Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hardness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Multimodal hard X-ray nanoprobe techniques for operando investigations of photovoltaic devices

Compared with conventional laboratory-scale X-ray techniques, synchrotron based X-rays with higher brilliance and higher coherence allow for the investigation of various material properties with high spatial resolution. The microscopic behaviours of materials can be examined using the Hard X-ray Nanoprobe beamline (I14) at Diamond Light Source, which provides a 50 nm focused beam and has been successfully employed to identify nanoscale optoelectronic features in energy-harvesting materials such as halide perovskites that exhibit local heterogeneity. We have developed X-ray beam-induced current (XBIC) measurement capability at I14 to address the growing demand for operando analysis in energy-harvesting research. Here, we demonstrate that X-ray fluorescence (XRF)/XBIC multimodal measurements are feasible at I14 and apply these newly implemented techniques to study perovskite solar cells with various additive concentrations to understand the effect of the additive on nanoscale optoelectronic performance. This expanded operando characterization capability offers the possibility of monitoring nanometre-scale compositional variations and corresponding optoelectronic features of actual solar cell configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beta Radiation Hardness of GYGAG(Ce) Transparent Ceramic Scintillators

GYGAG(Ce) transparent ceramic garnet scintillators were irradiated with electrons from 0.5 to 2 MeV with fluences from 10 16 e – /cm 2 to 10 19 e – /cm 2 , corresponding to doses from 0.3 to 310 Gigarad. Absorption spectra were measured before and after irradiations. Light yields from alpha, beta, and gamma excitations were measured before and after irradiation and compared to preirradiation values to gain a deeper understanding of how electron irradiations can affect light yield, as well as defects generated in both the surface and bulk. Within experimental error, no degradation in light yield was observed for the electron-irradiated samples, as measured via beta or gamma excitation, with minimal degradation observed via alpha excitation. A small increase in optical absorption near the wavelength of emission was observed following the largest dose irradiation. These results suggest that GYGAG(Ce) is radiation hard to electron irradiation up to 10 19 e – /cm 2 and doses up to 310 Gigarad. Furthermore, this robustness to irradiation indicates that transparent ceramic garnets may prove useful for applications such as scintillation-based nuclear batteries by allowing for higher energy beta emitters, increased power densities, and enabling long service lifetimes.

36 MATERIALS SCIENCE↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond hard x-ray photoelectron spectroscopy: Simultaneous combination with x-ray diffraction

Hard x-ray photoelectron spectroscopy (HAXPES) is a powerful and novel emerging technique for the nondestructive determination of electronic properties and chemical composition of bulk, buried interfaces and surfaces. It benefits from the exceptionally large escape depth of high kinetic energy photoelectrons, increasing the information depth up to several tens of nanometers. Complementing HAXPES with an atomic structure sensitive technique (such as x-ray diffraction) opens a new research field with major applications for materials science. At SpLine, the Spanish CRG beamline at the European Synchrotron Radiation Facility, we have developed a novel experimental set-up that combines HAXPES and x-ray diffraction (x-ray reflectivity, surface x-ray diffraction, grazing incidence x-ray diffraction, and reciprocal space maps). Both techniques can be operated simultaneously on the same sample and using the same excitation source. The set-up includes a robust 2S + 3D diffractometer hosting a ultrahigh vacuum chamber equipped with a unique photoelectron spectrometer (few eV < electron kinetic energy < 15 keV), x-ray tube (Mg/Ti), 15 keV electron gun, and auxiliary standard surface facilities (molecular beam epitaxy evaporator, ion gun, low energy electron diffraction, sample heating/cooling system, leak valves, load-lock sample transfer, etc.). This end-station offers the unique possibility of performing simultaneous HAXPES + x-ray diffraction studies. In the present work, we describe the experimental set-up together with two experimental examples that emphasize its outstanding capabilities: (i) nondestructive characterization of the Si/Ge and HfO{sub 2}/SiO{sub 2} interfaces on Ge-based CMOS devices, and (ii) strain study on La{sub 0.7}Ca{sub 0.3}MnO{sub 3} ultrathin films grown on SrTiO{sub 3}(001) substrate.

36 MATERIALS SCIENCE↗

Molybdenum and silver photoemission survey spectra from hard x-rays

Electron emission from thick polished samples of polycrystalline molybdenum (Mo) and single crystalline $\langle$111$\rangle$ silver (Ag) was measured with hard x-ray photoemission spectroscopy. Six different excitation x-ray energies were used, nominally 8.0, 11.0, 13.0, 15.0, 18.0, and 21.5 keV. Survey spectra were recorded with each excitation to a kinetic energy of at most 15 keV, often capturing the entire emission range. The Mo 1s core peak was measured. Detailed LMM Auger spectra of Mo show marked increases in intensity and altered shape when x-ray energy exceeds the Mo 1s binding energy. The Mo and Ag L-shell photoelectron peaks are measured at four x-ray energies up to 18 keV showing the transition from 2p3/2 to 2s photoionization dominance.

47 OTHER INSTRUMENTATION↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of the whispering gallery effect on a spherical surface in the hard X-ray region

The whispering gallery effect in the hard X-ray region (0.15-0.3 nm) has been theoretically and experimentally investigated using a concave spherical mirror with a 25-cm radius of curvature and a diameter of 6 cm. A spherical mirror finds and captures the rays incident on its surface in the whispering gallery mode; there is no need to perform an exact alignment of the mirror with respect to the incident X-ray beam in order to observe the effect. To analyze the experimental data, we used the ray tracing method. It is shown that the results of the experiment and computer simulation are in good agreement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theoretical analysis of the possibilities of Zernike phase contrast method in hard X rays for nondestructive imaging of micropipes in a silicon carbide single crystal

The possibilities of using Zernike phase contrast in hard X rays for imaging micropipes in a silicon carbide single crystal are analyzed by numerical simulation. Calculations are performed for the experimental conditions characteristic of third-generation synchrotron radiation sources. A scheme is considered where the focusing element is a parabolic refracting lens and the phase-shifting element is mounted at the point of the source image. It is shown that micropipe cross sections by a beam with a longitudinal diameter reaching 10 {mu}m are imaged by the lens without distortions. At the same time, the lens makes it possible to magnify the image several tens of times. The cross sections that are significantly elongated along the beam are imaged with artifacts; however, their structure can also be recovered. It is shown that polychromaticity of radiation does not significantly affect the object imaging.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hard X-ray emission by clusters in an intense femtosecond laser field during collective recombination

We consider the new mechanism of X-ray generation by clusters under irradiation by femtosecond laser pulses, the so-called collective photorecombination. We develop the theory of the photo-recombination of electrons that pass from atomic clusters at the outer ionization to the ground level of a homogeneously charged cluster. Such a cluster is considered to be a quantum potential well. The dipole approximation is inapplicable for this process. We conclude that X-ray photons in collective photorecombination on a charged cluster as a whole have an energy that is much larger than that for photorecombination on separate atomic ions inside the cluster. For a typical cluster of 2.25 x 10{sup 6} electrons, with a radius R = 300 A, and a number density of plasma electrons n{sub e} = 2 x 10{sup 22} cm{sup -3}, we find that at a 5% outer ionization of this cluster, the energy of hard X-ray photons is 7.2 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerated electrons and hard X-ray emission from X-pinches

The generation of accelerated electrons in the X-pinch minidiode is studied experimentally. It is well known that the explosion of an X-pinch consisting of two or more wires is accompanied by the formation of a minidiode, in which electrons are accelerated. The subsequent slowing down of electrons in the products of wire explosion causes the generation of hard X-ray (HXR) emission with photon energies higher than 10 keV. In this work, the spatial and temporal characteristics of X-pinch HXR emission are studied, the specific features of HXR generation are discussed, and the capability of applying this radiation to point-projection X-ray imaging of various plasma and biological objects is considered. The parameters of the electron beam produced in the X-pinch are measured using a Faraday cup and X-ray diagnostics. The experiments were performed with the XP generator (550 kA, 100 ns) at Cornell University (United States) and the BIN generator (270 kA, 150 ns) at the Lebedev Physical Institute (Russia).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Plasma Focus Device with a 2-MA Discharge Current as a Hard X-Ray Source

A device based on a pulsed current generator with capacitive energy storage loaded on a plasma focus (PF) chamber is described. The device provides a discharge current amplitude of up to 2 MA in the PF chamber at a stored energy in the capacitor bank of up to 150 kJ. The PF chamber is designed to study hard X-ray (HXR) emission. It has windows for output of HXR emission in the cathode direction, as well as a special insert for output of HXR emission into the anode cavity. A study of operation of the chamber as a part of the setup with the use of various X-ray targets on the anode has been carried out. At a discharge current of 1.5MA, an HXR pulse with an average duration of 16 ns and energy spectrum from 10 to 200 keV, which provides an absorbed dose in the irradiated samples on the order of 1 Sv, is generated in the PF chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation hardness of SiC subjected to alternating irradiation and annealing

Effect of the cycle 'introduction of defects, annealing, and repeated introduction of defects' on the SiC properties has been studied by means of nuclear spectrometry for an example of degradation of characteristics of a p-n nuclear radiation detector. The defects were introduced by irradiation with 8-MeV protons in two equal fluences of 3 x 10 14 cm{sup -2}. The total fluence of 6 x 10{sup 14} cm{sup -2} corresponded to an introduction of 2.4 x 10 17 cm{sup -3} primary knocked-out atoms. The annealing was made in two stages, each 1 h long, at temperatures of 600 and 700 {sup o}C. The detectors were tested with 5.4-MeV {alpha} particles, with the charge collection efficiency and specific features of the amplitude spectrum determined. The measurements were performed in the temperature range of 20-250 deg. C. It was shown that the effect of the first irradiation and the subsequent annealing does not significantly change the radiation hardness of SiC. The effective concentration of centers introduced in the course of the second irradiation (at the same fluence) is higher by a factor of 1.2. The nonequivalence of the fluences can also be attributed to the effect of the high total proton fluence of 6 x 10{sup 14} cm{sup -2}.

36 MATERIALS SCIENCE↗

Investigation into the Radiation Hardness of Photodiodes Based on Silicon-on-Sapphire Structures

The electrical properties of photodiodes based on silicon-on-sapphire structures are investigated theoretically and experimentally. It is shown that they are no worse than silicon diodes in terms of their basic parameters, while their radiation hardness is higher by an order of magnitude than that of similar diodes based on bulk silicon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistics-Based Correction to Measurements of Hardness of Rough Surfaces by Instrumented Indentation

Abstract—A procedure for correcting hardness data measured on rough surfaces using instrumented indentation is presented. The correction procedure relies on the knowledge of surface topography, which can be obtained by atomic force microscopy or other appropriate instrumental technique. The analyzed surface is characterized by the standard deviation of height distribution and an autocorrelation function. The latter is proposed to be modeled with an exponential function with either a quadratic or linear exponent.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial resolution of a hard x-ray CCD detector

The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20{mu}m pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95{mu}m (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of microperiodic mirrors for hard x-ray phase-contrast imaging

Differential phase-contrast imaging with hard x rays can have important applications in medicine, material sciences, and energy research. Phase-contrast methods based on microperiodic optics, such as shearing interferometry, are particularly attractive because they allow the use of conventional x-ray tubes. To enable shearing interferometry with x rays up to 100 keV, we propose using grazing-incidence microperiodic mirrors. In addition, a simple lithographic method is proposed for the production of the microperiodic x-ray mirrors, based on the difference in grazing-incidence reflectivity between a low-Z substrate and a high-Z film. Using this method, we produced prototype mirrors with 5-100 {mu}m periods and 90 mm active length. Experimental tests with x rays up to 60 keV indicate good microperiodic mirror reflectivity and high-contrast fringe patterns, encouraging further development of the proposed imaging concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One-dimensional hard x-ray field retrieval using a moveable structure

We present a technique that allows measuring the field of an x-ray line focus using far-field intensity measurements only. One-dimensional phase retrieval with transverse translation diversity is used to recover a hard x-ray beam focused by a compound kinoform lens. The reconstruction is found to be in good agreement with independent knife-edge scan measurements taken at separated planes. The approach avoids the need for measuring the beam profile at focus and allows narrower beams to be measured than the traditional knife-edge scan.

77 NANOSCIENCE AND NANOTECHNOLOGY↗