific structure) from a .mat file, to calculate the behavioral endpoint values from movement versus time data, to construct concentrationresponse curves, to perform curve-fitting, and to calculate BMD10 values.

Thomas, Dennis↗

DIVA/DeviceEditor v6.1.2

DIVA is an end-to-end DNA design and construction management platform that streamlines how researchers design, build, and receive sequence-verified DNA constructs. Through a web-based BioCAD interface (DeviceEditor), researchers independently design DNA constructs and submit them to a centralized queue with a single action. Designs progress transparently through standardized states which allow researchers to track status and access finished constructs via a central DNA repository. Submitted designs are reviewed by dedicated staff for feasibility and optimization, reducing costly failures and improving downstream execution. Automated DNA assembly software optimizes construction strategies by reusing existing parts where possible and sourcing synthetic DNA only when needed. Standardized, sequence-agnostic assembly methods enable many independent constructs to be built in parallel using lab automation, dramatically increasing throughput. High-throughput next-generation sequencing is used to verify construct accuracy, with flexible platforms selected based on task requirements. Throughout the process, detailed success and failure data are captured and analyzed, enabling continuous improvement of assembly protocols. Compared to traditional, manual DNA construction workflows, DIVA offers higher scalability, transparency, reproducibility, and data-driven optimization.

Plahar, Hector [Lawrence Berkeley National Laborat↗

In-Line Crack and Stress Detection in Silicon Solar Cells Using Resonance Ultrasonic Vibrations

The Phase II project has the following specific tasks: (i) specify optimal configurations of the in-line system's component hardware and software; (ii) develop and justify a system prototype that meets major specifications for an in-line crack detection unit, such as high throughput rate, high level of stability, reproducibility of data acquisition and analysis, and high sensitivity with respect to crack length and crack location; (iii) design a system platform that allows easy integration within and adaptation to various solar cell belt-type production lines; (iv) develop a testing protocol providing quality certification of the production-grade system. Commercial Application of the proposed activity consists of bringing to the solar market a new high-tech product based on an innovative solution and patented methodology to contribute to cost reduction of silicon solar module production. The solar industry, with crystalline silicon as a dominant segment, shows outstanding performance, with approximately 25% yearly growth during the last years. Despite a slowdown with only 5.6 GW installations in 2009, solar module production for the 2010 and 2011 years was recovered. According to European Photonics Industry Consortium new solar PV installations grow by 56% compared to 2010 reached 64.7 GW in 2011. Revenues in the PV industry reached a record high of $93 billion in 2011, a 13.4 percent gain over 2010 and 150 percent over 2009. This growth was forecasted to continue in 2013 with double digits growth. The solar industry is economically driven to make solar panels of the highest conversion efficiency and reliability at the lowest production cost. The Resonance Ultrasonic Vibration system addresses critical needs of the silicon-based solar industry by providing a quality control method and tool, which will improve productivity, increase reliability of products and reduce manufacturing cost of solar panels.

14 SOLAR ENERGY↗

Scintillators

As concerns about the illicit movement of radioactive materials across international borders increase, so too has the need for increased protection of those borders both foreign and domestic. The challenge is not only to detect hidden radioactive materials, but also to distinguish them from legitimate radionuclides such as radio-pharmaceuticals that are often transported across borders and shipped throughout a country. With more than 600 U.S. border sites to protect, screening imported radioactive material requires a careful balance of high throughput and high search efficiency. However, these requirements are difficult to meet as rapid screening operations leave less time for radiation detectors to efficiently evaluate materials. In support of border security, Sandia developed organic glass scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New High-Entropy Perovskite Oxides with Increased Reducibility and Stability for Thermochemical Hydrogen Generation

This project aims to design, synthesize, and test a transformative class of High-Entropy Perovskite Oxides (HEPOs) as redox oxides to enable thermochemical hydrogen generation with improved stability, kinetics, and efficiency. These developed HEPOs are expected to demonstrate improved kinetics with oxygen surface exchange coefficient ( k > 7.5×10 -4 cm/s) in Budget Period (BP) 1, retain its structural stability in a broad range of oxygen non-stoichiometry (Δδ > 0.15) at a low operating reduction temperature of T red < 1400°C in BP 2, and deliver a H 2 yield of over 400 µmol per gram of oxide and high stability with less than 20% degradation after at least 50 cycles in BP 3. This project is feasible due to the unique thermodynamic properties (simultaneously increased reducibility and phase stability) and kinetic characters (stability against particle coarsening and potentially enhanced oxygen transport and surface reaction kinetics) of such HEPOs, and it is enabled by a unique active learning computational design approach. Computational studies have been conducted to investigate the oxygen vacancy formation in complex perovskite systems. * Accurate prediction of V O .. concentration with disordered A-site cations in Fe-based high-entropy perovskite oxides * Combined MC/DFT computation elucidates the mechanism of Co preference on the redox due to the strain introduced by local distortion. In this project, we explored a large number (~150) of perovskite compositions, which are listed in Tables 2 – 4). * All perovskite specimens have been synthesized through a high-throughput high-energy ball milling process, followed by the conventional sintering process. * XRD, SEM/EDS and TGA were performed to confirm the crystal structure, phase homogeneity and oxygen non-stoichiometry for compositionally complex perovskite oxides (CCPOs). * 110 compositions show single-phase from XRD * Unusual aliovalent doping effects in medium-entropy perovskite compositions. * V-shape relation between Δδ vs. x (La 1-x Sr x )(Mn 1/3 Fe 1/3 Ti 1/3 )O 3 * The highest reported hydrogen production for the CCPOs made in this project ( T re = 1350 ºC 30 min, T Ox = 1100 ºC 30 min) * B-site mixing (La 0.8 Sr 0.2 )(Mn 0.2 Fe 0.2 Co 0.4 Al 0.2 )O 3 : 89.97 ± 2.73 mmol H2 /mol oxide (395 ± 10 μmol/g oxide ) (i) No phase transformation during reactions when Co molar ratio is less than 61% (ii) Balance between intrinsic kinetics (oxygen surface exchange) and thermodynamics (oxygen non-stoichiometry) (iii) Preference of Co identified by in-situ XPS * A-site mixing (La 1/6 Pr 1/6 Nd 1/6 Gd 1/6 Ba 1/6 Sr1/6)MnO 3 : 98.48 mmol H2 /mol oxid e (~415 μmol/g oxide )

08 HYDROGEN↗

Systems biology and biomarker discovery

Medical practitioners have always relied on surrogate markers of inaccessible biological processes to make their diagnosis, whether it was the pallor of shock, the flush of inflammation, or the jaundice of liver failure. Obviously, the current implementation of biomarkers for disease is far more sophisticated, relying on highly reproducible, quantitative measurements of molecules that are often mechanistically associated with the disease in question, as in glycated hemoglobin for the diagnosis of diabetes [1] or the presence of cardiac troponins in the blood for confirmation of myocardial infarcts [2]. In cancer, where the initial symptoms are often subtle and the consequences of delayed diagnosis often drastic for disease management, the impetus to discover readily accessible, reliable, and accurate biomarkers for early detection is compelling. Yet despite years of intense activity, the stable of clinically validated, cost-effective biomarkers for early detection of cancer is pathetically small and still dominated by a handful of markers (CA-125, CEA, PSA) first discovered decades ago. It is time, one could argue, for a fresh approach to the discovery and validation of disease biomarkers, one that takes full advantage of the revolution in genomic technologies and in the development of computational tools for the analysis of large complex datasets. This issue of Disease Markers is dedicated to one such new approach, loosely termed the 'Systems Biology of Biomarkers'. What sets the Systems Biology approach apart from other, more traditional approaches, is both the types of data used, and the tools used for data analysis - and both reflect the revolution in high throughput analytical methods and high throughput computing that has characterized the start of the twenty first century.

59 BASIC BIOLOGICAL SCIENCES↗

Sheet silicon cell/module technology

The cost involved in the performance of the standard operations for the manufacture of silicon wafers is insignificant in the case of space photovoltaics applications. It is, however, a decisive factor with respect to terrestrial applications of silicon photovoltaic devices. In 1975, a program was, therefore, begun to develop low cost silicon solar arrays for terrestrial applications. The goal was silicon-based photovoltaic (PV) modules ready for installation at a selling price of $0.50/watt (1975 dollars). Sheet and ribbon silicon growth held out the promise of reduced cost through continuous operation, high material throughput, high material utilization efficiency, and a product whose shape lent itself to the assembly of high packing density modules. Attention is given to ribbon growth technologies, sheet technology generic problems, and ribbon cell and module technology status. It is concluded that the potential for crystalline ribbon silicon appears to be better today than ever before.

Morrison, A. D.↗

Status of GaAs solar cell production

Recent experience in producing GaAs solar cells, to meet the full requirements of space-array manufacturers is reviewed. The main problems have been in extending MOCVD technology to provide high throughput of high quality epitaxial layers, and to integrate the other important factors needed to meet the full range of user requirements. Some discussion of evolutionary changes is also given.

Yeh, Milton↗