Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A field study setup of four homes having non-ventilated and semi-conditioned sealed attics

During the 2015-2016 fiscal year and with financial support from the Florida Building Commission (FBC) and the Florida Roofing and Sheet Metal Contractors Association (FRSA ), the University of Florida (UF) and the Oak Ridge National Laboratory (ORNL) completed Phase I of a study that setup four residential home demonstrations in Florida climate zones CZ-1A and CZ-2A. UF and ORNL are evaluating the hygrothermal (heat and moisture flow) performance and durability of sealed attic construction where expanded foam insulation is applied directly to the underside of the roof deck. The four homes are instrumented for measuring temperature and relative humidity of the indoor living space, the outdoor air and the attic air. In addition, the temperature, relative humidity and moisture content of the roof sheathing are being monitored and recorded by remotely-accessible data acquisition equipment. Here, air leakage tests on the whole house, on the sealed attic and in the HVAC ducts were conducted on all four homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Paint Color on Rest Period Climate Control Loads in Long-Haul Trucks: Preprint

Cab climate conditioning is one of the primary reasons for operating the main engine in a long-haul truck during driver rest periods. In the United States, sleeper cab trucks use approximately 667 million gallons of fuel annually for rest period idling. The U.S. Department of Energy's National Renewable Energy Laboratory's (NREL) CoolCab Project works closely with industry to design efficient thermal management systems for long-haul trucks that minimize engine idling and fuel use while maintaining occupant comfort. Heat transfer to the vehicle interior from opaque exterior surfaces is one of the major heat pathways that contribute to air conditioning loads during long-haul truck daytime rest period idling. To quantify the impact of paint color and the opportunity for advanced paints, NREL collaborated with Volvo Group North America, PPG Industries, and Dometic Environmental Corporation. Initial screening simulations using CoolCalc, NREL's rapid HVAC load estimation tool, showed promising air-conditioning load reductions due to paint color selection. Tests conducted at NREL's Vehicle Testing and Integration Facility using long-haul truck cab sections, 'test bucks,' showed a 31.1% of maximum possible reduction in rise over ambient temperature and a 20.8% reduction in daily electric air conditioning energy use by switching from black to white paint. Additionally, changing from blue to an advanced color-matched solar reflective blue paint resulted in a 7.3% reduction in daily electric air conditioning energy use for weather conditions tested in Colorado. National-level modeling results using weather data from major U.S. cities indicated that the increase in heating loads due to lighter paint colors is much smaller than the reduction in cooling loads.

30 DIRECT ENERGY CONVERSION↗

Simulating Physiological Response with a Passive Sensor Manikin and an Adaptive Thermal Manikin to Predict Thermal Sensation and Comfort

Reliable assessment of occupant thermal comfort can be difficult to obtain within automotive environments, especially under transient and asymmetric heating and cooling scenarios. Evaluation of HVAC system performance in terms of comfort commonly requires human subject testing, which may involve multiple repetitions, as well as multiple test subjects. Instrumentation (typically comprised of an array of temperature sensors) is usually only sparsely applied across the human body, significantly reducing the spatial resolution of available test data. Further, since comfort is highly subjective in nature, a single test protocol can yield a wide variation in results which can only be overcome by increasing the number of test replications and subjects. In light of these difficulties, various types of manikins are finding use in automotive testing scenarios. These manikins can act as human surrogates from which local skin and core temperatures can be obtained, which are necessary for accurately predicting local and whole body thermal sensation and comfort using a physiology-based comfort model (e.g., the Berkeley Comfort Model). This paper evaluates two different types of manikins, i) an adaptive sweating thermal manikin, which is coupled with a human thermoregulation model, running in real-time, to obtain realistic skin temperatures; and, ii) a passive sensor manikin, which is used to measure boundary conditions as they would act on a human, from which skin and core temperatures can be predicted using a thermophysiological model. The simulated physiological responses and comfort obtained from both of these manikin-model coupling schemes are compared to those of a human subject within a vehicle cabin compartment transient heat-up scenario.

33 ADVANCED PROPULSION SYSTEMS↗

PHEV Real World Driving Cycle Energy and Fuel and Consumption Reduction Potential for Connected and Automated Vehicles

This paper presents real-world driving energy and fuel consumption results for the second-generation Chevrolet Volt plug-in hybrid electric vehicle (PHEV). A drive cycle, local to Michigan Technological University, was designed to mimic urban and highway driving test cycles in terms of distance, transients and average velocity, but with significant elevation changes to establish an energy intensive real-world driving cycle for assessing potential energy savings for connected and automated vehicle (CAV) control. The investigation began by establishing baseline and repeatability of energy consumption at various battery states of charge. It was determined that drive cycle energy consumption under a randomized set of boundary conditions varied within 3.6% of mean energy consumption regardless of initial battery state of charge. After completing 30 baseline drive cycles, a design for six sigma (DFSS) L18 array was designed to look at sensitivity of a range of parameters to energy consumption as related to connected and automated vehicles to target highest return on engineering development effort. The parameters explored in the DFSS array that showed the most sensitivity, in order of importance, were battery state of charge, vehicle mass, propulsion system thermal conditioning, HVAC setting and driver behavior. Each of these areas are explored for energy savings and discussed briefly in the context of CAV control opportunity for energy savings potential.

33 ADVANCED PROPULSION SYSTEMS↗

OccuTherm: Occupant Thermal Comfort Inference using Body Shape Information

This repository contains the official data from a USDOE-funded project at Carnegie Mellon University and Bosch Research Pittsburgh. The primary goal of the project was to investigate the relationship between indoor commercial building occupant thermal comfort and various biometric and environmental predictors. We performed 77 individual comfort experiments, approved by our Institutional Review Board (IRB) and in satisfaction of participant consent guidelines. Our goal was to generate a dataset than enables comprehensive study of human thermal comfort preferences, in a commercial building environment, across a wide range of indoor environmental conditions. The data is comprised of the following feature groups: depth camera frames, biometrics sensor data, body shape information, subjective comfort data from the mobile device application, environmental sensor data from the commercial building HVAC system, and outdoor weather station data.

47 OTHER INSTRUMENTATION↗

A multi-scale time-series dataset of anthropogenic heat from buildings in Los Angeles County

The dataset contains hourly Anthropogenic heat (AH) from buildings in Los Angeles County, based on weather data from 2018. The hourly AH is aggregated at three spatial resolutions: 450m x 450m grid, 12km x 12km grid, and census tract. The AH is broken down into three components: building envelope surface convection, heating, ventilation, and air conditioning (HVAC) system heat release, and zone exfiltration and exhaust air heat loss. The dataset is created with the physics-based EnergyPlus building energy models to calculate individual buildings' AH considering WRF-UCM simulated microclimate conditions. Please refer to the paper "A multi-scale time-series dataset of anthropogenic heat from buildings in Los Angeles County" for more information about the data generation workflow and the data validation procedure. The data set contains two folders: the "output_data" folder holds the simulation results (EP_output and EP_output_csv), building metadata (building_metadata.geojson and building_metadata.csv), aggregated heat emission and energy consumption time-series data (hourly_heat_energy), and geographical data (geo_data) associated with the GEOID referenced in heat and energy consumption data. The "input_data" folder contains the raw data used to generate files in the "output_data" folder as well as data sets used in the validation. The code repository (https://github.com/IMMM-SFA/xu_etal_2022_sdata) holds the processing scripts for data curation, validation, and visualization.

Energy↗

Transforming Windows from Energy Liabilities to Zero-Energy Assets: Next-Generation Solutions for Buildings

Windows have traditionally contributed to a building's HVAC load, but they can also become a source of net energy gain or even operate as zero-energy components. For heating applications, highly insulating windows can harness more solar heat than the energy lost through them, transforming windows from energy liabilities to assets. Dynamic glazings provide further benefits by regulating solar heat gain, reducing cooling loads in summer and heating demands in winter. This simulation study focuses on developing the next generation of zero-energy windows (ZEW) for residential new construction. Through annual energy simulations across climate zones 1-8, ZEW performance benchmarks were established based on current code-level buildings, and we've identified the regions where meeting ZEW standards are most achievable. This work evaluates both static and dynamic window technologies, assessing their effects on annual energy use and cost. Key findings demonstrate that ZEW performance is achievable across diverse climate zones, with specific regional requirements. Most climate zones from 3-8 can achieve ZEW with specific configurations, while some warm climates (1-2) appear challenging for ZEW implementation. Climate zones 4-6 consistently allow for zero energy window implementation, offering multiple pathways through either static or dynamic window technologies. Colder climate zones (7-8) ZEW products allow for higher SHGC values while requiring low U-values.

Yu, Lili↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Investigating Building Energy Consumption and CO2 Emission in Phoenix Using AutoBEM and Future Typical Meteorological Year (fTMY) Weather Data

This research investigates the energy performance and CO2 emissions of each building stock across the Phoenix metropolitan area using the Automatic Building Energy Modeling (AutoBEM) framework and Model America v2 (MAv2) dataset from Oak Ridge National Laboratory (ORNL). Typical Meteorological Year (TMY) and Future Typical Meteorological Year (fTMY) files were used for AutoBEM simulation. The simulation results from TMY and fTMY were compared. It was found that a projected 10.28% increase in total CO2 emissions and a 9.30% rise in total energy consumption by 2080–2099 relative to current typical conditions. The results highlight the disparities in emissions among different building stocks and the influence of climate change on future energy demand. The findings underscore the necessity of targeted policy interventions and retrofitting strategies (eg. advanced HVAC systems, improved insulation, reflective roofing) to mitigate emissions in high-energy-use and emission-intensed buildings, particularly as climate conditions evolve. This study contributes to the growing understanding of building-sector emissions and their long-term implications under future climate scenarios.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗

Impact of uncoordinated plug-in electric vehicle charging on residential power demand - supplementary data

This data set is provided in support of a forthcoming paper: "Impact of uncoordinated plug-in electric vehicle charging on residential power demand," [1]. These files include electricity demand profiles for 200 households randomly selected among the ones available in the 2009 RECS data set for the Midwest region of the United States. The profiles have been generated using the modeling proposed by Muratori et al. [2], [3], that produces realistic patterns of residential power consumption, validated using metered data, with a resolution of 10 minutes. Households vary in size and number of occupants and the profiles represent total electricity use, in watts. The files also include in-home plug-in electric vehicle recharging profiles for 348 vehicles associated with the 200 households assuming both Level 1 (1920 W) and Level 2 (6600 W) residential charging infrastructure. The vehicle recharging profiles have been generated using the modeling proposed by Muratori et al. [4], that produces real-world recharging demand profiles, with a resolution of 10 minutes. [1] M. Muratori, "Impact of uncoordinated plug-in electric vehicle charging on residential power demand." Forthcoming. [2] M. Muratori, M. C. Roberts, R. Sioshansi, V. Marano, and G. Rizzoni, "A highly resolved modeling technique to simulate residential power demand," Applied Energy, vol. 107, no. 0, pp. 465 - 473, 2013. [3] M. Muratori, V. Marano, R. Sioshansi, and G. Rizzoni, "Energy consumption of residential HVAC systems: a simple physically-based model," in 2012 IEEE Power and Energy Society General Meeting. San Diego, CA, USA: IEEE, 22-26 July 2012. [4] M. Muratori, M. J. Moran, E. Serra, and G. Rizzoni, "Highly-resolved modeling of personal transportation energy consumption in the United States," Energy, vol. 58, no. 0, pp. 168-177, 2013.

2009 RECS↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

Energy conservation and analysis and evaluation

The survey assembled and made recommendations directed at conserving utilities and reducing the use of energy at the Slidell Computer Complex. Specific items included were: (1) scheduling and controlling the use of gas and electricity, (2) building modifications to reduce energy, (3) replacement of old, inefficient equipment, (4) modifications to control systems, (5) evaluations of economizer cycles in HVAC systems, and (6) corrective settings for thermostats, ductstats, and other temperature and pressure control devices.

Source record↗

Site selection feasibility for a solar energy system on the Fairbanks Federal Building

A feasibility study was performed for the installation of a solar energy system on the Federal Building in Fairbanks, Alaska, a multifloor office building with an enclosed parking garge. The study consisted of determining the collectable solar energy at the Fairbanks site on a monthly basis and comparing this to the monthly building heating load. Potential conventional fuel savings were calculated on a monthly basis and the overall economics of the solar system applications were considered. Possible solar system design considerations, collector and other system installation details, interface of the solar system with the conventional HVAC systems, and possible control modes were all addressed. Conclusions, recommendations and study details are presented.

Source record↗