Investigation of magnetically soft, high-temperature cobalt-iron alloy
Magnetically soft, high temperature cobalt-iron alloy
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Magnetically soft, high temperature cobalt-iron alloy
The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.
Doped LaCrO 3 perovskites hold promise as robust materials for electrical interconnects and sensor applications in harsh environments. In this work, we investigated the high-temperature behavior of La 1–x Sr x CrO 3 , La 1–x Ca x CrO 3 and La 0.8 Sr 0.2 Cr 1-x Mn x O3 (0.1 ≤ x ≤ 0.4) through a combination of computational modeling and physical characterization up to 1500 °C. Crystalline structural properties were determined and compared with ab-initio calculations, which demonstrated excellent agreement with experimental findings. High-temperature electrical conductivity measurements were performed under different atmospheres. Calcium and strontium/manganese co-doped lanthanum chromites exhibited typical semiconductor exponential trends and conductivity showed proportional correlation with substitutions levels up to 30 %. The DFT modelling was completed up to 1500 °C, including low and high temperature chromite phases and oxygen vacancies insertion. Calculations were correlated with experimental electrical properties. This work expands the understanding of doped lanthanum chromites and paves the way for the development of materials suitable for demanding high-temperature applications.
Efforts to determine the critical technologies necessary for the development of a high-temperature GO2/GH2 thruster are reviewed, for space station applications. Two types of thrust chambers are evaluated: one operable at high temperature and the other incorporating regenerative cooling. The high temperature chamber made of rhenium requires minimum cooling of the chamber wall, however, an oxidation barrier should be incorporated to prevent the rhenium thruster from readily oxidizing. The use of rhenium brought about a lower cost, lower weight, and simplicity of fabrication. The igniter-injector, the chamber, the test facility, and the test program are discussed. It is found that an obtained flow split of 58/42 increased the thruster performance from 3893 N-s/Kg to 4030 N-s/Kg for the same chamber pressure and overall mixture ratio. An increase in performance is also observed when the core mixture ratio is lowered. The thruster was tested for 1.9 hrs with no well degradation.
A mathematical model and a solution algorithm is developed to study the physics of high temperature heat transfer and material ablation and identify the problems associated with the flow of hydrogen gas at very high temperatures and velocities through pipes and various components of Nuclear Thermal Rocket (NTR) motors. Ablation and melting can be experienced when the inner solid surface of the cooling channels and the diverging-converging nozzle of a Nuclear Thermal Rocket (NTR) motor is exposed to hydrogen gas flow at temperatures around 2500 degrees Kelvin and pressures around 3.4 MPa. In the experiments conducted on typical NTR motors developed in 1960s, degradation of the cooling channel material (cracking in the nuclear fuel element cladding) and in some instances melting of the core was observed. This paper presents the results of a preliminary study based on two types of physics based mathematical models that were developed to simulate the thermal-hydrodynamic conditions that lead to ablation of the solid surface of a stainless steel pipe exposed to high temperature hydrogen gas near sonic velocities. One of the proposed models is one-dimensional and assumes the gas flow to be unsteady, compressible and viscous. An in-house computer code was developed to solve the conservations equations of this model using a second-order accurate finite-difference technique. The second model assumes the flow to be three-dimensional, unsteady, compressible and viscous. A commercial CFD code (Fluent) was used to solve the later model equations. Both models assume the thermodynamic and transport properties of the hydrogen gas to be temperature dependent. In the solution algorithm developed for this study, the unsteady temperature of the pipe is determined from the heat equation for the solid. The solid-gas interface temperature is determined from an energy balance at the interface which includes heat transfer from or to the interface by conduction, convection, radiation, and ablation. Two different ablation models are proposed to determine the heat loss from the solid surface due to the ablation of the solid material. Both of them are physics based. Various numerical simulations were carried out using both models to predict the temperature distribution in the solid and in the gas flow, and then predict the ablation rates at a typical NTR motor hydrogen gas temperature and pressure. Solid mass loss rate per foot of a pipe was also calculated from these predictions. The results are presented for fully developed turbulent flow conditions in a sample SS pipe with a 6 inch diameter.
Idaho National Laboratory (INL) is performing high-temperature electrolysis research to generate hydrogen using solid oxide electrolysis cells (SOECs). The project goals are to address the technical and degradation issues associated with the SOECs. This paper provides a summary of various ongoing INL and INL sponsored activities aimed at addressing SOEC degradation. These activities include stack testing, post-test examination, degradation modeling, and a list of issues that need to be addressed in future. Major degradation issues relating to solid oxide fuel cells (SOFC) are relatively better understood than those for SOECs. Some of the degradation mechanisms in SOFCs include contact problems between adjacent cell components, microstructural deterioration (coarsening) of the porous electrodes, and blocking of the reaction sites within the electrodes. Contact problems include delamination of an electrode from the electrolyte, growth of a poorly (electronically) conducting oxide layer between the metallic interconnect plates and the electrodes, and lack of contact between the interconnect and the electrode. INL's test results on high temperature electrolysis (HTE) using solid oxide cells do not provide a clear evidence whether different events lead to similar or drastically different electrochemical degradation mechanisms. Post-test examination of the solid oxide electrolysis cells showed that the hydrogen electrode and interconnect get partially oxidized and become non-conductive. This is most likely caused by the hydrogen stream composition and flow rate during cool down. The oxygen electrode side of the stacks seemed to be responsible for the observed degradation due to large areas of electrode delamination. Based on the oxygen electrode appearance, the degradation of these stacks was largely controlled by the oxygen electrode delamination rate. University of Utah (Virkar) has developed a SOEC model based on concepts in local thermodynamic equilibrium in systems otherwise in global thermodynamic non-equilibrium. This model is under continued development. It shows that electronic conduction through the electrolyte, however small, must be taken into account for determining local oxygen chemical potential, within the electrolyte. The chemical potential within the electrolyte may lie out of bounds in relation to values at the electrodes in the electrolyzer mode. Under certain conditions, high pressures can develop in the electrolyte just under the oxygen electrode (anode)/electrolyte interface, leading to electrode delamination. This theory is being further refined and tested by introducing some electronic conduction in the electrolyte.
Idaho National Laboratory (INL) is performing high-temperature electrolysis research to generate hydrogen using solid oxide electrolysis cells (SOECs). The project goals are to address the technical and degradation issues associated with the SOECs. This paper provides a summary of various ongoing INL and INL sponsored activities aimed at addressing SOEC degradation. These activities include stack testing, post-test examination, degradation modeling, and a list of issues that need to be addressed in future. Major degradation issues relating to solid oxide fuel cells (SOFC) are relatively better understood than those for SOECs. Some of the degradation mechanisms in SOFCs include contact problems between adjacent cell components, microstructural deterioration (coarsening) of the porous electrodes, and blocking of the reaction sites within the electrodes. Contact problems include delamination of an electrode from the electrolyte, growth of a poorly (electronically) conducting oxide layer between the metallic interconnect plates and the electrodes, and lack of contact between the interconnect and the electrode. INL’s test results on high temperature electrolysis (HTE) using solid oxide cells do not provide a clear evidence whether different events lead to similar or drastically different electrochemical degradation mechanisms. Post-test examination of the solid oxide electrolysis cells showed that the hydrogen electrode and interconnect get partially oxidized and become non-conductive. This is most likely caused by the hydrogen stream composition and flow rate during cool down. The oxygen electrode side of the stacks seemed to be responsible for the observed degradation due to large areas of electrode delamination. Based on the oxygen electrode appearance, the degradation of these stacks was largely controlled by the oxygen electrode delamination rate. University of Utah (Virkar) has developed a SOEC model based on concepts in local thermodynamic equilibrium in systems otherwise in global thermodynamic non-equilibrium. This model is under continued development. It shows that electronic conduction through the electrolyte, however small, must be taken into account for determining local oxygen chemical potential, within the electrolyte. The chemical potential within the electrolyte may lie out of bounds in relation to values at the electrodes in the electrolyzer mode. Under certain conditions, high pressures can develop in the electrolyte just under the oxygen electrode (anode)/electrolyte interface, leading to electrode delamination. This theory is being further refined and tested by introducing some electronic conduction in the electrolyte.
The extreme surface conditions of Venus, including high temperature/pressure and reactive chemistry, have previously limited the lifetime of surface missions to ~2 hours. However, recent advances in high temperature technologies suggest the possibility of extended duration missions on the Venus surface. This presentation gives a brief overview on a range of high temperature technologies to enable a possible extended duration Venus surface mission. The technology development under the Long-Lived In Situ Solar System Explorer (LLISSE) project and related technologies will be emphasized as well as that in the High Operating Temperature Technologies (HOTTech) program. The LLISSE project aimed towards developing a full lander system operational for 60 days on the Venus surface and included a power source, electronics, communications, sensors, and the structure, each at a different level of maturity. This presentation briefly describes these and other lander system technologies, their relative level of maturity, and planned future development for Venus surface exploration. It also describes the relevant capabilities and development approach to enable such a mission at NASA Glenn Research Center.
The purpose of this paper is twofold: (1) to discuss high temperature superconductors with specific reference to their employment in telecommunications applications; and (2) to discuss a few of the limitations of the normally employed two-fluid model. While the debate on the actual usage of high temperature superconductors in the design of electronic and telecommunications devices - obvious advantages versus practical difficulties - needs to be settled in the near future, it is of great interest to investigate the parameters and the assumptions that will be employed in such designs. This paper deals with the issue of providing the microwave design engineer with performance data for such superconducting waveguides. The values of conductivity and surface resistance, which are the primary determining factors of a waveguide performance, are computed based on the two-fluid model. A comparison between two models - a theoretical one in terms of microscopic parameters (termed Model A) and an experimental fit in terms of macroscopic parameters (termed Model B) - shows the limitations and the resulting ambiguities of the two-fluid model at high frequencies and at temperatures close to the transition temperature. The validity of the two-fluid model is then discussed. Our preliminary results show that the electrical transport description in the normal and superconducting phases as they are formulated in the two-fluid model needs to be modified to incorporate the new and special features of high temperature superconductors. Parameters describing the waveguide performance - conductivity, surface resistance and attenuation constant - will be computed. Potential applications in communications networks and large scale integrated circuits will be discussed. Some of the ongoing work will be reported. In particular, a brief proposal is made to investigate of the effects of electromagnetic interference and the concomitant notion of electromagnetic compatibility (EMI/EMC) of high T(sub c) superconductors.
The characteristics of gaseous diffusion flames have been obtained using high temperature combustion air under microgravity conditions. The time resolved flame images under free fall microgravity conditions were obtained from the video images obtained. The tests results reported here were conducted using propane as the fuel and about 1000 C combustion air. The burner included a 0.686 mm diameter central fuel jet injected into the surrounding high temperature combustion air. The fuel jet exit Reynolds number was 63. Several measurements were taken at different air preheats and fuel jet exit Reynolds number. The resulting hybrid color flame was found to be blue at the base of the flame followed by a yellow color flame. The length and width of flame during the entire free fall conditions has been examined. Also the relative flame length and width for blue and yellow portion of the flame has been examined under microgravity conditions. The results show that the flame length decreases and width increases with high air preheats in microgravity condition. In microgravity conditions the flame length is larger with normal temperature combustion air than high temperature air.
A recent X-ray observation of the cluster 1E 0657-56 (z = 0.296) with ASC,4 implied an unusually high temperature of approx. 17 keV. Such a high temperature would make it the hottest known cluster and severely constrain cosmological models since, in a Universe with critical density (Omega = 1) the probability of observing such a cluster is only approx. 4 x 10(exp -5). Here we test the robustness of this observational result since it has such important implications. We analysed the data using a variety of different data analysis methods and spectral analysis assumptions and find a temperature of approx. 11 - 12 keV in all cases, except for one class of spectral fits. These are fits in which the absorbing column density is fixed at the Galactic value. Using simulated data for a 12 keV cluster, we show that a high temperature of approx. 17 keV is artificially obtained if the true spectrum has a stronger low-energy cut-off than that for Galactic absorption only. The apparent extra absorption may be astrophysical in origin, (either intrinsic or line-of-sight), or it may be a problem with the low-energy CCD efficiency. Although significantly lower than previous measurements, this temperature of kT approx. 11 - 12 keV is still relatively high since only a few clusters have been found to have temperatures higher than 10 keV and the data therefore still present some difficulty for an Omega = 1 Universe. Our results will also be useful to anyone who wants to estimate the systematic errors involved in different methods of background subtraction of ASCA data for sources with similar signal-to-noise to that of the IE 0657-56 data reported here.
A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approximately 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding.
High-temperature heat pumps (HTHPs) are essential for enhancing energy efficiency across various industrial applications, especially in terms of integrating with renewable energy sources and recovering waste heat. This article thoroughly investigates suitable working fluids for HTHPs, highlighting the evolution from traditional refrigerants to contemporary alternatives with low global warming potential (GWP). It proposes comprehensive selection criteria for these working fluids, pre-selects low-GWP working fluids, and outlines a screening methodology. The pre-selected low-GWP working fluids are evaluated for applications in three typical industrial scenarios involving HTHPs. Furthermore, this study demonstrates that regulatory compliance and environmental impacts significantly influence the development of next-generation refrigerants. The choice of working fluids is closely linked to the types of vapor compression cycles, tailored to the specific industrial applications for HTHPs. This study emphasizes areas for future research, including the development of innovative working fluids; integrated strategies that account for performance, safety, and regulatory standards; alignment of HTHP components; exploration of natural working fluids; and broadening the applications of existing working fluids.
Error scaling is a critical step toward the validation of modeling capabilities for high-temperature gas-cooled reactors (HTGRs). Extensive effort is being made to bring HTGRs into the validation basis of numerous thermal-hydraulics codes. Here, this paper demonstrates how systems-level codes can be leveraged to perform error scaling analyses between an experimental facility and a plant-to-be facility. Specifically, we focus on two conduction cooldown experiments from the High Temperature Test Facility (HTTF) and the General Atomics 350 MW th modular high-temperature gas-cooled reactor (MHTGR-350). The error scaling methodology employed in this study is representativity, which in the context of this work was used to quantify how well experiments captured the physics of the plant facility by comparing sensitivity vectors between the two facilities. In addition, two different RELAP5–3D models of the HTTF were included in the comparison to determine if modeling methodologies notably impact the representativity results. The key figures of merit are the maximum block temperature and the coolant outlet temperature. The time-dependent maximum block temperature had a low representativity of below 0.1 for both models across both transients. The coolant outlet temperature had a higher representativity of around 0.6 for both models during the pressurized conduction cooldown, but it was below 0.2 for the depressurized conduction cooldown. Overall, the HTTF experiments were not representative of the transients in the MHTGR-350. However, these results can play a significant role in informing future potential experiments for HTGR systems that iterate on what the HTTF accomplished.
Two crucial properties influencing the performance of high-temperature alloys are coefficient of thermal expansion (CTE) and phase constitution. It is desirable to have alloys with low CTE, which reduces CTE mismatch with the surface oxide and the likelihood of oxide spallation. Reducing the amount of brittle intermetallic phases such as Sigma (σ) enhances alloy ductility and processability. Here, we propose a multi-objective Bayesian Optimization (BO) model to simultaneously minimize CTE (at an operational temperature of 1150 °C) and T σ (temperature when the Sigma phase completely dissolves in the metal matrix), properties which are obtained from high-throughput CALculation of PHAse Diagrams (CALPHAD). The model successfully identifies several alloys with CTE ≤ 2 × 10 –5 /K and T σ ≤ 500 °C by exploring just 7% of the nickel–chromium–cobalt–aluminum–iron (Ni–Cr–Co–Al–Fe) composition space. Such multi-objective alloy design frameworks can be used to inform additive manufacturing experiments and accelerate alloy discovery for high-temperature energy applications.
Oxygen deficient perovskites Sr{sub 0.75}Y{sub 0.25}Co{sub 1-x}Mn{sub x}O{sub 3-y}, x=0.5 and 0.75, were prepared by using the citrate route at 1373-1573 K for 48 h. The cubic Pm-3m perovskite structure for x=0.5 was confirmed by electron diffraction study and refined using neutron powder diffraction (NPD) data. For x=0.75, the superstructure corresponding to a={radical}(2) Multiplication-Sign a{sub per}, b=2 Multiplication-Sign a{sub per}, c={radical}(2) Multiplication-Sign a{sub per} (a{sup 0}b{sup -}b{sup -} tilt system, space group Imma) was revealed by electron diffraction. The solid solution Sr{sub 0.75-x}Ca{sub x}Y{sub 0.25}Co{sub 0.25}Mn{sub 0.75}O{sub 3-y}, 0.1{<=}x{<=}0.6 and compound Ca{sub 0.75}Y{sub 0.25}Mn{sub 0.85}Co{sub 0.15}O{sub 2.92} were prepared in air at 1573 K for 48 h. The crystal structure of Ca{sub 0.75}Y{sub 0.25}Mn{sub 0.85}Co{sub 0.15}O{sub 2.92} was refined using NPD data (S.G. Pnma, a=5.36595(4), b=7.5091(6), c=5.2992(4) A, R{sub p}=0.057, R{sub wp}=0.056, {chi}{sup 2}=4.26). High-temperature thermal expansion properties of the prepared compounds were studied in air using both dilatometry and high-temperature X-ray powder diffraction data (HTXRPD). They expanding non-linearly at 298-1073 K due to the loss of oxygen at high temperatures. Calculated average thermal expansion coefficients (TECs) for Sr{sub 0.75}Y{sub 0.25}Co{sub 1-x}Mn{sub x}O{sub 3-y}, x=0.5, 0.75 and Ca{sub 0.75}Y{sub 0.25}Mn{sub 0.85}Co{sub 0.15}O{sub 2.92(1)} are 15.5, 15.1, and 13.8 ppm K{sup -1}, respectively. Anisotropy of the thermal expansion along different unit cell axes was observed for Sr{sub 0.15}Ca{sub 0.6}Y{sub 0.25}Co{sub 0.25}Mn{sub 0.75}O{sub 3-y} and Ca{sub 0.75}Y{sub 0.25}Mn{sub 0.85}Co{sub 0.15}O{sub 2.92}. Conductivity of Sr{sub 0.75}Y{sub 0.25}Co{sub 1-x}Mn{sub x}O{sub 3-y}, x=0.5 and 0.75 increases with the temperature reaching 110 S/cm for x=0.5 and 44 S/cm for x=0.75 at 1173 K. Samples of Sr{sub 0.75-x}Ca{sub x}Y{sub 0.25}Co{sub 0.25}Mn{sub 0.75}O{sub 3-y}, 0.1{<=}y{<=}0.6 were found to be n-type conductors at room temperature with the similar temperature dependence of the conductivity and demonstrated the increase of the {sigma} value from {approx}1 to {approx}50 S/cm as the temperature increases from 300 to 1173 K. Their conductivity is described in terms of the small polaron charge transport with the activation energy (E{sub p}) increasing from 340 to 430 meV with an increase of the calcium content from x=0 to x=0.6. - Graphical abstract: The substitution of cobalt in the 314-phase Sr{sub 0.75}Y{sub 0.25}CoO{sub 2.62} by manganese leads to the formation of oxygen deficient compounds Sr{sub 0.75}Y{sub 0.25}Co{sub 1-x}Mn{sub x}O{sub 3-y}, x=0.5 and 0.75, with the cubic and orthorhombic perovskite structures. The conductivity of the x=0.5 sample (110 S/cm) at 1173 K is substantially higher in comparison with x=0.75 (44 S/cm). Together with comparable TEC values for x=0.5 (15.5 ppm K{sup -1}) and 0.75 (15.1 ppm K{sup -1}) samples this makes the former one a promising cathode material for IT-SOFC. Partial replacement of Sr by Ca in Sr{sub 0.75}Y{sub 0.25}Co{sub 0.25}Mn{sub 0.75}O{sub 3-y} leads to the formation of the solid solution with the orthorhombic perovskite structure, Sr{sub 0.75-x}Ca{sub x}Y{sub 0.25}Co{sub 0.25}Mn{sub 0.75}O{sub 3-y}, 0.1{<=}y{<=}0.6. Along with Sr{sub 0.75}Y{sub 0.25}Co{sub 0.5}Mn{sub 0.5}O{sub 3-y}, novel perovskite Ca{sub 0.75}Y{sub 0.25}Mn{sub 0.85}Co{sub 0.15}O{sub 3-y} represent promising cathode material for IT-SOFC due to low TEC value (13.8 ppm K{sup -1}) and high conductivity of 135 S/cm at 1173 K. Highlights: Black-Right-Pointing-Pointer Mn-doped 314-phases Sr{sub 0.75}Y{sub 0.25}Co{sub 1-x}Mn{sub x}O{sub 3-y}, x=0.5, 0.75 were synthesized. Black-Right-Pointing-Pointer Sr{sub 0.75-x}Ca{sub x}Y{sub 0.25}Co{sub 0.25}Mn{sub 0.75}O{sub 3-y}, x=0.1--0.6, Ca{sub 0.75}Y{sub 0.25}Mn{sub 0.85}Co{sub 0.15}O{sub 3-y} were made. Black-Right-Pointing-Pointer High-temperature conductivity properties and crystal structure were studied. Black-Right-Pointing-Pointer High-temperature thermal expansion behavior was investigated.
Thermal radiation properties for solids & coatings at high temperatures
Next generation nuclear reactors such as the advanced high temperature reactor (AHTR) are designed to increase energy efficiency in the production of electricity and provide high temperature heat for industrial processes. The efficient transfer of energy for industrial applications depends on the ability to incorporate effective heat exchangers between the nuclear heat transport system and the industrial process heat transport system. This study considers two different types of heat exchangers - helical coiled heat exchanger and printed circuit heat exchanger - as possible options for the AHTR secondary heat exchangers with distributed load analysis and comparison. Comparison is provided for all different cases along with challenges and recommendations. (authors)